}

Supply Installation Testing And Commissioning Of Ac Machines With Allied Electrical Works For Usg Machine At Fetal Medicine Unit, Maternity Ground Floor Gynae Building, Ipgmer-Sskm(H) Kolkata(Electrical Work), kolkata-West Bengal

Public Works Department has published Supply Installation Testing And Commissioning Of Ac Machines With Allied Electrical Works For Usg Machine At Fetal Medicine Unit, Maternity Ground Floor Gynae Building, Ipgmer-Sskm(H) Kolkata(Electrical Work). Submission Date for this Tender is 22-09-2025. Air Conditioner Tenders in kolkata West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

51152098
Supply Installation Testing And Commissioning Of Ac Machines With Allied Electrical Works For Usg Machine At Fetal Medicine Unit, Maternity Ground Floor Gynae Building, Ipgmer-Sskm(H) Kolkata(Electrical Work)
Tender
Indian
West Bengal
Kolkata
22-09-2025
BootCamp

Tender Details

supply installation testing and commissioning Of Ac Machines With Allied Electrical Works For Usg Machine At Fetal Medicine Unit, Maternity Ground Floor Gynae Building, Ipgmer-Sskm(H) Kolkata(Electrical Work)- 1 S&F double door Horizontal TPN MCB DB with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl interconnection with suitable size of copper wire and neutral link & provision for earthing attachment(Legrand/ Siemens/ Schneider) - 6 way 2 S&F double door SPN MCB DB with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl interconnection with suitable size of copper wire and neutral link & provision for earthing attachment(Legrand/ Siemens/ Schneider) - 2+12 way 3 S & F 250V 25A Dual Timer controller for AC machine in SS double door 2+16 way DB enclosurewith S&F following electrical accessories & front door locking arrangement with all connection by finishing the ends of 2x4 & 1x2.5 copper wire dowells solderless socket by crimping method as to GS earthing attachment on wall incl necessary connections as per direction of EIC :- (Make:- L&T).a) 40 A DPMCB (Legrand) - 1 no.b) 20A DP MCB (Legrand) - 2 no.b) 24 Hr programmable Digital timer (L&T Cat No: 67DDT0) - 1 no.c) 3 pole 25A power contactor with NO&NC (ABB/) - 2 nos.d) 2 module AC motor starter (Legrand Myrius Cat no-673031)-2 no.e) 1 module 16 A Modular switch (Legrand Myrius) - 2no.f) 3 module cover plate (Legrand Myrius) - 2 no.g) LED indicator lamp (L&T) - 2 nosh) Outgoing Connector(aproved reputed make) - 2 nos.i)25 A Auto-Off-Bipass DPDT toggle switch - 2 nos. to be fixed on iron frame. 4 S&F 240/415V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necy connection [Legrand/ Siemens/ Schneider)]6-32A SP 5 63A FP 6 40A DP 7 Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded FRLSH PVC insulated & unsheathed copper wire (Polycab/ Havells/Gloster/ Finolex) in 20mm size PVC rigid conduit FR (Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded FRLSH PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Piano Key type switch fixed on MS CRC sheet metal (16SWG) switch board cum JB on wall complete with 2no. suitable size “Ph&N” copper bar incl. bakelite/Perspex (wall matching color) top cover 3 mm thick and incl. 175mmx100mmx65mm inspection box, making earthing attachment, painting the MS box and mending goodthe damages to original finish(iii) average run 8 mtr 8 Supply & Fixing 240 V, 3 nos. 6A, & 1 no. 20A plug socket with separate 3 nos. 6 A & 1 no. 20A Piano key type switch, indicator & 20A switch type SP MCB (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S &F 240x200x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/ perspex cover and making necessary connections as required 9 Supply & Fixing 240 V, 20 A plug socket (Brand approved by EIC), without plug top and switch, on existing sheet metal switch board with bakelite/ perspex top cover by screws after making housing for combined plug switchby cutting bakelite/perspex top cover andmaking necy. connections with PVCwire and earth continuity wire etc. 10 S&D 1.1KV single core stranded FR PVC insulated & unsheathed single core stranded copper wire (Polycab/ Havells/Gloster/ Finolex) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy connection as required. 11 2x36/0.3 (2.5sqmm) + 1x22/0.3 (1.5sqmm) ECC 12 2x56/0.3 (4 sqmm) + 1x36/0.3 (2.5 sqmm) as ECC 13 2x84/0.3 (6sqmm) + 1x56/0.3 (4sqmm) as ECC 14 4x80/0.4 (10 sqmm) + 2x84/0.3 (6 sqmm) as ECC 15 S&F PVC rigid conduit FR [Precision Make] on wall, ceilling with saddles and other accessories as required and mending good damages to building works20mm size 16 25mm size 17 Finishing of the PVC insulated wire ends by socketing with pin/ring type copper sockets and insulated tapes etc including supplying sockets tapes 18 6sqmm 19 4sqmm 20 2.5sqmm 21 10sqmm 22 Supply and Delivery of 4 feet Industrial box type twin LED tube fitting incl. Supply & Delivery of 2 no. 240V, 20 W LED Tube (Polycarbonate with heat sink) with glare free light distribution with CCT (5000K-6500K) having minimum luminous efficiency of 105 Lm/ Watt or better & 50,000 LED burning hours or more. [Make- Philips/ Lighting Technology/ Wipro or manufacturer with own NABL accredited lab with valid test certificate] [LED lamps & accessories shall have BEE certification] 23 Fixing only single/twin fluroscent light fittings complete with all accessories directly on wall / ceilling with HW block and suitable size MS fastener, ceiling plate, nipples etc as required 24 Fixing only single/twin fluorescent light fitting suspended 25 cmbellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG)supports fixed with “L” type MS clamp whose one side fixed onceiling with sutable size 4 nos. fastener and other side connectedwith the conduit with suitable size of bolts and nuts incl. S&F EIconduit, “L” type (125mmx125mm) 6mm thick and 25mm with MSclamps and connecting the length of PVC insulated wire andmending good damages to original finish and painting etc. by2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length. 25 Supply and fixing of Sintex make loop box with 2pole 32A MCB with necessary connection complete. 26 Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry ofXLPE/PVC armoured cables as below :4C35Sqmm 27 Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials 4C35sqmm 28 Add GST @18% 29 Add LWC@1% 30 Less: cost for the existing old panel as it is installed at Gynae OPD Passage. @ Rs. (-10000.00) 31 Make & model of each and every material to be approved by EIC. 32 Defect Liability Period - 1 (One) year

Key Value

Document Fees
Refer document
Tender Value
INR 2.20 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail