| 1 | Disconnecting electrical wire of ceiling fan of any type/size and make, taking down from its position, opening, cleaning and greasing after removing the blade to make noise free smooth operation including replacement of wornout capacitor , capacitor holder wire connector with pvc twin twisted wire assembling and placing its position using new clamp set (clamp, rubber bush and nut and bolt, locking pin make sure for firm grip) including testing complete all as directed by Engineer-in-Charge. (NOTE : 1. Spare parts like capacitor, clamp set, PVC twin twisted wire to be replaced shall be measured and paidseparately as supply only item. 2. if fan need repair then submit to defective fan to MES store and take a repaird fan and placed the fan on same position. |
| 2 | Disconnecting electrical connection of wall mounted fan of any type/size and make, taking down from its position, for oilling and greasing the fan motor, oscillation motor, shaft and bush for speed and oscillation control after removing the blade grill ring, blade front and rear grill, blade, check nut to make noise free smooth operation including replacement of wornout capacitor, wire connector, capacitor holder with pvc two core wire, plug top assembling and placing at its own position (make sure for farm grip) including testing complete all as directed by Engineer-in-Charge. (NOTE : 1. Spare parts like capacitor, clamp set, PVC two wire, plug top to be replaced shall be measured and paidseparately as supply only item. 2. if fan need repair then submit the defective fan to MES store and take a repaird fan and placed the fan on same position. |
| 3 | Disconnecting electrical connection of padestal fan or stand fan of any type/size and make, opening it for oilling and greasing the fan motor, oscillation motor, shaft and bush for speed and oscillation control after removing the blade grill ring, blade front and rear grill, blade, check nut to make noise free smooth operation including replacement of wornout capacitor, capacitor holder wire connector with pvc two core wire, plug top etc assembling including testing complete all as directed by Engineer-in-Charge. (NOTE : 1. Spare parts like capacitor, clamp set, PVC two wire, plug top to be replaced shall be measured and paidseparately as supply only item. 2. if fan need repair then submit the defective fan to MES store and take a repaird fan and placed the fan on same position. |
| 4 | Disconnecting electrical connection of Exhaust fan of any type/size and make, taking down from its position, for oiling and greasing the exhaust fan motor,shaft and bush after removing the blade to make noise free smooth operation including replacement of wornout capacitor, capacitor holder wire connector with pvc twin wireassembling and placing at its own position (make sure for farm grip) including testing complete all as directed by Engineer-in-Charge. (NOTE : 1. Spare parts like capacitor, PVC two wire, to be replaced shall be measured and paidseparately as supply only item. 2. if fan need repair then submit the defective fan to MES store and take a repaird fan and placed the fan on same position |
| 5 | M&L for rewinding of ceiling fan of any sweep after dismenting complete motor assembly, bearings, bushings, shaft, roter, removal of burnt copper wire, cleaning of core, inserting proper insulating paper in slots, winding with and as per existing size / turn of super enamelled copper wire, heating, vernishing, replacement of unserviceable bearings, bushings, shafts, roter assemblewith capacitor, connecting wire, down rod, blades and testing complete. Note: 1. Cost of transportation will be inclusive of quoted rate. 2. Spares require for repair such as bearing, bushing, shafts, roter capacitor, connecting wire to ceiling roseshall be measured and paid separately as supply only. |
| 6 | M&L for rewinding of wall mounted fan / Stand fan of any sweep after dismenting complete motor assembly, bearings, bushings, roter shaft, removal of burnt copper wire, cleaning of core, inserting proper insulating paper in slots, winding with and as per existing size / turn of super enamelled copper wire, heating, vernishing, replacement of unserviceable bearings, bushings, shafts, roter assemble with capacitor, connecting wire, blades and testing complete. Note: 1. Cost of transportation will be inclusive of quoted rate. 2. Spares require for repair such as bearing, bushing, shafts, roter capacitor, connecting wire, plug top shall be measured and paid separately as supply only. |
| 7 | M&L for rewinding of Exhaust Fan of 250 mm to 380 mm sweep after dismenting complete motor assembly, bearings, bushings, roter shaft, removal of burnt copper wire, cleaning of core, inserting proper insulating paper in slots, winding with and as per existing size / turn of super enamelled copper wire, heating, vernishing, replacement of unserviceable bearings, bushings, shafts, roter assemble with capacitor, connecting wire, blades and testing complete. Note: 1. Cost of transportation will be inclusive of quoted rate. 2. Spares require for repair such as bearing, bushing, shafts, roter capacitor, connecting wire to ceiling roseshall be measured and paid separately as supply only. |
| 8 | M&L for rewinding of Exhaust Fan of 450 mm sweep after dismenting complete motor assembly, bearings, bushings, roter shaft, removal of burnt copper wire, cleaning of core, inserting proper insulating paper in slots, winding with and as per existing size / turn of super enamelled copper wire, heating, vernishing, replacement of unserviceable bearings, bushings, shafts, roter assemble with capacitor, connecting wire, blades and testing complete. Note: 1. Cost of transportation will be inclusive of quoted rate. 2. Spares require for repair such as bearing, bushing, shafts, roter capacitor, connecting wire to ceiling roseshall be measured and paid separately as supply only. |
| 9 | Supply only ball bearing for ceiling fan |
| 10 | Supply only roter ring for ceiling fan as per existing pattern |
| 11 | Supply onlyBush and shaft for ceiling fan as per existing pattern |
| 12 | Supply onlyclamp set for ceiling fan as per existing pattern |
| 13 | Supply only Bush ,Shaft and roter for wall fan, stand fan, Exhaust fan as per existing pattern |
| 14 | Supply only wall mountes fan PVC blade as per existing pattern |
| 15 | Supply only helical gear box for wall fan and stand fan as per existing pattern |
| 16 | Supply only capacitor AC for 230 volts 50 Hz of capacity 1.7 / 2.5 Mfd |
| 17 | Supply only of PVC insulated, sheathed twin twisted stranded copper conductor flexible cable of size 1.5 Sqmm all as specified and directed. |
| 18 | Supply and fix in repair of 2 core copper conductor of sizes 1.5 sq.mm with taking down of old unserviceable incoming cables of Wall fan and stand fan. |
| 19 | Taking down carefully copper/aluminium point wiring including sunken MS boxes (light, fans, socket or power) complete, (fittings such as switches, ceiling roses,call bell, pendants, regulators, socket etc by unscrewing from board carefully and making good disturbed surfaces of walls, floors etc complete all as specified & directed . |
| 20 | Material and labour for point wiring for one light / Fan / Ex Fan pointcontrolled by 1 one way switch with 1.5 Sqmm PVC insulated unsheathed single core multi-stranded copper conductor (FRLS) cable 1100 Volts grade in and including PVC capping and casing (double lock, ISI Marked) of suitable size with all necessary fittings along with 1.5 sqmm continuous PVC insulated unsheathed stranded copper conductor (FRLS) cable for earth continuity wire, connected to earth dolly and to be terminated in an MS rectangular Box with bakelite sheet cover / PVC rectangular switch board of suitable size for mounting switches, sockets, fan regulators etc or MS modular boxes / PVC modular box suitable for mounting modular switches, sockets etc including testing on completion complete all as specified and directed. |
| 21 | All as per Item No 20 here-in-before but for one switch socket outlet, 5 Amp on independent board all as specified and as directed. |
| 22 | S&F Switch piano, flush type, single pole, one way 5 Amps, 240V complete all as directed by Engineer-in-Charge. |
| 23 | Fixing in repair Switch piano,flush type single pole, one way, 5 Amps (Serviceable switch obtained from item No-1 shall be reused). |
| 24 | Supply and fix modular switch 1 way 6 Amps 1 Module complete all as specified and directed |
| 25 | Supply and fix in repair LED tube light fittings 1 x 09/10 Watt two feets long with polycarbonate housing & intigrated electronic driver and necessary electric connection complete all as specified and as directed |
| 26 | Supply and fix in repair LED tube light fittings 1 x 18/20 Watt four feets long with polycarbonate housing & intigrated electronic driver and necessary electric connection complete all as specified and as directed |
| 27 | Supply and fix of Decorative, wall mounting, brushed nickel finish fixture with Opal Glass diffuser suitable with 9 W LED lamp B22 base complete all as specified and as directedMake: Havells cat par no LHFOAJE1TZ1I060/ aquar / Phillips |
| 28 | S&F Ceiling rose 2 or 3 terminalPVC / poly carbonate isolated body complete all as specified and as directed |
| 29 | Fixing only serviceable Ceiling rose, 2 pole / 3 pole, PVC / polycarbonate, insulated bodycomplete all as specified and directed |
| 30 | Supply and fixing in repair switch socket combination5 Pin 6 Amp with PVC Box complete all as specified and directed. |
| 31 | Supply and fixing in repair of Step type electronic Fanregulator step type complete all as specified and directed |
| 32 | Supply and fixing in repair of Modular Fanregulator,120 watts complete all as specified and directed. |
| 33 | Supply and fix in repair of white modular cover plate with frame 3 Module complete all as specified and directed |
| 34 | Supply and fix in repair of white modular cover plate with frame 6 Module complete all as specified and directed |
| 35 | Supply and fix in repair of white modular cover plate with frame 8 Module complete all as specified and directed. |
| 36 | Supply & fix modular socket2 in 1,5 pin 6 Amps, 2 modules complete all as specified and directed |
| 37 | Supply and Fix in repair plug top 3 pin 6 amp for wall fan and stand fan complete all as specified and directed |
| 38 | Supply and fix in repair louvers and shutterin circular shape for Exhaust fan of any sweep size and taking down unserviceable complete all as specified and directed |
| 39 | Earthing complete with galvanised steel earth plate electrode 60×60cm× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less\"than 1.5 metres below normal ground level, connected to 4 mm dia galvanised iron as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion |
| 40 | Supply and fix of Earth continuity conductor or main earthing lead 4mm dia galvanised iron or steel wire complete all as specified and directed. |