Tender For Renovation Work Of Block Statistical Office Jalore - Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sum on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter. All kinds of soils. 3 Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to Plinth level.1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size). 4 Brick work with clay flyash F.P.S. brick of class designation 75 in superstructureaboveplinth level upto floor five level in : Cement mortar 1 : 6 (1 cement : 6 coarse sand) 5 Plaster onnew surfaceonwallsincement sandmortar1:6includingrackingofjoint etc. complete fine finish : 20mm thick. 6 Gradingroofforwaterproofingtreatment withwater proffing compoundCement concrete 1:2:4 (1 cement : 2 coarse sand : 4gradedstoneaggregate20mmnominalsize) 7 Providingandfixing1stqualityMAT finishedceremictilesize300x300mm confirming toIS:13755andIS:15622 colour suchaswhite,grey,ivory,fumered brown, light green, light blue and other light shades in floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointinginthewhitecementmixedwith pigment to match the shade of the tile complete (including the cost of cement mortar bed 1:4). 8 Providingandfixing1stqualitystandard white,grey,ivory,fumeredbrown,light green,lightblueandotherlightshades glazedtilesconfirmingtoIS:13753&IS :15622ofsize200mmx300mminwalls, floors,steps,pillarsetc.laidonabedof neat cement slurry finished with flush pointinginthewhitecementmixedwith pigment to match the shade of the tile complete (excluding the cost of cementplaster on walls and pillar). 9 Providing and fixing pressed steel door frames confirming to IS 4351 manufactured fromcommercialmildsteelsheetof1.25 mmthicknessincludinghingesjamb,lock jamb,beadandifrequiredanglethreshold ofmild steel angle ofsection50x25mm, or basetiesof1.25mmpressedmildsteel welded or rigidlyfixed together by mechanical means, adjustable lugs with splitendtailtoeachjambincludingsteel butt hinges 2.5mm thick with mortar guards, lockstrike-plateandshockabsorbersas specifiedandapplying acoatofapproved steel primer after pre-treatment of the surfaceincludingfillingwithCC1:2:4(M15 grade) complete as directed by Engineer-in- charge : Profile C 10 Providing and fixing in position collapsible steel shutters with vertical M.S. Channels 20 x 10 x 2mm and bracket with flat iron diagonals 20 x 5mm. size with top and bottom rail of Tiron 40 x 40 x 6mm. with 40mm dia steel pulleys/ball bearing complete with bolts, nuts locking arrangements inside and outside stoppers, handles etc. as per specification including applying a priming coat of approved steel primer. (To be measured and paid as per outer dimension). 11 Providing and fixing M.S. sheet 1mm thicksingle leaf door shutter in angle iron frame 35x35x5mm suitabilly diagonally braced with 25x3mm flat iron above and below lock rail of size 50x5mm beading extra including all fittings, as per direction of Engg. incharge but excluding cost of chowkhats: including two coats of anit-corrosive red oxide primer paint Add extra for double leaf shutters. 12 Finishing wall with water proofing cement paint of approved brand and manufacture and or required shade to give an even shade including all scaffolding:12.41.1 New work (Two or more coats applied @ 3.84 kg/10 sqm) 13 Distempering with oil bound washable distemper of approvedbrand and manufacture to give an even shade including allscaffolding:New work (two or more coats) over and includingscrappingandprimingcoatwithcement primer. 14 Painting with synthetic enamel paint of approvedbrandandmanufactureto give an even shade : Two or more coats on new work 15 Structural steel workin singlesection fixed withorwithoutconnectingplateincluding cutting,hoisting(heightupto10m),fixing inpositionandapplyingaprimingcoatof approved steel primer all complete. 16 Repairs to plaster of thickness 12mm to 20mm in patches of area 2.5 sq. metres and under including cutting the patch inproper shape, raking out joints and preparing and plasteringthe surface of the walls complete including disposal of rubbishto the dumping ground within 50 m lead With cement mortar1 :4 ( 1 cement : 4 coarse sand) 17 Providingandfixing aluminumwork for doors ,windows, ventilators and partition withextrudedbuiltupstandardtubular/ appropriate Z sections and other sections of approvedmakeconformingtoIS:733and IS :1285, fixed with rawl plugs and screws orwithfixingclips,orwithexpansionhold fastenersincludingnecessaryfillingupof gap. at junctions , at top ,bottom and sides withrequiredPVC/neoprenefeltetc. Aluminiumsection shallbe smooth,rust free,straight,miteredandjointed mechanically wherever required including cleat angle Aluminiumsnap beading for glazing /paneling , C.P. brass/ stainless steelscrewsAl.Tower bolt&Al.handle& Al. Aldrop etc.,allcomplete asper architectural drawings and thedirections of Engineer-in–charge.(Glazingand panelingto be paid forseparately).For fixed portion Anodised aluminum (anodised transparent 81 dyed to required shade accordingtoIS:1868.(Minimumanodic coating of grade AC 15, Anodizing to be got done from approved Anodizer) 18 (B) For shutters builtup standard tubular sections of openable doors ,windows & ventilators including providing & fixing hinges / rollers etc. and making provision for fixing offittings wherever required (lockes shall be paid for separately). Powder coating aluminum ( minimum thickness of powder coating 50 micron) 19 Providing and fixing glazing in aluminium door, window ,ventilator shutters and partitions etc. with PVS / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge.(Cost of aluminium snap beading shall be paid in basicitem.) With float glass panes of 8 mm thickness 20 Providingand fixingaluminiumUshape handleofsize100mm withSSscrews etc. CompleteasperdirectionofEngineer-in- charge Anodized (AC 15 ) aluminium 21 Providingand fixing100mmbrasslocks (bestmakeofapprovedquality)for aluminium doors including necessarycutting and making good etc. complete. 22 Providing and fixing double action hydraulic floorspringofapprovedbrandand manufactureIS:6315marked,fordoors includingcostofcuttingfloorsasrequired, embeddinginfloorsandcoverplateswith brass pivot and single piece M.S. Withbrass cover plate 23 S&f fixed wire gauge of stainless steel of 14 mesh x 24 gauge to thealuminium window by Aluminium beading 20x3mm with suitabl screws not exceeding 150mm distance at all heights with all lead and lift with scafolding 24 Providing and fixing stainless steel railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required)and fitting the same with necessary stainless steel nuts andbolts complete, i/c fixing the railing with necessary accessories & stainless steel dashfasteners , stainless steelbolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval ofEngineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixingaccessories such as nuts, bolts, fasteners etc.).Grade 204 25 Providing & laying broken glazed titles on roof ( brokenglazed tiles not less than 9 Kg/Sqm) on top of hot bitumen @ 1.7 Kg/Sqm. (1.40 Kg of VG-40 (30/40 )grade and 0.30Kg/Sqm. Of VG-10 (80/100) grade) and joints filled with cement mortar 1 :2 (1 cement:2 marble dust mixed with water proofing compund all complete as per direction of Engineerin-charge 26 Providing and fixing 12.5 mm thick tapered edge gypsum board conforming to IS 2095- Part I at all height false ceilingincluding providing and fixing of frame work made of special sections power pressed from M.S. sheet and galvanised inaccordance with zinc coating of grade 350 as per IS : 277 and consisting of angle cleats of size 25mm wide x 1.6mm thick with flanges of 22mm and 37mm at1200mm centre to centreone flange fixed to the ceiling with dash fastener 12.5mmdiax40mm long with 6mm dia bolts to the angle hangers of 25x25x0.55mm of required length, and other end of angl hanger being fixed with nut and bolts toG.I. channels45x15x0.9mm running at the rate of 1200mm centre to centreto which the ceiling section 0.5mm thick bottom wedge of 80mm with tapered flanges of 26mm each having clips of10.5mm at 450mm centre to centre shall be fixed in a direction perpendicular to G.I. channel with connecting clipsmade out of 2.64mm diax230mm long 27 5 mm float glass 28 PART - B : SANITARY WORK 29 P & F Indian type white glazed vitreous china 1stqualityW.C.orissapan(IS:2556Mark) with100mm vitreouschinaPor Strap includingcuttingandmakinggoodthewall and floor: Size 580x440mm. 30 P & F European type white glazed vitreous china 1st quality Double syphonic W.C (IS :2556 Mark) with P or S trap including cutting and making good the wall and floor 31 P & F Low level Flushing Cistern of10 litres capacity (IS : 2556mark). Ofapproved make with complete fittings C.I. brackets duly painted,brassballcockwithball,(IS:1703 mark) complete including cutting and making good the wall: WVC with C.P. brass bend. 32 P&FLookingMirrorswithP.V.C.frameof approved make as per direction of Engineer-in-charge Size 500x400mm 33 P & F Towel Rail or Ring of approved quality/make: C.P. brass Towel Rail elbow type with concealed screws size 450mm (Heavy duty). 34 P&FLiquidSoapContainerwithbracketscomplete of approved make: C.P. brass 35 P&FJetsprayforwaterclosetwithC.P.Copper Tube flange of approved make. 36 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC)pipes (IS 15778 : 2007 code) having thermal stability for hot& cold water supply including all CPVC plain & brassthreaded fittings i/c fixing the pipe with clamps at 1 metrespacing. This includes jointing of pipes &fittings with onestep CPVC solvent cement and testing of joints complete asper direction of Engineer in Charge. (Internal work Exposedon wall) 37 20mm nominal size 38 Providing and fixing Chlorinated PolyvinylChloride (CPVC)pipes (IS 15778 : 2007 code) having thermal stability for hot& cold water supply including all CPVC plain & brassthreaded fittings, this included jointing of pipes & fittings withone step CPVC solvent cement , trenching refilling & testingof joints complete as per direction of Engineer in Charge. (External work 39 25 mm nominal size 40 P & F Bib Cock (IS : 8931 Mark), Superior quality of approved make: C.P. Brass bibcock,15mm nominal bore. 41 P & F Inlet Connection (Angle Valves) Superior quality, of approved make, for Wash basin, Gyser etc. C.P. Inlet connection 15mm.Brass (IS : 8931 marked) 42 P & F Square-mouth gully trap `A` grade (IS 651-1992:marked)ofapprovedmake completewithC.I.grating,frame&Cover masonary chamber in C.M. 1:6, 100mm thick C.C. 1:5:10 base concrete, 40mm thick C.C.M 15 grade coping, 12mmthick cement plaster in CM 1:3 complete as per approved design & type. Trap size 150 X 100mm, ferrow cement coverwithframe,Internal Chambersize 300 X 300mm. 43 P&F rigid PVC pipe fittings (IS: 4985 mark) of approvedquality/makeincludingjoiningthe pipewithsolvent cementrubber ringandlubricant: 44 Plain Tee 110mm dia 45 Bend 45 110mm dia 46 Plain floor trap 110mm dia 47 Construction of chamber in all type of soil with 300mmthickmasonryinCM1:6m,10cm thickC.C.1:5:10infoundation,20mmthick insider plaster in Cm 1:6, finished with floating neatcement,50mmthickM-15gradeC.C. flooring , earthwork etc. complete as per design including disposal of surplus earth withinaleadof50mtr.-do--do- size 450 x 450mm depth upto0.5 M Cement cover with frame 48 Construction of soakage well in all type of soil with 300 mm thick dry masonry, top and bottom 300 mm course in CM 1:6, 80mm thick stone slab, jointing of slab in CM 1 : 3, Ralthal, Kharanja, 40 mm thick M-15 grade C.C flooring , earthwork complete as per approved drawing including disposal of earth within a lead of 50 mtr.: Size 300 Cm. dia outside & 300 Cm. depth . 49 Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes Type B for scilandwastedischargesystem(IS:13592: 1992 Marked) of approved quality /make 110mm dia 50 Providing and Fixing Unplasticized Poly Vinyl Chloride(UPVC)SWRPipesfittingstypeB for sciland waste discharge system (IS:13592 : 1992 Marked) of approved quality /make 51 Bend 87.5 Dg. 110mm dia 52 Single Tee 110mm dia 53 Nahni Trap with Jali 4” 110mm dia 54 P & F Sink Cocks of superior quality & approved made : C.P. Sink cock swinging spout 15mm. 55 P&FPVCStorageTankISIMarked(IS: 12701)indicatingthe BISlicenseNo), of approvedmakewithcover,25mmdia1M long G.I. over-flow pipe & 25 Cm. long wash out pipe with plug & socket, including making connection etc., complete of approved design: 1000 (-do-) 56 Construction of manhole in all type of soil inner size 90 X 60 Cm. 300 mm thick masonry in CM 1:6, 10 Cm. thick cement concrete 1:5 10 in foundation, 20 mm thick inside plaster in CM 1:6, finished with floating neat cement, 50mm thick M-15 grade C.C. flooring, making channels, 80mm thick stone slab covering with 40mm thick M-15 grade C.C. flooring, Cement cover with frame of 450mm dia, earthwork etc. complete as per design including disposal of surplus earth within 50 mtr. lead. Depth up to 0.5 M 57 P&FSand–castFloorTrap(Nahni)of (IS:1729 mark) of approved quality/make with socket down or hinged grating including cutting and making good the floor. 58 Size 100 x 75mm 59 Size 100 x 50mm 60 P&F Sand-cast Iron (S.C.I.) Pipe (IS: 1729mark)ofapprovedmakeinwallorin floor with M.S. holder bat clamps in 10 X 10 X 10Cm.M-15gradeconcreteblocks,joints filledwithCM1:4withspunyarnincluding cutting holes and making good the wall: 61 100mm dia 62 P&FS.C.I.Fittings(IS:1729mark)inCM 1:4 with spun yarn. 100mm-do- 63 Offset 64 Socket 65 Cowel 66 Tee 67 Bend 68 P & F Ball Cock (IS :1703 Mark) with Rod& P.V.C. Ball complete : Brass wt.400 gm,15mm.