Tender For Provn Of Ht And Lt Ring Main Unit (Rmu) At 7 Afh Kanpur; 1 Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits,manholes, pier holes, for laying of UG Cable etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil complete all as specified & directed by Engr-in-Charge 2 Returning filling in includingspreading leveling watering and well ramming in layers not exceeding 25 cm in soft/loose soil complete all as specified & directed by Engr-in-Charge 3 Removing excavated material n.exc. 50m and depositing where directed at a level n.exc 1.5 m above starting point complete all as specified & directed by Engr-in-Charge. 4 Material and labour for Double wall corrugated Duct pipe,Orange Colour (450 N), ISI marked (IS16205 (Part -24) (Electrical Use) of outer dia 110 mm, inner dia 95 mm with smooth internal and profiled external surface, non-pressure laid in trenches/floors/duct or fixed on walls /pole including all connections, accessories like socket, couplers, bends, etcfor protection of HT cable XLPE grade 11000 volts complete all as specified and directed by Engineer-in-Charge. 5 M&L for boring hole under the road/pavement /hard standing with the help of trenchesless technology using ultra sound technique and necessary machine complete including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure not less than one metre below ground level complete all as specified & directed.Note : HDPE pipe of 150 mm diawill be deemed to be included in the quoted rate.Contractor should be quote the rate including HDPE pipe 150 mm medium grade. 6 Supply ,laying and testing XLPE insulated , screened, PVC bedded galvanised steel strip or wire armoured HT electric power cable heavy duty with aluminium conductor 11000 volts grade earthed cross sectional 120 sq mm 3 core, laid in trenches/ducts /encased in pipe completed all as specified and directed. NoteCost of fixing accesories for laying in ducts is included in quoted rates. 7 S&F HT 11 KV bus bar chamber ( 90cm x 45cm x 150 cm) outdoor type weather and vermin proof factory fabricated CPRI approved duly painted with two coat of enamelled paint, pedestal type made out of mild steel sheet 3.15mm thick, factory made,using angle iron 50mm x 50mm x 6mm and 500mm high from GL, front opening double shutter weather proof , rust proof, dust proof with provision of rubber gasket and locking arrangement including HT bush, Post insulator & Aluminium bus bar with color code - 03 Nos (Suitable for fixing of 120 Sqmm HT Cable),Danger Notice Board with skull sign & Voltage indication in front side of Panel,cable gland of suitable size for cable entry & exit and making connection with suitable size of thimbles, nuts, bolts and washers etc incl necessary earth work. for fixing of Bus bar chamber at ground completed all as specified & directed by Engr-in-Charge. 8 Supply and fixingcable end jointing kit for 11 KV grade cable for indoor termination heat shrink type joint complete with jointing material and all accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm. completed all as specified & directed by Engr-in-Charg 9 Supply andfixing cable end jointing kit for 11 KV grade cable for Outdoor termination heat shrink type joint complete with jointing material and all accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm.completed all as specified & directed by Engr-in-Charg 10 Supply andfixing Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm. completed all as specified & directed by Engr-in-Charg 11 Supply, installation, commisioning and testing of 11KV, 630A, 21KA, 3sec motor operated, compact gas insulated for outdoor application with IP-67 class of protection with SS 304 grade tank, impulse withstand voltage of 75 kV, insulation level of 28 kV (@power frequency of 1 min), control voltage 24V DC for motor operation, fully rated with earth switch, spring assisted mechanism, Arc proof type cable cover interlocked with Earth Switch, Red/Green Push button for On/Off Operation, capacitive voltage indication fixed type with aux contact, The VCB of RMU must have duty class of E2, M2 & C2 with 10000 mechanical operations(Type test report required at the time of drawing submission). Make of VCB and VI should be of same make for better optmization, suitable rating CTs and boots suitable for bottom entry front/ side / rear termination of 3 core cable 120-240 Sqmm, both side extendible non- draw out type Ring Main Unit having interlocking facility & internal arc tested with 21kA for 1s in cable & tank compartment (type test reports required along with drawing) with following details.(03 Module HT Switchgear RMU 3 way(having 02 LBS & 01VCBs) from OEM factory only.(a) Incoming : (i) Incomer No.1:- 01 No., 630 Amp motorized Load break switch triple pole, single break 3 position as incomer (On, Off and earth having STC capacity 21KA for 3 seconds with copper bus bar and copper earth bar as per IEC 61958-1, earth fault indicator.(ii) Incomer No.2:- 01 No., 630 Amp motorized Load break switch triple pole, single break 3 position as incomer (On, Off and earth having STC capacity 21KA for 3 seconds with copper bus bar and copper earth bar as per IEC 61958-1, earth fault indicator.(b) Outgoing: (i)Outgoing No. 1:- 01 No., 630 Amp motorized Vaccum circuit breaker triple pole, single break 3 position with duty class of E2, M2, C2 with 10000 mechanical operations as outgoing (On, Off and earth having STC capacity 21KA for 3 seconds with copper bus bar and copper earth bar as per IEC 61958-1, cable bushings, shunt trip control, busbar cover, ring core current transformer of ratio 50/1 A.Note 1 -Foundation work as per OEMs recommendation is deemed to be included in the quoted rates for installation of RMU.Note 2 -Units shall be SCADA compatible. Note 3 - Drawing to be submitted for approval to GE before procurement of Item. 12 Supply, installation, commisioning and testing of 11KV, 630A, 21KA, 3sec motor operated, compact gas insulated for outdoor application with IP-67 class of protection with SS 304 grade tank, impulse withstand voltage of 75 kV, insulation level of 28 kV (@power frequency of 1 min), control voltage 24V DC for motor operation, fully rated with earth switch, spring assisted mechanism, Arc proof type cable cover interlocked with Earth Switch, Red/Green Push button for On/Off Operation, capacitive voltage indication fixed type with aux contact, The VCB of RMU must have duty class of E2, M2 & C2 with 10000 mechanical operations(Type test report required at the time of drawing submission). Make of VCB and VI should be of same make for better optmization, suitable rating CTs and boots suitable for bottom entry front/ side / rear termination of 3 core cable 120-240 Sqmm, both side extendible non- draw out type Ring Main Unit having interlocking facility & internal arc tested with 21kA for 1s in cable & tank compartment (type test reports required along with drawing) with following details.(03=5 Module HT Switchgear RMU 5 way(having 02 LBS & 03 VCBs) from OEM factory only. (a) Incoming : (i) Incomer No.1:- 01 No., 630 Amp motorized Load break switch triple pole, single break 3 position as incomer (On, Off and earth having STC capacity 21KA for 3 seconds with copper bus bar and copper earth bar as per IEC 61958-1, earth fault indicator.(ii) Incomer No.2:- 01 No., 630 Amp motorized Load break switch triple pole, single break 3 position as incomer (On, Off and earth having STC capacity 21KA for 3 seconds with copper bus bar and copper earth bar as per IEC 61958-1, earth fault indicator.(b) Outgoing: (i)Outgoing No. 1:- 01 No., 630 Amp motorized Vaccum circuit breaker triple pole, single break 3 position with duty class of E2, M2, C2 with 10000 mechanical operations as outgoing (On, Off and earth having STC capacity 21KA for 3 seconds with copper bus bar and copper earth bar as per IEC 61958-1, cable bushings, shunt trip control, busbar cover, ring core current transformer of ratio 50/1 A. (ii)Outgoing No. 2:- 01 No., 630 Amp motorized Vaccum circuit breaker triple pole, single break 3 position with duty class of E2, M2, C2 with 10000 mechanical operations as outgoing (On, Off and earth having STC capacity 21KA for 3 seconds with copper bus bar and copper earth bar as per IEC 61958-1, cable bushings, shunt trip control, busbar cover, ring core current transformer of ratio 50/1 A.. (iii) Outgoing No. 3:- 01 No., 630 Amp motorized Vaccum circuit breaker triple pole, single break 3 position with duty class of E2, M2, C2 with 10000 mechanical operations as outgoing (On, Off and earth having STC capacity 21KA for 3 seconds with copper bus bar and copper earth bar as per IEC 61958-1, cable bushings, shunt trip control, busbar cover, ring core current transformer of ratio 50/1 A.Note 1 -Foundation work as per OEMs recommendation is deemed to be included in the quoted rates for installation of RMU.Note 2 -Units shall be SCADA compatible.Note 3 - Drawing to be submitted for approval to GE before procurement of Item. 13 Supplying and laying synthetic Rubber insulated mats 5 mm thick for voltage upto 11.0 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m complete all as specified and as directed. 14 Supply and fix CI cable route indicator 150mm dia , 5mm thick duly engraved with HT 11000 volts and bolted/welded to MS angle iron of size 40x 40x5 mm,70 cm long,50cm above ground level and 20 cm below ground, painted with 2 coats of synthetic enamel paint using approved colour over a coat of red oxide primer. The route indicator should begrouted in PCC using (1:2:4) type B-1 of size 150x100mm below the ground level completeall as specified and as directed by Engr-in-chargeNote:- Route markers are to be fixed at a distance from each other all as directed. 15 M & L for earthing complete with GI earth plate electrode of size 600 mm x 600 mm x 6 mm thick buried directly to ground vertically to a depth not less than 2.25 Mtr below the ground level with top edge of earth plate not less than 1.5 Mtr below normal ground level connected to GI strip 32mm x 6 mm as earthing lead protected with 50mm dia light grade GI pipe, filling around with charcoal dust and salt including excavation, returning filling of earth work and disposal of surplus soil to a distance not exceeding 50 mtr and connected to GI strip by means of GI nuts, bolts and washers strip connected to earth plate including chamber PCC 1 : 3 : 6 type C-1 using 20mm graded stone aggregate and pre cast RCC cover 40 mm thick reinforced with 6 mm dia round at the rate of 75 mm C/C both way with 12 mm dia mild steel plain bar lifting handle 2 Nos funnel with wire mesh, 20 mm dia GI pipe light grade watering pipe and framework complete all as specified and as directed.Note:- GI strip above 7.5m length shall be measured & paid separately. 16 Supply and fixing GI strip 32 x 6 mm for extension of earth and connected to equipment / panel / RMU etc. complete all as specified and directed.