Re Commissioning And Restoration Of The Fire Detection And Alarm System Affected By Civil Repair Works In Various Wards, Corridors And Rooms Of The Five-Storied Gynae And Obstetrics Building Within Cnmc And Hospital Complex, Kolkata
Tender Overview
Project Description
Re commissioning and Restoration of the fire detection and alarm system affected by civil repair works in various wards, corridors and rooms of the five-storied Gynae and Obstetrics building within CNMC and Hospital complex, Kolkata
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 16-Sep-2025 | Date Corrigendum | Date | 20-Sep-2025 |
BOQ
| Sl. No. | Item Description |
| 1 | S & L of 2 Core 1.5 sq.mm FRLS copper Cable(Make. Finolex /Polycab /RR Keble /KEI). |
| 2 | Supply & Laying of 20 mm NB PVC rigid conduit pipe on the surface of the wall by shaddeling as per PWD work. (Make: Precisson-Medium/ Ploycab-Medium) . |
| 3 | Re-fixing, and re-commissioning of essential field devices, including detectors/MCPs,/ Hooter cum Strobe units, along with all necessary accessories. These components are part of the VDS & FM approved Siemens fire alarm system installed at CNMC&H. |
| 4 | Cleaning,Checking, testing, and re-commissioning of essential field devices, includingdetectors,Manual Call Points (MCP), andHooter cum Strobe units. These devices are part of the VDS & FM approved Siemens fire alarm system installed at the National Medical College & Hospital in Kolkata. |
| 5 | SITC of Addressable Manual Call Point (VDS/UL/FM/ULC approved) addresable type with in-built fault isolator (Note: Detectors without built-in fault isolator is also acceptable but in such case the contractor shall provide one independent fault isolator module for every group of addressable devices in group will be as per latest recommended standard without any additional cost) as per NFPA style 7 wiring completed as required. [Make: Siemens/Ravel] |
| 6 | SITC of AddressableHooter (sound output minimum 90dB) cum strobe (strength of light 10cd) complete with necessary modules if required withinbuilt isolator(Note: Devices without built-in fault isolator is also acceptable but in such case the contractor shall provide one independent fault isolator module for every group of addressable devices in group will be as per latest recommended standard without any additional cost) &and (VDS/UL/FM/ULC approved) and approved. [Make: Siemens/Ravel] |
| 7 | SITC of VDS & FM approved make- Ravel/ Siemens Multi-sensor Detectors with base and all necessary accessories.[New] |
| 8 | Checking, Rectification, Testing and Re-commissioning of existing installed make- Ravel/ Siemens - Siemens/4 or 2 Loop Fire alarm Panel Installed at CNMC&H. |
| 9 | Add: GST @18% on total amount ofabove item (i.e. from item Sl. No. 1.00 to 28.00) as applicable |
| 10 | Add: LWC @1% on total amount ofabove item (i.e. from item Sl. No. 1.00 to 29.00) as applicable |
| 11 | Note: 1) Quoted Rates are inclusive of the all taxes, duties & cess as applicable with cost of maintenance, servicing,supply & replacement of spares for 1 (One) year from the date of commissioning.2) Total is rounded off to the nearest rupee and inclusive of all taxes, duties & cess as applicable. |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender