}

Tender For Electric And Ac Work At Mlp Rajkot => Limited, rajkot-Gujarat

Union Bank Of India has published Tender For Electric And Ac Work At Mlp Rajkot => Limited. Submission Date for this Tender is 03-10-2025. Air Conditioner Tenders in rajkot Gujarat. Bidders can get complete Tender details and download the document.




Tender Notice

51118248
Tender For Electric And Ac Work At Mlp Rajkot => Limited
Tender
Indian
Gujarat
Rajkot
03-10-2025
BootCamp

Tender Details

Tender For Electric And Ac Work At Mlp Rajkot => Limited; PART- I - ELECTRIC WORK:- 1.0.0 Supply, installation, testing and commissioning of following point wiring as per the specifications and drawings. The unit rate for the switch board and further to point outlet including all hardware, connector strips, fan hook, outlet boxes, switch boards, switch plates, switches, wire conduits etc. A point shall include in addition to phase and neutral wire, a PVC insulated earth-continuing wire from L. P. to the final termination at outlet points. All the wiring should be done in concealed / semi concealed open manner or slab / wall / false ceiling. The wiring should be done with rigid PVC conduits / Casing - capping having minimum of 1.6 mm wall thickness and minimum 19mm dia with 440V grade PVC insulated. ISI approved copper conductor wire, with crabtree/ ROMA make switches and accessories with company boxes for point outlet and SB and with all required hardware accessories to complete the wiring. No junction boxes are allowed any where in the wiring. All joints shall be done at point outlet on switch boards only. In between joints are not allowed anywhere. The wiring shall be done as per IS 732 and IS 4648. a) Making Zari in the wall & sami finishing the surface. b) Ball and socket joint wherever required. c) Earthing of fittings d) Electrical connections from the outlet points to the fixture with 3 core flexible wire. RATE ARE INCLUDING MAINS CIRUITS 1.1.0 One Light Point Controlled By One 5 Amp. Switch:- A) Wire Size: Lighting DB to Switch Board Circuit: Phase Wire -Red/Yellow/Blue Color - 2.5. sq. mm-1 no. Neutral Wire -Black Color -2.5. sq. mm-1 no. Earth Wire -Green Color -1.5. sq. mm-1 no. B) Wire Size: Switch to Light Point Circuit: Phase Wire -Red/Yellow/Blue Color -1.5. sq. mm-1 no. Neutral Wire -Black Color -1.5. sq. mm-1 no. Earth Wire -Green Color -1.0. sq. mm-1 no C) FRLS Wire : RR Kabel/Polycab/Havells/Finolex D) Modular Switch : Crabtree/Legrand/ABB/Anchor E) PVC Conduit & Accessories Make : Precision / Polycab / Nihir / Vraj 15.00 Nos. 1.2.0 Two Light Points Controlled By One 5 Amp. Switch:- A) Wire Size: Light Point to Light Point Circuit: Phase Wire - Red/Yellow/Blue Color - 1.5. sq. mm-1 no. Neutral Wire - Black Color -1.5. sq. mm-1 no. Earth Wire - Green Color -1.0. sq. mm-1 no. B) FRLS Wire : RR Kabel/Polycab/Havells/Finolex C) Modular Switch : Crabtree/Legrand/ABB/Anchor D) PVC Conduit & Accessories Make : Precision / Polycab / Nihir / Vraj 10.00 Nos. 1.3.0 Three Light Points Controlled By One 5 Amp. Switch:- A) Wire Size: Light Point to Light Point Circuit: Phase Wire - Red/Yellow/Blue Color - 1.5. sq. mm-1 no. Neutral Wire - Black Color -1.5. sq. mm-1 no. Earth Wire - Green Color -1.0. sq. mm-1 no. B) FRLS Wire : RR Kabel/Polycab/Havells/Finolex C) Modular Switch : Crabtree/Legrand/ABB/Anchor D) PVC Conduit & Accessories Make : Precision / Polycab / Nihir / Vraj 10.00 Nos. 1.4.0 One 5 Amp. Switch & Socket Controlled For Wall Fan Point:- A) Wire Size: Light Point to Light Point Circuit: Phase Wire - Red/Yellow/Blue Color - 1.5. sq. mm-1 no. Neutral Wire - Black Color -1.5. sq. mm-1 no. Earth Wire - Green Color -1.0. sq. mm-1 no. B) FRLS Wire : RR Kabel/Polycab/Havells/Finolex C) Modular Switch : Crabtree/Legrand/ABB/Anchor D) PVC Conduit & Accessories Make : Precision / Polycab / Nihir / Vraj 6.00 Nos. 1.5.0 One 5 Amp. 5 Pin Socket Outlet Controlled By One 5 Amp. Switch Looped On Switch Board:- A) Wire Size: loop Circuit: Phase Wire -Red/Yellow/Blue Color -1.5. sq. mm-1 no. Neutral Wire -Black Color -1.5. sq. mm-1 no. Earth Wire -Green Color -1.0. sq. mm-1 no. B) FRLS Wire : RR Kabel/Polycab/Havells/Finolex C) Modular Switch : Crabtree/Legrand/ABB/Anchor D) PVC Conduit & Accessories Make : Precision / Polycab / Nihir / Vraj 7.00 Nos. 1.6.0 Three 5 Amp. 5 Pin Socket Outlet Controlled By One 5 Amp. At Other Convenient Location For Computer. (Maximum 4 Nos. Of Boards In One UPS Circuit):- A) Wire Size: UPS DB to Switch Board Circuit: Phase Wire -Red/Yellow/Blue Color -2.5. sq. mm-1 no. Neutral Wire -Black Color -2.5. sq. mm-1 no. Earth Wire -Green Color - 1.5. sq. mm-1 no. B) FRLS Wire : RR Kabel/Polycab/Havells/Finolex C) Modular Switch : Crabtree/Legrand/ABB/Anchor D) PVC Conduit & Accessories Make : Precision / Polycab / Nihir / Vraj 26.00 Nos. 1.7.0 Two 5 Amp. 5 Pin Socket Outlet Controlled By One 5 Amp. At Other Convenient Location For RAW POWER. (Maximum 4 Nos. Of Boards In One UPS Circuit):- A) Wire Size: UPS DB to Switch Board Circuit: Phase Wire -Red/Yellow/Blue Color -2.5. sq. mm-1 no. Neutral Wire -Black Color -2.5. sq. mm-1 no. Earth Wire -Green Color - 1.5. sq. mm-1 no. B) Wire Size: Switch to Socket Point Circuit: Phase Wire -Red/Yellow/Blue Color -1.5. sq. mm-1 no. Neutral Wire -Black Color -1.5. sq. mm-1 no. Earth Wire -Green Color - 1.0. sq. mm-1 no. C) FRLS Wire : RR Kabel/Polycab/Havells/Finolex D) Modular Switch : Crabtree/Legrand/ABB/Anchor E) PVC Conduit & Accessories Make : Precision / Polycab / Nihir / Vraj 26.00 Nos. 1.8.0 One Buzzer Point Controlled By One Bell Push, With Electric Type Buzzer:- A) Wire Size: Switch to Buzzer Point Circuit: Phase Wire -Red/Yellow/Blue Color -1.5. sq. mm-1 no. Neutral Wire -Black Color -1.5. sq. mm-1 no. Earth Wire -Green Color - 1.0. sq. mm-1 no. B) FRLS Wire : RR Kabel/Polycab/Havells/Finolex C) Modular Switch : Crabtree/Legrand/ABB/Anchor D) PVC Conduit & Accessories Make : Precision / Polycab / Nihir / Vraj 1.00 Nos. 1.9.0 One 5 Amp. 5 Pin Socket Outlet Controlled By One 5 Amp. Switch At Other Convenient Location For Exhaust Fans:- A) Wire Size: Switch to Socket Point Circuit: Phase Wire -Red/Yellow/Blue Color -1.5. sq. mm-1 no. Neutral Wire -Black Color -1.5. sq. mm-1 no. Earth Wire -Green Color - 1.0. sq. mm-1 no. B) FRLS Wire : RR Kabel/Polycab/Havells/Finolex C) Modular Switch : Crabtree/Legrand/ABB/Anchor D) PVC Conduit & Accessories Make : Precision / Polycab / Nihir / Vraj 3.00 Nos. 1.10.0 One 15 Amp 6 Pin Socket Outlet Controlled By One 15 Amp. Switch With Indicator (For Router/Printer /Appliance etc.) (Separate And Independent Circuit Required):- A) Wire Size: Lighting/Power DB to Switch Board Circuit: Phase Wire - Red/Yellow/Blue Color -2.5. sq. mm-1 no. Neutral Wire -Black Color -2.5. sq. mm-1 no. Earth Wire -Green Color -1.5. sq. mm-1 no. B) FRLS Wire : RR Kabel/Polycab/Havells/Finolex C) Modular Switch : Crabtree/Legrand/ABB/Anchor D) PVC Conduit & Accessories Make : Precision / Polycab / Nihir / Vraj 2.00 Nos. 1.11.0 One 20 Amp. 6 Pin Socket Outlet Controlled By One 20 Amp. Switch Or 20 Amp. SP MCB With Socket For A. C. Unit. (If Circuit Wire Connected Direct And Without Switch/Socket/MCB To Outdoor AC Unit- 50% Quoted Tender Rate Will Be Paid):- A) Wire Size: AC/Power DB to AC Point Circuit: Phase Wire -Red/Yellow/Blue Color - 4.0 sq. mm-1 no. Neutral Wire -Black Color -4.0 sq. mm-1 no. Earth Wire -Green Color -1.5. sq. mm-1 no. B) FRLS Wire : RR Kabel/Polycab/Havells/Finolex C) Modular Switch : Crabtree/Legrand/ABB/Anchor D) MCB : Havells/Legrand/ABB/Schneider E) PVC Conduit & Accessories Make : Precision /Polycab /Nihir / Vraj 4.00 Nos. 2.0.0 Cables & Cable Terminations:- Supplying & laying PVC armoured cable of 1100 V grade of copper / conductor ( as specified) of following sizes in ready made trench mounted on wall with necessary clamping arrangement or in prelaid RCC hume pipe with necessary cable identification lugs at both ends, digging of trench and its filing with second call bricks, send. The cable shall ISI mark and conforming to latest ISS. All the cable shall be terminated with suitable sizes of Lugs. 2.1.0 3C X 6 sq mm Copper Flexible cable (for UPS Input / Output) FRLS Wire : RR Kabel/Polycab/Havells/Finolex. 50.00 R.MT 2.2.0 3.5C X 35 sq mm Aluminium armoured cable (Panel to DB) Cable : Polycab/Avocab/Havells/ALLCAB. 80.00 R.MT 4.0.0 Fixtures & Fittings:- Supply, Installation, testing and commissioning of the following luminaries, fixtures and fittings. The fixtures shall be installed on wall, false ceiling etc. and as per the manufacturer instructions. The job also includes the connection of the fixture with outlet point using 3 core flexible wire wherever the lighting fixtures are there. (Earthing of Light Fixture is must). 4.1.0 1 x 36 W 2x2 LED Fitting optic reflector type tube light fitting. Make: CROMPTON / PHILIPS / BAJAJ / WIPRO. 10.00 Nos. 4.2.0 15 W LED Down light Make: VIN (LUMINA) / PHILIPS/ CROMPTON. 25.00 Nos. 4.3.0 Supply and installation 1 x 20 W LED T-5 Type Patti type : 4 Feet Make: CROMPTON / PHILIPS / BAJAJ / WIPRO. 5.00 Nos. 4.4.0 Supply and installation 1 x 9 W LED T-5 Type Patti type : 2 Feet Make: CROMPTON / PHILIPS / BAJA J/ WIPRO. 4.00 Nos. 4.5.0 Wall Fan 16 dia. Blade arrangement Make: CROMPTON /HAVELLS/BAJAJ/USHA. 6.00 Nos. 4.6.0 Supply and installation 44 Ceiling fan regulator Make: CROMPTON/HAVELLS/BAJAJ/USHA. 3.00 Nos. 4.7.0 12 Exhaust fan Make: CROMPTON /HAVELLS/ BAJAJ/USHA. 3.00 Nos. 5.0.0 Panel Board/Distribution Boards:- 5.3.0 Supplying and installing, testing and commissioning of TPN DB with following ; ( for lighting Purpose) Incoming : 40 A FP EL + MCB - 1no. Outgoing : 16/10/25 Amp. SP MCB - 5 nos. MCB & DB Make: L&T/HAVELLS/ABB/C&S 1.00 Nos. 5.4.0 Supplying, installing, testing & commission of TPN Distribution Board with following : ( for A. C. units) Outgoing : 40 A DP MCB - 4 nos MCB & DB Make: L&T/HAVELLS/ABB/C&S 1.00 Nos. 5.5.0 Supplying, installing, testing & commission of TPN distribution board with following : ( for UPS units) Incoming : 63 A FP DP MCB-1no. Outgoing : 10/16 A SP MCB - 6 nos MCB & DB Make: L&T/HAVELLS/ABB/C&S 1.00 Nos. 5.6.0 Supplying, installing, testing & commission of TPN distribution board with following : ( for UPS INPUT & OUTPUT) Incoming : 63 A FP DP MCB-1no. MCB & DB Make: L&T/HAVELLS/ABB/C&S 1.00 Nos. 5.7.0 SITC MAINTANCE FREE CHEMICAL EARTHING 1 MTR WITH BFC MATERIAL ALL CONNECTION COPPER WIRE INCLUDED FOR MAIN PANEL CONTINUTY FOR SUBSIDIERY PANEL ALSO 1.00 Nos 6.0.0 Intercom Telephone:- 6.1.0 Supply and laying of 2 pair telephone wire ISI marked PVC Insulated 0.63m sq mm. Copper conductor wire same as clause No. 1 of internal wiring from EPBEX to the various tables as per the requirement complete with RJ - 11 type Tel. Socket. all respect as per the drawing an Architect or consultant. Tel. Wire Make: RR Kabel/Polycab/Havells/Delton Tel. Socket Make : Crabtree/Legrand/ABB/Anchor 8.00 Nos. 6.2.0 Supply and laying of 10 pair telephone wire ISI marked PVC Insulated 0.63m sq mm. Copper conductor wire same as clause No. 1 of internal wiring from BSNL DP to 10 pair Krone Box as per the requirement complete including with 10 Pair Krone Box all respect as per the drawing an Architect or consultant. Tel. Wire Make: RR Kabel/Polycab/Havells/Delton 1.00 Nos. 7.0.0 Lan/Structure Cabling Work:- 7.1.0 Supply and laying of 4 PAIR UTP LAN cable - CAT-6 e in underground /wall in 1.5mm thick PVC pipe of 25mm dia with proper junction box for maintenance purpose from Rack/server room to each work station including supply and installation at CAT -6 e information outlet with fore plate and surface/concealed box. CAT 6 Data Cable & I/O Make: DIGILINK/D-LINK/AMP/MOLEX 20.00 Nos. 7.2.1 Supply & testing at patch cord (CAT 6e) Length 1 Meter (CAT 6e) original factory made (Connect with Patch Panel to Network Switch in Rack) CAT 6 Data Patch Cord Make: DIGILINK/D-LINK/AMP/MOLEX 20.00 Nos. 7.2.2 Length 2 Meter (CAT 6e) original factory made (Connect with I/O Point to Computer Networking Jack) CAT 6 Data Patch Cord Make: DIGILINK/DLINK/AMP/MOLEX 20.00 Nos. 7.3.0 Testing and connection of patch panel/ switch/ router and modem etc. 1.00 JOB 1.0.0 SPLIT INVERTER AIR CONDITIONERS Air cooled Type Complete with the following components as detailed in the section AIR COOLED SPLIT AIR CONDITIONERS. 1.5 TR Supply (5 Star) 2.00 Nos. 2.0.0 Removing and Reinstallation charges for existing High wall mounted split A/C at new location including connection servicing & gas filling complete as directed.[if required new copper piping and drain shall be paid as per item No [4 & 8] Shifting Existing Premises including indoor and outdoor with MS stand etc complete as directed. 1.0 / 1.5 TR Hi wall split AC 2.00 Nos. 3.0.0 INSTALLATION, TESTING & COMMISSIONING FOR CARRIER HI-WALL SPLIT TYPE AIR CONDITIONERS.(INCLUDING TOPPING OF GAS FOR AC GAS R-22/R410 ) 1.0 / 1.5 TR Hi wall split AC 7.00 Nos. 4.0.0 COPPER PIPING 1/4 + 1/2 Refrigerant piping 70.00 RMT 4.0.0 ELECTRICAL CABLING Electrical cable 3C/1.5sqmm 70.00 RMT 3.0.0 M.S.ANGLE STANDS FOR OUTDOOR UNITS 1.0 / 1.5 TR Hi wall split AC 2.00 Nos. 4.0.0 Rigid PVC Drain Piping 25 mm 70.00 MTR 3.0.0 Trenching / Civil Work 1.00 JOB

Key Value

Document Fees
INR 500 /-
Tender Value
Refer document

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail