| 1 | Excavating in trenches not exceeding 0.50 m wide and 0.75 m depth s and getting it out in soft/loose soil for laying of U/G cable.Complete all as specified & directed. Note: Digging by JCBs are not allowed. |
| 2 | Sand cushioning in cable trenches 15 cm thick including material & labour. |
| 3 | Supplying& laying unreinforced precast concrete cable cover class LVtype 3 with Flat size 450mmx180mmx40mm with identification of cable cover with material & labour. |
| 4 | Returning filling soft/loose soil in including spreading,levelling,watering and well ramming in layers not exceeding 25 cm |
| 5 | S & L steel water tubing (GI pipe) medium grade 100 mm dia with all fittingslaid in trenches withM & L. |
| 6 | S & L steel water tubing (GI pipe) medium grade 80 mm dia with all fittingslaid in trenches withM & L. |
| 7 | S & L steel water tubing (GI pipe) medium grade 50mm dia with all fittingslaid in trenches withM & L . |
| 8 | S & L steel water tubing (GI pipe) medium grade 40mm dia with all fittingslaid in trenches withM & L . |
| 9 | S & L steel water tubing (GI pipe) medium grade 20 mm dia with all fittingslaid in trenches with M & L. |
| 10 | Demolition & dismantling of cement concrete (unreinforced) in ground floor & paving not exceeding 15 cm thick below or above ground level. |
| 11 | M&L cement concrete in foundations Type B2 ,mixed by volume 1:2:4 with 40 mm graded aggregate.Complete all as specified & directed. |
| 12 | Brick work with subclass \"B\" bricks, straight or curved on plan exc 6m mean radius built in cement mortar 1:4. |
| 13 | Excavating over areas, not exceeding 0.5 m deep and getting out soft/loose soil. Complete all as specified & directed. |
| 14 | Hardcore of gauge not exc. 63 mm, deposited, spread and levelled in layers not exc. 8 cm thick, watered and rammed to a true surface broken stone or boulders with M&L. Complete all as specified & directed. |
| 15 | Shingle filling in floors or pavings, laid in layers n exc. 2.5 cm thick, spread, levelled, and blinded with earth and rammed including watering. Complete all as specified & directed. |
| 16 | Cement concrete type B-1, 1:2:4 (20 mm graded aggregate) 145mm thick, foregoing for reinforced, finishing cement concrete surface even and smooth without using extra cement.Complete all as specified & directed. |
| 17 | Mild steel TMT bars 6mm to 8mm dia cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not lass than 0.9 mm dia or securing with clips. Complete all as specified & directed. |
| 18 | Renderig 15mm thick on for fair faces of brick work or concrete sur-face cement plaster 1:4 & rendering is to be finished even and smooth (without using extra cement). Complete all as specified & directed. |
| 19 | Supply & layingXLPE insulated armoured Heavy Duty , electric cable with aluminium conductor, 1100 Volt grade cross- sectional area 10 sq.mm 4 core without jointincluding termination of both the ends with proper lugs with M & L. Complete all as specified & directed. Make of Cable : Havells/Sterlight/Unistar/Finolax/Polycab/KEI or equivalent. |
| 20 | Supply & layingXLPE insulated armoured Heavy Duty , electric cable with aluminium conductor, 1100 Volt grade cross- sectional area 16 sq.mm 2 core without jointincluding termination of both the ends with proper lugs with M & L. Complete all as specified & directed. Make of Cable : Havells/Sterlight/Unistar/Finolax/Polycab/KEI or equivalent. |
| 21 | Supply & layingXLPE insulated armoured Heavy Duty , electric cable with aluminium conductor, 1100 Volt grade cross- sectional area 16 sq.mm 4 core without jointincluding termination of both the ends with proper lugs with M & L. Complete all as specified & directed. Make of Cable : Havells/Sterlight/Unistar/Finolax/Polycab/KEI or equivalent. |
| 22 | Supply & layingXLPE insulated armoured Heavy Duty , electric cable with aluminium conductor, 1100 Volt grade cross- sectional area 70 sq.mm 3½ core without jointincluding termination of both the ends with proper lugs with M & L. Complete all as specified & directed. Make of Cable : Havells/Sterlight/Unistar/Finolax/Polycab/KEI or equivalent. |
| 23 | Supply & layingXLPE insulated armoured Heavy Duty , electric cable with aluminium conductor, 1100 Volt grade cross- sectional area 95 sq.mm 3½ core without jointincluding termination of both the ends with proper lugs with M & L. Complete all as specified & directed. Make of Cable : Havells/Sterlight/Unistar/Finolax/Polycab/KEI or equivalent. |
| 24 | Supply & layingXLPE insulated armoured Heavy Duty , electric cable with aluminium conductor, 1100 Volt grade cross- sectional area 120 sq.mm 3½ core without jointincluding termination of both the ends with proper lugs with M & L. Complete all as specified & directed. Make of Cable : Havells/Sterlight/Unistar/Finolax/Polycab/KEI or equivalent. |
| 25 | Supply & layingXLPE insulated armoured Heavy Duty , electric cable with aluminium conductor, 1100 Volt grade cross- sectional area 185 sq.mm 3½ core without jointincluding termination of both the ends with proper lugs with M & L. Complete all as specified & directed. Make of Cable : Havells/Sterlight/Unistar/Finolax/Polycab/KEI or equivalent. |
| 26 | Crossarms,bracings,supports, clampsandbackplatesfabricated fromstructuralsteelsections includingnuts,bolts,washers, welding,bendingcoldorhot, drilling holes for bolts, in any shape or size as indicated or directed and inclusiveofoneprimercoat,one under coat and one finishing coat of paint with material and labour. |
| 27 | Dismatling cross arm of MS channels or angle section etc complete and setting aside for reuse. |
| 28 | Dismantling insulator any type any size |
| 29 | Dismantling earth wire or copper conductor service feeder or distribution span. |
| 30 | Dismantling of ACSR or AAC conductors |
| 31 | Earthing complete with GI plate electrode 600x600x6.0mm thick burried directly in ground (earth plate not less than 2.25m below ground level) including excavation of soil, with top edge of the plate not less than 1.5m below normal ground level and duly filled with alternate layer of char coal & salt from 150mm below the plate to 150mm above the plate (total 900mm thick) connected to GI earth strip size 25x4mm in GI protection pipe of size 40mm dia upto 7.5m long by means of nuts, bolts, washers, check nuts of GI steel, fitted with funnel complete all as per procedure and as shown in SSR electrical plate No. 3. Connected to earth test point/earth bus (to be provided near incoming mains) all as specified and testing including RCCearth pit chamber duly cement plaster finished and RCC pit cover 1mX1mX150mm, PCC hard standing surrounding the earth pit chamber, location of the earth pit marked on the nearest wall to be written with paint (for distance & value of earth pit) with material and labour. Earth pit chamber will be made 0.5m above the ground level. |
| 32 | Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection, complete with fitting pipe clamp etc. Make: Polycab/C&S/Phillips/Havells/Anchor or equivalent. |
| 33 | Supply & Fix switch with sheet steel inclosure 500V, 3 phase with HRC fuses complete with Neutral link of capacity 200 Amps.Make: English Electric/ SSK /C&S/Standard/Havells or equivalent. |
| 34 | Supply Installation & Commissioning of LT bus bar panel (cable adopter box ) made ofSheet metal Cubical outdoor type pole mounted, dust & vermin proof IP 65/54 protection, made of 2mm CRCA sheet steel, size 700mm x 500mm x 250mm, panel duly painted with two coat of red oxide primer and over all painted with two coat of synthetic enamel paint hammer grey colour. Mounted on 4 No MS Angle of size 40x40x5 mm . Panel shall haveTPN BUS BAR, 3 phase, 4 wire, of Electrical gradeAluminum. Bus bar rating current should not be less than 600 A capacity, voltage- 415V. Bus Bar Shall be insulated with colour coated heat shrinkable sleeve and shall be mounted on DMC/Epoxy insulators including termination of incoming & outgoing cable with lugs & glands, complete all as specified and directed. |
| 35 | Supply Installation & Commissioning of L.T. control outdoorpanel consisting of :-1. Incomer (a):- MCCB 200 A4 pole, 415 V, 50 Hz, TM Based, 36KA with spreader link & extended Handle) Qty – 1 No.Make: Siemens/Schneider/L&T/ABB/Havells or equivalent. (b) Digital Multifunction meter (intelligent type), Qty -1No. Make - Conzerv/Secure/AE or equivalent. (c)CT (200/5A CL-1.0), mould case type for metering, Qty - 3 No. Make:Conzerv/Newtek/AE. (d) LED indication R, Y, B, Qty - 3 No. Make: Pricifine/AE/conzerv or equivalent. (e) 6A SP control MCBQty - 6 No. Make: Siemens/ L&T/ Schneider/ABB/Havells or equivalent.2. Outgoings:- (a) MCCB 200 A4 pole, 415 V, 50 Hz, TM Based, 36KA with spreader link & extended Handle)Qty- 1No. (b) MCCB 100 A, 4 pole, 415 V, 50 Hz, TM Based, 16KA with spreader link & extended Handle)Qty- 2No. Make MCCB: Siemens/ L&T/ Schneider/ABB/Havells or equivalent. 3. Panel:- Outdoor type with extended rain shed, IP protection- IP 54, Paint shade- RAL 7035, TPN aluminum Busbar - 600Amp.Panel specification - As per annexture \"A\" attached. |
| 36 | Supply Installation & Commissioning of L.T. control out-door type panel fitted with following items:1. Incomer(a)TPN switch fuse unit with HRC fuse315A,415 V,4 pole, 3KA8with extended spreader link & handle.Qty - 01 No. Make of switch fuse unit : Siemens/C&S/L&T/ABB/Havells or equivalent. (b) Digital Multifunction meter (intelligent type), Volt-meter, Amps-meter, V&AM meter selector switch Qty -1No. Make - Conzerv/Secure/AE or equivalent. (c)CT (315/5A CL-1.0), mouldcase type for metering , Qty - 3 No. Make:Conzerv/Newtek/AEor equivalent(d) LED indication R, Y, BQty - 3 No. Make: Pricifine/AE/conzerv or equivalent. (e) 6A SP control MCBQty - 6 No. Make: Siemens/Schneider/L&T/ ABB/Havells or equivalent. 2. Outgoing:- (a) Switch fuse unit with HRC fuse, 3 Phase, 415 V, 100Amps, 3KL,Qty – 04 No. (b) Switch fuse unit with HRC fuse, 3 Phase, 415 V, 63 Amps, 3KL, Qty – 01 No. Make of Switch fuse unit :Siemens /C&S/L&T/CG/ Havells or equivalent. 3. Outdoor type(with extended rain shed), IP protection- IP 54, Paint shade- RAL 7035, TPN aluminium Busbar - 600Amp.4. Panel specification - As per annexture \"A\" attached. |
| 37 | Supply Installation & Commissioning of L.T. control out-door type panel fitted with following items:1. Incomer(a)TPN switch fuse unit with HRC fuse250A,415 V,4 pole, 3KA8with extended spreader link & handle.Qty - 01 No. Make of switch fuse unit : Siemens/C&S/L&T/ABB/Havells or equivalent. (b) Digital Multifunction meter (intelligent type), Volt-meter, Amps-meter, V&AM meter selector switch Qty -1No. Make - Conzerv/Secure/AE or equivalent. (c)CT (250/5A CL-1.0), mouldcase type for metering , Qty - 3 No. Make:Conzerv/Newtek/AEor equivalent(d) LED indication R, Y, BQty - 3 No. Make: Pricifine/AE/conzerv or equivalent. (e) 6A SP control MCBQty - 6 No. Make: Siemens/Schneider/L&T/ ABB/Havells or equivalent. 2. Outgoing:-Switch fuse unit with HRC fuse, 3 Phase, 415 V, 100Amps, 3KL,Qty – 02 No. Make of Switch fuse unit :Siemens /C&S/L&T/CG/ Havells or equivalent. 3. Outdoor type(with extended rain shed), IP protection- IP 54, Paint shade- RAL 7035, TPN aluminium Busbar - 400Amp.4. Panel specification - As per annexture \"A\" attached. |
| 38 | Supply Installation & Commissioning of outdoor L.T. distribution panel (Marshalling box) with following specifications:- (1) Material - Sheet metal enclosures should not be less than 2.0 mm CRCA, dust & vermin proof. (2) Gasket: Synthetic foam/Neoprene. (3) Dimension - 450(L) x 650 (H) x 182 (D) mm (approx). (4) Degree of Protection - confirming to IP 54/65 as per IEC61439/IS 8623-1 or equivalent of Indian standard. (5) Pre - Treatment & powder coating: The sheet metal undergoes 12- tank Hot pre - treatment process this process involves degreasing, de-rusting, Phosphating, passivation, finally the interior & exterior of the panel shall be coated with pure polyester based powder grey shade - RAL - 7035, powder coating system should be fully automaticfor touch less operation.(6) Finish - RAL 7035. (7) Accessories - RAL 7035/7032 (8) Mounting structure- RAL 7016.(9) Mounting Type - Outdoor/Pole mounted. (10) Cable Entry - I/C & O/G from bottom. (11) System voltage - 415 V, 50 Hz, 4 wire +E.(12). Busbar rating - 200A (RYBN ) aluminium.(13) Outgoing:-32 A, MCB, SP 10 KAQty - 03 No.Make of Panel & MCB: Siemens/ L&T/ Crompton Greaves/ C&S/ GE/ ABB or equivalent. |
| 39 | Supply Installation & Commissioning of outdoor L.T. distribution panel (Marshalling box) with following specifications:- (1) Material - Sheet metal enclosures should not be less than 2.0 mm CRCA, dust & vermin proof. (2) Gasket: Synthetic foam/Neoprene. (3) Dimension - 450(L) x 300 (H) x 182 (D) mm (approx). (4) Degree of Protection - confirming to IP 54/65 as per IEC61439/IS 8623-1 or equivalent of Indian standard. (5) Pre - Treatment & powder coating: The sheet metal undergoes 12- tank Hot pre - treatment process this process involves degreasing, de-rusting, Phosphating, passivation, finally the interior & exterior of the panel shall be coated with pure polyester based powder grey shade - RAL - 7035, powder coating system should be fully automaticfor touch less operation.(6) Finish - RAL 7035. (7) Accessories - RAL 7035/7032 (8) Mounting structure- RAL 7016.(9) Mounting Type - Outdoor/Pole mounted. (10) Cable Entry - I/C & O/G from bottom. (11) System voltage - 415 V, 50 Hz, 4 wire +E.(12). Busbar rating - 200A (RYBN ) aluminium.(13) Outgoing:-6 A, MCB, SP 10 KA . Qty - 01 No.(14) Connection from marshalling box to street light fitting with 2x1.5 sq mm copper cable (approx 7 meter length) shall be indrawn in existing pipe.Complete with material & labour.Make of Panel & MCB: Siemens/ L&T/ Crompton Greaves/ C&S/ GE/ ABB or equivalent. |
| 40 | Disconnection of existing service cables PILC/PVC up to 16/25 sq mm 4 core cable from pole and termination in new panel (Cable adopter box)fixed on pole,with proper gland, lugs & insulation. disconnection& termination of the cable should be done carefullywithout any damage.Complete all as specified & directed. |
| 41 | Supply & fixing Cable route marker of Cast Iron size 150mm x 100mm x 3mm thick, embosing 440 volt, U/G LT cable & size, fixed with nuts & bolts on MS angle iron size 40mmx40mmx5 mm,length 1700 mm, burried 500mm in the groundwith cement concrete (1:3:6) of size (200mmx200mmx300mm) with material & labour. |
| 42 | Boring holes/ auguring not exceeding 150mm dia 1m deep for passing HT/LT under ground cable across the road/gantry. complete all as specified & directed. |
| 43 | S & F on street light pole out door type marshalling box of FRP, IP-65 Size minimum 200x200x150 mm approx with holding clamp Din rail & C rail for holding connectors, one single pole MCB, 6A,230V & 6 wayelmex connectors size 16 sq mm, including connection of street light with PVC insulated sheathed stranded Cu wire of size 1.5 sq. mm up to 2x7 mtrs. for each pole complete with material & labour. Complete all as specified & directed. |
| 44 | Dismantled/scrap copper conductor |
| 45 | Dismantled/scrap Aluminium conductor. |
| 46 | Dismantled/scrap ms Cross arms, ms channels, ms angles etc. |