Tender For Provision Of Certain Minor And Revenue Work At Mil Stn Sgnr.; 1 Excavation in post holes (or similar holes) each n exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance n exc 50 m and making good surface complete all as specified and directed. 2 M&L PCC 1:3:6, Type C2 (using40mm graded stone aggregate) as in filling of post hole complete all as specified and directed. 3 M&L for steel work in tubular trusses ,channels , including special shaped washer, platesnuts and bolts, gusset plates,including necessary drillingetc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 complete all as specified and directed. 4 M&L for preparation of new steel surfaces of any description, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide complete all as specified and directed. 5 S & F Flat ironfor wind ties,plates (plain or chequered) channels, posts, square cut or notched (ordinary and counter sunk) forming holesetcFe 410 -W (Gde- E- 250) quality- A complete all as specified and directed. 6 S&F mild steel screw bolts (machine made) with hexagonal or square head at one end, and screwed the other,or screwed bothend to be fitted with washer and one hexagonal/ square nut not exceeding 5cm long and dia of neck 11 to 15mm complete all as specified and directed. 7 S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. 8 S&F pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. 9 M&L for surface dressing n exc 15 cm deep in soft/loose soil complete all as specified and directed. 10 Removal of excavated material soil not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed. 11 M&L for hardcore of broken bricks of gauge exc 63mm n.exc 100mm, deposited, spread and levelled in layers n.exc 15cm thick, watered and rolled /rammed to true surface complete all as specified and directed. 12 M&L 100 mm thick cement concrete type D2, 1:4:8 (Using 40mm graded stone aggregate) in sub floors, sub floors, sub bases floors and pavingscomplete all as specified and directed. 13 M & L for25 mm thick type B-0, 1:2:4 (12.5mm graded aggregate) finishing cement concrete surface even and smooth without using extra cement complete all as specified and directed. 14 Excavation in trenches not exceeding 1.5 Mtr wide and not exceeding 1.50 Mtr in depth for foundation, etc., not exceeding 10 Sqm on plan in soft /loose soil & getting out complete all as specified and directed. 15 As per Srl item No. 14 above but exc 1.50m but not exc 3.00m in depth complete all as specified and directed. 16 Excavation in trenches not exceeding 1.5 mtr wide and not ecxceeding 1.5 mtr depth for laying of cables including taking up or down the LT cable complete all as specified and directed. 17 Returning, filling in, including spreading, leveling, watering and well ramming in soft/loose soil in layer not exceeding 25 cm thick complete all as specified and directed. 18 M & L forPCC 1:4:8 type, D2 (40mm graded stone agg.) as inmass concretein foundations, surface drains walls, retainting wall etc complete all as specified and directed. 19 M&L brick work withsub class `B Bricks, straight or curved on plan exc 6m meanradius, built in CM 1:6 complete all as specified and directed. 20 M & L for75 mm thick PCC 1:3:6 type, C2 (40mm graded stone agg) as inplinth protection complete all as specified and directed. 21 M&L for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and directed. 22 M&L 10 mm thick cement plaster in cement mortar 1:3 on ceiling surfaces finished even and smooth without using extra cement complete all as specified and directed. 23 M&L for brick work with sub class B bricks (old size) straight or curved on plan exc 6 m mean radius built in CM 1:4complete all as specified and directed. 24 Brick work with sub class B brickswall straight or curved on plan exc 6 m mean radius built in CM 1:4in half brick thick complete all as specified and directed. 25 M&L 15mm thick rendering in CM 1:4inside and bottom of the pit to brick/concrete wall surfaces finishedeven & smooth w/o using extra cement complete all as specified and directed. 26 M&L TMTbars as in reinforcement 10 mm dia and over cut to length bent to shape required incl cranking bending spirally for hooping for cols, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90 mm dia using TMT bars complete all as specified and directed. 27 M&L for TMT bar 8 mm dia cut in shape length incl cranking bending etc and binding with and incl MS wire not less than 0.9 mm complete all as specified and directed. 28 M&L 5mm dia and over upto 10mm dia in stirrups,spacers and binders complete all as specified and directed. 29 Forming embankments including raising (or lowering) earth, spreading in layers n exc. 30 cm thick; watering,ramming/ rolling and finishing to required size, shape, etc., n exc. 1.5m high from base complete all as specified and directed. 30 M&L for RCC M-30 (design mix) in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed. 31 M&L for RCC M-30 (design mix) in wallsretaining walls, basement walls, ballast walls and the like; any thickness; above top of footings; including attached pilasters and buttresses complete all as specified and directed. 32 M&L75 mm thick cement concrete type D2, 1:4:8 (Using 40mm graded stone aggregate)as in sub floors concrete complete all as specified and directed. 33 M&L for sand filling (25mm thick) under floors or in foundations including watering and consolidation complete all as specified and directed. 34 M&L Machine pressed precast concrete interlocking paverblock any shape and size confirming to IS 15658-2006 of 60 mm thickness M-40 Grade complete all as specified and directed. 35 Supply & fixing mild steel clamps made of flat iron 40x6mm in two halves for tapping through upto 100 mm bore GI water pipe line including drilling and welding of 20/25mm GI socket and necessary rubber insertion, nut, bolts & washers complete all as specified and directed. 36 M&L for galvanized steel water tubing medium grade of 25mm bore with & including all fittings complete, laid in trenches, floor or on walls complete all as specified and directed. 37 M&L for galvanized steel water tubing medium grade of 15mm bore with & including all fittings complete, laid in trenches, floor or on walls complete all as specified and directed. 38 Supply and fixing Gun-metal, globe valves ISI marked 25 mm bore, with iron wheel head, flanged ends foriron pipe or for unions complete all as specified and directed. 39 Supply and fixing Gun-metal, globe valves ISI marked 15 mm bore, with iron wheel head, flanged ends foriron pipe or for unions complete all as specified and directed. 40 Supply and install 3 HP heavy duty double cylinder car washer 300 lbs psi, discharge 360 gallon per hour alongwith 3 phase induction motor complete with pump complete including flexible pipe not less than 16 m with Adjustable Nozzle, Belt Guard, In-line filter, Pressure Gauge, Valve Spanner, two Nos V Belts, Motor Pulley and running spare kit complete all as specified and directed. 41 S&F direct on line citation motor starter 415V coil suitable for 3 HP induction motors, overload relay range- 2.4-3.8 Amp, complete with SS enclosure complete all as specified and directed. 42 Supply and fixing sheet metal enclosure MCCB DB TPN 4 wayvertical alongwith necessary fittings and connections complete all as specified and directed. 43 S&F MCCB TPN 63 Amps with breaking capcity 16kA ,Fixed TM and 415 volts AC Supply ISI marked complete all as specified and directed. 44 Supply and fixing TP 20 Amps, 415V 10KA C curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the DB complete with connection testing and commissioning complete all as specified and directed. 45 M&L for boring of size 80 mm under pathways/roads suitable for laying of pipeline of size upto 80mm complete all as specified and directed. 46 M & L for Earthing complete with GI earth plate electrode 60 cm x 60 cm x 6 mmthick burried directly in ground (earth pit not less than 2.25 Mtr deep below ground level ) with top edge of plate not less than 1.5 Mtr below ground level , connecting to GI earth lead 4 mm dia GI earth wire ,by means of bolts,nuts and washers of GIand protection by provisionof GI medium grade pipe 15 mm bore including provision of concrete pit in PCC (1:2:4) type B1 using 20 mm grade stone aggregate with 40 mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4 gs /Sqmm ) and frame of angle iron 25mmX25mmX6mm with lugs 02 Nos and with 6 mm dia MS bar handle made to shape ,GI light grade 20mm bore pipe for watering perforated at the bottom 1.75 meter long placed ontop edge of earth plate common salt and charcoal filling test point made out of 40 mmX 8 mm FI with fixing arrangement ,funnel, wire mesh and earth work inhard dense soil ,returning filling in and removal of surplus soil to a distance not exceeding50 mtrs all as per electric plate no.3 of SSR part 1 and connecting to earth test point including taking out unserviceable earthing with all acessories all as specified or indicated including testing on completion all as specified and directed. 47 M&L for Earthing complete with galvanised iron earth plate electrode of size 600mm x 600mm x 6mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including GI strip 32X6mm (upto the body of equipment) by means ofGI bolts/nuts/washers, protected by 40 mm bore GI light grade pipe. Earth plate shall be surrounded by alternate layer of charcoal or coke and common salt 15 cm thick all around bottom and top. 20 mm bore GI medium grade pipe for watering and including funnel, wire mesh, RCC cover in 1:2:4 type B1using 20mm graded crushed stone aggregate and reinfircement (TMT) with 8mm dia @ 100 c/c bothways & frame, PCC (1:3:6) type C2 (using 20 mm graded crushed stone aggregate) as in earthing pit including necessary excavation & earth work, complete all as specified & shown in electrical plate No. 3 of MES schedule Part-I.Note:(i) The unit rate includes earthing lead & protection pipe upto 7.5 metre from top of earth plate.(ii) PCC chamber shall be construced at least 1.50 m away from the earth electrode and pipe for watering shall be provided in slanting manner. 48 Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 4 corecomplete all as specified and directed. 49 Supply and laying DWC pipe of size 50 mm (OD) bore, ISI marked,laid in trenches, under road, insert under holes for cable protection complete all as specified and as directed.(Note:- Excavation and earthwork as required shall be measured and paid separately under respective item of Sch.) 50 M&L for galvanized steel water tubing medium grade of 80 mm bore with & including all fittings complete, laid in trenches, floor or on walls complete all as specified and directed 51 M&L for galvanized steel water tubing medium grade of 40 mm bore with & including all fittings complete, laid in trenches, floor or on walls complete all as specified and directed 52 M&L for galvanized steel water tubing medium grade of 20 mm bore with & including all fittings complete, laid in trenches, floor or on walls complete all as specified and directed 53 Supply and laying flexible PVC pipe heavy duty 75/80 mm complete all as specifed and directed. 54 S&F of Brass Impact Garden Automatic Rotating Sprinkler with Nozzle Heavy Duty Irrigation Sprayer Head (20mm or 3/4 Inch ) complete all as specified and directed 55 S&F of PVC foot valve size 75/80 mm bore including all material as per IS 4038 complete all as specified and directed 56 Supply, testing & commissioning Monoblock pumpset 5 HP, 415 V , 3 phase with min discharge of 8 litres per second at 8 meters head, with suction pipe bore 80 mm and discharge pipe bore 80 mmincluding foundation work all necessary electric fittings, necessary FRP sheet shed with MS work for motor protection from rain complete all as specified and directed 57 Supply, testing & commissioning Monoblock pumpset 10 HP, 415 V , 3 phase with min discharge of 8 litres per second at 8 meters head, with suction pipe bore 80 mm and discharge pipe bore 65 mmincluding foundation work all necessary electric fittings, necessary FRP sheet shed with MS work for motor protection from rain complete all as specified and directed 58 Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4 core complete all as specified and directed 59 Supply,installation, commissioning in of LT panel (Outdoor type ) board not less than 60cmx60cmx65cm made out of 3.15 mm thick CRCA sheet vermin proof, including painting with sysnthetic enamelled paint, CPRI approved with colour code PVC sleeves for bus bar, front opened with locking arrangement, closed bus bar chameber, angle iron frame of size 50x50x6mm for skeleton and support embeded in concrete foundation comprising of the following :-(a) Copper bus bar 100 amps for phase & neutral-01 No (b)MCCB 4P 63 Amps, 16 KA - 01 Nos (In coming) (c) MCCB 4P 25 Amps, 16 KA - 02 No (O/G) (one spare) (e) Multifunctional meter digital type showing voltage, current, frequency, power factor , Kilo watt, Kilo watt hours with in bulit selector switch with current transformer coil for three phase- 01 Nos (f)Indicator lamp with holder for RYB- 01 Set (g)DOL/Star-delta starter for 10 HP pumpset- 01 No 60 Supply,installation, commissioning in of LT panel (Outdoor type ) board not less than 60cmx60cmx65cm made out of 3.15 mm thick CRCA sheet vermin proof, including painting with sysnthetic enamelled paint, CPRI approved with colour code PVC sleeves for bus bar, front opened with locking arrangement, closed bus bar chameber, angle iron frame of size 50x50x6mm for skeleton and support embeded in concrete foundation comprising of the following :-(a) Copper bus bar 63 amps for phase & neutral-01 No (b)MCCB 4P 40 Amps, 16 KA - 01 Nos (In coming) (c) MCCB 4P 25 Amps, 16 KA - 02 No (O/G) (one spare) (e) Multifunctional meter digital type showing voltage, current, frequency, power factor , Kilo watt, Kilo watt hours with in bulit selector switch with current transformer coil for three phase- 01 Nos(f)Indicator lamp with holder for RYB- 01 Set (g)DOL starter for 05 HP pumpset- 01 No 61 Material and labour for cutting and excavation of road/pathways etc any type, size as reqiured for laying of pipe 80 mm, after laying of pipe returning filling including spreading, leveling watering and well ramming in layers upto 30cm in soft/loose soil and hardcore and top layer 100 mm (compacted) of cold bituminous mix, tamped and rolled properly using betuminous cold emulsion of industrial grade with penetration 40/50 mixed with aggregate of various sizes all as per manufacturers instructions to match the existing level of road/pathway complete all as specified and directed.Note: (i) Pipe shall be measured and paid separately. 62 S & F CI sluice valve class PN -1.6 ISI marked complete suitable for 80 mm bore of pipe with flanged ends and drilled stainless steel spindle CI gate with brass ring and cast iron cap, opearting wheel etc complete all as specified duly fixed at site with rubber flanges, nuts / bolts and washers including repair to disturbed surfaces and testing on completion complete all as specified and directed 63 Supply and fixing Gun-metal, globe or gate valves ISI marked 40 mm bore, with iron wheel head, screwed both ends foriron pipe orfor unions complete all as specified and directed 64 Supply and fixing Gun-metal, globe or gate valves ISI marked 20 mm bore, with iron wheel head, screwed both ends foriron pipe orfor unionscomplete all as specified and directed 65 M& L multistranded, copper wire 6 Sqmm single core FRLSH with heavy duty PVC conduit 25 mm from Starter Panel to motor terminal plate complete all as specified and directed 66 Fixing only hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air qualitycomplete all specified and directed by Engineer-in-Charge.(Note : AC will be issued under Sch B free for fixing) 67 Supply and fix Voltage stablizer for automatic operation, 5 KVA single phase naturally air cooled indoor type and disigned for input variation between 160V - 270V with outdoor voltage stabilized at 230v upto 15 amp and above capacity for compatibel devices and output stabilised voltage 230 volt upto 15 amp and above capacity complete all specified and directed. 68 S & Fsub-main wiring with two single core PVC copper conductor unsheathed wire multistranded 4.00 sqmm FRLSH including cutting chasing and grouting PVC pipe including Tee, Elbow, Bend etc and including 4.0 sqmm copper conductor single core with connnected by common earth all as specified including 20mm dia concealed PVC conduit, medium grade, ISI marked complete all as specified and directed.Note : Two lengths of 4.00 sqmm cable and one length of 4.00 sqmm earth cabl along wit PVC conduit will be measured as one running length. 69 S & F in replacement of sub-main wiring with two single core cables PVC insulated and un-sheathed 6 sqmm (Nominal Area) FRLSH stranded copper conductor drawn in and including steeldia 25mm “medium quality” conduit including 6.00 Sq mm (Nominal Area) copper cableas earthcontinuity conductor after chasing in wall and making good the disturbed surfaces and white wash or existing colour , necessary junction box and coversincluding necessary connections, PVCflexible pipes are used in pannel board while connecting the cable complete all as specified and directed. 70 S&F Industrial socket metal clad plug and socket with MCBs single pole 20 Amp complete all as specified and directed. 71 S & FMCB ‘B’ series type suitable for 240 volts,10 KA,AC supply 6 to 32 Amp single pole (SP) with over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified and directed. 72 S & FMCB ‘C’ series type suitable for 240 volts,10 KA,AC supply SPN 32 Amps , with over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified and directed. 73 S & F sheet metal enclosure for double door DBs made out of CRCA mild steel sheet surface with insulated material like polyester with epoxy powder coated surface mounted SPN 4 ways, 240 Volts, ISI marked 200 amps bus bar stove enameled dust and vermin proof suitable for incorporation MCBs and isolators etc complete all as specified and directed by Engineer - in -Charge.