Tender For Provision Of Otm Accommodation For Eme Bn At Mamun Military Station.; 1 Schedule A Part-IConstruction of Specialized Accn, R & I Office, Equipment repair shop and NSC complete all as specified and as shown on drawings. 2 Construction of Garage for ‘B’ Veh (Maruti Gypsy & 2.5 Ton) complete all as specified and as shown on drawings. 3 Construction of Garage for ‘B’ Veh (ALS GLS & ALS Water Browser 5KL) complete all as specified and as shown on drawings. 4 Construction of Garage for ‘B’ Veh (LRV & Spl Lorry) complete all as specified and as shown on drawings. 5 Construction of Garage for ‘B’ Veh (Army Bus & HRV) complete all as specified and as shown on drawings. 6 Construction of Garage for ‘C’ Veh (2 Ton RTFLT, TLR 1 Ton & TLR 500 G2) complete all as specified and as shown on drawings. 7 Construction of Garage for ‘C’ Veh (TLR 1 Ton 2 WHLD 5.56 KVA Gen Set) & Repair Bay complete all as specified and as shown on drawings. 8 Constructions of Storgae Accn (MT), Technical Office & MT DVRS Standby & Change Room complete all as specified and as shown on drawings. 9 Construction of Guard House & Storage Accn complete all as specified and as shown on drawings. 10 Construction of Storage Accn & Tradesman Shop complete all as specified and as shown on drawings. 11 Construction of single living Accn for Hav/ ORs, scooter parking shed, cook house & dining hall complete all as specified and as shown on drawings. 12 Construction of ORs scooter parking shed complete all as specified and as shown on drawings. 13 Construction of ORs institute complete all as specified and as shown on drawings. 14 Construction of Single living Accn JCOs, Parking Shed & JCOs Mess complete all as specified and as shown on drawings. 15 Construction of Religious Institute Hall complete all as specified and as shown on drawings. 16 Construction of Administrative Bldg (D/S) for BN HQ & Parking complete all as specified and as shown on drawings. 17 Construction of Administrative Bldg (D/S) for Div Tps Wksp &Space for Adm Office DIV TPS Wksp Parking Wksp Parking complete all as specified and as shown on drawings. 18 Construction of Single Living Officers, Officers Mess & Servent Otr complete all as specified and as shown on drawings. 19 Construction of Officers Servant Otr & Open Garage complete all as specified and as shown on drawings. 20 Construction of Drying and Ironing Room and Gate Office complete all as specified and as shown on drawings. 21 Construction of Night Picquet for 2 Hav & 06 OR complete all as specified and as shown on drawings. 22 Construction of Ramps complete all as specified and as shown on drawings. 23 Construction of Washing Platform complete all as specified and as shown in drgs. 24 Construction of Sentry Boxes completes all as specified and as shown on drawings. 25 Construction of Elevated Sentry Post completes all as specified and as shown on drawings. 26 Construction of Dhobi Ghat complete all as specified and as shown on drawings. 27 Construction of Incinerator complete all as specified and as shown on drawings. 28 Construction of Refuse Bin complete all as specified and as shown on drawings. 29 Construction of Flag Staff with base complete all as specified and as shown on drawings. 30 Construction of Static Water Tank (50KL) complete all as specified and as shown on drawings. 31 Construction of Football Ground complete all as specified and as shown on drawings. 32 Construction of Basketball Courts complete all as specified and as shown on drawings. 33 Construction of Volleyball Courts complete all as specified and as shown on drawings. 34 Construction of Ramp in R & I area complete all as specified and as shown on drawings. 35 Construction of Washing Platform in R & I area complete all as specified and as shown on drawings. 36 Construction of Fire precauation points complete all as specified and as shown on drawings. 37 Construction of Prade ground (73m x 73m) complete all as specified and as shown on drawings. 38 Construction of Alarm Post complete all as specified and as shown on drawings. 39 Lumpsum price worked out by the contractor for Earth work, Site Clearance and Site development works as listed in Schedule A Part-II. 40 Lumpsum price worked out by the contractor for Plumbing works as listed in Schedule A Part-III. 41 Lumpsum price worked out by the contractor for Internal Water Supply works as listed in Schedule A Part-IV. 42 Lumpsum price worked out by the contractor for Internal Electrification works as listed in Schedule A Part-V. 43 Lumpsum price worked out by the contractor for Protective works as listed in Schedule A Part-VI. 44 Lumpsum price worked out by the contractor for Road, Path and culvert worksas listed in Schedule A Part-VII. 45 Lumpsum price worked out by the contractor for Sewage Disposal worksas listed in Schedule A Part-VIII. 46 Lumpsum price worked out by the contractor for Area Drainage worksas listed in Schedule A Part-IX. 47 Lumpsum price worked out by the contractor for PCC Hardstanding worksas listed in Schedule A Part-X. 48 Lumpsum price worked out by the contractor for Security Fencing worksas listed in Schedule A Part-XI. 49 Lumpsum price worked out by the contractor for Rainwater Harvesting worksas listed in Schedule A Part-XII. 50 Lumpsum price worked out by the contractor for External water supply worksas listed in Schedule A Part-XIII. 51 Lumpsum price worked out by the contractor for External Electrification worksas listed in Schedule A Part-XIV. 52 Lumpsum price worked out by the contractor for Hot water supply worksas listed in Schedule A Part-XV. 53 EARTHWORK, SITE CLEARANCE & SITE DEVELOPMENT WORKSEarthwork in rough excavation in any type of soil by mechanical means (hydraulic excavator) not exceeding 1.5m deep and getting out and disposal of excavated earth lead upto 50m and lift upto 1.5m complete all as specified and directed by Engineer-in-Charge. 54 PLUMBING WORKSSalt-glazed stoneware gully traps, square or round mouthed, type P of size 150mm x 150mm including excavation and earth work, set in PCC M-10 (Nominal mix) block measuring 45cm x 45cm and cast iron grating including in cement mortar (1:1) complete all as specified and as directed by Engineer-in-Charge. 55 INTERNAL ELECTRIFICATION WORKSDistribution Box x MCB Protected Socket With sheet steel Enclosure single pole 25 Amp with 3 pin plug topfor AC connection from Socket point to stabilizer complete all as specified and directed by Engineer-in-Charge. 56 Flame proof (Ex-ds), Gas group IIA,IIB,IIC, Ceiling fan 48 (inch)sweep complete with blades,down rods, regulator, LM6, as per IS / IEC 60079-1:2014, Zone I and Zone II, Die cast aluminium ally material, Class F insulation, Copper winding, 230Volt, Single Phase, AC power consumption complete all as specified and directed by Engineer-in-Charge. 57 Wall mounted Turbo force 450mm air circulator fan, copper wind, 230 volt, 150 CMM air delivery,1400 RPM, 450 mm Sweep size blades and accessories, complete all as specified and directed by Engineer-in-Charge. 58 High performance IP66 LED Streetlight 25 watt, housing made of die-cast aluminium, with street optic lens,with all accessories and connecting up with and including provision of 3 core flexible copper wire of size 1.5sqmm from ceiling rose, to 25 W LED light etc. and including 32mm bore GI light grade protecion pipe upto 1.0m length with suitable fixing accessories on walls, complete all as specified and directed by Engineer-in-Charge. 59 240V, 10 KA B curve miniature circuit breaker (MCB) of single poles and current carrying capacity 63 AMP, in the MCB DB including connection, testing and commissioning complete all as specified and directed by Engineer-in-Charge. 60 Flame proof Distribution board 8 way cast aluminium alloy LM6, IP 65 66, Neoprene gasket,single phase, EX protectionExd type, Classification zone 1 zone 2, operation voltage 230 V, with 8 way breakers and rotary swich complete all as specified and as directed by Engr-in-Charge. 61 LED flood light 100 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp with suitable 15 mm bore GI medium grade pipe for hanging above 1 metre from the crane Channel/ Rally top with suitable fixing accessories of flood light, complete all as specified and directed by Engineer-in-Charge. 62 VTPN DBs Double Door 4 way suitable for MCCB incomer, IP 43 protection 415 V AC, 50 Hz AC appropriate size of copper bus bar and neutral link complete all as specified and directed by Engineer-in-Charge. 63 Earthing complete with Gl earth plate electrode 60cm x 60cm x 6mm thick burrieddirectlyinground(earth pit notless than 2.25 m deep below GL) with top edge of the plate not less than 1.5mbelow the normal ground level connectedgalvanized iron earth lead wire 4.0mm bymeans of bolts, nuts, check nuts and washers of galvanised iron or steelincluding necessary excavation & earth work in any type of soil, removing surplus soil to a distance not exceeding 50 metres,including PCC chamber in PCC (1 : 2 : 4), type B-1, (using 20mm graded crushed stone aggregates), mild steel frame madeout of angle iron of size 40mm x 40mm x 6mm thick duly painted with two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer, hinged with and including 6mm thick Cl coverwith handle, watering arrangement with funnel internally secured with wire mesh with 20 mm dia lightgrade GI pipe for watering, 15 mm dia medium grade, Gl pipe for earth wire protection with and including alternate layer of charcoal dust and common salt complete all as shown in electrical plate No 3connectedto DBs all as specified and indicatedincluding testing on completion complete all as specified and directed by Engineer-in-Charge.Note:- (i) Gl wire upto 7.5m will be measured andpaid under this item only. Extra lead will be measured and paid seperately under relative link. 64 ROAD, PATH & CULVERT WORKSPrecast Cement Concrete, M-15, type B-1, using 20mm graded crushed stone aggregates in kerb stone, rounded and chamfered on edge, set in CM 1:4 complete all as specified and directed by Engineer-in-Charge. 65 Preparation of new or previously treated surfaces and painting lines, dashes, arrows, letters etc on road pavement (Bituminous surfaces) and the like using thermoplastic paint with 2.5mm thick road marking strips (retor-reflective) of specified shade/ colour using hot thermoplastric material @ 8% of glass beads using special applicator machine with heating arrangement upto 160 degree celcius with road marking paint of white or golden yellow by fully/ semi automatic thermoplastic paint applicator machine fitted with profile show heater, driven by experienced operator on road surafce including cost of material, labour, T&P, cleaning the road surface of all dirt, seals, oil, grease and foreign material etc and accordance with applicable specification complete as per direction of Engineer-in-Charge and accordance complete all as specified and directed. 66 Solar road studs of dia 84mm and height 90mm approved byEngineer-in-Charge complete all as specified and directed by Engineer-in-Charge. 67 Solar cat eye having 3 LED /side of colour red/yellow to a side (6 nos) house in tough pressure dia casted aluminium allow of size 125 x 125 x 25 mm with built in steam of suitable length for fixing with approxy LED solar cell battery and light sensor well protected in side under tough under cable for 2 to 3 days (night) after full charge in 8-10 hours of make as approved by Engineer-in-Charge. 68 Stainless steel round road delineator having reflector type red/ yellow colour in plastic body protected in side polycarbonated sheet, protected with powder coated wiremesh cage system mouted complete all as specified and directed by Engineer-in-Charge. 69 Reflective type cat eye having colour red/ yellow to a side, casted aluminium alloy of size 90X110X17mm with built in steam of suitable length for fixing with protected in side complete all as specified and directed by Engineer-in-Charge. 70 Information board with ACP sheet retroreflective writing one side size 600mm x 900mm. Made arround of reflective intensive tape duly fixed on angle iron frame 40x40x4 mm frame with aluminium sheet both side 2mm thick as required with PCC 1:4:8 for post and PCC 1:2:4 for platforms of size 5x3 complete all as specified and directed by Engineer-in-Charge. 71 Yellow or black readymade rubber rumbles speed breaker/ bump with two high reflected reflector in PMMA material are welded/ fitted with ABS plate through ultrasonic welding process size of spreed bump lengh 500m width 250mm hight 50mm fixed with epoxy adhesive sealing compound and suitable nut and bolt as per manufactures instructions complete all as specified and directed by Engineer-in-Charge. 72 80mm thick factory made chamfered edge machine pressed precast concrete interlocking paver block of M-40 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand; complete all as specified and directed by Engineer-in-Charge. 73 SEWAGE DISPOSALRCC NP3 150 mm diameter pipes laid on 150 mm thick PCC cradle 1:4:8 bed with excavation in any type of soil, including manholes/ drop manhole of standard size made of Brick masonry/ RCC/ Precast RCC with SFRC ventilating cover and frame includes all items and activities to execute and make sewer line funtional for depth 0.7m-1.65m complete all as specified and directed by Engineer-in-Charge. 74 RCC NP3 150 mm diameter pipes laid on 150 mm thick PCC cradle 1:4:8 bed with excavation in any type of soil, including manholes/ drop manhole of standard size made of Brick masonry/ RCC/ Precast RCC with SFRC ventilating cover and frame includes all items and activities to execute and make sewer line funtional for depth 1.65m-2.3m complete all as specified and directed by Engineer-in-Charge. 75 RCC Septic tank for 50 users designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design in Walls, Base Slab, Baffle walls and Roof Slab including beams etc with Vent shaft, manhole openings with cover connection etc. complete with effective depth of 1.50 meter and overall depth of 3 meter with UPLOW FILTER complete all as specified and directed by Engineer-in-Charge. 76 RCC Septic tank for 100 users designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design in Walls, Base Slab, Baffle walls and Roof Slab including beams etc with Vent shaft, manhole openings with cover connection etc. complete with effective depth of 1.50 meter and overall depth of 3 meter with UPLOW FILTER complete all as specified and directed by Engineer-in-Charge. 77 RCC Septic tank for 150 users, designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design in Walls, Base Slab, Baffle walls and Roof Slab including beams etc with Vent shaft, manhole openings with cover connection etc. complete with effective depth of 1.50 meter and overall depth of 3 meter with UPLOW FILTER complete all as specified and directed by Engineer-in-Charge. 78 Soakage wells of size 2.4m dia x 4.5m depth, including excavation, in any type of soil, foundation in PCC 1:3:6 walls of honey combed masonry with top ring of M-25 concrete including intercepting chamber and screen chamber made of Brick masonry in CM, RCC cover slab in M-25/SFRC cover, interconnecting pipes of RCC/ DWC complete filled with brick bats effective depth complete all as specified and directed by Engineer-in-Charge. 79 Soakage wells of size 3m dia x 4.5m depth, including excavation, in any type of soil, foundation in PCC 1:3:6 walls of honey combed masonry with top ring of M-25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M-25/SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats effective depth complete all as specified and directed by Engineer-in-Charge. 80 AREA DRAINAGEPrecast Reinforced Cement Concrete (M-25) Design mix, type B-1 (using 20mm graded crushed stone aggregates) as in cover slab for man holes etc set in CM 1:4 complete all as specified and directed by Engineer-in-Charge. 81 PCC HARDSTANDING Plain Cement concrete, M-15 (Nominal Mix), type B-1 (using 20mm graded crushed stone aggregates) 100mm thick as in flooring in alternate bays complete all as specified and as directed. 82 SECURITY FENCING75mm dia CI wheel with ball bearing complete all as specified and as directed by Engineer-in-Charge. 83 RAIN WATER HARVESTINGLoose filling with crushed stone aggregates of gauge 80 to 150mm in soakage pits, soakage wells complete all as specified and directed by Engineer-in-Charge. 84 Loose filling with crushed stone aggregates of gauge 40 to 80mm in soakage pits, soakage wells complete all as specified and directed by Engineer-in-Charge. 85 Laying/ spreading crushed stone aggregate of size 12.5mmcomplete all as specified and directed by Engineer-in-Charge. 86 Laying/ spreading of pea gravel of size 6 to 10mm complete all as specified and directed by Engineer-in-Charge. 87 Laying course sand filling under floors or in foundations including watering and consolidation complete all as specified and directed by Engineer-in-Charge. 88 Trial bore of 300mm dia upto 200mtr depth below ground level in any kind of soil strata including hard stone/ boulder complete all as specified and as directed by Engineer-in-Charge. 89 EXTERNAL WATER SUPPLYCutting existing cast iron 150mm pipes and reducing to required length, before laying in position, for insertion of new tees, branches, etc for repair works, complete all as specified and directed by the Engineer-in-Charge. 90 Excavation in trenches by cutting of road crossing/ PCC hardstanding, under boundary wall for laying of pipe including making good the existing surface with same finish to match the original finish complete all as specified and directed by the Engineer-in-Charge. 91 Supply and laying in trenches or on pillars DI pipe 150mm bore dia centrifuglly cast class K7 including Tyton joints in nay length laid in trenches complete all as specified and directed by the Engineer-in-Charge. (Excavation/ earthwork if required, joints fittings shall be measured and paid for separately). 92 Cast iron Air Valves with two air outlets, 150mm dia bore and fixing Up in DI water supply mains including jointing material such as rubber gaskets, bolts, nuts & washers ofsuitable size complete all as specified and directed by Engineer-in-Charge. 93 Construction of brick masonry valve pit of size 600x600x600mm (internal dimensions) built in cement mortar 1:6, Plain cement concrete, M-10 (nominal Mix) type C-2 (using 40mm graded crushed stone aggregates) as in foundation filling and including 15mm thick plastering internally with cement mortar 1:5 and flush pointing externally as the work proceeds in same mortar and plain cement concrete, M-15 (nominal mix), type B-1, (using 20 mm graded crushed stone aggregates) as in coping 50mm complete including 3.15 mm thick MS sheet cover, handle, locking arrangement including provision of angle iron frame 40mmx40mmx6 mm with 15cm same angle four sidesfor grouting in PCC for cover and earth work in any type of soil including removal to a distance not exceeding 50 mtr and painting steel surface with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engineer-in-Charge. 94 All as per Srl item no 93 here in before but of size 1200x1200x1200mm complete all as specified and directed by Engineer-in-Charge. 95 EXTERNAL ELECTRIFICATION WORKSHigh power LED street light 45 Watt IP 65 Energy saving & environmental friendly long life versatile pressure die-cast aluminium IP65 roadway luminaire with high power LEDs as light source and electronic driver including making electric connection with 1.5 Sqmm multistranded twin core alum cable PVC insulatedcomplete all as specified and directed by Engineer-in-Charge. 96 All as per item No. 95 but LED street light 60 Watt complete all as specified and directed by Engineer-in-Charge. 97 Supply, installing, commissioning and testing of LT feeder pillar box suitable for outdoor installation, factory made, CPRI approved of suitable size for outdoor installation, floor mounted, having sleeve insulated aluminium busbar of rating 250 Amps 3 phase 4 wire mounted on epoxy based insulators, LED indicator lamp set type RYB, internal wiring with PVC insulated but sheathed stranded copper conductor FRLS wire 1100 volts grade of adequate but not less than 4.0 Sqmm size, dust and vermin proof, powder coated in 7 tank process, with IP - 65 class protection, both side openable door, compartamentalised, approns for cable entry & exit with suitable size of glands, terminals & thimbles all as specified, with double door shutter and locking arrangement, made out of 3.15 mm thick CRCA sheet and mounted on angle iron frame 40x40x 6 mm with 70 cm leg, PCC foundation of suitable size all as specified and directed by Engineer-in-Charge with comprising following components:-Location: Offrs Mess 98 (i) MCCB 160 Amps, 415 volts, 50 Hz, 4 pole,36 KA, Thermal Magnetic : O/L & S/C protection, In built or add on module for Earth Leakage Protection -01 No (Incomer)(ii) MCCB 160 Amps, 415 volts, 50 Hz, 4 pole,16 KA, Thermal Magnetic : O/L & S/C protection, In built or add on module for Earth Leakage Protection -01 No(iii) MCB TPN 20 Amps, C curve,415 volts, 50 Hz - 01 No(iv) MCB SPN 32 Amps, C curve,415 volts, 50 Hz - 02 Nos(v) Digital Ammeter 3 phase -01 No(vi) Digital Volt meter 3 phase, 415 volts AC -01 No(vii) Integrated Auxiliary Contactor, 415volts, Max current-40 Amps, 3 pole, 2NO+2NC. 01 No(viii) Astronomical timer, 32 Amps, 415 volts -01 No(ix) LED pilot lamps- 01 set (RYB) 99 Supply, installing, commissioning and testing of LT feeder pillar box suitable for outdoor installation, factory made, CPRI approved of suitable size for outdoor installation, floor mounted, having sleeve insulated aluminium busbar of rating 200 Amps 3 phase 4 wire mounted on epoxy based insulators, LED indicator lamp set type RYB, internal wiring with PVC insulated but sheathed stranded copper conductor FRLS wire 1100 volts grade of adequate but not less than 4.0 Sqmm size, dust and vermin proof, powder coated in 7 tank process, with IP - 65 class protection, both side openable door, compartamentalised, approns for cable entry & exit with suitable size of glands, terminals & thimbles all as specified, with double door shutter and locking arrangement, made out of 3.15 mm thick CRCA sheet and mounted on angle iron frame 40x40x 6 mm with 70 cm leg, PCC foundation of suitable size all as specified and directed by Engineer-in-Charge with comprising following components:-Location: Offrs Mess 100 (i) MCCB 125 Amps, 415 volts, 50 Hz, 4 pole,16 KA-01 Incomer(ii) MCCB 100 Amps, 415 volts, 50 Hz, 4 pole,16 KA-01 No(iii) MCCB 40 Amps, 415 volts, 50 Hz, 4 pole,16 KA-02 Nos(iv) MCB TPN 32 Amps, C curve,415 volts, 50 Hz - 03 Nos(v) MCB SPN 32 Amps, C curve,415 volts, 50 Hz - 03 Nos(vi) Digital Ammeter 3 phase -01 No(vii) Digital Volt meter 3 phase,415 volts AC -01 No(viii) LED pilot lamps- 01 set (RYB) 101 Supply, installing, commissioning and testing of LT feeder pillar box suitable for outdoor installation, factory made, CPRI approved of suitable size for outdoor installation, floor mounted, having sleeve insulated aluminium busbar of rating 200 Amps 3 phase 4 wire mounted on epoxy based insulators, LED indicator lamp set type RYB, internal wiring with PVC insulated but sheathed stranded copper conductor FRLS wire 1100 volts grade of adequate but not less than 4.0 Sqmm size, dust and vermin proof, powder coated in 7 tank process, with IP - 65 class protection, both side openable door, compartamentalised, approns for cable entry & exit with suitable size of glands, terminals & thimbles all as specified, with double door shutter and locking arrangement, made out of 3.15 mm thick CRCA sheet and mounted on angle iron frame 40x40x 6 mm with 70 cm leg, PCC foundation of suitable size all as specified and directed by Engineer-in-Charge with comprising following components:-Location: Adm Block 102 (i) MCCB 125 Amps, 415 volts, 50 Hz, 4 pole,16 KA-01 No (Incomer)(ii) MCCB 125 Amps, 415 volts, 50 Hz, 4 pole,16 KA-01 No(iii) MCB SPN 32 Amps, C curve,415 volts, 50 Hz - 04 Nos(iv) Digital Ammeter 3 phase -01 No(v) Digital Volt meter 3 phase ,415 volts AC -01 No(vi) LED pilot lamps- 01 set (RYB) 103 Supply, installing, commissioning and testing of LT feeder pillar box suitable for outdoor installation, factory made, CPRI approved of suitable size for outdoor installation, floor mounted, having sleeve insulated aluminium busbar of rating 200 Amps 3 phase 4 wire mounted on epoxy based insulators, LED indicator lamp set type RYB, internal wiring with PVC insulated but sheathed stranded copper conductor FRLS wire 1100 volts grade of adequate but not less than 4.0 Sqmm size, dust and vermin proof, powder coated in 7 tank process, with IP - 65 class protection, both side openable door, compartamentalised, approns for cable entry & exit with suitable size of glands, terminals & thimbles all as specified, with double door shutter and locking arrangement, made out of 3.15 mm thick CRCA sheet and mounted on angle iron frame 40x40x 6 mm with 70 cm leg, PCC foundation of suitable size all as specified and directed by Engineer-in-Charge with comprising following components:-Location: Adm Block 104 (i) MCCB 125 Amps, 415 volts, 50 Hz, 4 pole,16 KA-01 No (Incomer)(ii) MCCB 125 Amps, 415 volts, 50 Hz, 4 pole,16 KA-01 No(iii) MCB SPN 32 Amps, C curve,415 volts, 50 Hz - 04 Nos(iv) Digital Ammeter 3 phase -01 No(v) Digital Volt meter 3 phase ,415 volts AC -01 No(vi) LED pilot lamps- 01 set (RYB) 105 Supply, installing, commissioning and testing of LT feeder pillar box suitable for outdoor installation, factory made, CPRI approved of suitable size for outdoor installation, floor mounted, having sleeve insulated aluminium busbar of rating 200 Amps 3 phase 4 wire mounted on epoxy based insulators, LED indicator lamp set type RYB, internal wiring with PVC insulated but sheathed stranded copper conductor FRLS wire 1100 volts grade of adequate but not less than 4.0 Sqmm size, dust and vermin proof, powder coated in 7 tank process, with IP - 65 class protection, both side openable door, compartamentalised, approns for cable entry & exit with suitable size of glands, terminals & thimbles all as specified, with double door shutter and locking arrangement, made out of 3.15 mm thick CRCA sheet and mounted on angle iron frame 40x40x 6 mm with 70 cm leg, PCC foundation of suitable size all as specified and directed by Engineer-in-Charge with comprising following components:-Location: Adm block Div Tps 106 (i) MCCB 125 Amps, 415 volts, 50 Hz, 4 pole,16 KA -01 No ((incomer)(ii) MCCB 125 Amps, 415 volts, 50 Hz, 4 pole,16 KA -01 No(iii) MCB TPN 32 Amps, C curve,415 volts, 50 Hz - 01 No(iv) MCB SPN 32 Amps, C curve,415 volts, 50 Hz - 05 Nos(v) Digital Ammeter 3 phase -01 No(vi) Digital Volt meter 3 phase ,415 volts AC -01 No(vii) LED pilot lamps- 01 set (RYB) 107 Supply, installing, commissioning and testing of LT feeder pillar box suitable for outdoor installation, factory made, CPRI approved of suitable size for outdoor installation, floor mounted, having sleeve insulated aluminium busbar of rating 50 Amps 3 phase 4 wire mounted on epoxy based insulators, LED indicator lamp set type RYB, internal wiring with PVC insulated but sheathed stranded copper conductor FRLS wire 1100 volts grade of adequate but not less than 4.0 Sqmm size, dust and vermin proof, powder coated in 7 tank process, with IP - 65 class protection, both side openable door, compartamentalised, approns for cable entry & exit with suitable size of glands, terminals & thimbles all as specified, with double door shutter and locking arrangement, made out of 3.15 mm thick CRCA sheet and mounted on angle iron frame 40x40x 6 mm with 70 cm leg, PCC foundation of suitable size all as specified and directed by Engineer-in-Charge with comprising following components:-Location: R&I area 108 (i) MCB TPN 32 Amps, C curve,415 volts, 50 Hz - 01 No incomer(ii) MCB SPN 32 Amps, C curve,415 volts, 50 Hz - 05 Nos(iii) Digital Ammeter 3 phase -01 No(iv) Digital Volt meter 3 phase ,415 volts AC -01 No(v) LED pilot lamps- 01 set (RYB) 109 Supply, installing, commissioning and testing of LT feeder pillar box suitable for outdoor installation, factory made, CPRI approved of suitable size for outdoor installation, floor mounted, having sleeve insulated aluminium busbar of rating 200 Amps 3 phase 4 wire mounted on epoxy based insulators, LED indicator lamp set type RYB, internal wiring with PVC insulated but sheathed stranded copper conductor FRLS wire 1100 volts grade of adequate but not less than 4.0 Sqmm size, dust and vermin proof, powder coated in 7 tank process, with IP - 65 class protection, both side openable door, compartamentalised, approns for cable entry & exit with suitable size of glands, terminals & thimbles all as specified, with double door shutter and locking arrangement, made out of 3.15 mm thick CRCA sheet and mounted on angle iron frame 40x40x 6 mm with 70 cm leg, PCC foundation of suitable size all as specified and directed by Engineer-in-Charge with comprising following components:-Location: Workshop 110 (i) MCCB 125 Amps, 415 volts, 50 Hz, 4 pole,16 KA -01 (Incomer)(ii) MCCB 63 Amps, 415 volts, 50 Hz, 4 pole,16 KA -03 Nos(iii) MCB TPN 32 Amps, C curve,415 volts, 50 Hz - 02 Nos(iv) MCB SPN 32 Amps, C curve,415 volts, 50 Hz - 02 Nos(v) Digital Ammeter 3 phase -01 No(vi) Digital Volt meter 3 phase ,415 volts AC -01 No(vii) LED pilot lamps- 01 set (RYB) 111 Supply, installing, commissioning and testing of LT feeder pillar box suitable for outdoor installation, factory made, CPRI approved of suitable size for outdoor installation, floor mounted, having sleeve insulated aluminium busbar of rating 50 Amps 3 phase 4 wire mounted on epoxy based insulators, LED indicator lamp set type RYB, internal wiring with PVC insulated but sheathed stranded copper conductor FRLS wire 1100 volts grade of adequate but not less than 4.0 Sqmm size, dust and vermin proof, powder coated in 7 tank process, with IP - 65 class protection, both side openable door, compartamentalised, approns for cable entry & exit with suitable size of glands, terminals & thimbles all as specified, with double door shutter and locking arrangement, made out of 3.15 mm thick CRCA sheet and mounted on angle iron frame 40x40x 6 mm with 70 cm leg, PCC foundation of suitable size all as specified and directed by Engineer-in-Charge with comprising following components:-Location: Repair Bay 112 (i)MCB TPN 32 Amps, C curve,415 volts, 50 Hz - 01 No Incomer(ii) MCB TPN 32 Amps, C curve,415 volts, 50 Hz - 02 Nos(iii) MCB SPN 32 Amps, C curve,415 volts, 50 Hz - 03 Nos(iv) Digital Ammeter 3 phase -01 No(v) Digital Volt meter 3 phase ,415 volts AC -01 No(vi) LED pilot lamps- 01 set (RYB) 113 Supply, installing, commissioning and testing of LT feeder pillar box suitable for outdoor installation, factory made, CPRI approved of suitable size for outdoor installation, floor mounted, having sleeve insulated aluminium busbar of rating 200 Amps 3 phase 4 wire mounted on epoxy based insulators, LED indicator lamp set type RYB, internal wiring with PVC insulated but sheathed stranded copper conductor FRLS wire 1100 volts grade of adequate but not less than 4.0 Sqmm size, dust and vermin proof, powder coated in 7 tank process, with IP-65 class protection, both side openable door, compartamentalised, approns for cable entry & exit with suitable size of glands, terminals & thimbles all as specified, with double door shutter and locking arrangement, made out of 3.15 mm thick CRCA sheet and mounted on angle iron frame 40x40x 6 mm with 70 cm leg, PCC foundation of suitable size all as specified and directed by Engineer-in-Charge with comprising following components:-Location: Work Shop Tech Trg 114 (i) MCCB 125 Amps, 415 volts, 50 Hz, 4 pole,25 KA -01 Incomer(ii) MCCB 100 Amps, 415 volts, 50 Hz, 4 pole,16 KA,-01 No(iii) MCCB 63 Amps, 415 volts, 50 Hz, 4 pole,16 KA,-01 No(v) MCB TPN 32 Amps, C curve,415 volts, 50 Hz - 01 No(vi) MCB SPN 32 Amps, C curve,415 volts, 50 Hz - 04 Nos(vii) Digital Ammeter 3 phase -01 No(viii) Digital Volt meter 3 phase ,415 volts AC -01 No(ix) LED pilot lamps- 01 set (RYB) 115 Supply, installing, commissioning and testing of LT feeder pillar box suitable for outdoor installation, factory made, CPRI approved of suitable size for outdoor installation, floor mounted, having sleeve insulated aluminium busbar of rating 50 Amps 3 phase 4 wire mounted on epoxy based insulators, LED indicator lamp set type RYB, internal wiring with PVC insulated but sheathed stranded copper conductor FRLS wire 1100 volts grade of adequate but not less than 4.0 Sqmm size, dust and vermin proof, powder coated in 7 tank process, with IP - 65 class protection, both side openable door, compartamentalised, approns for cable entry & exit with suitable size of glands, terminals & thimbles all as specified, with double door shutter and locking arrangement, made out of 3.15 mm thick CRCA sheet and mounted on angle iron frame 40x40x 6 mm with 70 cm leg, PCC foundation of suitable size all as specified and directed by Engineer-in-Charge with comprising following components:-Location: MT Area 2 116 (i) MCB SPN 32 Amps, C curve,415 volts, 50 Hz - 06 Nos(ii) Digital Ammeter 3 phase -01 No(iii) Digital Volt meter 3 phase ,415 volts AC -01 No(iv) LED pilot lamps- 01 set (RYB) 117 Supply, installing, commissioning and testing of LT feeder pillar box suitable for outdoor installation, factory made, CPRI approved of suitable size for outdoor installation, floor mounted, having sleeve insulated aluminium busbar of rating 200 Amps 3 phase 4 wire mounted on epoxy based insulators, LED indicator lamp set type RYB, internal wiring with PVC insulated but sheathed stranded copper conductor FRLS wire 1100 volts grade of adequate but not less than 4.0 Sqmm size, dust and vermin proof, powder coated in 7 tank process, with IP - 65 class protection, both side openable door, compartamentalised, approns for cable entry & exit with suitable size of glands, terminals & thimbles all as specified, with double door shutter and locking arrangement, made out of 3.15 mm thick CRCA sheet and mounted on angle iron frame 40x40x 6 mm with 70 cm leg, PCC foundation of suitable size all as specified and directed by Engineer-in-Charge with comprising following components:-Location: Cook House 118 (i) MCCB 125 Amps, 415 volts, 50 Hz, 4 pole,25 KA,-01 No (Incomer)(ii) MCCB 100 Amps, 415 volts, 50 Hz, 4 pole,25 KA,-01 No(iii) MCCB 40 Amps, 415 volts, 50 Hz, 4 pole,25 KA,-02 Nos(iv) MCB TPN 32 Amps, C curve,415 volts, 50 Hz - 01 Nos(v) MCB SPN 32 Amps, 230 volts ,C curve,50 Hz -05 Nos (vi) Digital Ammeter 3 phase -01 No(vii) Digital Volt meter 3 phase ,415 volts AC(viii) LED pilot lamps- 01 set (RYB) 119 Supply, installing, commissioning and testing of LT Panel cubical type suitable for outdoor installation, factory made, CPRI approved of suitable size for outdoor installation, floor mounted, having sleeve insulated aluminium busbar of rating 300 Amps 3 phase 4 wire mounted on epoxy based insulators, LED indicator lamp set type RYB, internal wiring with PVC insulated but sheathed stranded copper conductor FRLS wire 1100 volts grade of adequate but not less than 4.0 Sqmm size, dust and vermin proof, powder coated in 7 tank process, withIP-65 class protection, both side openable door, compartamentalised, approns for cable entry & exit with suitable size of glands, terminals & thimbles all as specified, with double door shutter and locking arrangement, made out of 3.15 mm thick CRCA sheet and mounted on angle iron frame 40x40x 6 mm with 70 cm leg, PCC foundation of suitable size all as specified and directed by Engineer-in-Charge with comprising following components:-Location: JCOs Mess or Living and MT area 120 (i) MCCB 200 Amps, 415 volts, 50 Hz, 4 pole,16 KA, Thermal Magnetic : O/L & S/C protection, In built or add on module for Earth Leakage Protection -01 No (Incomer)(ii) MCCB 125 Amps, 415 volts, 50 Hz, 4 pole,16 KA -01 No(iii) MCCB 100 Amps, 415 volts, 50 Hz, 4 pole,16 KA,-01 No(iv) MCCB 40 Amps, 415 volts, 50 Hz, 4 pole,16 KA,-02 Nos(v) MCB TPN 20 Amps, C curve,415 volts, 50 Hz - 03 Nos (vi) MCB SPN 32 Amps, C curve,415 volts, 50 Hz - 02 Nos(vii) Digital Ammeter 3 phase -01 No(viii) Digital Volt meter 3 phase ,415 volts AC -01 No(ix) Integrated Auxiliary Contactor , 415volts,Max current-40 Amps,3 pole,2NO+2NC. 01 No(x) Astronomical timer, 32 Amps,415 volts -01 No(xi) LED pilot lamps- 01 set (RYB) 121 Supply, installing, commissioning and testing of LT feeder pillar box suitable for outdoor installation, factory made, CPRI approved of suitable size for outdoor installation, floor mounted, having sleeve insulated aluminium busbar of rating 200 Amps 3 phase 4 wire mounted on epoxy based insulators, LED indicator lamp set type RYB, internal wiring with PVC insulated but sheathed stranded copper conductor FRLS wire 1100 volts grade of adequate but not less than 4.0 Sqmm size, dust and vermin proof, powder coated in 7 tank process, with IP - 65 class protection, both side openable door, compartamentalised, approns for cable entry & exit with suitable size of glands, terminals & thimbles all as specified, with double door shutter and locking arrangement, made out of 3.15 mm thick CRCA sheet and mounted on angle iron frame 40x40x 6 mm with 70 cm leg, PCC foundation of suitable size all as specified and directed by Engineer-in-Charge with comprising following components:-Location: JCOs Mess 122 (i) MCCB 125 Amps, 415 volts, 50 Hz, 4 pole,16 KA, -01 No ((incomer)(ii) MCCB 63 Amps, 415 volts, 50 Hz, 4 pole,16 KA, -01 Nos(iii) MCCB 40 Amps, 415 volts, 50 Hz, 4 pole,16 KA, -03 Nos(iv) MCB TPN 32 Amps, C curve,415 volts, 50 Hz - 01 Nos (v) MCB SPN 32 Amps, C curve,415 volts, 50 Hz - 06 Nos(vi) Digital Ammeter 3 phase -01 No(vii) Digital Volt meter 3 phase ,415 volts AC -01 No(viii) LED pilot lamps- 01 set (RYB) 123 Supply, installing, commissioning and testing of LT feeder pillar box suitable for outdoor installation, factory made, CPRI approved of suitable size for outdoor installation, floor mounted, having sleeve insulated aluminium busbar of rating 60 Amps 3 phase 4 wire mounted on epoxy based insulators, LED indicator lamp set type RYB, internal wiring with PVC insulated but sheathed stranded copper conductor FRLS wire 1100 volts grade of adequate but not less than 4.0 Sqmm size, dust and vermin proof, powder coated in 7 tank process, with IP-65 class protection, both side openable door, compartamentalised, approns for cable entry & exit with suitable size of glands, terminals & thimbles all as specified, with double door shutter and locking arrangement, made out of 3.15 mm thick CRCA sheet and mounted on angle iron frame 40x40x 6 mm with 70 cm leg, PCC foundation of suitable size all as specified and directed by Engr-in-Charge with comprising following components:-Location: Sports Ground 124 (i) MCCB 40 Amps, 415 volts, 50 Hz, 4 pole,16 KA,-01 No(ii) MCB TPN 32 Amps, C curve,415 volts, 50 Hz - 01 Nos(iii) MCB SPN 32 Amps, C curve,415 volts, 50 Hz - 05 Nos(iv) Digital Ammeter 3 phase -01 No(v) Digital Volt meter 3 phase ,415 volts AC -01 No(vi) LED pilot lamps- 01 set (RYB) 125 Supply, installing, commissioning and testing of LT feeder pillar box suitable for outdoor installation, factory made, CPRI approved of suitable size for outdoor installation, floor mounted, having sleeve insulated aluminium busbar of rating 60 Amps 3 phase 4 wire mounted on epoxy based insulators, LED indicator lamp set type RYB, internal wiring with PVC insulated but sheathed stranded copper conductor FRLS wire 1100 volts grade of adequate but not less than 4.0 Sqmm size, dust and vermin proof, powder coated in 7 tank process, with IP-65 class protection, both side openable door, compartamentalised, approns for cable entry & exit with suitable size of glands, terminals & thimbles all as specified, with double door shutter and locking arrangement, made out of 3.15 mm thick CRCA sheet and mounted on angle iron frame 40x40x 6 mm with 70 cm leg, PCC foundation of suitable size all as specified and directed by Engineer-in-Charge with comprising following components:-Location: MT Area 126 (ii) MCCB 40 Amps, 415 volts, 50 Hz, 4 pole,16 KA -01 No (incomer)(iii) MCB TPN 32 Amps, C curve,415 volts, 50 Hz - 02 Nos(iv) MCB SPN 32 Amps, C curve,415 volts, 50 Hz - 06 Nos(v) Digital Ammeter 3 phase -01 No(vi) Digital Volt meter 3 phase ,415 volts AC -01 No(vii) LED pilot lamps- 01 set (RYB) 127 Supply, installing, commissioning and testing of LT feeder pillar box suitable for outdoor installation, factory made, CPRI approved of suitable size for outdoor installation, floor mounted, having sleeve insulated aluminium busbar of rating 50 Amps 3 phase 4 wire mounted on epoxy based insulators, LED indicator lamp set type RYB, internal wiring with PVC insulated but sheathed stranded copper conductor FRLS wire 1100 volts grade of adequate but not less than 4.0 Sqmm size, dust and vermin proof, powder coated in 7 tank process, with IP-65 class protection, both side openable door, compartamentalised, approns for cable entry & exit with suitable size of glands, terminals & thimbles all as specified, with double door shutter and locking arrangement, made out of 3.15 mm thick CRCA sheet and mounted on angle iron frame 40x40x 6 mm with 70 cm leg, PCC foundation of suitable size all as specified and directed by Engineer-in-Charge with comprising following components:-Location: Street Lights 128 (i) MCB TPN 32 Amps, C curve,415 volts, 50 Hz - 07 Nos(iii) MCB SPN 32 Amps, C curve,415 volts, 50 Hz - 02 Nos(iv) Digital Ammeter 3 phase -01 No(v) Digital Volt meter 3 phase ,415 volts AC -01 No(vi) Integrated Auxiliary Contactor , 415volts,Max current-40 Amps, 3 pole, 2NO+2NC. 01 No(vii) Astronomical timer, 32 Amps,415 volts -01 No(viii) LED pilot lamps- 01 set (RYB) 129 Supply, installing, commissioning and testing of LT feeder pillar box suitable for outdoor installation, factory made, CPRI approved of suitable size for outdoor installation, floor mounted, having sleeve insulated aluminium busbar of rating 200 Amps 3 phase 4 wire mounted on epoxy based insulators, LED indicator lamp set type RYB, internal wiring with PVC insulated but sheathed stranded copper conductor FRLS wire 1100 volts grade of adequate but not less than 4.0 Sqmm size, dust and vermin proof, powder coated in 7 tank process, with IP-65 class protection, both side openable door, compartamentalised, approns for cable entry & exit with suitable size of glands, terminals & thimbles all as specified, with double door shutter and locking arrangement, made out of 3.15 mm thick CRCA sheet and mounted on angle iron frame 40x40x 6 mm with 70 cm leg, PCC foundation of suitable size all as specified and directed by Engr-in-Charge with comprising following components:-Location: Work Shop 2 (Anciliary Shop) 130 (i) MCCB 125 Amps, 415 volts, 50 Hz, 4 pole,16 KA, -01 No ((incomer)(ii) MCCB 125 Amps, 415 volts, 50 Hz, 4 pole,16 KA, -01 No (iii) MCB TPN 32 Amps, C curve,415 volts, 50 Hz - 07 Nos(iv) MCB SPN 32 Amps, C curve,415 volts, 50 Hz - 02 Nos(v) Digital Ammeter 3 phase -01 No(vi) Digital Volt meter 3 phase ,415 volts AC -01 No(vii) Integrated Auxiliary Contactor , 415volts,Max current-40 Amps,3 pole,2NO+2NC. 01 No(viii) Astronomical timer, 32 Amps,415 volts -01 No(ix) LED pilot lamps- 01 set (RYB) 131 Supply, installing, commissioning and testing of LT Panel cubical type suitable for outdoor installation, factory made, CPRI approved of suitable size for outdoor installation, floor mounted, having sleeve insulated aluminium busbar of rating 1500 Amps 3 phase 4 wire mounted on epoxy based insulators, LED indicator lamp set type RYB, internal wiring with PVC insulated but sheathed stranded copper conductor FRLS wire 1100 volts grade of adequate but not less than 4.0 Sqmm size, dust and vermin proof, powder coated in 7 tank process, with IP-65 class protection, both side openable door, compartamentalised, approns for cable entry & exit with suitable size of glands, terminals & thimbles all as specified, with double door shutter and locking arrangement, made out of 3.15 mm thick CRCA sheet and mounted on angle iron frame 50x50x 6 mm with 70 cm leg, PCC foundation of suitable size all as specified and directed by Engr-in-Charge with comprising following components:-Location: Main LT Panel 132 (i) Air Circuit breaker, 415 volts, draw out type,1000 Amps 415 volts,50 KA,50 Hz, 4 pole(ii) MCCB 200 Amps, 415 volts, 50 Hz, 4 pole,25 KA, Thermal Magnetic : O/L & S/C protection, In built or add on module for Earth Leakage Protection -02 Nos(iii) MCCB 160 Amps, 415 volts, 50 Hz, 4 pole,25 KA, Thermal Magnetic : O/L & S/C protection, In built or add on module for Earth Leakage Protection -01 No(iv) MCCB 125 Amps, 415 volts, 50 Hz, 4 pole,25 KA, -07 Nos(v) MCCB 63 Amps, 415 volts, 50 Hz, 4 pole,25 KA, -01 No(vi) MCCB 40 Amps, 415 volts, 50 Hz, 4 pole,16 KA,-01 No(vii) MCB TPN 32 Amps, C curve,415 volts, 50 Hz - 05 Nos(viii) MCB SPN 32 Amps, 230 volts ,C curve,50 Hz -02 Nos(ix) Digital Ammeter 3 phase -01 No(x) Digital Volt meter 3 phase ,415 volts AC -01 No(xi) Digital Volt meter 3 phase ,415 volts AC -01 No 133 Supply, installing, commissioning and testing of LT feeder pillar box suitable for outdoor installation, factory made, CPRI approved of suitable size for outdoor installation, floor mounted, having sleeve insulated aluminium busbar of rating 160 Amps 3 phase 4 wire mounted on epoxy based insulators, LED indicator lamp set type RYB, internal wiring with PVC insulated but sheathed stranded copper conductor FRLS wire 1100 volts grade of adequate but not less than 4.0 Sqmm size, dust and vermin proof, powder coated in 7 tank process, with IP-65 class protection, both side openable door, compartamentalised, approns for cable entry & exit with suitable size of glands, terminals & thimbles all as specified, with double door shutter and locking arrangement, made out of 3.15 mm thick CRCA sheet and mounted on angle iron frame 40x40x 6 mm with 70 cm leg, PCC foundation of suitable size all as specified and directed by Engineer-in-Charge with comprising following components:-Location: ORs single living 134 (i) MCCB 100 Amps, 415 volts, 50 Hz, 4 pole,16 KA,-01 No(ii) MCB TPN 32 Amps, C curve,415 volts, 50 Hz - 01 Nos(iii) MCB SPN 32 Amps, C curve,415 volts, 50 Hz - 05 Nos(iv) Digital Ammeter 3 phase -01 No(v) Digital Volt meter 3 phase ,415 volts AC -01 No(vi) LED pilot lamps- 01 set (RYB) 135 Cable jointing kit for 1100 volt grade cable for outdoor termination end joint heat shrinkable type complete with jointing material and accessories suitable for XLPE/PVC armoured aluminium conductor cable of size 16 to 35 Sqmm 3.5/4 core complete all as specified and directed by Engineer-in-Charge. 136 All as per item No 116 but for cable of size 25 Sqmm 2 core complete all as specified and directed by Engineer-in-Charge. 137 All as per item No 116 but for cable of size 50 to 95 Sqmm complete all as specified and directed by Engineer-in-Charge. 138 All as per item No 116 but for cable of size 120 to 185 Sqmm complete all as specified and directed by Engineer-in-Charge. 139 All as per item No 116 but for cable of size 225 to 300 Sqmm complete all as specified and directed by Engineer-in-Charge. 140 All as per item No 116 but for cable of size 400 to 500 Sqmm complete all as specified and directed by Engineer-in-Charge. 141 Pole mounted street lightjunction box, Hot press, moulded SMC, side hinged door, outdoor type, mounted on steel pole including aluminium bus bar, 4 wire, 200 Amps, MCB SP, 230 volts,10 Amps-01 No, minimum internal diamension 300 x 200 x 105mm with printed sign of skull and bones for danger notice complete all as specified and directed by Engineer-in-Charge.Note : Cost of Clamps, nuts, botls and washers for fixing junction box on pole shall be measured and paid seperately. 142 Pole mounted street lightjunction box, Hot press, moulded SMC, side hinged door, outdoor type, mounted on steel pole including aluminium bus bar, 4 wire, 200 Amps, MCB SP, 230 volts,10 Amps-02 Nos, minimum internal diamension 300 x 200 x 105mm with printed sign of skull and bones for danger notice complete all as specified and directed by Engineer-in-Charge.Note : Cost of Clamps, nuts, bolts and washers for fixing junction box on pole shall be measured and paid seperately 143 Pole mounted street lightjunction box, Hot press, moulded SMC, side hinged door, outdoor type, mounted on steel pole including aluminium bus bar, 4 wire, 200 Amps, MCB SP, 230 volts,10 Amps-04 Nos, minimum internal diamension 300 x 200 x 105mm with printed sign of skull and bones for danger notice complete all as specified and directed by Engineer-in-Charge.Note : Cost of Clamps, nuts, bolts and washers for fixing junction box on pole shall be measured and seperately 144 Pole mounted street lightjunction box, Hot press, moulded SMC, side hinged door, outdoor type, mounted on steel pole including aluminium bus bar, 2 wire, 200 Amps, MCB SP, 230 volts,10 Amps -01 No, minimum internal diamension 250 x 200 x 100mm with printed sign of skull and bones for danger notice complete all as specified and directed by Engineer-in-Charge.Note: Cost of Clamps, nuts, bolts and washers for fixing junction box on pole shall be measured and seperately 145 Supply, fixing or laying in pole & testing PVC insulated, PVCsheathed cable galvanized steel strip or wire armoured, electric control cables(Heavy duty) with stranded copper conductor of size 1.5 sq mm, 3 core, 1100Volts grade complete all as specified and directed by Engineer-in-Charge.(Note : Quoted rates shall deemed to be included for making hole in pole etc.) 146 Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150mmdia suitable for 0.4 mpa working pressure complete all as specified and directed by Engineer-in-Charge.Note : Item rate include work across National High Way and the Contractor will be responsible for taking necessary permission from NHAI/ State Authorities. 147 Coarse aggregate 40mm size down graded including spreading and levelling surrounding area of 2 pole structures after making boundary wall by using bricks, PCC and plaster complete all as specified and directed by Engineer-in-Charge.(Note : Height of brick wall is 30cm below the ground level and 30cm above the ground level). 148 Supply, fixing, connecting and testing of OEM Manufactured APFC Panel with 7% aluminium reactor of capacity 90 KVAR (Output) @ 440V AC. The stage ratings shall be 1 x 5 KVAr + 2 x 10 KVAR + 2 x 20 KVAR + 1 x 25 KVAR. The APFC Panel shall be fully type tested at an Independent Laboratory. The degree of protection of enclosures system of the APFC panel shall be min. IP41 in accordance. The capacitor bank shall be internet of things (IoT) enabled and communicable/ integrable with BMS. The APFC panel shall be (Indoor) type conforming to IS 13341:1992 & IS 13440:1993 floor mounted design, weather, dust and vermin proof. As equipment shall be comprising of the following:-(i)Insulated bus bar pan assembly made from Aluminium and rated of 250 Amps capacity. The short circuit withstand capacity chall be 50 ka/ 1 sec (lcw) for the main bus bar and the rated impulse withstand voltage shall be 6 KV.(ii)The incomer of the APFC panel shall be 160 Amps, MCCB, 4P, 50 ka, TMD type with O/L & S/C protection, lcs = 100% lcu, MCCB shall have standed rotary handle, spreaders, phase barrier. MCCB shall be certified design of Approved makes. 149 Earthing complete with GIearth plate electrode of size 60cm X 60cm and thickness not less than 6mm buried directly in ground vertically at a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides by 15 cm thick and packed layer of charcoal dust and common salt filling in alternate layers etc and connected to and including GI strip of size 32x6 mm by means of bolts, nuts, check nuts and washers made of brass and protected by light grade 40mm dia GI pipe connected to equipments and GI pipe light grade 20mm bore for watering and including funnel, wire mesh, RCC pit cover 50mm thick and PCC chamber pit with PCC 1:2:4 type C2 (including excavation and earth work disposal of surplus soil to a distance not exceeding 50 metre) and testing after completion all as specified and shown on plate No 3 of SSR Part-I 2009 making test point and all connections complete all as specified & directed by Engineer-in-charge. 150 Earthing complete with GIearth plate electrode of size 60cm X 60cm and thickness not less than 6mm buried directly in ground vertically at a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides by 15 cm thick and packed layer of charcoal dust and common salt filling in alternate layers etc and connected to and including GI wire of size 4.0 mm by means of bolts, nuts, check nuts and washers made of brass and protected by light grade 40mm dia GI pipe connected to equipments and GI pipe light grade 20mm bore for watering and including funnel, wire mesh, RCC pit cover 50mm thick and PCC chamber pit with PCC 1:2:4 type C2 (including excavation and earth work disposal of surplus soil to a distance not exceeding 50 metre) and testing after completion all as specified and shown on plate No 3 of SSR Part-I 2009 making test point and all connections complete all as specified & directed by Engineer-in-charge. 151 Sand cushioning to under ground cables 8cm thick before laying the cable and 15cm, thick after laying, stretching and testing the cable complete all as specified and directed by Engineer-in-Charge.(Note:- Only punned thickness i.e 18cm shall be measured and paid). 152 Sub class ‘B’ bricks old size, laid dry, flat over the cable abutting each other, length of cable equal to width of brick all as required complete all as specified and directed by Engineer-in-Charge. 153 PCC, M-15, type B-1, using 20mm graded crushed stone aggregates as in floor/ hard-standing, surface finished even and smooth without using extra cement to match with the existing surface complete all as specified and directed by Engineer-in-Charge. 154 Supply, installation, commissioning and testing of transformer step down, outdoor type, copper wound, oil cooled, 11/0.433 KV (at no load) with HT 3 phase and LT 3 phase 4 wires, AC, 50 Hz of capacity 500 KVA with off load tap changing arrangement on HT side for a variation of secondary voltage +/- 7.5% in steps of +/- 2.5% including suitable cable entry box on LT side and HT bushing on primary side complete in all respect with standard accessories and fittings confirming to IS 2026 and as directed with first filling of transformer oil upto the recommended level by the manufacturer with new oil complete all as specified and as directed by Engineer-in-Charge including construction of platform of size 3 mtr x 2.5 mtr and height 1.5 mtr with following specifications:-(a) Earth work in soft/ loose soil.(b) 20cm thick PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregates) lean concrete in foundation.(c) Complete brick work of size 3 mtr x 2.5 mtr x 1.5 mtr with sub class ’B’ bricks built in cement mortar 1:4 above ground level and foundation of plate form not less than 0.75 mtr below ground level.(d) 100mm thick PCC 1:2:4 type D-2 (using 20mm graded aggregates) over brick platform. 155 (e) Angle iron fencing post of size 40x40x6m of height 1.8 metre at 2 metre c/c around brick platform including excavation and earth work and 30 cm embedded portion of angle iron in PCC 1:2:4 type B-2 of size 60 cm x 60 cm.(f) 6 rows of 2 strand steel barbed wire 2.24 dia barbs at 75mm spacing.(g) Angle iron gate using 40x40mm angle iron of size 2 mtr x 1.5 mtr with vertical flat 25x6 mm @ 10cm c/c hinges and locking arrangement.(h) 15mm thick plaster in CM 1:6 on brick masonry platform.(j) All exposed surfaces of steel work shall be painted two coats of synthetic enamel paint over a red oxide primer and PCC work with white snowcem of approved colour.(k) 04 Nos of steps to reach the top of the platform. 156 Steeltubular swaged pole 9 metre, type 410, SP-31 long with case iron base plate, finial taper plug, nolts, nuts and washers including painting with two coats of black bituminious paint thriugh out internally and externally upto planning depth and marking/ painting 05 Nos circular strips 30cm each (colour combination as directed) with synthetic enamel paint. Remaining portion of pole above 1.5 mtr painting with two coat of aluminium paint to the entire exposed surfaces over one coat of red oxide primer, and marking pole number etc complete all as specified and directed by Engineer-in-Charge.(Note :- Excavation and earth work and PCC shall be measured and paid separately under repsective items). 157 All as per item No 136 but steel tubular swaged pole 11 mtr long, type 410 SP-55 complete all as specified and directed by Engineer-in-Charge. 158 LED flood light 100 Watt, IP-66 complete including fixing arrangements i.e suitable clamps, nut, bolt and washers and making electric connection with 1.5 Sqmm multistranded twin core aluminium cable PVC insulated complete all as specified and directed by Engineer-in-Charge. 159 Post top lantern, LED 20 watts, 230 watt volts AC, outdoor type, IP-65, B-22 base lamp holder, LED lamp as light source, clear cover with impact and corrosion resistant suitable for pole 50mm bore dia complete with all accessories all as specified and directed by Engineer-in-Charge. 160 LED 40 watts post top gate light, 230 watt volts AC, outdoor type, IP-65, spun aluminium die cast landscape luminaire with high power LEDs as light source, clear cover with impact and corrosion resistant, input voltage 150-270 volts, 50000 burning hours complete with all accessories all as specified and as directed by Engineer-in-Charge. 161 Street light mounting bracket fabricated out of GI pipe, ight grade, 40mm bore dia including reducer for fixing of light fitting, 150cm long, bent to shape for mounting on steel pipecomplete all as specified and as directed by Engineer-in-Charge.Note : Cost of Clamp, nuts, bolts and washers for fixing bracket on pole shall be measured and paid separately. 162 GI tubing, light grade, 80mm bore with fittings, laid for protection of cable under road crossing/ fixed to walls or polecomplete all as specified and directed by Engineer-in-Charge.(Note : clamps for fixing pipe, nuts, bolts washers shall be measured separately) 163 All as per Srl Item No 142 here-in-above 50mm bore complete all as specified and directed by Engineer-in-Charge. 164 All as per Srl Item No 142 here-in-above 40mm bore complete all as specified and directed by Engineer-in-Charge. 165 HOT WATER SUPPLYSupply, Install, Testing and commissioning of Solar cum electric Water heating System (Evacuated tube collector) based on direct transfering of heat, thermosyphon circulation of capacity 300 LPD suitable for bathing purpose consisting of following components all as specified and as per manufacturer design and comprising of the following:- (a) Evacuated tube collector assembly suitable for 300 LPD. (b) Stainless steel hot water tank with a heat resistant protective coating and insulated with polyurethane foam with scarificial anode and electric back up with minimum 2KW element. (c) Collector stand. (d) Tank stand assembly (e) Piping of suitable size from cold water supply tank to hot water tank and to collector including connecting collectors. (f) Hot water pipe from collector assembly to hot water tank making connection to pipe fixtures to the tank all as specified. (g) open vent pipe for pressure build up. (h) Instrument (one temp guage, strainer, water meter etc. (j) Make up tank and antifreeze sloution. (k) Gate valve for cold and hot water piping of suitable size. (l) complete arrangement for mounting the collector panels incl necessary plinth / foundation of suitable size complete all as specified and as directed by Engineer-in-Charge. 166 All as per srl item No 145 here in above but for 200 LPD capacity complete all as specified and as directed by Engineer-in-Charge. 167 All as per srl item No 145 here in above but for 100 LPD capacity complete all as specified and as directed by Engineer-in-Charge. 168 3 layer PP-R pipe of size 20mm SDR 11 UV stablized and antimicrobial welded having thermal stability for hot and cold water supply including all PP-R plain and brass threaded polypropylene random fittings fix complete to walls ceiling or in floors etccomplete all as specified and as directed by Engineer-in-Charge. 169 DESERT COOLERSupply, install, testing and commissioning of Desert Cooler of steel body thickness 20mm gauge nominal capacity of air 4000 Cum/ hours having copper bound motor, submersible water lifting pump and connected with accessories etc complete all as specified and directed by Engineer-in-Charge. 170 Supply, install, testing and commissioning Desert Cooler of steel body thickness 20mm gauge nominal capacity of air 3000 Cum/ hours having copper bound motor, submersible water lifting pump and connected with accessories etc complete all as specified and directed by Engineer-in-Charge. 171 Fabrication desert cooler stand LXB is equal to the base of desert cooler of capacity 4000 Cum/ Hrs with MS equal angles, 25mmX25mmX4mm including welding and painting with two coats of synthetic enamel paint cover coat of red oxide primer complete all as specified and directed by Engineer-in-Charge. 172 Fabrication desert cooler stand LXB is equal to the base of desert cooler of capacity 3000 Cum/ Hrs with MS equal angles, 25mmX25mmX4mm including welding and painting with two coats of synthetic enamel paint cover coat of red oxide primer complete all as specified and directed by Engineer-in-Charge. 173 REFRIGERATOR & ACSupply, install, testing and commissioning of 400 ltrs capacity refrigerator, double door frost free, R-134a refrigerator, five star rated, 230V AC, 50Hz cycle with accessories & non CFC refrigerant etc complete all as specified and directed by Engineer-in-Charge. 174 Supply, installation, commissioning of Water cooler having fullystainless steel body, electric driven single phase having approxnominal cooling capacityand storage capacity 40/80 Ltr with standard fittings such as supply cord, SS push cock, SS tray, float valve, inlet PCV pipe, drain pipe including connecting to incoming water lines complete all as specified and directed by Engineer-in-Charge. 175 Supply, installation, commissioning of Water cooler having fully stainless steel body, electric driven single phase having approx nominal cooling capacityand storage capacity 120/60 Ltr with standard fittings such as supply cord, SS push cock, SS tray, float valve, inlet PVC pipe, drain pipe including connecting to incoming water lines complete all as specified and directed by Engineer-in-Charge. 176 Hot and cold water dispenser of capacity 4.1 ltrs with cold water storage tank 3.1 ltrs and hot storage tank 1.0 ltrs with cooling capacity 3.0 ltrs/hrs and heating capacity 5.0 ltrs/hrs, single phase 230 volt, 50 Hz including power consumption for cooling 120w and heating power consumption 500w with 2 nos of dispenser bottle complete all as specified and directed by Engineer-in-Charge. 177 Supply, install, testing and commissioning of dual inverter type split type air conditioner 1.5 TR capacity of 5 star rating with cordless remote control, single phase, 240 volts complete with all accessories such as indoor and outdoor units and refrigerant tubing of adequate length as required at site, indoor mounting plate, outdoor mounting bracket made of mild steel duly powder coated fixing with anchor bolts ot any height, drain pipe of suitable size brought to ground level from any height including initial fitting of refrigerant gas, including making round hole on existing wall for taking up refrigerant, tubing, drain pipe and cables etc and making good the disturbed surface by matching with existing adjoining surfaces and fix factory fabricated mild steel stand suitable for installation of outdoor unit of split type air conditioner fixing arrangement with anchoring bolts on wall surfaces at suitable height as per site condition complete all as specified and directed by Engineer-in-Charge. 178 Supply, install, testing and commissioning of dual inverter type split type air conditioner 2 TR capacity of 5 star rating with cordless remote control, single phase, 240 volts complete with all accessories such as indoor and outdoor units and refrigerant tubing of adequate length as required at site, indoor mounting plate, outdoor mounting bracket made of mild steel duly powder coated fixing with anchor bolts at any height, drain pipe of suitable size brought to ground level from any height including initial fitting of refrigerant gas, including making round hole on existing wall for taking up refrigerant, tubing, drain pipe and cables etc and making good the disturbed surface by matching with existing adjoining surfaces and fix factory fabricated mild steel stand suitable for installation of outdoor unit of split type air conditioner fixing arrangement with anchoring bolts on wall surface at suitable height as per site condition complete all as specified and directed by Engineer-in-Charge. 179 Supply, install, testing and commissioning of dual inverter type split type air conditioner 1 TR capacity of 5 star rating with cordless remote control, single phase, 240 volts complete with all accessories such as indoor and outdoor units and refrigerant tubing of adequate length as required at site, indoor mounting plate, outdoor mounting bracket made of mild steel duly powder coated fixing with anchor bolts at any height, drain pipe of suitable size brought to ground level from any height including initial fitting of refrigerant gas, including making round hole on existing wall for taking up refrigerant, tubing, drain pipe and cables etc and making good the disturbed surface by matching with existing adjoining surfaces and fix factory fabricated mild steel stand suitable for installation of outdoor unit of split type air conditioner fixing arrangement with anchoring bolts on wall surface at suitable height as per site condition complete all as specified and directed by Engineer-in-Charge. 180 Supply only dual inverter type split type air conditioner 1.5 TR capacity of 5 star rating with cordless remote control, single phase, 240 volts complete with all accessories such as indoor and outdoor units and refrigerant tubing of adequate length as required at site, indoor mounting plate, outdoor mounting bracket made of mild steel duly powder coated fixing with anchor bolts at any height, drain pipe of suitable size brought to ground level from any height etc complete all as specified and directed by Engineer-in-Charge. 181 Supply only dual inverter type split type air conditioner 2TR capacity of 5 star rating with cordless remote control, single phase, 240 volts complete with all accessories such as indoor and outdoor units and refrigerant tubing of adequate length as required at site, indoor mounting plate, outdoor mounting bracket made of mild steel duly powder coated fixing with anchor bolts at any height, drain pipe of suitable size brought to ground level from any height etc complete all as specified and directed by Engineer-in-Charge. 182 Supply only dual inverter type split type air conditioner 1TR capacity of 5 star rating with cordless remote control, single phase, 240 volts complete with all accessories such as indoor and outdoor units and refrigerant tubing of adequate length as required at site, indoor mounting plate, outdoor mounting bracket made of mild steel duly powder coated fixing with anchor bolts at any height, drain pipe of suitable size brought to ground level from any height etc complete all as specified and directed by Engineer-in-Charge. 183 Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170V to 250V with output Voltage stabalized at 230V with accuracy + 2.5% and of capacity 4.0 KVA complete all as specified and directed by Engineer-in-Charge. 184 Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170V to 250V with output Voltage stabalized at 230V with accuracy + 2.5% and of capacity 3.0 KVA complete all as specified and directed by Engineer-in-Charge. 185 TV/ TELE/ LAN CONDUITRigid non metalic PVC conduit exclusive of boxes (Junction /Terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accssories such as couplers, lock nuts, saddles, pipe hocks etc of external dia 25 mm for laying of TV cables complete all as specified and directed by Engineer-in-Charge. 186 TV Co-axial socket 1 module, complete all as specified and directed by Engineer-in-Charge. 187 Modular Telephone socket outlet on the existing Modular plate & switchincluding connection but excluding modular plate etc complete all as specified and directed by Engineer-in-Charge. 188 Supply, laying, and termination of telephone cable of 0.5mm² multi-core twisted pair copper conductor, PVC insulated, suitable for indoor communication systems, drawn through heavy duty 25mm diameter PVC conduit (ISI marked), including necessary accessories such as bends, junction boxes, tees, saddles, pull boxes, and clamps. The conduit shall be surface mounted or concealed as per site requirements and approved drawings. All works shall be carried out as per specifications, relevant standardscomplete all as specified and directed by Engineer-in-Charge. 189 Supply, laying, and termination of CAT-6 LAN cable with RJ-45 connectors at both ends, suitable for data networking applications. The cable shall be drawn through heavy duty 25mm diameter ISI-marked PVC conduit, complete with all necessary accessories such as bends, tees, junction boxes, saddles, pull boxes, clamps, etc. The conduit shall be surface-mounted or concealed as per site requirements and approved drawings. All terminations shall be made using factory-crimped or field-installed RJ-45 connectors and tested using certified LAN testers. The work shall be carried out in accordance with project specifications, relevant standardscomplete all as specified and directed by Engineer-in-Charge. 190 Supply, installation, and termination of 30-pair Krone type telephone junction box (distribution box) fabricated from powder-coated mild steel (MS) sheet, weather-resistant and suitable for wall or surface mounting. The box shall be equipped with genuine Krone-type disconnection modules, cable entry glands, and internal termination rails to accommodate up to 30 pairs of telephone wires. It shall include all necessary hardware for termination, earthing provision, labeling tags, and fixing accessories. The box should comply with relevant telecom standards and be suitable for indoor/outdoor usecomplete all as specified and directed by Engineer-in-Charge. 191 Supply and installation of modular type RJ-45 data socket (CAT-6 or as specified), complete with shuttered information outlet, faceplate, flush mounting box (metal or PVC), and necessary mounting accessories. The socket shall be compatible with structured cabling systems, suitable for both surface and recessed mounting, and terminated using proper tools as per TIA/ EIA standards. The outlet shall be labeled for identification and tested with a certified LAN tester to ensure proper connectivity complete all as specified and directed by Engineer-in-Charge. 192 EOT CRANESupply and installation EOT crane of capacity 5 Tonne, Double girder EOT crane suitable for 30 Mtrs span floor operated, Lift 7 Mtrs hook height, bay length 40 mtr and bldg height 10.5 mtr, electrically operated hoist overhead, complete with as per functional requirement of workshop and testing complete all as specified and directed with following accessories:-(A) TYPE AND CLASS OF CRANE : Indoor duty, EOT Crane,i) Crane structure Push Button operated, Double Girder Class-III.ii) Hoist : Class-III as per IS:807 & 3177iii) Cross Traverse : Class-III as per IS:807 & 3177iv) Long Travel : Class-III as per IS:807 & 3177(B) SAFE WORKING LOAD : Main Hoist : 5 TONNES(C) CENTRE TO CENTRE OF GANTRY TRACK : 30 METERS (approx)(D) OPERATING SPEEDS (LOADED) :i) Main Hoist : 3-4 M/minii) Cross Travel : 10-15 M/miniii) Long Travel : 15-20 M/miniv) Micro Speed (Hoist) : All motors are equipped with V.F.D to achieve variable speeds. 193 (E) MINIMUM WORKING CLEARANCES REQUIREDa) Distance from centre of Gantry Rail to nearest side obstruction (A) : 0.35M; (B) : 0.35 Mb) Vertical distance from top of Gantry Rail to nearest side obstruction ...... C ..... : 1.6 METERSc) Distance from floor to top of gantry rail ...... D ..... : 7.5 Meters (approx)d) Nearest position of hook to : centre line of Gantry Rail, DSL End : 0.80 METERS and Other End : 0.80 METERSe) Vertical clearance to : 6.0 Meters underside of bridge-K(F)TYPE OF HOOK SUPPLIED : C-type plain shank hook, 360 degree swiveling type as per IS 3815(G) HEIGHT OF HOOK ABOVE FLOOR LEVEL : 7 Meters(H) DROP OF HOOK BELOW LEVEL : Nil(J) SECTION OF GANTRY RAIL RECOMMENDED:50x50 sq. bar(K) TYPE OF MAIN GIRDER/LONG TRADEL GIRDERa) Braced, box plate or lattice : Plate box, radiographically girder or MS plate joist tested.b) Riveted or fusion welded : Fusion welded(L) END CARRIAGESa) Wheel base : Min 3800 mmb) Material of travelling wheels : FORGED STEELc) Maximum load excluding impact : 6.25 Tonnes on travelling wheels. 194 (M) TYPE OF PLATFORM PROVIDED NUMBER : Full length on one side and two short platform on other side with two tiered guard railing of 25 mm dia pipe.(N) CRAB :a) Centre of traverse wheels : 1100 mmb) Materials of traverse wheels : FORGED STEEL(O) HOISTING ROPEDiameter Construction Quality No of Minimum (mm) steel Falls breaking strength Main Hoist 12 mm 6 x 36 FACTOR OF SAFETY : Hoist : 6 Min(P) DESCRIPTION OF BRAKE a) Hoisting motion brakes : Electro Hydraulic Thruster operated (Fail Safe Type)b) Traversing Brakes (s) : Electro Hydraulic Thruster operated (Fail Safe Type)c) Travelling Brakes (s) : Electro Hydraulic Thruster operated (Fail Safe Type)(Q) POWER SUPPLY : AC, 415 Volt, 3 Phase, 50 Hz, 3 wire.(R) MOTORS : Temperature rise : As per IS:325 for ambient 50ºCMain Hoist : 5 HP/Sq.cage/150 sts/hr/40% CDF x 1 NoLong Travel : 3 HP/Sq.cage/150 sts/hr/40% CDF x 2 NoCross Travel : 2 HP/Sq.cage/150 sts/hr/40% CDF x 1 NoMicro Hoist : All motors are equipped with V.F.D to achieve variable speeds. 195 (S) DETAILS OF CONTROLLERS & EQUIPMENT: Push button operated from ground with all required electrical equipment.(T) PARTICULARS OF SAFETY DEVICESa) Limit switches on all motionsb) Mechanical & Electrical interlockc) Wheel stops for CT wheelsd) Axle lugse) Safety buffersf) HRC fuses and overload relays(U) Wheels : Double flanged ,En9 forged (heat treated) flame proof(V) Type of current collecting system for:- (a) Long Travel motion - 100 A GI Shrouded bus bar (b) Cross Travel motion - Fastoon FRLS cablesNote :- Quoted Rates are includes for working of EOT cranes in all respects, painting of all parts of EOT cranes , tesing after completion and also for long tradel girder suitable size.Make of EOT crane: Pioneer/ Dinesh Enterprises/ Kone Cranes/ Mukund Crane 196 Supply and installation EOT crane of capacity of 2 Tonne Double girder EOT crane suitable for 30 Mtrs span floor operated, Lift 7 Mtrs hook height, bay length 40 mtr and bldg height 10.5 mtr, electrically operated hoist overhead complete with as per functional requirement of workshop and testing complete all as specified and directed with following accessories:-(A) TYPE AND CLASS OF CRANE : Indoor duty, EOT Crane,i) Crane structure Push Button operated, Double Girder Class-IIIii) Hoist : Class-III as per IS:807 & 3177iii) Cross Traverse : Class-III as per IS:807 & 3177iv) Long Travel : Class-III as per IS:807 & 3177(B) SAFE WORKING LOAD : Main Hoist : 2 TONNES(C) CENTRE TO CENTRE OF GANTRY TRACK : 30 METERS (approx)(D) OPERATING SPEEDS (LOADED) :i) Main Hoist : 3-4 M/minii) Cross Travel : 10-15 M/miniii) Long Travel : 15-20 M/miniv) Micro Speed (Hoist) : All motors are equipped with V.F.D to achieve variable speeds. 197 (E) MINIMUM WORKING CLEARANCES REQUIREDa) Distance from centre of Gantry Rail to nearest side obstruction (A) : 0.35M; (B) : 0.35 Mb) Vertical distance from top of Gantry Rail to nearest side obstruction ...... C ..... : 1.6 METERSc) Distance from floor to top of gantry rail ...... D ..... : 7.5 Meters (approx)d) Nearest position of hook to : centre line of Gantry Rail, DSL End : 0.80 METERS and Other End : 0.80 METERSe) Vertical clearance to : 6.0 Meters underside of bridge-K(F)TYPE OF HOOK SUPPLIED : C-type plain shank hook, 360 degree swiveling type as per IS 3815(G) HEIGHT OF HOOK ABOVE FLOOR LEVEL : 7 Meters(H) DROP OF HOOK BELOW LEVEL : Nil(J) SECTION OF GANTRY RAIL RECOMMENDED: 40x40 sq. bar(K) TYPE OF MAIN GIRDER/LONG TRADEL GIRDERa) Braced, box plate or lattice : Plate box, radiographically girder or MS plate joist tested.b) Riveted or fusion welded : Fusion welded(L) END CARRIAGESa) Wheel base : Min 1400 mmb) Material of travelling wheels : FORGED STEELc) Maximum load excluding impact : 4 Tonnes on travelling wheels. 198 (M) TYPE OF PLATFORM PROVIDED NUMBER, : Full length on one side and two short platform on other side with two tiered guard railing of 25 mm dia pipe.(N) CRAB :a) Centre of traverse wheels : 1100 mmb) Materials of traverse wheels : FORGED STEEL(O) OISTING ROPEDiameter Construction Quality No of Minimum (mm) steel Falls breaking strength Main Hoist 12 mm 6 x 36 FACTOR OF SAFETY : Hoist : 6 Min(P) DESCRIPTION OF BRAKE a) Hoisting motion brakes : Electro Hydraulic Thruster operated (Fail Safe Type)b) Traversing Brakes (s) : Electro Hydraulic Thruster operated (Fail Safe Type)c) Travelling Brakes (s) : Electro Hydraulic Thruster operated (Fail Safe Type)(Q) POWER SUPPLY : AC, 415 Volt, 3 Phase, 50 Hz, 3 wire.(R) MOTORS : Temperature rise : As per IS:325 for ambient 50ºCMain Hoist : 3 HP/Sq.cage/150 sts/hr/40% CDF x 1 NoLong Travel : 3 HP/Sq.cage/150 sts/hr/40% CDF x 2 NoCross Travel : 1 HP/Sq.cage/150 sts/hr/40% CDF x 1 NoMicro Hoist : All motors are equipped with V.F.D to achieve variable speeds. 199 (S) DETAILS OF CONTROLLERS & EQUIPMENT: Push button operated from ground with all required electrical equipment.(T) PARTICULARS OF SAFETY DEVICESa) Limit switches on all motionsb) Mechanical & Electrical interlockc) Wheel stops for CT wheelsd) Axle lugse) Safety buffersf) HRC fuses and overload relays(U) Wheels : Double flanged, En9 forged (heat treated) flame proof(V) Type of current collecting system for:- (a) Long Travel motion - 100 A GI Shrouded bus bar (b) Cross Travel motion - Fastoon FRLS cablesNote :- Quoted Rates are includes for working of EOT cranes in all respects, painting of all parts of EOT cranes, tesing after completion and also for long tradel girder suitable size.Make of EOT crane : Pioneer/ Dinesh Enterprises/ Kone Cranes/ Mukund Crane 200 Supply and laying in trenches or fixing to wall/ pole or passing through pipe, XLPE insulated heavy duty electric cable with aluminium conductor 1100 volts grade cross sectional area 50 Sqmm 3.5 core. Note :1. Quoted rates included for making good all distributed wall surfaces/ flooring/ tilling to match with existing specifications. 2. Excavation and earth work, sand cushioning, brick covers and GI pipe shall be measured and paid separately under respective items. 201 Mild steel works as in roof trusses (framed), trussed, purlins, crane gantries, rails Fe 410-W (Gde E-250) quality A and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc complete all as specified and as directed by Engineer-in-Charge. 202 Note: The schedule of credit has been attached in tender in Pdf format as Sch A Part-XVI and amount of credit schedule i.e. Rs 25,150.00 shall be deducted from the total amount of BOQ to arrive at the contract sum.