| 1 | M & L for Comprehensive repairs & maintenance to HOT cranes (04 Nos ) having 1 Ton capacity to be carried out as under:-(a)Opening of the chain pulley block forlocation of faults and replacement of unserviceable parts as required at site including attending routine complaints of users to keep the chain pulley block operational through out the year (maximum break down period shallnot exceed more than 24 hrs from the time of receipt of complaint)(b) Checking the alignment of the ISMB for free movement of mechanically operated trolley.1 ton to 10 ton capacity consisting of minor repairs/ preventive maint of hoist motor, long travel motor, cross travel motor, gear box, control panel and connected accessories, including oiling, greasing, tightening of nut bolts, checking ofthruster brakes, brake shoes, brake setting, rail alignment, hoist spares, complete etc all as specified and directed by Engineer-in-charge. |
| 2 | (c) Repairs/ maintenance of mechanically operated trolley including replacement of worn out parts complete for smooth functioning of the crane. (d) Application of grease to components and chain as per the manufacturers instructions complete ete all as specified and directed(e) Quoted unit rate deemed to be include to attend the breakdown as and when required by usersif any spares changedwill be measured and paid under relevant item.(f) These items will be measured only when repair and maintenance carried out and serviceability documents duly signed Contractor, Rep of User & Rep of MES.(g)Breakdown complaints of crane to be attended within 48 hrs after intimation by MES Rep and further repairs to be carried out in reasonable time mutually decided by MES and contractor depending upon the nature of repairs required.(h) Spares shall be measured and paid separately. |
| 3 | M & L for Comprehensive repairs & maintenance and repairs to (02 Nos) of EOT crane having capacity 02 Tonwith the following repairs :-(a) Opening of gear box of LT/CT, crab for examination, replacement of worn out parts and tightening the loosened components, checking, locking systems and closing up including testing commissioning in whenever required in any number of times through out the year including load test after every repair as per the instruction by Engineer in Charge.The permissible break down period for repair shall not exceed 24 hr from the time of receipt of complaint.(b) Checking the alignment of the ISMB for free movement of mechanically operated trolley and replacement of the chain if required. |
| 4 | (c)Repair/replacement of worn out/burned unserviceable electrical items as required at site.(d) Application of grease to components and chain as per the manufacturers instructions complete ete all as specified and directed(e) Quoted unit rate deemed to be include to attend the breakdown as and when required by usersif any spares changedwill be measured and paid under relevant item.(f) These items will be measured only when repair and maintenance carried out and serviceability documents duly signed Contractor, Rep of User & Rep of MES.(g)Breakdown complaints of crane to be attended within 48 hrs after intimation by MES Rep and further repairs to be carried out in reasonable time mutually decided by MES and contractor depending upon the nature of repairs required.(h) Spares shall be measured and paid separately. |
| 5 | M & L for Comprehensive repairs & maintenance to HOT cranes (04 Nos ) having 2 Ton capacity to be carried out as under:-(a)Opening of the chain pulley block forlocation of faults and replacement of unserviceable parts as required at site including attending routine complaints of users to keep the chain pulley block operational through out the year (maximum break down period shallnot exceed more than 24 hrs from the time of receipt of complaint)(b) Checking the alignment of the ISMB for free movement of mechanically operated trolley.1 ton to 10 ton capacity consisting of minor repairs/ preventive maint of hoist motor, long travel motor, cross travel motor, gear box, control panel and connected accessories, including oiling, greasing, tightning of nut bolts, checking ofthruster brakes, brake shoes, brake setting, rail alignment, hoist spares, complete ete all as specified and directed by Engineer-in-charge. |
| 6 | (c) Repairs/ maintenance of mechanically operated trolley including replacement of worn out parts complete for smooth functioning of the crane. (d) Application of grease to components and chain as per the manufacturers instructions complete ete all as specified and directed(e) Quoted unit rate deemed to be include to attend the breakdown as and when required by usersif any spares changedwill be measured and paid under relevant item.(f) These items will be measured only when repair and maintenance carried out and serviceability documents duly signed Contractor, Rep of User & Rep of MES. (g)Breakdown complaints of crane to be attended within 48 hrs after intimation by MES Rep and further repairs to be carried out in reasonable time mutually decided by MES and contractor depending upon the nature of repairs required.(h) Spares shall be measured and paid separately. |
| 7 | M & L for Comprehensive repairs & maintenance to HOT cranes (01 Nos ) having 3 Ton capacity to be carried out as under:-(a)Opening of the chain pulley block forlocation of faults and replacement of unserviceable parts as required at site including attending routine complaints of users to keep the chain pulley block operational through out the year (maximum break down period shallnot exceed more than 24 hrs from the time of receipt of complaint)(b) Checking the alignment of the ISMB for free movement of mechanically operated trolley.1 ton to 10 ton capacity consisting of minor repairs/ preventive maint of hoist motor, long travel motor, cross travel motor, gear box, control panel and connected accessories, including oiling, greasing, tightning of nut bolts, checking ofthruster brakes, brake shoes, brake setting, rail alignment, hoist spares, complete ete all as specified and directed by Engineer-in-charge. |
| 8 | (c) Repairs/ maintenance of mechanically operated trolley including replacement of worn out parts complete for smooth functioning of the crane. (d) Application of grease to components and chain as per the manufacturers instructions complete ete all as specified and directed(e) Quoted unit rate deemed to be include to attend the breakdown as and when required by usersif any spares changedwill be measured and paid under relevant item.(f) These items will be measured only when repair and maintenance carried out and serviceability documents duly signed Contractor, Rep of User & Rep of MES. (g)Breakdown complaints of crane to be attended within 48 hrs after intimation by MES Rep and further repairs to be carried out in reasonable time mutually decided by MES and contractor depending upon the nature of repairs required.(h) Spares shall be measured and paid separately. |
| 9 | M & L for Comprehensive repairs & maintenance and repairs to(02 Nos) of HOT crane having capacity 5 Ton with the following repairs :-(a) Opening of gear box of LT/CT, crab for examination, replacement of worn out parts and tightening the loosened components, checking, locking systems and closing up including testing commissioning in whenever required in any number of times through out the year including load test after every repair as per the instruction by Engineer in Charge.The permissible break down period for repair shall not exceed 24 hr from the time of receipt of complaint.(b) Checking the alignment of the ISMB for free movement of mechanically operated trolley and replacement of the chain if required. |
| 10 | (c)Repair/replacement of worn out/burned unserviceable electrical items as required at site. (d) Application of grease to components and chain as per the manufacturers instructions complete ete all as specified and directed(e) Quoted unit rate deemed to be include to attend the breakdown as and when required by usersif any spares changedwill be measured and paid under relevant item.(f) These items will be measured only when repair and maintenance carried out and serviceability documents duly signed Contractor, Rep of User & Rep of MES. (g)Breakdown complaints of crane to be attended within 48 hrs after intimation by MES Rep and further repairs to be carried out in reasonable time mutually decided by MES and contractor depending upon the nature of repairs required.(h) Spares shall be measured and paid separately. |
| 11 | M & L for Comprehensive repairs & maintenance to Automatic boom barrier(02 Nos )to be carried out as under:-(a)Opening of the chain pulley block forlocation of faults and replacement of unserviceable parts as required at site including attending routine complaints of users to keep the chain pulley block operational through out the year (maximum break down period shallnot exceed more than 24 hrs from the time of receipt of complaint)(b) Checking the alignment of the ISMB for free movement of mechanically operated trolley.1 ton to 10 ton capacity consisting of minor repairs/ preventive maint of hoist motor, long travel motor, cross travel motor, gear box, control panel and connected accessories, including oiling, greasing, tightning of nut bolts, checking ofthruster brakes, brake shoes, brake setting, rail alignment, hoist spares, complete ete all as specified and directed by Engineer-in-charge. |
| 12 | (c) Repairs/ maintenance of mechanically operated trolley including replacement of worn out parts complete for smooth functioning of the crane.(d) Application of grease to components and chain as per the manufacturers instructions complete ete all as specified and directed(e) Quoted unit rate deemed to be include to attend the breakdown as and when required by usersif any spares changedwill be measured and paid under relevant item.(f) These items will be measured only when repair and maintenance carried out and serviceability documents duly signedContractor, Rep of User & Rep of MES. (g)Breakdown complaints of crane to be attended within 48 hrs after intimation by MES Rep and further repairs to be carried out in reasonable time mutually decided by MES and contractor depending upon the nature of repairs required.(h) Spares shall be measured and paid separately. |
| 13 | Supply only following items for EOT Crane of 02 ton capacity.Make-Cranex or equivalent as per sample at site. |
| 14 | (a) Supply only Bearing for LT/CT hoist for EOT 2 ton capacity crane Make- Cranex or equivalent as per sample etc of any capacity EOT crane. |
| 15 | (b) Supply only Actuator for brake for EOT2 ton capacity crane |
| 16 | (c )Supply only Thruster brake assembly for EOT 2 ton capacity crane |
| 17 | (d) Supply only Brake shoe with lining for EOT2 ton capacity crane |
| 18 | (e) Supply only Magnetic Brake coil for EOT2 ton capacity crane |
| 19 | (f) \"O\" rings |
| 20 | (g )Gear as per sample |
| 21 | (h) Pinion |
| 22 | (j) Supply only magnetic clutch coil (Big Size) suitable for EOT crane of capacity 2 Tonne. |
| 23 | (k) Supply only magnetic brake coil (Small Size) suitable for EOT crane of capacity 2 Tonne. |
| 24 | (l) Supply only break shoes suitable for movements of 2 Tonne capacity EOT crane. |
| 25 | (m) Supply only brass wheel / pulley brush for trolley mounted power sources for EOT crane of 2 Tonne capacity. |
| 26 | Supply only heavy duty limit switch with 2NO+2NC auxiliary contacts complete all as specified and directed. |
| 27 | Supply only power contactor, 3 pole,AC-3 current rating 18 Amps and with auxiliary contacts 1NO+1NC, with coil voltage 110/220/415 volts, conforming to IS / IEC 60947-4-1 complete all as specified and directed by Engr-in-charge. Make:- L&T / EE/ Havells. |
| 28 | Supply only power contactor, 3 pole, AC-3 current rating 12 Amps and with auxiliary contacts 1NO+1NC, with coil voltage 110/220/415 volts, conforming to IS / IEC 60947-4-1 complete all as specified and directed by Engr-in-charge. Make:- L&T / EE/ Havells. |
| 29 | Supply only thermal overload relay capacity up to 3 Amps to 5 Amps for EOT crane of capacity 2 Tonne. |
| 30 | Supply only thermal overload relay capacity up to 2 Amps to 3.5 Amps for EOT crane of capacity 2 Tonne. |
| 31 | Supply only control transformer 500 VA, 110 volt for EOT crane of capacity 2 Tonne. |
| 32 | Supply only push button with elements suitable for EOT crane of capacity 2 Tonne. |
| 33 | Supply only 4 core, 2.5 sqmm PVC insulated and PVC round sheathed, copper conductor (flexible) multistranded industrial cable 1100 Volts complete all as specified and directed. |
| 34 | Supply only porcelain bush insulator 3 inch for EOT crane of capacity 2 Tonne. |
| 35 | S & F Aluminium conductor, steel reinforced to be fixedalong with crane gantry at minimum height of 6 mtr from ground level complete all as specified and directed by Engr-In-Charge, |
| 36 | Supply only diode bridge 16 Amps, 1200 Volt for EOT crane of capacity 2 Tonne. |
| 37 | Supply only HRC fuse complete 4/6 Amps, 230 volts complete all as specified.. |
| 38 | Supply only control copper cable multicore of 12 core suitable for pendent of EOT Crane 2 Tonne capacity. |
| 39 | M&L for rewinding of 3.5 HP motor with new super enameled copper wire of existing size/gauge after cutting of burned winding including all insulating materials such as insulation varnish, PVC copper cable lead, glass fiber sleeves, cotton tape, insulation paper and heating in heat chamber at appropriate temperature including transportation to workshop (both way) all as specified and directed. |
| 40 | M&L for rewinding of 1.6/1.2 HP motor with new super enameled copper wire of existing size/gauge after cutting of burned winding including all insulating materials such as insulation varnish, PVC copper cable lead, glass fiber sleeves, cotton tape, insulation paper and heating in heat chamber at appropriate temperature including transportation to workshop (both way) all as specified and directed. |
| 41 | S&F in replacement of ball/roller bearing for motor of capacity 3.5 HP complete all as specified. |
| 42 | S&F in replacement of ball/roller bearing for motor of capacity 1.6/1.2 HP complete all as specified. |
| 43 | S&F in replacement of voltmeter digital type 0-500 volts AC, flush mounting type complete all as specified. Make: L&T/HPL/AE. |
| 44 | S&F in replacement ofammeter digital type, flush mounting type complete with suitable CTs of range as required on site complete all as specified. Make: L&T/HPL/AE. |
| 45 | S&F in replacement of LED indicator as per colour scheme (Red/Yellow/Blue/Green) suitable for DG panel complete all as specified. Make: As per sample. |
| 46 | S&F in replacement of push button switch including making all electrical connection complete all as specified. Make: As per sample. |
| 47 | Note : Fixing charges for spares shall be deemed to be included in Ser item No 01 to 06. |
| 48 | Dismantling / Removing existing control & power wiring of long travel/cross travel/main hoist/auxiliary hoist control Panel wiring of EOT Crane of Capacity 2 tonand rewiring with PVC insulated copper wire required size for control & for power wiring for proper sequential working of contactors with delay timer, over load relay,MCCB, MCB etc of slip ring motor of diff capacity by making proper connections to contactors, relays, fuses, MCCB, MCB incl testing commissioning complete as directed .Note:- (i)Material such as wires of different sizes for interconnections and hardware, PVC channels, lugs, terminals din rails connectors, welding work for panel wiring on Eot crane will be include in above rates.(ii)The quoted rate include the cost of painting of existing control panel with two coats of existing coloured paints and any addition/alteration in the existing control panel complete all as directed by Engr-in-charge. |
| 49 | (iii) Required components such as MCCB\"s, MCB\"s, HRC fuse, power contactors, relays, timers, Single phase preventor , push buttons will measured and paid separately.(iv) The work is to be done in such a manner that it should not hamper the working schedule of the user.(v) Contractor should visit the site and work out details of required components such as MCCB\"s, MCB\"s, HRC fuse, power contactors, relays, timers, Single phase preventor , push buttons etc before quoting the tender.(vi) Control wiring should be done in such a manner to meet the logic and operation. Suitable skilled rep shall be deputed to do the same. Necessary test reports to be submitted after completion of work. (vii) For payment purpose one function of power and control wiring measured in Each job. |
| 50 | Taking down of old unsv switch disconnector fuse units and supply and fixing of new switch disconnector fuse units of 63 amps TPN suitable for DIN fuse link complete all as specified and directed by Engineer-in-charge. |
| 51 | Taking down of old unsv switch disconnector fuse units and supply and fixing of new switch disconnector fuse units of 100 amps suitable for DIN fuse link complete all as specified and directed by Engineer-in-charge. |
| 52 | Supply only of VFDs voltage class 400 Volt Drive 0.75 kW (HD) / 1.5 kW (ND) completesuitable for existing one all as specified and directed by Engineer-in-charge |
| 53 | Supply only of VFDs voltage class 400 Volt Drive 1.5 kW (HD) / 2.2 kW (ND) complete suitable for existing one all as specified and directed by Engineer-in-charge |
| 54 | Supply only of new limit switches suitable for EOT crane of any capacity 02 ton as per existing make complete |
| 55 | Supply only of LED indication lamp Red, Blue, Yellow of size 22.5mm complete all as specified and directed by Engineer-in-charge |
| 56 | Taking down of old Unsv trolley cable carrier and supply and fix PVC trolley cable carrier suitable for any type of crane complete all as specified and directed by Engineer-in-charge |
| 57 | Supply only Gear oil suitable for EOT/HOT crane complete all as specified and directed by Engineer-in-charge |
| 58 | M & L for repairs to gear box including replacement of worn out driving/ driven gears, bearings, gear keys, gasket oil seals of capacity01 ton to 5 ton EOT /HOT crane complete all as specified and directed by Engineer-in-charge |
| 59 | Supply , laying, commissioning and testingmulti core PVC insulated, tinned cable of size 1.00 Sqmm 19 core,1100 volt, stranded, copper conductor, flexible,unarmoured cablewith suitable size of cable clamps and lugs for crane pendant including dismantling carefully and removing unserviceable cable complete all as specified and as directed. |
| 60 | Supply , laying, commissioning and testingmulti core PVC insulated cable of size 4.0 Sqmm 4 core,1100 volt, stranded, copper conductor, flexible, unarmed cablewith suitable size of cable clamps and lugs including dismantling carefully and removing unserviceable cable complete all as specified and as directed. |
| 61 | Supply , laying, commissioning and testingmulti core PVC insulated cable of size 2.5 Sqmm 4 core,1100 volt, stranded, copper conductor, flexible, unarmed cablewith suitable size of cable clamps and lugs including dismantling carefully and removing unserviceable cable complete all as specified and as directed. |
| 62 | Supply only Over load relay for EOT crane induction motor of range 4.5 - 7.5 Amps complete all as specified and as directed.Make :- BCH/ Siemens/L &T as approved by GE |
| 63 | Supply only Over load relay for EOT crane induction motorof range 24 - 40 Amps complete all as specified and as directed.Make :- BCH/ Siemens/L &T as approved by GE |
| 64 | Supply only Power contactor 40 Amps, 3pole AC 415 V with 1 NO& 1 NC contacts and coil voltage 110 volts AC. complete all as specified and as directed. Make :- BCH/Siemens/L &T as approved by GE |
| 65 | Supply only Power contactor 32 Amps, 3pole AC 415 V with 1 NO& 1 NC contacts and coil voltage 110 volts AC. complete all as specified and as directed. Make :- BCH/Siemens/L &T as approved by GE |
| 66 | Note : Fixing charges for spares shall be deemed to be included in Ser item No 01 to 06. |
| 67 | Supply and Fixing Single phase preventor relay with auto and manual reset complete all as specified and as directed. Make :- BCH/Siemens/L &T as approved by GE |
| 68 | Supply and Fixing MCB 40 Amps 10KA, TP\"C\" curves in the control panels including dismantling of old unsv onecomplete all as specified and as directed. Make :- L & T/ ABB/ Legrand as approved by GE |
| 69 | Supply and Fixing MCB 10 Amps 10KA, DP \"C\" curves in the control panels including dismantling of old unsv onecomplete all as specified and as directed.Make :- L & T/ ABB/ Legrand as approved by GE |
| 70 | Supply and fixing MCCB 63 Amps, TP,415 volt ,Ics=100%Icu,18 KA with thermal magnetic release in the control panels including supply & fixing suitable size spreader links, phase barrier with suitable nuts,bolts,lugs for termination and any misc items incl addition/ alteration for complete fixing in the panel is deemed to be included etc and dismantling of old unsv one complete all as specified and as directed. Make :- L & T/ABB/Legrand as approved by GE |
| 71 | S & F in replacement instrument transformer for crane of capacity 415/110 volts, 800 VA including complete control wiring with suitable size of copper wire all as specified and directed. |
| 72 | Taking down of old unsv wire rope from EOT crane of any size and capacity and Supply and fixing in repair galvanised steel wire rope 8/10mm dia of6x36 construction of best plough steel having minimum tensile strength of 180kg/sqmm complete all as specified and directed |
| 73 | Disconnecting and taking down from EOT crane unserviceable resistors box of any type, any capacity and any height and Supply and fixing stainless steelresistor box type 4 steps 10 min. rating suitable for 01 HP to 10 HP Slip ring Motor and Rotor volt 260 complete all as specified and as directed.Make: Speedo Control or Equivalent as approved by the GE |
| 74 | Supply and fixing in replacement of Push button Pendants 12 way with emergency switch for cranes all as per sample and details in complete specified and directed. |
| 75 | Supply and fixing in replacement of Push button Pendants 18 way with emergency switch for cranes all as per sample and details in complete specified and directed. |
| 76 | Material and Labour for calibration andload testing of EOT/ HOT cranes by providing artificial load (external) of capacity 1.25 times of SWL complete all as specified and directed. Note: Load testing as per SWL of crane capacity. Load will be arranged by the contractor for load testing and shifting of the loads to testing at site and back to the place by engaging suitable crane/transport with man power shall be the contractors responsibility and the quoted rate shall be deemed to include for the same.The details of cranes are as follows:- |
| 77 | (a) EOT Crane 2 ton capacity |
| 78 | (b) HOT Crane 1 ton capacity |
| 79 | (c) HOT Crane 2 ton capacity |
| 80 | (d) HOT Crane 3 ton capacity |
| 81 | (e)HOT Crane 5 ton capacity |
| 82 | M & L forCleaning oftotal structure of EOT crane2 Ton capacity including , remove all grease, oil . Dust & dirt complete form crane platform ,all side walls, supporting beams, brackets ,pipe supports , guards complete including controlpanels, cabins etc complete and Material & Laying forpainting the totalstructure of crane with existing colourwith two coats of synthetic enamel paint with spray gun and writing of SM No. Manufacture\"s name, CA number and capacity of crane with bright black/red paint complete all as directed by Engr-in-charge.Note:- (i)The quality of paint should be as per existing make :- Nerolac/Asian paints(ii) Necessary safety measures to be taken by the contractor while cleaning and painting of the crane .(iii) Any damage/loss to the govt property while doing the job of painting will be borne by the contractor.(iv) The cost of T&P such as ropes, ladders, brushs etc required for the jobis included in the quoted rates.(v) The work is to be carried out at the height of above 25 feets. |
| 83 | Replacement of power contactor size-I, \"type ML- 2\" 40 Amps rated 415 / 110 / 24 volts complete all as specified anddirected by Engr -in-Charge.Make : ABB/BCH/ L&T /Siemens |
| 84 | Replacement of cable carrier for 2.0 ton EOT crane complete all as specified and directed Engr -in-Charge.Make : Albrasco/ Meagtech |
| 85 | Replacement of micro movement clutch assembly for EOT Crane complete all as specified and directed by Engr -in-Charge. Make : Megatech/Pathe/Emco |
| 86 | Replacement of PVC insulated FRLS copper cable size 0.5 to 0.75Sqmm ,16 Core to 19 core for moveable pendant system with accessories complete all as specified and directed by Engr-in-Charge. Make : Paragon/Alcone |
| 87 | Replacement ofDC clutch with accessories complete all as specified and directed by Engr-in-Charge.Make : Pethe/Meagtech |
| 88 | Replacement of electromagneticbrake coil for hoist motion of 2 ton EOT cranes complete all as specified and directed by Engr-in-Charge. |
| 89 | Replacement of electromagneticbrakes thrustercomplete set including dismantling old unserviceable brake including removal from site complete all as specified and directed by Engr-in-Charge.Make : Pethe /meagtech |
| 90 | Electromagnetic disc brake, AC 415 volts, complete all as specified and directed by Engr-in-Charge.Make : Pethe/Meagtech |
| 91 | Replacement of step down transformer 415/220/110 V, A.C 500 VA complete all as specifiedand directed by Engr-in-Charge. Make: Universal/Meagtech |
| 92 | Flushing and topping of gear oil SAF-90 (for LT, CT, hoist and creep gear box) complete all as specified and directed by Engr-in-Charge.Make : Servo/Castrol |
| 93 | Replacement of worn out brakes with flame proof AC brakes, suitable for 2 Ton EOT crane complete all as specified and directed by Engr-in-Charge.Make: Megatech/Pathe/Emco |
| 94 | Provision of buzzer (industrial hooter type) to indicate any type of problem to EOT Crane complete including necessary fixing and electrical connection suitable for 2 Ton EOT crane complete all as specified and directed by Engr-in-Charge.Note : Buzzer should emit sound to be heard up to minimum 25 mtr distance. |
| 95 | Replacement of unserviceable contactor ML-3, 50 Amps capacity3 phase 50 C/S 415 Vols. Make : Schneider, ABB,GE, L& T |
| 96 | Replacement of unserviceable contactor ML-2, 32 Amps capacity3 phase 50 C/S 415 Vols. Make : Schneider, ABB,GE, L& T |
| 97 | Replacement of unserviceable over load relay 6-9Amp capacity 3 phase 50 c/s 415 volt. |
| 98 | Replacement of unserviceable over load relay 9-16Amp Capacity 3 phase 50 c/s 415 volt. |
| 99 | Replacement of unserviceable AC drive, slow/high speed suitable for 2 Ton EOT crane. Make: Delta or equivalent |
| 100 | Opening/dismantling taking out old unserviceable burnt out winding from transformer 440 Volt capacity including re- winding with copper insulator wire water proof of existing size including reassembling and testing complete all as directed and specified by Engr-in-Charge. |
| 101 | M & L forCleaning oftotal structure of HOT crane of01 to 05Ton capacity including , remove all grease, oil . Dust & dirt complete form crane platform ,all side walls, supporting beams, brackets ,pipe supports , guards complete including controlpanels, cabins etc complete and Material & Laying forpainting the totalstructure of crane with existing colourwith two coats of synthetic enamel paint with spray gun and writing of SM No. Manufacture\"s name, CA number and capacity of crane with bright black/red paint complete all as directed by Engr-in-charge.Note:- (i)The quality of paint should be as per existing make :- Nerolac/Asian paints(ii) Necessary safety measures to be taken by the contractor while cleaning and painting of the crane .(iii) Any damage/loss to the govt property while doing the job of painting will be borne by the contractor.(iv) The cost of T&P such as ropes, ladders, brushes etc required for the jobis included in the quoted rates.(v) The work is to be carried out at the height of above 25 feets. |
| 102 | M&L for replacement of old unsv chain pulley block of EOT Crane of 2 ton capacity of existing make complete all as specified and directed by Engineer - in - Charge. |
| 103 | Note :- An amount of Rs. 20,345.00on account of credit schedule for Sch \"A\" Part-II Shall be deducted from the total amount of BOQ to arrive at the contract sum. |