| 1 | H-Beams 152 X 152 mm., 37.1 Kg./Mtr.-9 mtr. Long= 333.9 kg |
| 2 | 140 Kg.,8.0 Mtrs. long PCC pole |
| 3 | 280 Kg.,9.1 Mtrs. long PCC pole |
| 4 | 11 KV Pin Insulator Polymer Composit (5 KN) |
| 5 | 11 KV Strain hardware (T&C type) fittings |
| 6 | 11 KV Top clamp 65X65X6 mm. angle type |
| 7 | 11 KV VCB, Outdoor Porcelain clad type with complete structure and accessories excluding CT & pannel |
| 8 | 11 KV(45KN) Composite Polymer Disc Insulators |
| 9 | 11 KV, ISOLATOR 800 AMP.(Turn and twist type) |
| 10 | 11 KV.C.Ts.(Outdoor dry type) 300-150/5-5 Amps |
| 11 | 33 KV (45KN) Composite Polymer Disc Insulators |
| 12 | 33 KV composite polymer Strain set with hard ware suitable for Panther Conductor |
| 13 | 9 KV Gapless type(5 KA) polymer lightening arrestor |
| 14 | AAAC Dog conductor 0.10 sq. inch (100 sq.mm. Al.Eq.) |
| 15 | AAAC Raccoon conductor 0.075 sq. inch (80 sq.mm. Al.Eq.) |
| 16 | ACSR Panther conductor 0.20 sq. inch (200 sq.mm Al.Eq.) |
| 17 | Copper Control Cable 12 Core. 2.5 Sq.mm. (Unarmoured) |
| 18 | Copper Control Cable 2 Core. 2.5 Sq.mm. (Unarmoured) |
| 19 | Copper Control Cable 4 Core. 2.5 Sq.mm. (Unarmoured) |
| 20 | Copper Control Cable 8 Core. 2.5 Sq.mm. (Unarmoured) |
| 21 | M S Angle 65X65X6 mm |
| 22 | M S Channel 100X50x6 mm |
| 23 | 3 phase 4 wire 3x63.5 volts lb=5 amps Imax = 10 amp, HT trivector meter class of accuracy 0.5s, DLMS Compliant category A Meters along with GSM (GPRS compatible ) modems (For substation metering) |
| 24 | Aluminium Binding wire and tape |
| 25 | Aluminium paint |
| 26 | Anti climbing devices ( Barbed wire 2.24 mm dia, 14 SWG) |
| 27 | Back Clamp for 140 Kg PCC Pole MS Flat 50x6 mm |
| 28 | Back Clamp for 280 Kg PCC Pole of MS Flat 65x8mm.(Each weight 1.92 Kg) |
| 29 | Back filling of poles with boulders. |
| 30 | Bentonite compound powder |
| 31 | Carpet guarding |
| 32 | Clamp for 140 Kg PCC Pole MS Flat 50x6 mm |
| 33 | Clamp 65X8 mm Flat of MS Flat for H-Beam ( Each weight 3.2 kg) |
| 34 | Clamp 65X8 MM of MS Flat for pcc Pole 280Kg. (Each weight 3.04 kg ) |
| 35 | Concreting of foundation of VCB (1:3:6) @ 3.5 cmt per VCB plinth |
| 36 | Concreting of stay (16 mm / 12 mm) @ 0.2 Cmt. per stay |
| 37 | Concreting of stay (20 mm / 25 mm) @ 0.3 cmt. per stay |
| 38 | Concreting of structures & foundation (1:3:6) |
| 39 | Danger Boards Enamelled 11 KV |
| 40 | Danger Boards Enamelled 33 KV |
| 41 | Earthing Coil of 115 Turns of 50 MM.Dia and 2.5 Mtr. Lead of 4.0 MM G.I Wire |
| 42 | Earthing for PCC Pole 4.00 mm-8 SWG G.I wire- 0.8 Kg, per pole |
| 43 | Erection of Plinth per VCB- 33KV or 11KV |
| 44 | G.I. STRIP 25X3 MM1 |
| 45 | G.I. WIRES 4.0 MM. (8 SWG) |
| 46 | G.I.Pipe 40 mm Dia C grade type |
| 47 | Galvanized nut & bolt with washer |
| 48 | Jointing Sleeves suitable for Dog (100Sq.mm.Al. Eq. ) AAAC conductor |
| 49 | Jointing Sleeves suitable for Rabbit (55Sq.mm.Al. Eq. ) AAAC conductor |
| 50 | M.S.Nuts with Bolts |
| 51 | MS strain plate 65x8mm 250mm long |
| 52 | Red oxide paint |
| 53 | STAY GI WIRE 7/4.00 MM.(7/8 SWG) |
| 54 | Stay Insulators 90X65mm |
| 55 | Stay set 20 mm. complete without Stay wire (Painted) |
| 56 | Stay set complete without Stay wire 16 mm. (Painted) |
| 57 | STAY WIRE 7/3.15 MM.(7/10 SWG) |
| 58 | Stone Block/Pre cast block for base pedding(450X450X75MM) |
| 59 | Stringing of Each 11 KV Bus-upper and lower bus including, drop jumpering and jointing with clamps,through outgoing VCB/ ME/ DP, upto station transformer |
| 60 | T CLAMP FOR 33KV & 11KV BUS, SUBSTATION upto DOG |
| 61 | Lebour Charge for Compny Side Material |
| 62 | Lebour Charge for Compny Side Material paide to Cont. % |
| 63 | SGST @ 9% |
| 64 | CGST @9% |