| 1 | Material and labour for preparation of old painted surfaces of steel tubular pole any type incl cross/arms and painting with two coat of aluminium paint over a coat of red oxide primer after cleaning/srappingof existing rusted surface incl cross arms, clamps etc for 8.5/9.00 meter long single pole complete including marking of pole No with white paint on black colour background with all arrangement for ladder etc all as specified and directed. |
| 2 | Material and labour for painting of bottom portion of the pole upto 0.75m from top of the copping with one coat of synthetic enamel paint of af colour over a coat of red oxide primer after cleaning of existing surface for steel tubular LT pole of any size complete all as specified and directed. |
| 3 | Material and labour fluoresent Retro-reflective Tape of size not less than 50 mm width high grade quality of yellow/Red colour fixed on pole after cleaning of existing surface complete all as specified and directed. (Note : 2 run of tape (Yellow & Red) will be count one run) . Make : 3M or equivalent approved make. |
| 4 | Taking downof old unserviceable/serviceablesteel tubular pole or concrete pole of9.0 Mtr long with necessarydemolition of concrete foundation, stay wire if anyfrom existing position and kept in safe place for reusing of serviceable pole including excavation & earth work as reqd and removing complete all as specified and directed. |
| 5 | Material and labour for fixing, transporting, errectingof old steel tubular pole obtained from item no. 4 at new location as directedall as specified and directed. Note : (i) Earth wks and PCC works shall be paid separately under respective items of this schedule. (ii) Cost for taking down and refixing of Old MS works/light fittings on old pole to new poles deemed to be inclusive in the quoted rate. |
| 6 | Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth and getting out in any type of soil complete all as specified and directed. |
| 7 | Excavation in trenches not exceeding 1.5 mtr wide and exceeding 1.5 mtr in depth and getting out in any type of soil complete all as specified and directed. |
| 8 | Removing excavated material to a distance not exc 50 m and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed. |
| 9 | Material and labour for PCC 1:4:8 type D2,40mm graded aggregate for foundation of poles etc.. All as specified and as directed. |
| 10 | Material and labour for PCC 1:3:6 type C1,20mm graded aggregate for coping of poles etc. All as specified and as directed. |
| 11 | Supply and fix of stay assembly for LT poles complete, comprising of gavanised steel stranded stay wire 7/3.15mm, galvanised steel stay bow 400 x 14, galvanized steel rod 2150 mm long 20 mm dia with nut bolts and washers, steel plate 230 x 230 x 6mm thick, 2 nos thimble,including dismantling old one complete all as specified and as directed. ( Note : PCC and earth work inclusive in quoted rate ) |
| 12 | Earthing complete with galvanised steel earth plate electrode 60×60cm×6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanized earth wire 4 mm by means of bolt, nut, check nut and washer of galvanized iron or steel earthing lead to be protected by galvanized iron pipe of 40 mm bore light grade and other end connected to earthing test point or main controlling switch as directed including providing funnel with 20 mm bore galvanized iron pipe medium grade for watering wire mess all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion and taing down old unservicable one all as directed. |
| 13 | Material and labour for preparation of existing surface of Feeder pillar box /Junction Box/LT Panel and apply two coat of synthetic enamel paint by spray gun complete all as specified and directed |
| 14 | Supply and fix in repair cable junction boxes weather proof for outdoor installation for loop connection of street light cable of size 155x210x92 mm with 3 pole terminals fixed on pole steel/PCC with suitable two flat iron clamp 25x4mm with nuts and bolts (duly painted with two coats of aluminium paint over a coat of red oxide primer) including provision for cable entry and exit and making holes on steel pole where required or directed, including dismantling old one complete all as specified and as directed.Make: Sintex/ Hensel/Rittel |
| 15 | Repair of old servicable panel having broken doors, rusted sheets, providing latch lock the panel in front and back and fresh sheet on rusted portion and fix with welding torch and wrap insulation tapes on cable, tighten the new nut and bolt to bus bar complete all as specified and directed |
| 16 | Material and labour for street light bracket made out of GI pipe light grade 40 mm dia 1.2mtr length bent to shape and reduced to required size at top upto 1.5m length by cutting, welding and well finishing including MS clamp of flat iron of size 40 x 6 mm suitable length 2 Nos complete with drilling, hole, fixing with nuts bolts and washers including painted with two coats aluminium paint over a coat of red oxide primer and dismantling old one. Make of GI pipe: JINDAL/PRAKASH/SURIYA/ZENITH |
| 17 | Supply and fixing in repair MCCB, adjustable thermal magnetic release type, 4 poles, 415 Volts, Ics = 100% Icu, 36 KA breaking capacity, rating 320 or 400 Amps including all fixing accessories with both ends spreader links after taking down old one.(Make :-Legrand/L&T/Havells/Indoasian) |
| 18 | Supply and fixing in repair MCCB, adjustable thermal magnetic release type, 4 poles, 415 Volts, Ics = 100% Icu, 36 KA breaking capacity, rating 200 Amps including all fixing accessories with both ends spreader links after taking down old one. (Make :-Legrand/L&T/Havells/Indoasian) |
| 19 | Supply and fixing in repair MCCB, adjustable thermal magnetic release type, 4 poles, 415 Volts, Ics = 100% Icu, 36 KA breaking capacity, rating 160 Amps including all fixing accessories with both ends spreader linksafter taking down old one. (Make :-Legrand/L&T/Havells/Indoasian) |
| 20 | Supply and fixing in repair MCCB, adjustable thermal magnetic release type, 4 poles, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity, rating 125 Amps including all fixing accessories with both ends spreader links after taking down old one. (Make :-Legrand/L&T/Havells/Indoasian) |
| 21 | Supply and fixing in repair MCCB, adjustable thermal magnetic release type, 4 poles, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity, rating 100 Amps including all fixing accessories with both ends spreader links after taking down old one. (Make :-Legrand/L&T/Havells/Indoasian) |
| 22 | Supply and fixing in repair MCCB, adjustable thermal magnetic release type, 4 poles, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity, rating 25 to 63 Amps including all fixing accessories with both ends spreader links after taking down old one. (Make :-Legrand/L&T/Havells/Indoasian) |
| 23 | Supply and fixing in repair of onload changeover open enclosure of 200 Amps in panel mounted 440 Volt 4 pole with disconnecting existing cable and reconnecting the cable afer taking down old one all as directed and specified Make : L&T/C&S/Havells |
| 24 | Supply and fixing in repair of onload changeover ss enclosure of 400 Amps in wall mounted 440 Volt 4 pole with disconnecting existing cable and reconnecting the cable afer taking down old one all as directed and specified Make : L&T/C&S/Havells |
| 25 | Supply and fixing in repair 1100 volts grade heavy duty cable PVC insulated aluminium conductor, one twin core cable flat or circular size 2.5 Sqmm complete all as per specified and directed |
| 26 | Supply and fixing in repair on surface XLPE LT copper armoured electric power cable (heavy duty), 1100V, Size 10 Sqmm 2 core complete all as per specified and directed. Make: KEI/Havells/Polycab |
| 27 | Supply and fix in repair aluminium bus bar of size 40 to 80 mm X 4 to 10 mm thick insulated with sleeves and provision of making holes as required with nuts, bolts & washers suitable for busbar panel including taking down old one complete all as directed. |
| 28 | Supply and fix in repair indicator lamp Red Yellow and Blue after taking down old one complete all specified and directed. |