| 1 | Excavation in trenches in soft or loose soil, not exceeding 1.5 metre deep and not exceeding 1.5 metre wide and getting out, complete all as specified and directed. |
| 2 | Returning, filling in trenches including spreading, leveling, watering and well ramming in layers not exc 25 cm thick in soft/loose soil, complete all as specified and as directed. |
| 3 | Removing surplus excavated soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point, complete all as specified and as directed. |
| 4 | M&L for brick protection with sub class \"B\" bricks (old size) laid dry, flat in trenches over cable with longest dimension perpendicular to the axis of the cable, complete all as specified and directed specified . |
| 5 | Material & labour for sand cushioning in trenches and well ramming in layers with 8 cm below and 15 cm above the cable with fine dry sand for cable protection, complete all as specified and directed.Note :- Only punned thickness of sand 18 cm shall be measured and paid. |
| 6 | Supply, laying, connecting, testing in repair of XLPE insulated, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor, cross sectional area 16 Sqmm 2 core, laid in trenches or passing through pipes etc including jointing materials such as cable glands, lugs etc and accessories for making connection at both ends, complete all as specified and directed. |
| 7 | All as per Srl item No 6.00 above but of size 25 sqmm 3.5/4 core. |
| 8 | All as per Srl item No 6.00 above but of size 35 sqmm 3.5 core. |
| 9 | All as per Srl item No 6.00 above but of size 50 sqmm 3.5 core. |
| 10 | All as per Srl item No 6.00 above but of size 70 sqmm 3.5 core. |
| 11 | All as per Srl item No 6.00 above but of size 95 sqmm 3.5 core.Note for Item No 7 to 11:-(i) Factory test of the cable shall be carried out in presence of the rep of accepting officer as detailed by Accepting Officer and contractor is required to submit purchase vouchers, e-way bill and test certificates while claiming payment of LT cables. The contractor will arrange the testing at factory premises and cost of the same is deemed to be included in the rates quoted. |
| 12 | All as per Srl item No 6.00 above but of size 120 sqmm 3.5 core. |
| 13 | All as per Srl item No 6.00 above but of size 185 sqmm 3.5 core. |
| 14 | All as per Srl item No 6.00 above but of size 240 sqmm 3.5 core. |
| 15 | S&F in replacement MCCB 63 Amp 4 pole, 415 V, adjustable type with breaking capacity 16 KA, complete all as specified and directed. |
| 16 | S&F in replacement MCCB 100 Amp 4 pole, 415 V, adjustable type with breaking capacity 25 KA, complete all as specified and directed. |
| 17 | S&F in replacement MCCB 125 Amp 4 pole, 415 V, adjustable type with breaking capacity 25 KA, complete all as specified and directed. |
| 18 | S&F in replacement MCCB 160 Amp 4 pole, 415 V, adjustable type with breaking capacity 25 KA, complete all as specified and directed. |
| 19 | S&F in replacement MCCB 200 Amp 4 pole, 415 V, adjustable type with breaking capacity 25 KA, complete all as specified and directed. |
| 20 | S&F in replacement MCCB 250 Amp 4 pole, 415 V, adjustable type with breaking capacity 25 KA, complete all as specified and directed. |
| 21 | S&F in replacement MCCB 315 / 320 Amp 4 pole, 415 V, adjustable type with breaking capacity 36 KA, complete all as specified and directed. |
| 22 | S&F in replacement MCCB 400 Amp 4 pole, 415 V, adjustable type with breaking capacity 36 KA, complete all as specified and directed. |
| 23 | S&F in replacement MCCB 500 Amp 4 pole, 415 V, adjustable type with breaking capacity 36 KA, complete all as specified and directed. |
| 24 | S&F in replacement MCCB 630 Amp 4 pole, 415 V, adjustable type with breaking capacity 36 KA, complete all as specified and directed. |
| 25 | S&F in repair cable junction boxes weather proof for outdoor installation (With knockouts for cable entry) of size 300 x 600 x 170 mm with cable entry range of 150-240 Sqmm including 4 Nos of Bus Bar, complete all as specified and directed. |
| 26 | S&F in repair aluminium Thimbles of sizes 6 Sqmm to 35 Sqmm conductor, complete all as specified and directed. |
| 27 | S&F in repair aluminium Thimbles of sizes 50 Sqmm to 150 Sqmm conductor, complete all as specified and directed. |
| 28 | S&F in repair aluminium Thimbles of sizes 185 Sqmm to 300 Sqmm conductor, complete all as specified and directed. |
| 29 | S&F in repair aluminium Thimbles of sizes 400 Sqmm to 630 Sqmm conductor, complete all as specified and directed. |
| 30 | Supply and laying in repair in trenches / fixing on wall steel water tubing, galvanised iron, 80 mm bore, light grade with all fittings, complete all as specified and directed. |
| 31 | Supply and laying in repair in trenches / fixing on wall steel water tubing, galvanised iron, 50 mm bore, light grade with all fittings, complete all as specified and directed. |
| 32 | M&L for boring under road/path/hard standing to pass the pipe lines upto 300mm dia bore with own arrangement of T&P, complete all as specified and directed. |
| 33 | M&L in repairsfor earthing with galvanised steel earth plate electrode of size 60cmX60cmX6.00mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate no less than 1.5m bellow normal ground level surrounded from all sides by 15cm thick and packed layer of charcol dust and common salt filling in alternatie layers and electrode connected by galvanised iron strip 32mmx6mm by means of bolts, nuts and washers connected to test termination point protected by 40mm bore GI pipe light grade and GI pipe light grade 20mm bore for watering and inlcuding funnel, wire mesh, RCC pit cover and PCC chamber with PCC 1:2:4 type B-1 includingnecessary excavation and earth work in soft/loose soil, returning filling, disposal of surplus soil to a distance not exceeding 50mtr all as specified and shown in Electrical Plate No 3 of SSR Part-I and testing, complete all as specified and directed.Note :(a)The unit rate shall include for GI water pipe, protection pipe wire mesh, funnel, excavation, RCC pit cover, PCC. Test point, GI strip 32x6mm from top of earth plate upto 7.5 mtr.(b)PCC pit shall be provided at least 1.5m away from the earth pit and extra cost of additional length of water pipes and fixing junction, elbow etc shall be deemed to be included in the unit rate.(c)RCC pit cover shall be precast of RCC 1:2:4 tyupe B-1, 80mm thick reinforced with XPM weighing not less than 4 Kg/sqm. |