Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 01-10-2025 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 08-10-2025 |
| 2 | 22-09-2025 | Corrigendum No. 02 | Date | 01-10-2025 |
| 3 | 22-09-2025 | Corrigendum No. 01 | BOQ | 01-10-2025 |
| Sl. No. | Item Description |
| 1 | Taking down carefully copper/aluminium point wiring (light fan, socket or power) complete including fittings such as switches, sockets, c/roses, lamp holders, tube light fittings, sketch fittings, wooden boards, bell push, call bell, MCBs & regulators etc & making good to disturbed surfaces & matching with the existing colour of wall/floor etc complete all as specified and directed. |
| 2 | Material and labour for surface point wiring for one light point or fan point controlled by one switch with 1.5 Sqmm PVC insulated FRLSH, unsheathed, copper conductor stranded 1100 volt grade cable in & incl PVC Casing -n-caping /conduit of size not less than 20mm ISI marked ivory white with all accessories such as tee, bend, joint cover including anodized MS sunken boxes made out of MS sheet of thickness not less than 1.6 mm with earth dolly and PVC laminated hylem/Anchor ISI marked top cover 3.0 mm thick for mounting of switches/sockets/ regulator etc and PVC insulated & unsheathed 1100 volt grade copper conductor, stranded 1.5 sqmm cable as continuous earth lead complete all as specified and colour coding of cables such as Phase -Red, Neutral – Black, and Earth – Green all as directed by Engr-in-charge .Note: cutting of walls (brick or stone), making good disturbed surface of wall in CM 1:3 and painting with existing colour & specifications is deemed to include in the quoted rate. |
| 3 | Material and labour for surface point wiring for one Call Bell point controlled by one push button switch with 1.5 Sqmm PVC insulated FRLSH, unsheathed, copper conductor stranded 1100 volt grade cable in & incl PVC Casing -n-caping /conduit of size not less than 20mm ISI marked ivory white with all accessories such as tee, bend, joint cover including anodized MS sunken boxes made out of MS sheet of thickness not less than 1.6 mm with earth dolly and PVC laminated hylem/Anchor ISI marked top cover 3.0 mm thick for mounting of switches/sockets/ regulator etc and PVC insulated & unsheathed 1100 volt grade copper conductor, stranded 1.5 sqmm cable as continuous earth lead complete all as specified and colour coding of cables such as Phase -Red, Neutral – Black, and Earth – Green all as directed by Engr-in-charge .Note: cutting of walls (brick or stone), making good disturbed surface of wall in CM 1:3 and painting with existing colour & specifications is deemed to include in the quoted rate. |
| 4 | Material and labour for surface point wiring for 5Amp independent socket point controlled by one switch with 1.5 Sqmm PVC insulated FRLSH, unsheathed, copper conductor stranded 1100 volt grade cable in & incl PVC Casing -n-caping /conduit of size not less than 20mm ISI marked ivory white with all accessories such as tee, bend, joint cover including anodized MS sunken boxes made out of MS sheet of thickness not less than 1.6 mm with earth dolly and PVC laminated hylem/Anchor ISI marked top cover 3.0 mm thick for mounting of switches/sockets/ regulator etc and PVC insulated & unsheathed 1100 volt grade copper conductor, stranded 1.5 sqmm cable as continuous earth lead complete all as specified and colour coding of cables such as Phase -Red, Neutral – Black, and Earth – Green all as directed by Engr-in-charge .Note: cutting of walls (brick or stone), making good disturbed surface of wall in CM 1:3 and painting with existing colour & specifications is deemed to include in the quoted rate. |
| 5 | Material and labour for surface point wiring for one 3 pin ,5 Amp socket point with other switch on the same board with 1.5 Sqmm PVC-FRLSH insulated, unsheathed, copper conductor, stranded 1100 volt grade cable and PVC insulated & unsheathed 1100 volt grade copper conductor, stranded 1.5 sqmm. cable as continuous earth lead complete all as specified and colour coding of cables such as Phase -Red, Neutral – Black, and Earth – Green all as directed by Engr-in-charge .Note: cutting of walls (brick or stone), making good disturbed surface of wall in CM 1:3 and painting with existing colour & specifications is deemed to include in the quoted rate. |
| 6 | Material and labour for surface power point wiring with 2.5 Sqmm PVC insulated FRLSH, unsheathed, copper conductor stranded 1100 volt grade cable in & incl PVC Casing -n-caping /conduit of size not less than 20mm ISI marked ivory white with all accessories such as tee, bend, joint cover including anodized MS sunken boxes made out of MS sheet of thickness not less than 1.6 mm with earth dolly and PVC laminated hylem/Anchor ISI marked top cover 3.0 mm thick for mounting of switches/sockets/ regulator etc and PVC insulated & unsheathed 1100 volt grade copper conductor, stranded 2.5 sqmm cable as continuous earth lead complete all as specified and colour coding of cables such as Phase -Red, Neutral – Black, and Earth – Green all as directed by Engr-in-charge .Note: cutting of walls (brick or stone), making good disturbed surface of wall in CM 1:3 and painting with existing colour & specifications is deemed to include in the quoted rate. |
| 7 | Material and labour for concealed point wiring for one light point or fan point controlled by one switch with 1.5 Sqmm PVC insulated FRLSH, unsheathed, copper conductor stranded 1100 volt grade cable in & incl PVC conduit of size not less than 20mm ISI marked ivory white with all accessories such as tee, bend, joint cover including anodized MS sunken boxes made out of MS sheet of thickness not less than 1.6 mm with earth dolly and PVC laminated hylem/Anchor ISI marked top cover 3.0 mm thick for mounting of switches/sockets/ regulator etc and PVC insulated & unsheathed 1100 volt grade copper conductor, stranded 1.5 sqmm cable as continuous earth lead complete all as specified and colour coding of cables such as Phase -Red, Neutral – Black, and Earth – Green all as directed by Engr-in-charge .Note: cutting of walls (brick or stone), making good disturbed surface of wall in CM 1:3 and painting with existing colour & specifications is deemed to include in the quoted rate. |
| 8 | Material and labour for concealed point wiring for one Call Bell point controlled by one push button switch with 1.5 Sqmm PVC insulated FRLSH, unsheathed, copper conductor stranded 1100 volt grade cable in & incl PVC conduit of size not less than 20mm ISI marked ivory white with all accessories such as tee, bend, joint cover including anodized MS sunken boxes made out of MS sheet of thickness not less than 1.6 mm with earth dolly and PVC laminated hylem/Anchor ISI marked top cover 3.0 mm thick for mounting of switches/sockets/ regulator etc and PVC insulated & unsheathed 1100 volt grade copper conductor, stranded 1.5 sqmm cable as continuous earth lead complete all as specified and colour coding of cables such as Phase -Red, Neutral – Black, and Earth – Green all as directed by Engr-in-charge .Note: cutting of walls (brick or stone), making good disturbed surface of wall in CM 1:3 and painting with existing colour & specifications is deemed to include in the quoted rate. |
| 9 | Material and labour for concealed point wiring for 5Amp independent socket point controlled by one switch with 1.5 Sqmm PVC insulated FRLSH, unsheathed, copper conductor stranded 1100 volt grade cable in & incl PVC conduit of size not less than 20mm ISI marked ivory white with all accessories such as tee, bend, joint cover including anodized MS sunken boxes made out of MS sheet of thickness not less than 1.6 mm with earth dolly and PVC laminated hylem/Anchor ISI marked top cover 3.0 mm thick for mounting of switches/sockets/ regulator etc and PVC insulated & unsheathed 1100 volt grade copper conductor, stranded 1.5 sqmm cable as continuous earth lead complete all as specified and colour coding of cables such as Phase -Red, Neutral – Black, and Earth – Green all as directed by Engr-in-charge .Note: cutting of walls (brick or stone), making good disturbed surface of wall in CM 1:3 and painting with existing colour & specifications is deemed to include in the quoted rate. |
| 10 | Material and labour for concealed point wiring for one 3 pin ,5 Amp socket point with other switch on the same board with 1.5 Sqmm PVC-FRLSH insulated, unsheathed, copper conductor, stranded 1100 volt grade cable and PVC insulated & unsheathed 1100 volt grade copper conductor, stranded 1.5 sqmm. cable as continuous earth lead complete all as specified and colour coding of cables such as Phase -Red, Neutral – Black, and Earth – Green all as directed by Engr-in-charge .Note: cutting of walls (brick or stone), making good disturbed surface of wall in CM 1:3 and painting with existing colour & specifications is deemed to include in the quoted rate. |
| 11 | Material and labour for concealed power point wiring with 2.5 Sqmm PVC insulated FRLSH, unsheathed, copper conductor stranded 1100 volt grade cable in & incl PVC conduit of size not less than 20mm ISI marked ivory white with all accessories such as tee, bend, joint cover including anodized MS sunken boxes made out of MS sheet of thickness not less than 1.6 mm with earth dolly and PVC laminated hylem/Anchor ISI marked top cover 3.0 mm thick for mounting of switches/sockets/ regulator etc and PVC insulated & unsheathed 1100 volt grade copper conductor, stranded 2.5 sqmm cable as continuous earth lead complete all as specified and colour coding of cables such as Phase -Red, Neutral – Black, and Earth – Green all as directed by Engr-in-charge .Note: cutting of walls (brick or stone), making good disturbed surface of wall in CM 1:3 and painting with existing colour & specifications is deemed to include in the quoted rate. |
| 12 | Material and labour for concealed point wiring for one light or fanpoint controlled by one switch with 1.5 Sqmm PVC-FRLSH insulated, unsheathed, copper conductor, stranded 1100 volt grade cable in & incl PVC conduit,includingmodular metal flush boxes & modular white cover plate of suitable module with frame as per site requirement all fittings such as tees, bends, elbows,etc. of External diameter 20mmall as per site requirements PVC insulated & unsheathed 1100 volt grade copper conductor, stranded 1.5 sqmm cable as continuous earth lead complete all as specified and colour coding of cables such as Phase -Red, Neutral – Black, and Earth – Green all as directed by Engr-in-charge .Note: cutting of walls (brick or stone), making good disturbed surface of wall in CM 1:3 and painting with existing colour & specifications is deemed to include in the quoted rate. |
| 13 | Material and labour for concealed point wiring for onecall bell point controlled by one push button switch with 1.5 Sqmm PVC-FRLSH insulated, unsheathed, copper conductor, stranded 1100 volt grade cable in & incl PVC conduit,includingmodular metal flush boxes & modular white cover plate of suitable module with frame as per site requirement all fittings such as tees, bends, elbows,etc. of External diameter 20mmall as per site requirements PVC insulated & unsheathed 1100 volt grade copper conductor, stranded 1.5 sqmm. cable as continuous earth lead complete all as specified and colour coding of cables such as Phase -Red, Neutral – Black, and Earth – Green all as directed by Engr-in-charge .Note: cutting of walls (brick or stone), making good disturbed surface of wall in CM 1:3 and painting with existing colour & specifications is deemed to include in the quoted rate. |
| 14 | Material and labour for concealed point wiring for one5 Amp independent socket point controlled by one switchwith 1.5 Sqmm PVC-FRLSH insulated, unsheathed, copper conductor, stranded 1100 volt grade cable in & incl PVC conduit,includingmodular metal flush boxes & modular white cover plate of suitable module with frame as per site requirement all fittings such as tees, bends, elbows,etc. of External diameter 20mmall as per site requirements PVC insulated & unsheathed 1100 volt grade copper conductor, stranded 1.5 sqmm. cable as continuous earth lead complete all as specified and colour coding of cables such as Phase -Red, Neutral – Black, and Earth – Green all as directed by Engr-in-charge .Note: cutting of walls (brick or stone), making good disturbed surface of wall in CM 1:3 and painting with existing colour & specifications is deemed to include in the quoted rate. |
| 15 | Material and labour for concealed point wiring for one 3 pin ,5 Amp socket point with other switch on the same board with 1.5 Sqmm PVC-FRLSH insulated, unsheathed, copper conductor, stranded 1100 volt grade cable and PVC insulated & unsheathed 1100 volt grade copper conductor, stranded 1.5 sqmm. cable as continuous earth lead complete all as specified and colour coding of cables such as Phase -Red, Neutral – Black, and Earth – Green all as directed by Engr-in-charge .Note: cutting of walls (brick or stone), making good disturbed surface of wall in CM 1:3 and painting with existing colour & specifications is deemed to include in the quoted rate. |
| 16 | Material and labour for concealed point wiring for one light point controlled by two wayswitch with 1.5 Sqmm PVC-FRLSH insulated, unsheathed, copper conductor, stranded 1100 volt grade cable in & incl PVC conduit,includingmodular metal flush boxes & modular white cover plate of suitable module with frame as per site requirement all fittings such as tees, bends, elbows,etc. of External diameter 20mmall as per site requirements PVC insulated & unsheathed 1100 volt grade copper conductor, stranded 1.5 sqmm cable as continuous earth lead complete all as specified and colour coding of cables such as Phase -Red, Neutral – Black, and Earth – Green all as directed by Engr-in-charge .Note: cutting of walls (brick or stone), making good disturbed surface of wall in CM 1:3 and painting with existing colour & specifications is deemed to include in the quoted rate. |
| 17 | Material and labour for concealed power point wiring with 2.5 Sqmm PVC-FRLSH insulated, unsheathed, copper conductor, stranded 1100 volt grade cable in & incl PVC conduit,includingmodular metal flush boxes & modular white cover plate of suitable module with frame as per site requirement all fittings such as tees, bends, elbows,etc.of External diameter 20mm all as per site requirements PVC insulated & unsheathed 1100 volt grade copper conductor, stranded 2.5 sqmm. cable as continuous earth lead complete all as specified and colour coding of cables such as Phase -Red, Neutral – Black, and Earth – Green complete all as specified and as directed.Note: cutting of walls (brick or stone), making good disturbed surface of wall in CM 1:3 and painting with existing colour & specifications is deemed to include in the quoted rate. |
| 18 | Supply and fixing Modular switch, one way, 6 Amp 230 volts, 1 module complete all as specified and directed . |
| 19 | Supply and fixing Modular switch, 02 way, 6 Amp 230 volts, 1 module complete all as specified and directed . |
| 20 | Supply and fixing socket Modular 6 Amp-2/3 pin combined 2 module complete all as specified and directed . |
| 21 | Supply and fixing switch Modular, single pole, one way,16 Amp ,1 module 230 Volt complete all as specified and directed . |
| 22 | Supply and fixing socket modular 6/16 Amp, 2/3 pin combined ,2 module 230 Volt complete all as specified and directed . |
| 23 | Supply and fixing modular fan step regulator 60-80W2 module complete all as specified and directed. |
| 24 | Supply and fixing modular bell push 6A ,1 module complete all as specified and directed. |
| 25 | Supply and fixing switch piano type flush, single pole, one way 5 A 230 V complete all as specified and directed. |
| 26 | Supply and fixing socket outlet, 5 pin, 5 Amp, flush type, 230 V complete all as specified and directed. |
| 27 | Supply and fixing switch piano type flush, single pole, one way 15 A 230 V complete all as specified and directed. |
| 28 | Supply and fixingsocket outlet2 in 1,6 pin, 5/15 A, flush piano type240 V complete all as specified and directed. |
| 29 | Supply and fixing ceiling rose, surface backlite,three terminal complete all as specified and directed. |
| 30 | Supply and fixing lamp holder insulated with back plate suitable for Angle/Batten fitting complete all as specified and directed. |
| 31 | Supply and fixing bell ding dong 230 V, single phase complete all as specified and directed. |
| 32 | Supply and fixing electronic double space rotary 5 speed type regulator 120-280 V complete all as specified and directed. |
| 33 | Supply and fixing bell push flush type one way 5Amp 240 Volt complete all as specified and directed. |
| 34 | Material and labour for concealed sub main wiring with two single core PVC FRLSH insulated unsheathed stranded copper conductor cable FRLS, 02 runs of 01 Single core of size6 sqmm (for main current) drawn in & incl PVC conduitless than 20mm dia ISI markedwith all accessories such as tee, bend, joint cover etc round / square blocks at junctions etc, all as per site requirements ISI marked with one run of01 Single core of size 6 Sqmm (As earth wire) PVC insulated unsheathed stranded copper conductor as a continuous earth wireand colour coding of cables such as Phase - Red, Neutral – Black, and Earth – Green etc complete, including taking down old unserviceable sub main wiring withPVC conduit complete all as specified and as directed.Note: (i) cutting of walls (brick or stone), making good disturbed surface of wall in CM 1:3 and painting with existing colour & specifications is deemed to include in the quoted rate.(ii)Two runs of single core of size 6.00 sqmm for main current and one run of single core of size6.00 sqmm for earth continuity conductor & one run of PVC conduit shall be measured as one unit length. |
| 35 | Material and labour for surface conduitsub main wiring with two single core PVC FRLSH insulated unsheathed stranded copper conductor cable FRLS, 02 runs of 01 Single core of size6 sqmm (for main current) drawn in & incl PVC casing -n-caping/pvc conduit of suitable size . ISI markedwith all accessories such as tee, bend, joint cover etc round / square blocks at junctions etc, all as per site requirements ISI marked with one run of01 Single core of size 6 Sqmm (As earth wire) PVC insulated unsheathed stranded copper conductor as a continuous earth wireand colour coding of cables such as Phase - Red, Neutral – Black, and Earth – Green etc complete, including taking down old unserviceable sub main wiring with casing-caping/conduit complete all as specified and as directed.Note: (i) cutting of walls (brick or stone), making good disturbed surface of wall in CM 1:3 and painting with existing colour & specifications is deemed to include in the quoted rate.(ii)Two runs of single core of size 6.00 sqmm for main current and one run of single core of size6.00 sqmm for earth continuity conductor & one run of PVC casing-caping/conduit shall be measured as one unit length. |
| 36 | Material and labour for surface conduitsub main wiring with two single core PVC FRLSH insulated unsheathed stranded copper conductor cable FRLS, 02 runs of 01 Single core of size10 sqmm (for main current) drawn in & incl PVC casing -n-caping/pvc conduit of suitable size . ISI markedwith all accessories such as tee, bend, joint cover etc round / square blocks at junctions etc, all as per site requirements ISI marked with one run of01 Single core of size 10 Sqmm (As earth wire) PVC insulated unsheathed stranded copper conductor as a continuous earth wireand colour coding of cables such as Phase - Red, Neutral – Black, and Earth – Green etc complete, including taking down old unserviceable sub main wiring with casing-caping/conduit complete all as specified and as directed.Note: (i) cutting of walls (brick or stone), making good disturbed surface of wall in CM 1:3 and painting with existing colour & specifications is deemed to include in the quoted rate.(ii)Two runs of single core of size 10.00 sqmm for main current and one run of single core of size10.00 sqmm for earth continuity conductor & one run of PVC casing-caping/conduit shall be measured as one unit length. |
| 37 | Material and labour for surface conduitsub main wiring with two single core PVC FRLSH insulated unsheathed stranded copper conductor cable FRLS, 02 runs of 01 Single core of size4 sqmm (for main current) drawn in & incl PVC casing -n-caping/pvc conduit of suitable size . ISI markedwith all accessories such as tee, bend, joint cover etc round / square blocks at junctions etc, all as per site requirements ISI marked with one run of01 Single core of size 4 Sqmm (As earth wire) PVC insulated unsheathed stranded copper conductor as a continuous earth wireand colour coding of cables such as Phase - Red, Neutral – Black, and Earth – Green etc complete, including taking down old unserviceable sub main wiring with casing-caping/conduit complete all as specified and as directed.Note: (i) cutting of walls (brick or stone), making good disturbed surface of wall in CM 1:3 and painting with existing colour & specifications is deemed to include in the quoted rate.(ii)Two runs of single core of size 4.00 sqmm for main current and one run of single core of size4.00 sqmm for earth continuity conductor & one run of PVC casing-caping/conduit shall be measured as one unit length. |
| 38 | Material and labour for surface conduitsub main wiring with two single core PVC FRLSH insulated unsheathed stranded copper conductor cable FRLS, 02 runs of 01 Single core of size2.50 sqmm (for main current) drawn in & incl PVC casing -n-caping/pvc conduit of suitable size . ISI markedwith all accessories such as tee, bend, joint cover etc round / square blocks at junctions etc, all as per site requirements ISI marked with one run of01 Single core of size 2.50 Sqmm (As earth wire) PVC insulated unsheathed stranded copper conductor as a continuous earth wireand colour coding of cables such as Phase - Red, Neutral – Black, and Earth – Green etc complete, including taking down old unserviceable sub main wiring with casing-caping/conduit complete all as specified and as directed.Note: (i) cutting of walls (brick or stone), making good disturbed surface of wall in CM 1:3 and painting with existing colour & specifications is deemed to include in the quoted rate.(ii)Two runs of single core of size 2.50 sqmm for main current and one run of single core of size2.50 sqmm for earth continuity conductor & one run of PVC casing-caping/conduit shall be measured as one unit length. |
| 39 | Material and labour for surface conduitsub main wiring with two single core PVC FRLSH insulated unsheathed stranded copper conductor cable FRLS, 02 runs of 01 Single core of size1.50 sqmm (for main current) drawn in & incl PVC casing -n-caping/pvc conduit of suitable size . ISI markedwith all accessories such as tee, bend, joint cover etc round / square blocks at junctions etc, all as per site requirements ISI marked with one run of01 Single core of size 1.50 Sqmm (As earth wire) PVC insulated unsheathed stranded copper conductor as a continuous earth wireand colour coding of cables such as Phase - Red, Neutral – Black, and Earth – Green etc complete, including taking down old unserviceable sub main wiring with casing-caping/conduit complete all as specified and as directed.Note: (i) cutting of walls (brick or stone), making good disturbed surface of wall in CM 1:3 and painting with existing colour & specifications is deemed to include in the quoted rate.(ii)Two runs of single core of size 1.50 sqmm for main current and one run of single core of size1.50 sqmm for earth continuity conductor & one run of PVC casing-caping/conduit shall be measured as one unit length. |
| 40 | Supply and fixing testing and commissioning of MCB SP 240 volt 6 Amp to 40 Amp 10 KA capacity having C-curve characteristics connected with suitable lugs etc complete, including taking down existing MCB complete all as specified and directed. |
| 41 | Supply and fixing testing and commissioning of MCB SPN 240 volt 16 Amp to 40 Amp 10 KA capacity having C-curve characteristics connected with suitable lugs etc complete, including taking down existing MCB complete all as specified and directed. |
| 42 | Supply and fixing testing and commissioning of MCB SPN 240 volt63Amp 10 KA capacity having C-curve characteristics connected with suitable lugs etc complete, including taking down existing MCB complete all as specified and directed. |
| 43 | Supply and fixing testing and commissioning of MCB SP 240 volt63Amp 10 KA capacity having C-curve characteristics connected with suitable lugs etc complete, including taking down existing MCB complete all as specified and directed. |
| 44 | Supply and fixing double door metallic sheet metal enclosure for MCB DBdouble doorTPN 4 Way 415 Volts with 100-160 Amps rated bus bars etc complete, including taking down existing DB complete all as specified and directed.Note: cutting of walls (brick or stone), making good disturbed surface of wall in CM 1:3 and painting with existing colour & specifications is deemed to include in the quoted rate. |
| 45 | Supply and fixing testing and commissioning of MCB TPN 63 Amps415 Vincluding making electrical coming/outgoing connections with lugs/thimbles etc complete, including taking down existing MCB complete all as specified and directed. |
| 46 | Supply and fixing sheet metal enclosureDB double door, IP-43 when MCBs to be used SPN, 12 way, 240 V with 100-160 Amps rated bus bar of suitable size etc complete, including taking down existing DB complete all as specified and directed.Note: cutting of walls (brick or stone), making good disturbed surface of wall in CM 1:3 and painting with existing colour & specifications is deemed to include in the quoted rate. |
| 47 | Supply and fixing sheet metal enclosureDB double door, IP-43 when MCBs to be used SPN, 8 way, 240 V with 100-160 Amps rated bus bar of suitable size etc complete, including taking down existing DB complete all as specified and directed.Note: cutting of walls (brick or stone), making good disturbed surface of wall in CM 1:3 and painting with existing colour & specifications is deemed to include in the quoted rate. |
| 48 | Supply and fixing sheet metal enclosureDB double door, IP-43 when MCBs to be used SPN, 4 way, 240 V with 100-160 Amps rated bus bar of suitable size etc complete, including taking down existing DB complete all as specified and directed.Note: cutting of walls (brick or stone), making good disturbed surface of wall in CM 1:3 and painting with existing colour & specifications is deemed to include in the quoted rate. |
| 49 | Supply and fixing sheet metal enclosureDB single door, IP-43 when MCBs to be used SPN, 2 way, 240 V with 100-160 Amps rated bus bar of suitable size etc complete, including taking down existing DB complete all as specified and directed.Note: cutting of walls (brick or stone), making good disturbed surface of wall in CM 1:3 and painting with existing colour & specifications is deemed to include in the quoted rate. |
| 50 | Supply and fixing2 X 2 ultra slip recess mountedluminaire with high brightness 36 Watt LED packageand Unique pattern acrylic de-glaring diffuser sheet for glare-free uniform light distribution suitable forarmstrong/grid ceiling etc complete, including taking out existing ceiling light complete all as specified and directed. |
| 51 | Supply and fixing LED Bulk head 13/10 watt designed for modern homes available in PIR as well as non PIR sensor with premium quality diffuser for glarefree light and easy to install snapfit installer complete all as specified and directed. |
| 52 | Supply and fixing TL fitting 20watt for surface and wall mounted LED batten with ultra slim polycarbonate LED lighting fixture with high lumen output environmental friendly energy efficient complete all as specified and directed. |
| 53 | Supply and fixing double door metallic sheet metal enclosure for DBdouble door(DPX-125 ) VTPN4 Way 415 Volts with 200 Amps rated bus bars IP 43- \"IK 09 etc complete, including taking down existing DB complete all as specified and directed.Note: cutting of walls (brick or stone), making good disturbed surface of wall in CM 1:3 and painting with existing colour & specifications is deemed to include in the quoted rate. |
| 54 | Supply and fixing testing and commissioning of MCCB 63 Amps 4 pole, 415 V 16 KA etc complete, including taking down existing MCCB complete all as specified and directed. |
| 55 | Supply and fixing testing and commissioning of MCCB 100 Amps 4 pole, 415 V 16 KA etc complete, including taking down existing MCCB complete all as specified and directed. |
| 56 | Supply and fixing box type LED optic fitting10/9 Watt2 feet box type complete all as specified and directed. |
| 57 | Taking out old earthing including connected accessories and M&L for earthingcomplete with using galvanized mild steel earth plate (electrode) 600 mmx 600 mmx 6 mm thick buried directly in ground, earth pit not less than 2.25 mtr deep below ground level with top edge of the earth plate not less than 1.50 m below ground level and earth plate surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all round the plateusing 4 mmdia GI earth wire as earth lead moulded and riveted to earthplate at one end and connected to main equipment at switch/control board at another end, GI earth leadincased in and including 50 mm dia GI ‘light grade’ pipe from upper end of earth plate upto equipment with & including 20 mm dia bore GI pipe ‘light grade’ as water pipe from earth chamber to upper edge of the earth plate,GI funnel with wire mesh fixed on water pipe and provision of PCC 1:2:4 type B1(using 20 mm graded stone agg) as in pits chamber and RCC pit cover 50 mmthick of precast RCC 1:2:4 type B-1 (using 20 mm graded stone agg)duly reinforced with mild steel round bars 6 mm dia @ 150 mmc/c both ways with 10 mm dia mild steel bars as in lifting handles with and including necessary excavation & earth work includinglaying the GI pipe concealed in floor /wall all as per plate No. 3 of SSR Part Iand testing on completion complete all as specified and directed and testing on completion.Note : (i) If the desired earth resistance is not found earthing shall be re-done by the Contractor at no extra cost to govt.(ii) The rate quoted shall also deemed to include the cost of GI pipe and protection pipe upto 7.5 Mtr beyond the earth plates electrode and also the costof the Test point. (iii) Joining of GI earth wire with pipe of the test point shall be done by using suitable cable lugs. |
| 58 | Supply, laying and testing of XLPE insulated armoured heavy duty electric cable with aluminium conductor ,1100 volts grade ,cross section area 10 Sqmm 2 core complete laid in trenches, ducts or fix to pipe, on walls, poles etc, including taking out existing cable complete all as specified and directed. |
| 59 | Supply and fixing metal clad box enclosure with socket plug top and MCB SP 20 Amps flush mounting enclosure with 2 pin and earth plug socket etc complete, including taking down existing metal clad box enclosure complete all as specified and directed.Note: cutting of walls (brick or stone), making good disturbed surface of wall in CM 1:3 and painting with existing colour & specifications is deemed to include in the quoted rate. |
| 60 | Supply and fixing Modular AC box enclosure with socket plug top and MCB SP 25 Amps, 10 KA capacity having C-curve flush mounting enclosure etc complete, including taking down existing AC Box complete all as specified and directed.Note: cutting of walls (brick or stone), making good disturbed surface of wall in CM 1:3 and painting with existing colour & specifications is deemed to include in the quoted rate. |
| 61 | Supply and laying/fixing PVC insulated and unsheathed single core multi stranded copper conductor 1.50 Sqmm (Nominal Area) drawn in existing conduit / batten / surfaceetc, including taking out existing pvc insulated copper conductor complete all as specified and directed. |
| 62 | Supply and laying/fixing PVC insulated and unsheathed single core multi stranded copper conductor 2.50 Sqmm (Nominal Area) drawn in existing conduit / batten / surfaceetc, including taking out existing pvc insulated copper conductor complete all as specified and directed. |
| 63 | Supply and laying/fixing PVC insulated and unsheathed single core multi stranded copper conductor 10.00 Sqmm (Nominal Area) drawn in existing conduit / batten / surfaceetc, including taking out existing pvc insulated copper conductor complete all as specified and directed. |
| 64 | Supply and laying/fixing PVC insulated and unsheathed single core multi stranded copper conductor 16.00 Sqmm (Nominal Area) drawn in existing conduit / batten / surfaceetc, including taking out existing pvc insulated copper conductor complete all as specified and directed. |
| 65 | Supply and fixing modular PVC board 3/4/6/8/12 module etc complete, including taking down existing PVC boardcomplete all as specified and directed. |
| 66 | Supply and fixing normal pvc board etc complete, including taking down existing PVC boardcomplete all as specified and directed. |
| 67 | Taking out old unserviceable laminated sheet and S & F new laminated super hylem sheet white colour 3mm thick of size 8\" x 5\" including fixing of switches, sockets as per existing pattern complete all as specified and directed. |
| 68 | Taking out old unserviceable laminated sheet and S & F new laminated super hylem sheet white colour 3mm thick of size 5\" x 5\" including fixing of switches, sockets as per existing pattern complete all as specified and directed. |
| 69 | Taking out old unserviceable laminated sheet and S & F new laminated super hylem sheet white colour 3mm thick of size 8\" x 10\" including fixing of switches, sockets as per existing pattern complete all as specified and directed. |
| 70 | Taking out old unserviceable laminated sheet and S & F new laminated super hylem sheet white colour 3mm thick of size 8\" x 12\" including fixing of switches, sockets as per existing pattern complete all as specified and directed. |
| 71 | Taking out old unserviceable laminated sheet and S & F new laminated super hylem sheet white colour 3mm thick of size 9\" x 11\" including fixing of switches, sockets as per existing pattern complete all as specified and directed. |
| 72 | Supply and fixing PVC conduit of size 20mm dia including fixing on wall/ceiling with suitable clamp/saddles for wiring wire all as required at site etc complete, including taking down existing PVC conduit complete all as specified and directed. |
| 73 | Supply and fixing PVC conduit of size 25/32mm dia including fixing on wall/ceiling with suitable clamp/saddles for wiring wire all as required at site etc complete, including taking down existing PVC conduit complete all as specified and directed. |
| 74 | Supply and fixing PVC casing caping of size 1\" x 1/2\" including fixing on wall/ceiling with clamp/saddles for wiring wire all as required at site etc complete, including taking down existing PVC casing-caping complete all as specified and directed. |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy