supply installation testing and commissioning of Passenger Lift with allied EI works for G+3 Female Ward of Calcutta Pavlov Hospital, 18, Gobra Road, Kolkata-700046 - Allied EI Works- 1 Supply & Laying of following size PVC Armoured Al. cable, through underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed as to G.S. 2 a) 4 core 35 sq.mm.PVC Ar./Al. Cable. 3 Supplying & fixing 50mm dia medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as to GS 4 Supply & Fixing of compression type cable gland of the following sizes PVC/ Al cable with end finishing by Dowels solder less socket by crimping method as to G.S. 5 a) 4 core 35 sq.mm.PVC Ar./Al. Cable. 6 S&F 4 way Vertical TPNDB with MCCB incoming & TP/SP outgoings, as follows with vertical type busbar system, in SS enclosure (IP-43) double door comprising of neutral link incl. & provision for earthing attachment, concealed in wall incl. interconnection with suitable size of copper wires and earthing attachment, with cable entry Box at both ends, as per GS.Incoming - 415V 25KA 80A FPMCCB (1 no) Outgoing - 10KA 32A TPMCB - (2 no), 10KA 32A SPMCB - (6 no) [Make : Legrand/ LK/ ABB] 7 Supplying and fixing 250 V, 6-16A per way, 2+8 way SPN MCBDB with SS enclosure double-door with IP-42/43 protection with 40Amp DP Isolator as incomer and SPMCBs 6 to 16A (C Curve, 10kA)-8 nos as outgoing, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. (Make- Legrand/ ABB/ LK). 8 Supply & Fixing of 415V. Earth leakage protection Four pole- Sensitivity 300mA 40 amp DX3 RCCBs (Legrand Cat No. 411892 ) in Independent mounting 4 way Metal Encloser (Legrand Cat. No. 607884) concealed/surfaceon wall & mending goods the damages as par direction of E.I.C 9 Supplying and fixing 20A DP MCB with MCB SS enclosure with IP-20/30 protection, powder coated provision for two pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment as to GS.(Make - LK/ Legrand/ ABB). 10 Supply & Fixing 240V 6/20A multi plug socket with 20A piano key type Switch (Anchor make) on sheet metal box incl.S&F 150 x 100 x 65 mm. MS (16 SWG) switch Board and Bakelite top cover on wall as per direction of EIC. 11 Supply & FixingDie cast housingwith unbreakable polycarbonate diffuser wall mounting LED bulkhead with IP-66 protection by nuts & bolts incl. necessary connections as required (Make- Philips cat no. WT202W LED6S NW PSU S2 PC) 12 Supply & Fixing 240 V, 20 A Piano key type switch (Brand approved by EIC) on sheet metal switch board incl. S & F 100x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required.(For controling Light at Lift well) 13 Supply & Fixing 240 V, 6 A Piano key type switch (Brand approved by EIC) on sheet metal switch board incl. S & F 100x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required. (For controling 2 Nos. Light at Lift pit) 14 Supply & laying of 1.1KV single core stranded FR PVC insulated & unsheathed copper wire in 20/25mm dia rigid PVC conduit pipe(precision) by shaddling on wall as per instruction of E.I.C. 15 a) 4x10sqmm + 2x6sqmm 16 b) 2x6sqmm + 1x4sqmm 17 c) 2x4sqmm + 1x2.5sqmm [for Power plug ] 18 d) 3x1.5sqmm 19 Finising the end of the following cu wire 20 a) 4x10sqmm + 2x6sqmm 21 b) 2x6sqmm + 1x4sqmm 22 c) 2x4sqmm + 1x2.5sqmm [for Power plug ] 23 Cutting Spl. Type Hole by Hevy duty Electric operated drill machine in concreate slab/ marbel 12’’ thick incl. the 8mm /12mm TMT rod cutting by welding machine for smoothly passing rigid conduit for connection switch board & SPNDB incl. mending the damages as par direction of E.I.C 24 Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded FR PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit FR (Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded FR PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall complete with 2 no. suitable size “Ph & N” copper bar incl. bakelite/Perspex (wall matching color) top cover 3 mm thick and incl. 175mmx100mmx65mm inspection box, making earthing attachment, painting the MS box and mending good the damages to original finish 25 a) Average run 8 mtr 26 b) On Board 27 S&Fixing 4ft. long Double LED tube light fittings complete with all accessories (Philips make Cat No.TMC 501P 2xT-LED 22W P3242) incl. S&F 2Nos. 20W LED tube (Master LEDtube 1200mm 18W865 T8 I-2100Lm) complete with all accessories directly on wall/ceiling/HW round block and suitable size of MS fastener.as per GS. 28 S&F 16 inch dia wall mounted all metal body fan (EPC) on wall by S&F rag bolts, nuts & washers (6 mm dia x 62 mm long) or as reqd. incl. S&F 24/0.20 PVC insulated flexible copper wire 0.5 mt. length as directed by EIC 29 Supply and Fixing of 12 inch (30cm) dia exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection with Supply & Fixing GI sheet (20SWG) metal Cowl with MS flat iron frame & GI wire mesh on wall with necy. bolts & nuts (6 mm dia x 62 mm long) 30 Supply & fixing Analog Timer Control Unit for single phase Exhaust Fan assembled with the MS Enclosure dulyphosphatised powder coatedwith din rail with IP-53 protection fixed on wall with front door locking arrangement and all necessary wiring and making connection as per direction of EIC. (Legrand- MaxiRex 4QTB daily with IP 53 box) 31 Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level & restoring surface duly rammed as below (ISI-M G.I pipe). 32 Excavation of soil for installation of earth electrode and filling & ramming (For soft soil) 33 Withdrawing the paver blocks and cutting the concrete pathway for errection of the2 Nos. earthing and mending good the damages to original finish as directed by EIC. 34 Extra for providing masonary enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep complete with cemented brick work of 25 cm width duly plastered with cement morter CI hinged inspection cover of size 35.56 x35.56 cm with locking arrangement GI reducer incl. drilling holes on the GI pipe. 35 Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 40 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required as to GS. 36 Connecting the equipments to earth busbar S & F 25 mm x 6 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc. as to G.S. 37 Connecting the equipments to earth busbar including S & F 4 SWG GI (Hot Dip) wire on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages as to GS 38 Hiring charges for scaffolding arrangement including dismantling at the end of work and carriage from Gr Floor to 3rd Floor as directed by EIC. 39 Add: GST @18% on total amount ofabove item (i.e. from item Sl. No. 1.00 to 28.00) as applicable 40 Add: LWC @1% on total amount ofabove item (i.e. from item Sl. No. 1.00 to 29.00) as applicable 41 Note: 1) Quoted Rates are inclusive of the all taxes, duties & cess as applicable with cost of maintenance, servicing,supply & replacement of spares for 1 (One) year from the date of commissioning.2) Total is rounded off to the nearest rupee and inclusive of all taxes, duties & cess as applicable.