| 1 | A. CONSTRUCTION OF NEW 33KV LINES |
| 2 | I) MONGSANGEI TO KEISHAMPAT WITH COVERED CONDUCTOR |
| 3 | 14.5m long Galvanised steel pole (410-SP-76) @ 380 Kg |
| 4 | Galvanised Pole top brackets, X-arms for single pole, double plole and four pole structures, bracings, back clamps, flange & stiffener of pole jointing, etc. |
| 5 | Single Circuit |
| 6 | Pole Top Bracket (4.121 Kg) |
| 7 | 2m long Single Pole X-arm (19.12 Kg) |
| 8 | Double Pole X-arm (23.9 Kg) |
| 9 | Four Pole X-arm (30.59 Kg) |
| 10 | Double Pole top belt (12.24 Kg) |
| 11 | Double Pole bottom belt (12.58 Kg) |
| 12 | Double Pole bracing (11.93 Kg) |
| 13 | Four Pole top belt (21.53 Kg) |
| 14 | Four Pole bottom belt (21.53 Kg) |
| 15 | Four Pole bracing (15.89 Kg) |
| 16 | Pole Jointing |
| 17 | i) Lower Flange (7 Kg) |
| 18 | ii) Upper Flange (8 Kg) |
| 19 | iii) Lower Stiffener Plate (0.5 Kg) |
| 20 | iv) Upper Stiffener Plate (0.4 Kg) |
| 21 | Clamp for Single Pole Structure |
| 22 | Pole Top Bracket at 165.1 mmOutside Diameter (2.08025 Kg) |
| 23 | X-arm at 165.1 mm Outside Diameter (2.08025 Kg) |
| 24 | Clamp for Double Pole Structure |
| 25 | X-arm at 165.1 mm Outside Diameter (2.08025 Kg) |
| 26 | Top Belt at 165.1 mm (2.08025 Kg) |
| 27 | Bottom Belt at 193.7 mm Outside Diameter level (2.355 Kg) |
| 28 | Stay Clamp (1.76625 Kg) |
| 29 | Clamp for Four Pole Structure |
| 30 | X-arm at 165.1 mm Outside Diameter (2.08025 Kg) |
| 31 | Top Belt at 165.1 mm (2.08025 Kg) |
| 32 | Bottom Belt at 193.7 mm Outside Diameter level (2.355 Kg) |
| 33 | Stay Clamp (1.76625 Kg) |
| 34 | Double Circuit |
| 35 | Pole Top Bracket (4.121 Kg) |
| 36 | 2m long Single Pole X-arm (19.12 Kg) |
| 37 | Double Pole X-arm (23.9 Kg) |
| 38 | Four Pole X-arm (30.59 Kg) |
| 39 | Double Pole top belt (12.24 Kg) |
| 40 | Double Pole bottom belt (12.58 Kg) |
| 41 | Double Pole bracing (11.93 Kg) |
| 42 | Four Pole top belt (21.53 Kg) |
| 43 | Four Pole bottom belt (21.53 Kg) |
| 44 | Four Pole bracing (15.89 Kg) |
| 45 | Pole Jointing |
| 46 | i) Lower Flange (7 Kg) |
| 47 | ii) Upper Flange (8 Kg) |
| 48 | iii) Lower Stiffener Plate (0.5 Kg) |
| 49 | iv) Upper Stiffener Plate (0.4 Kg) |
| 50 | Clamp for Single Pole Structure |
| 51 | Pole Top Bracket at 165.1 mm Outside Diameter (2.08025 Kg) |
| 52 | X-arm at 165.1 mm Outside Diameter (2.08025 Kg) |
| 53 | Clamp for Double Pole Structure |
| 54 | X-arm at 165.1 mm Outside Diameter (2.08025 Kg) |
| 55 | Top Belt at 165.1 mm (2.08025 Kg) |
| 56 | Bottom Belt at 193.7 mm Outside Diameter level (2.355 Kg) |
| 57 | Stay Clamp (1.76625 Kg) |
| 58 | Clamp for Four Pole Structure |
| 59 | X-arm at 165.1 mm Outside Diameter (2.08025 Kg) |
| 60 | Top Belt at 165.1 mm (2.08025 Kg) |
| 61 | Bottom Belt at 193.7 mm Outside Diameter level (2.355 Kg) |
| 62 | Stay Clamp (1.76625 Kg) |
| 63 | Galvanised Bolts & Nuts (with spring) |
| 64 | 33KV Pin Insulator as per IS:731-1971 with GI Pin L300N |
| 65 | 70 KN Disc Insulator |
| 66 | Tension hardware fittings for 70 KN disc insulator |
| 67 | 33 KV Covered Conductor Triple Layer Type with AAAC 100 sqmm (or 99 sqmm) conductor |
| 68 | Stay Set complete with stay wire (7/4.00 mm) as per IS:2141:1992 & Clamps |
| 69 | G.I.wire 8 SWG (4mm, 55Kgf/Sqmm Hard quality or No.6 SWG, 5mm, 32 Kgf/Sqmm, Soft quality) for Earth wire & Guarding |
| 70 | Earthing Set complete with Earthing Electrode of GI Pipe, 40mm Dia, 2.5 to 3.00 Mtr. Long and G.I. wire 8 SWG (4mm, 55Kgf/Sqmm hard quality) |
| 71 | Insulation Piercing Connector - 33 KV CC to CC (100 sqmm) |
| 72 | Non Metallic helical ties for covered conductor |
| 73 | Insulated tension mid span joint/repair sleeve for 33KV Covered Conductor (80 sqmm) |
| 74 | Insulation Piercing Connector for 33 KV CC (100 sqmm) to Bare (75-150 sqmm) |
| 75 | 33KV 100 sqmm covered conductor End Seal Caps, heat or cold shrink type |
| 76 | Earthwire |
| 77 | II) 132/33KV GHAMPHAZOL SS-33/11KV GHAMPHAZOL SS |
| 78 | 10m long Steel Pole (410-SP-48) |
| 79 | Pole top bracket with M.S. Flat 50*10mm @3.9Kg/Mtr |
| 80 | 2m long single pole X-arm with channel (ISMC-100) @9.2Kg/Mtr |
| 81 | 2.5m long double pole X-arm with channel (ISMC-100) @9.2Kg/Mtr |
| 82 | 3.2m long 4 pole X-arm with channel (ISMC-100) @9.2Kg/Mtr |
| 83 | Bracing set for double pole with M.S. Angle 75x75x6mm @6.8Kg/Mtr (3.2m) |
| 84 | Bracing set for 4 pole with M.S. Angle 75x75x6mm @6.8Kg/Mtr (3.5m) |
| 85 | Clamp for X-arm and bracing set with M.S. Flat 50x10mm @3.9Kg/Mtr (0.436m) |
| 86 | 33KV Pin Insulator as per IS:731-1971 with GI Pin L300N |
| 87 | Disc Insulator with hardware fittings |
| 88 | ACSR (Raccoon Conductor), 6/4.09, 1/4.09 conforming to IS:398 (Part-II)/1976 |
| 89 | GI Bolts & Nuts (assorted) |
| 90 | Stay Set complete with stay wire (7/4.00 mm) as per IS:2141:1992 & Clamps |
| 91 | Earthing Set complete with Earthing Electrode of GI Pipe, 40mm Dia, 2.5 to 3.00 Mtr. Long and G.I. wire 8 SWG (4mm, 55Kgf/Sqmm hard quality) |
| 92 | III) HUNDUNG TO UKHRUL KHUNJAO |
| 93 | 10m long Steel Pole (410-SP-48) |
| 94 | Pole top bracket with M.S. Flat 50*10mm @3.9Kg/Mtr |
| 95 | 2m long single pole X-arm with channel (ISMC-100) @9.2Kg/Mtr |
| 96 | 2.5m long double pole X-arm with channel (ISMC-100) @9.2Kg/Mtr |
| 97 | 3.2m long 4 pole X-arm with channel (ISMC-100) @9.2Kg/Mtr |
| 98 | Bracing set for double pole with M.S. Angle 75x75x6mm @6.8Kg/Mtr (3.2m) |
| 99 | Bracing set for 4 pole with M.S. Angle 75x75x6mm @6.8Kg/Mtr (3.5m) |
| 100 | Clamp for X-arm and bracing set with M.S. Flat 50x10mm @3.9Kg/Mtr (0.436m) |
| 101 | 33KV Pin Insulator as per IS:731-1971 with GI Pin L300N |
| 102 | Disc Insulator with hardware fittings |
| 103 | HT Guy Insulator |
| 104 | ACSR (Raccoon Conductor), 6/4.09, 1/4.09 conforming to IS:398 (Part-II)/1976 |
| 105 | GI Bolts & Nuts (assorted) |
| 106 | Stay Set complete with stay wire (7/4.00 mm) as per IS:2141:1992 & Clamps |
| 107 | Earthing Set complete with Earthing Electrode of GI Pipe, 40mm Dia, 2.5 to 3.00 Mtr. Long and G.I. wire 8 SWG (4mm, 55Kgf/Sqmm hard quality) |
| 108 | B. REPLACEMENT OF EXISTING CONDUCTOR OF 33KV LINE WITH COVERED/SHEATHED CONDUCTOR |
| 109 | I) KHUMAN LAMPAK TO KEISHAMPAT VIA KANGLA |
| 110 | 14.5m long Galvanised steel pole (410-SP-76) @ 380 Kg |
| 111 | Galvanised Pole top brackets, X-arms for single pole, double plole and four pole structures, bracings, back clamps, flange & stiffener of pole jointing, etc. |
| 112 | Single Circuit |
| 113 | Pole Top Bracket (4.121 Kg) |
| 114 | 2m long Single Pole X-arm (19.12 Kg) |
| 115 | Double Pole X-arm (23.9 Kg) |
| 116 | Four Pole X-arm (30.59 Kg) |
| 117 | Double Pole top belt (12.24 Kg) |
| 118 | Double Pole bottom belt (12.58 Kg) |
| 119 | Double Pole bracing (11.93 Kg) |
| 120 | Four Pole top belt (21.53 Kg) |
| 121 | Four Pole bottom belt (21.53 Kg) |
| 122 | Four Pole bracing (15.89 Kg) |
| 123 | Pole Jointing |
| 124 | i) Lower Flange (7 Kg) |
| 125 | ii) Upper Flange (8 Kg) |
| 126 | iii) Lower Stiffener Plate (0.5 Kg) |
| 127 | iv) Upper Stiffener Plate (0.4 Kg) |
| 128 | Clamp for Single Pole Structure |
| 129 | Pole Top Bracket at 165.1 mmOutside Diameter (2.08025 Kg) |
| 130 | X-arm at 165.1 mm Outside Diameter (2.08025 Kg) |
| 131 | Clamp for Double Pole Structure |
| 132 | X-arm at 165.1 mm Outside Diameter (2.08025 Kg) |
| 133 | Top Belt at 165.1 mm (2.08025 Kg) |
| 134 | Bottom Belt at 193.7 mm Outside Diameter level (2.355 Kg) |
| 135 | Stay Clamp (1.76625 Kg) |
| 136 | Clamp for Four Pole Structure |
| 137 | X-arm at 165.1 mm Outside Diameter (2.08025 Kg) |
| 138 | Top Belt at 165.1 mm (2.08025 Kg) |
| 139 | Bottom Belt at 193.7 mm Outside Diameter level (2.355 Kg) |
| 140 | Stay Clamp (1.76625 Kg) |
| 141 | Double Circuit |
| 142 | Pole Top Bracket (4.121 Kg) |
| 143 | 2m long Single Pole X-arm (19.12 Kg) |
| 144 | Double Pole X-arm (23.9 Kg) |
| 145 | Four Pole X-arm (30.59 Kg) |
| 146 | Double Pole top belt (12.24 Kg) |
| 147 | Double Pole bottom belt (12.58 Kg) |
| 148 | Double Pole bracing (11.93 Kg) |
| 149 | Four Pole top belt (21.53 Kg) |
| 150 | Four Pole bottom belt (21.53 Kg) |
| 151 | Four Pole bracing (15.89 Kg) |
| 152 | Pole Jointing |
| 153 | i) Lower Flange (7 Kg) |
| 154 | ii) Upper Flange (8 Kg) |
| 155 | iii) Lower Stiffener Plate (0.5 Kg) |
| 156 | iv) Upper Stiffener Plate (0.4 Kg) |
| 157 | Clamp for Single Pole Structure |
| 158 | Pole Top Bracket at 165.1 mm Outside Diameter (2.08025 Kg) |
| 159 | X-arm at 165.1 mm Outside Diameter (2.08025 Kg) |
| 160 | Clamp for Double Pole Structure |
| 161 | X-arm at 165.1 mm Outside Diameter (2.08025 Kg) |
| 162 | Top Belt at 165.1 mm (2.08025 Kg) |
| 163 | Bottom Belt at 193.7 mm Outside Diameter level (2.355 Kg) |
| 164 | Stay Clamp (1.76625 Kg) |
| 165 | Clamp for Four Pole Structure |
| 166 | X-arm at 165.1 mm Outside Diameter (2.08025 Kg) |
| 167 | Top Belt at 165.1 mm (2.08025 Kg) |
| 168 | Bottom Belt at 193.7 mm Outside Diameter level (2.355 Kg) |
| 169 | Stay Clamp (1.76625 Kg) |
| 170 | Galvanised Bolts & Nuts (with spring) |
| 171 | 33KV Pin Insulator as per IS:731-1971 with GI Pin L300N |
| 172 | 70 KN Disc Insulator |
| 173 | Tension hardware fittings for 70 KN disc insulator |
| 174 | 33 KV Covered Conductor Triple Layer Type with AAAC 100 sqmm (or 99 sqmm) conductor |
| 175 | Stay Set complete with stay wire (7/4.00 mm) as per IS:2141:1992 & Clamps |
| 176 | G.I.wire 8 SWG (4mm, 55Kgf/Sqmm Hard quality or No.6 SWG, 5mm, 32 Kgf/Sqmm, Soft quality) for Earth wire & Guarding |
| 177 | Earthing Set complete with Earthing Electrode of GI Pipe, 40mm Dia, 2.5 to 3.00 Mtr. Long and G.I. wire 8 SWG (4mm, 55Kgf/Sqmm hard quality) |
| 178 | Insulation Piercing Connector - 33 KV CC to CC (100 sqmm) |
| 179 | Non Metallic helical ties for covered conductor |
| 180 | Insulated tension mid span joint/repair sleeve for 33KV Covered Conductor (80 sqmm) |
| 181 | Insulation Piercing Connector for 33 KV CC (100 sqmm) to Bare (75-150 sqmm) |
| 182 | 33KV 100 sqmm covered conductor End Seal Caps, heat or cold shrink type |
| 183 | Earthwire |
| 184 | II) SINAM CHINGJIN TO LAMPHEL |
| 185 | 12m long Steel Pole (410-SP-66) @ 322 Kg |
| 186 | 2m long single pole X-arm with channel (ISMC-100) @9.2Kg/Mtr |
| 187 | 2.5m long double pole X-arm with channel (ISMC-100) @9.2Kg/Mtr |
| 188 | 3.2m long 4 pole X-arm with channel (ISMC-100) @9.2Kg/Mtr |
| 189 | Bracing set for double pole with M.S. Angle 75x75x6mm @6.8Kg/Mtr (3.2m) |
| 190 | Bracing set for 4 pole with M.S. Angle 75x75x6mm @6.8Kg/Mtr (3.5m) |
| 191 | Pole top bracket with M.S. Flat 50*10mm @3.9Kg/Mtr |
| 192 | Clamp for X-arm and bracing set with M.S. Flat 50x10mm @3.9Kg/Mtr (0.436m) |
| 193 | GI Bolts & Nuts (assorted) |
| 194 | 33KV Pin Insulator as per IS:731-1971 with GI Pin L300N |
| 195 | 70 KN Disc Insulator |
| 196 | Tension hardware fittings for 70 KN disc insulator |
| 197 | 33 KV Covered Conductor Triple Layer Type with AAAC 100 sqmm (or 99 sqmm) conductor |
| 198 | Stay Set complete with stay wire (7/4.00 mm) as per IS:2141:1992 & Clamps |
| 199 | G.I.wire 8 SWG (4mm, 55Kgf/Sqmm Hard quality or No.6 SWG, 5mm, 32 Kgf/Sqmm, Soft quality) for Earth wire & Guarding |
| 200 | Earthing Set complete with Earthing Electrode of GI Pipe, 40mm Dia, 2.5 to 3.00 Mtr. Long and G.I. wire 8 SWG (4mm, 55Kgf/Sqmm hard quality) |
| 201 | Insulation Piercing Connector - 33 KV CC to CC (100 sqmm) |
| 202 | Non Metallic helical ties for covered conductor |
| 203 | Insulated tension mid span joint/repair sleeve for 33KV Covered Conductor (80 sqmm) |
| 204 | Insulation Piercing Connector for 33 KV CC (100 sqmm) to Bare (75-150 sqmm) |
| 205 | 33KV 100 sqmm covered conductor End Seal Caps, heat or cold shrink type |
| 206 | Earthwire |
| 207 | C. SYSTEM IMPROVEMENT OF 33KV LINE |
| 208 | I) TAMENGLONG TO TOUSEM |
| 209 | 12m long Steel Pole (410-SP-66) @ 322 Kg |
| 210 | Pole top bracket with M.S. Flat 50*10mm @3.9Kg/Mtr |
| 211 | 2m long single pole X-arm with channel (ISMC-100) @9.2Kg/Mtr |
| 212 | 2.5m long double pole X-arm with channel (ISMC-100) @9.2Kg/Mtr |
| 213 | 3.2m long 4 pole X-arm with channel (ISMC-100) @9.2Kg/Mtr |
| 214 | Bracing set for double pole with M.S. Angle 75x75x6mm @6.8Kg/Mtr (3.2m) |
| 215 | Bracing set for 4 pole with M.S. Angle 75x75x6mm @6.8Kg/Mtr (3.5m) |
| 216 | Clamp for X-arm and bracing set with M.S. Flat 50x10mm @3.9Kg/Mtr (0.436m) |
| 217 | 33KV Pin Insulator as per IS:731-1971 with GI Pin L300N |
| 218 | Disc Insulator with hardware fittings |
| 219 | ACSR (Raccoon Conductor), 6/4.09, 1/4.09 conforming to IS:398 (Part-II)/1976 |
| 220 | GI Bolts & Nuts (assorted) |
| 221 | Stay Set complete with stay wire (7/4.00 mm) as per IS:2141:1992 & Clamps |
| 222 | G.I.wire 8 SWG (4mm, 55Kgf/Sqmm Hard quality or No.6 SWG, 5mm, 32 Kgf/Sqmm, Soft quality) for Earth wire & Guarding |
| 223 | Earthing Set complete with Earthing Electrode of GI Pipe, 40mm Dia, 2.5 to 3.00 Mtr. Long and G.I. wire 8 SWG (4mm, 55Kgf/Sqmm hard quality) |
| 224 | II) YUREMBAM TO NONEY |
| 225 | 12m long Steel Pole (410-SP-66) @ 322 Kg |
| 226 | Pole top bracket with M.S. Flat 50*10mm @3.9Kg/Mtr |
| 227 | 2m long single pole X-arm with channel (ISMC-100) @9.2Kg/Mtr |
| 228 | 2.5m long double pole X-arm with channel (ISMC-100) @9.2Kg/Mtr |
| 229 | 3.2m long 4 pole X-arm with channel (ISMC-100) @9.2Kg/Mtr |
| 230 | Bracing set for double pole with M.S. Angle 75x75x6mm @6.8Kg/Mtr (3.2m) |
| 231 | Bracing set for 4 pole with M.S. Angle 75x75x6mm @6.8Kg/Mtr (3.5m) |
| 232 | Clamp for X-arm and bracing set with M.S. Flat 50x10mm @3.9Kg/Mtr (0.436m) |
| 233 | 33KV Pin Insulator as per IS:731-1971 with GI Pin L300N |
| 234 | Disc Insulator with hardware fittings |
| 235 | ACSR (Raccoon Conductor), 6/4.09, 1/4.09 conforming to IS:398 (Part-II)/1976 |
| 236 | GI Bolts & Nuts (assorted) |
| 237 | Stay Set complete with stay wire (7/4.00 mm) as per IS:2141:1992 & Clamps |
| 238 | G.I.wire 8 SWG (4mm, 55Kgf/Sqmm Hard quality or No.6 SWG, 5mm, 32 Kgf/Sqmm, Soft quality) for Earth wire & Guarding |
| 239 | Earthing Set complete with Earthing Electrode of GI Pipe, 40mm Dia, 2.5 to 3.00 Mtr. Long and G.I. wire 8 SWG (4mm, 55Kgf/Sqmm hard quality) |
| 240 | III) KANGPOKPI TO TAMEI |
| 241 | 10m long Steel Pole (410-SP-48) |
| 242 | Pole top bracket with M.S. Flat 50*10mm @3.9Kg/Mtr |
| 243 | 2m long single pole X-arm with channel (ISMC-100) @9.2Kg/Mtr |
| 244 | 2.5m long double pole X-arm with channel (ISMC-100) @9.2Kg/Mtr |
| 245 | 3.2m long 4 pole X-arm with channel (ISMC-100) @9.2Kg/Mtr |
| 246 | Bracing set for double pole with M.S. Angle 75x75x6mm @6.8Kg/Mtr (3.2m) |
| 247 | Bracing set for 4 pole with M.S. Angle 75x75x6mm @6.8Kg/Mtr (3.5m) |
| 248 | Clamp for X-arm and bracing set with M.S. Flat 50x10mm @3.9Kg/Mtr (0.436m) |
| 249 | 33KV Pin Insulator as per IS:731-1971 with GI Pin L300N |
| 250 | Disc Insulator with hardware fittings |
| 251 | ACSR (Raccoon Conductor), 6/4.09, 1/4.09 conforming to IS:398 (Part-II)/1976 |
| 252 | GI Bolts & Nuts (assorted) |
| 253 | Stay Set complete with stay wire (7/4.00 mm) as per IS:2141:1992 & Clamps |
| 254 | Earthing Set complete with Earthing Electrode of GI Pipe, 40mm Dia, 2.5 to 3.00 Mtr. Long and G.I. wire 8 SWG (4mm, 55Kgf/Sqmm hard quality) |
| 255 | IV) RENGPANG TO KHOUPUM |
| 256 | 12m long Steel Pole (410-SP-66) @ 322 Kg |
| 257 | Pole top bracket with M.S. Flat 50*10mm @3.9Kg/Mtr |
| 258 | 2m long single pole X-arm with channel (ISMC-100) @9.2Kg/Mtr |
| 259 | 2.5m long double pole X-arm with channel (ISMC-100) @9.2Kg/Mtr |
| 260 | 3.2m long 4 pole X-arm with channel (ISMC-100) @9.2Kg/Mtr |
| 261 | Bracing set for double pole with M.S. Angle 75x75x6mm @6.8Kg/Mtr (3.2m) |
| 262 | Bracing set for 4 pole with M.S. Angle 75x75x6mm @6.8Kg/Mtr (3.5m) |
| 263 | Clamp for X-arm and bracing set with M.S. Flat 50x10mm @3.9Kg/Mtr (0.436m) |
| 264 | 33KV Pin Insulator as per IS:731-1971 with GI Pin L300N |
| 265 | Disc Insulator with hardware fittings |
| 266 | ACSR (Raccoon Conductor), 6/4.09, 1/4.09 conforming to IS:398 (Part-II)/1976 |
| 267 | GI Bolts & Nuts (assorted) |
| 268 | Stay Set complete with stay wire (7/4.00 mm) as per IS:2141:1992 & Clamps |
| 269 | G.I.wire 8 SWG (4mm, 55Kgf/Sqmm Hard quality or No.6 SWG, 5mm, 32 Kgf/Sqmm, Soft quality) for Earth wire & Guarding |
| 270 | Earthing Set complete with Earthing Electrode of GI Pipe, 40mm Dia, 2.5 to 3.00 Mtr. Long and G.I. wire 8 SWG (4mm, 55Kgf/Sqmm hard quality) |
| 271 | V) KAKCHING TO WANGJING |
| 272 | 10m long Steel Pole (410-SP-48) |
| 273 | Pole top bracket with M.S. Flat 50*10mm @3.9Kg/Mtr |
| 274 | 2m long single pole X-arm with channel (ISMC-100) @9.2Kg/Mtr |
| 275 | 2.5m long double pole X-arm with channel (ISMC-100) @9.2Kg/Mtr |
| 276 | 3.2m long 4 pole X-arm with channel (ISMC-100) @9.2Kg/Mtr |
| 277 | Bracing set for double pole with M.S. Angle 75x75x6mm @6.8Kg/Mtr (3.2m) |
| 278 | Bracing set for 4 pole with M.S. Angle 75x75x6mm @6.8Kg/Mtr (3.5m) |
| 279 | 33KV Pin Insulator as per IS:731-1971 with GI Pin L300N |
| 280 | Disc Insulator with hardware fittings |
| 281 | ACSR (Raccoon Conductor), 6/4.09, 1/4.09 conforming to IS:398 (Part-II)/1976 |
| 282 | Stay Set complete with stay wire (7/4.00 mm) as per IS:2141:1992 & Clamps |
| 283 | Clamp for X-arm and bracing set with M.S. Flat 50x10mm @3.9Kg/Mtr (0.436m) |
| 284 | GI Bolts & Nuts (assorted) |
| 285 | Earthing Set complete with Earthing Electrode of GI Pipe, 40mm Dia, 2.5 to 3.00 Mtr. Long and G.I. wire 8 SWG (4mm, 55Kgf/Sqmm hard quality) |
| 286 | G.I. Wire |
| 287 | VI) KAKCHING TO MAYANG IMPHAL |
| 288 | 10m long Steel Pole (410-SP-48) |
| 289 | Pole top bracket with M.S. Flat 50*10mm @3.9Kg/Mtr |
| 290 | 2m long single pole X-arm with channel (ISMC-100) @9.2Kg/Mtr |
| 291 | 2.5m long double pole X-arm with channel (ISMC-100) @9.2Kg/Mtr |
| 292 | 3.2m long 4 pole X-arm with channel (ISMC-100) @9.2Kg/Mtr |
| 293 | Bracing set for double pole with M.S. Angle 75x75x6mm @6.8Kg/Mtr (3.2m) |
| 294 | Bracing set for 4 pole with M.S. Angle 75x75x6mm @6.8Kg/Mtr (3.5m) |
| 295 | 33KV Pin Insulator as per IS:731-1971 with GI Pin L300N |
| 296 | Disc Insulator with hardware fittings |
| 297 | ACSR (Raccoon Conductor), 6/4.09, 1/4.09 conforming to IS:398 (Part-II)/1976 |
| 298 | Stay Set complete with stay wire (7/4.00 mm) as per IS:2141:1992 & Clamps |
| 299 | Clamp for X-arm and bracing set with M.S. Flat 50x10mm @3.9Kg/Mtr (0.436m) |
| 300 | GI Bolts & Nuts (assorted) |
| 301 | Earthing Set complete with Earthing Electrode of GI Pipe, 40mm Dia, 2.5 to 3.00 Mtr. Long and G.I. wire 8 SWG (4mm, 55Kgf/Sqmm hard quality) |
| 302 | G.I. Wire |
| 303 | VII) NAPETPALLI TO SAGOLMANG |
| 304 | 12m long Steel Pole (410-SP-66) @ 322 Kg |
| 305 | Pole top bracket with M.S. Flat 50*10mm @3.9Kg/Mtr |
| 306 | 2m long single pole X-arm with channel (ISMC-100) @9.2Kg/Mtr |
| 307 | 2.5m long double pole X-arm with channel (ISMC-100) @9.2Kg/Mtr |
| 308 | 3.2m long 4 pole X-arm with channel (ISMC-100) @9.2Kg/Mtr |
| 309 | Bracing set for double pole with M.S. Angle 75x75x6mm @6.8Kg/Mtr (3.2m) |
| 310 | Bracing set for 4 pole with M.S. Angle 75x75x6mm @6.8Kg/Mtr (3.5m) |
| 311 | Clamp for X-arm and bracing set with M.S. Flat 50x10mm @3.9Kg/Mtr (0.436m) |
| 312 | 33KV Pin Insulator as per IS:731-1971 with GI Pin L300N |
| 313 | Disc Insulator with hardware fittings |
| 314 | ACSR (Raccoon Conductor), 6/4.09, 1/4.09 conforming to IS:398 (Part-II)/1976 |
| 315 | GI Bolts & Nuts (assorted) |
| 316 | Stay Set complete with stay wire (7/4.00 mm) as per IS:2141:1992 & Clamps |
| 317 | G.I.wire 8 SWG (4mm, 55Kgf/Sqmm Hard quality or No.6 SWG, 5mm, 32 Kgf/Sqmm, Soft quality) for Earth wire & Guarding |
| 318 | Earthing Set complete with Earthing Electrode of GI Pipe, 40mm Dia, 2.5 to 3.00 Mtr. Long and G.I. wire 8 SWG (4mm, 55Kgf/Sqmm hard quality) |
| 319 | VIII) YUREMBAM TO MAYANG IMPHAL |
| 320 | 10m long Steel Pole (410-SP-48) |
| 321 | Pole top bracket with M.S. Flat 50*10mm @3.9Kg/Mtr |
| 322 | 2m long single pole X-arm with channel (ISMC-100) @9.2Kg/Mtr |
| 323 | 2.5m long double pole X-arm with channel (ISMC-100) @9.2Kg/Mtr |
| 324 | 3.2m long 4 pole X-arm with channel (ISMC-100) @9.2Kg/Mtr |
| 325 | Bracing set for double pole with M.S. Angle 75x75x6mm @6.8Kg/Mtr (3.2m) |
| 326 | Bracing set for 4 pole with M.S. Angle 75x75x6mm @6.8Kg/Mtr (3.5m) |
| 327 | Clamp for X-arm and bracing set with M.S. Flat 50x10mm @3.9Kg/Mtr (0.436m) |
| 328 | 33KV Pin Insulator as per IS:731-1971 with GI Pin L300N |
| 329 | Disc Insulator with hardware fittings |
| 330 | ACSR (Raccoon Conductor), 6/4.09, 1/4.09 conforming to IS:398 (Part-II)/1976 |
| 331 | GI Bolts & Nuts (assorted) |
| 332 | Stay Set complete with stay wire (7/4.00 mm) as per IS:2141:1992 & Clamps |
| 333 | G.I.wire 8 SWG (4mm, 55Kgf/Sqmm Hard quality or No.6 SWG, 5mm, 32 Kgf/Sqmm, Soft quality) for Earth wire & Guarding |
| 334 | Earthing Set complete with Earthing Electrode of GI Pipe, 40mm Dia, 2.5 to 3.00 Mtr. Long and G.I. wire 8 SWG (4mm, 55Kgf/Sqmm hard quality) |
| 335 | IX) NINGTHOUKHONG TO MOIRANG |
| 336 | 10m long Steel Pole (410-SP-48) |
| 337 | Pole top bracket with M.S. Flat 50*10mm @3.9Kg/Mtr |
| 338 | 2m long single pole X-arm with channel (ISMC-100) @9.2Kg/Mtr |
| 339 | 2.5m long double pole X-arm with channel (ISMC-100) @9.2Kg/Mtr |
| 340 | 3.2m long 4 pole X-arm with channel (ISMC-100) @9.2Kg/Mtr |
| 341 | Bracing set for double pole with M.S. Angle 75x75x6mm @6.8Kg/Mtr (3.2m) |
| 342 | Bracing set for 4 pole with M.S. Angle 75x75x6mm @6.8Kg/Mtr (3.5m) |
| 343 | Clamp for X-arm and bracing set with M.S. Flat 50x10mm @3.9Kg/Mtr (0.436m) |
| 344 | 33KV Pin Insulator as per IS:731-1971 with GI Pin L300N |
| 345 | Disc Insulator with hardware fittings |
| 346 | ACSR (Raccoon Conductor), 6/4.09, 1/4.09 conforming to IS:398 (Part-II)/1976 |
| 347 | GI Bolts & Nuts (assorted) |
| 348 | Stay Set complete with stay wire (7/4.00 mm) as per IS:2141:1992 & Clamps |
| 349 | G.I.wire 8 SWG (4mm, 55Kgf/Sqmm Hard quality or No.6 SWG, 5mm, 32 Kgf/Sqmm, Soft quality) for Earth wire & Guarding |
| 350 | Earthing Set complete with Earthing Electrode of GI Pipe, 40mm Dia, 2.5 to 3.00 Mtr. Long and G.I. wire 8 SWG (4mm, 55Kgf/Sqmm hard quality) |
| 351 | X) YUREMBAM TO MAYANG LANGJING |
| 352 | 12m long Steel Pole (410-SP-66) @ 322 Kg |
| 353 | Pole top bracket with M.S. Flat 50*10mm @3.9Kg/Mtr |
| 354 | 2m long single pole X-arm with channel (ISMC-100) @9.2Kg/Mtr |
| 355 | 2.5m long double pole X-arm with channel (ISMC-100) @9.2Kg/Mtr |
| 356 | 3.2m long 4 pole X-arm with channel (ISMC-100) @9.2Kg/Mtr |
| 357 | Bracing set for double pole with M.S. Angle 75x75x6mm @6.8Kg/Mtr (3.2m) |
| 358 | Bracing set for 4 pole with M.S. Angle 75x75x6mm @6.8Kg/Mtr (3.5m) |
| 359 | Clamp for X-arm and bracing set with M.S. Flat 50x10mm @3.9Kg/Mtr (0.436m) |
| 360 | 33KV Pin Insulator as per IS:731-1971 with GI Pin L300N |
| 361 | Disc Insulator with hardware fittings |
| 362 | ACSR (Raccoon Conductor), 6/4.09, 1/4.09 conforming to IS:398 (Part-II)/1976 |
| 363 | GI Bolts & Nuts (assorted) |
| 364 | Stay Set complete with stay wire (7/4.00 mm) as per IS:2141:1992 & Clamps |
| 365 | G.I.wire 8 SWG (4mm, 55Kgf/Sqmm Hard quality or No.6 SWG, 5mm, 32 Kgf/Sqmm, Soft quality) for Earth wire & Guarding |
| 366 | Earthing Set complete with Earthing Electrode of GI Pipe, 40mm Dia, 2.5 to 3.00 Mtr. Long and G.I. wire 8 SWG (4mm, 55Kgf/Sqmm hard quality) |
| 367 | XI) KHUMAN LAMPAK TO MANTRIPUKHRI |
| 368 | 14.5m long Galvanised steel pole (410-SP-76) @ 380 Kg |
| 369 | Galvanised Pole top brackets, X-arms for single pole, double plole and four pole structures, bracings, back clamps, flange & stiffener of pole jointing, etc. |
| 370 | Single Circuit |
| 371 | Pole Top Bracket (4.121 Kg) |
| 372 | 2m long Single Pole X-arm (19.12 Kg) |
| 373 | Double Pole X-arm (23.9 Kg) |
| 374 | Four Pole X-arm (30.59 Kg) |
| 375 | Double Pole top belt (12.24 Kg) |
| 376 | Double Pole bottom belt (12.58 Kg) |
| 377 | Double Pole bracing (11.93 Kg) |
| 378 | Four Pole top belt (21.53 Kg) |
| 379 | Four Pole bottom belt (21.53 Kg) |
| 380 | Four Pole bracing (15.89 Kg) |
| 381 | Pole Jointing |
| 382 | i) Lower Flange (7 Kg) |
| 383 | ii) Upper Flange (8 Kg) |
| 384 | iii) Lower Stiffener Plate (0.5 Kg) |
| 385 | iv) Upper Stiffener Plate (0.4 Kg) |
| 386 | Clamp for Single Pole Structure |
| 387 | Pole Top Bracket at 165.1 mmOutside Diameter (2.08025 Kg) |
| 388 | X-arm at 165.1 mm Outside Diameter (2.08025 Kg) |
| 389 | Clamp for Double Pole Structure |
| 390 | X-arm at 165.1 mm Outside Diameter (2.08025 Kg) |
| 391 | Top Belt at 165.1 mm (2.08025 Kg) |
| 392 | Bottom Belt at 193.7 mm Outside Diameter level (2.355 Kg) |
| 393 | Stay Clamp (1.76625 Kg) |
| 394 | Clamp for Four Pole Structure |
| 395 | X-arm at 165.1 mm Outside Diameter (2.08025 Kg) |
| 396 | Top Belt at 165.1 mm (2.08025 Kg) |
| 397 | Bottom Belt at 193.7 mm Outside Diameter level (2.355 Kg) |
| 398 | Stay Clamp (1.76625 Kg) |
| 399 | Double Circuit |
| 400 | Pole Top Bracket (4.121 Kg) |
| 401 | 2m long Single Pole X-arm (19.12 Kg) |
| 402 | Double Pole X-arm (23.9 Kg) |
| 403 | Four Pole X-arm (30.59 Kg) |
| 404 | Double Pole top belt (12.24 Kg) |
| 405 | Double Pole bottom belt (12.58 Kg) |
| 406 | Double Pole bracing (11.93 Kg) |
| 407 | Four Pole top belt (21.53 Kg) |
| 408 | Four Pole bottom belt (21.53 Kg) |
| 409 | Four Pole bracing (15.89 Kg) |
| 410 | Pole Jointing |
| 411 | i) Lower Flange (7 Kg) |
| 412 | ii) Upper Flange (8 Kg) |
| 413 | iii) Lower Stiffener Plate (0.5 Kg) |
| 414 | iv) Upper Stiffener Plate (0.4 Kg) |
| 415 | Clamp for Single Pole Structure |
| 416 | Pole Top Bracket at 165.1 mm Outside Diameter (2.08025 Kg) |
| 417 | X-arm at 165.1 mm Outside Diameter (2.08025 Kg) |
| 418 | Clamp for Double Pole Structure |
| 419 | X-arm at 165.1 mm Outside Diameter (2.08025 Kg) |
| 420 | Top Belt at 165.1 mm (2.08025 Kg) |
| 421 | Bottom Belt at 193.7 mm Outside Diameter level (2.355 Kg) |
| 422 | Stay Clamp (1.76625 Kg) |
| 423 | Clamp for Four Pole Structure |
| 424 | X-arm at 165.1 mm Outside Diameter (2.08025 Kg) |
| 425 | Top Belt at 165.1 mm (2.08025 Kg) |
| 426 | Bottom Belt at 193.7 mm Outside Diameter level (2.355 Kg) |
| 427 | Stay Clamp (1.76625 Kg) |
| 428 | Galvanised Bolts & Nuts (with spring) |
| 429 | 33KV Pin Insulator as per IS:731-1971 with GI Pin L300N |
| 430 | 70 KN Disc Insulator |
| 431 | Tension hardware fittings for 70 KN disc insulator |
| 432 | 33 KV Covered Conductor Triple Layer Type with AAAC 100 sqmm (or 99 sqmm) conductor |
| 433 | Stay Set complete with stay wire (7/4.00 mm) as per IS:2141:1992 & Clamps |
| 434 | G.I.wire 8 SWG (4mm, 55Kgf/Sqmm Hard quality or No.6 SWG, 5mm, 32 Kgf/Sqmm, Soft quality) for Earth wire & Guarding |
| 435 | Earthing Set complete with Earthing Electrode of GI Pipe, 40mm Dia, 2.5 to 3.00 Mtr. Long and G.I. wire 8 SWG (4mm, 55Kgf/Sqmm hard quality) |
| 436 | Insulation Piercing Connector - 33 KV CC to CC (100 sqmm) |
| 437 | Non Metallic helical ties for covered conductor |
| 438 | Insulated tension mid span joint/repair sleeve for 33KV Covered Conductor (80 sqmm) |
| 439 | Insulation Piercing Connector for 33 KV CC (100 sqmm) to Bare (75-150 sqmm) |
| 440 | 33KV 100 sqmm covered conductor End Seal Caps, heat or cold shrink type |
| 441 | Earthwire |
| 442 | XII) KAKCHING TO TENGNOUPAL |
| 443 | 10m long Steel Pole (410-SP-48) |
| 444 | Pole top bracket with M.S. Flat 50*10mm @3.9Kg/Mtr |
| 445 | 2m long single pole X-arm with channel (ISMC-100) @9.2Kg/Mtr |
| 446 | 2.5m long double pole X-arm with channel (ISMC-100) @9.2Kg/Mtr |
| 447 | 3.2m long 4 pole X-arm with channel (ISMC-100) @9.2Kg/Mtr |
| 448 | Bracing set for double pole with M.S. Angle 75x75x6mm @6.8Kg/Mtr (3.2m) |
| 449 | Bracing set for 4 pole with M.S. Angle 75x75x6mm @6.8Kg/Mtr (3.5m) |
| 450 | 33KV Pin Insulator as per IS:731-1971 with GI Pin L300N |
| 451 | Disc Insulator with hardware fittings |
| 452 | ACSR (Raccoon Conductor), 6/4.09, 1/4.09 conforming to IS:398 (Part-II)/1976 |
| 453 | Stay Set complete with stay wire (7/4.00 mm) as per IS:2141:1992 & Clamps |
| 454 | Clamp for X-arm and bracing set with M.S. Flat 50x10mm @3.9Kg/Mtr (0.436m) |
| 455 | GI Bolts & Nuts (assorted) |
| 456 | Earthing Set complete with Earthing Electrode of GI Pipe, 40mm Dia, 2.5 to 3.00 Mtr. Long and G.I. wire 8 SWG (4mm, 55Kgf/Sqmm hard quality) |
| 457 | G.I. Wire |
| 458 | XIII) YAINGANGPOKPI TO LITAN |
| 459 | 10m long Steel Pole (410-SP-48) |
| 460 | Pole top bracket with M.S. Flat 50*10mm @3.9Kg/Mtr |
| 461 | 2m long single pole X-arm with channel (ISMC-100) @9.2Kg/Mtr |
| 462 | 2.5m long double pole X-arm with channel (ISMC-100) @9.2Kg/Mtr |
| 463 | 3.2m long 4 pole X-arm with channel (ISMC-100) @9.2Kg/Mtr |
| 464 | Bracing set for double pole with M.S. Angle 75x75x6mm @6.8Kg/Mtr (3.2m) |
| 465 | Bracing set for 4 pole with M.S. Angle 75x75x6mm @6.8Kg/Mtr (3.5m) |
| 466 | Clamp for X-arm and bracing set with M.S. Flat 50x10mm @3.9Kg/Mtr (0.436m) |
| 467 | 33KV Pin Insulator as per IS:731-1971 with GI Pin L300N |
| 468 | Disc Insulator with hardware fittings |
| 469 | ACSR (Raccoon Conductor), 6/4.09, 1/4.09 conforming to IS:398 (Part-II)/1976 |
| 470 | GI Bolts & Nuts (assorted) |
| 471 | Stay Set complete with stay wire (7/4.00 mm) as per IS:2141:1992 & Clamps |
| 472 | Earthing Set complete with Earthing Electrode of GI Pipe, 40mm Dia, 2.5 to 3.00 Mtr. Long and G.I. wire 8 SWG (4mm, 55Kgf/Sqmm hard quality) |
| 473 | XIV) KAKCHING TO NEW CHAYANG |
| 474 | 10m long Steel Pole (410-SP-48) |
| 475 | Pole top bracket with M.S. Flat 50*10mm @3.9Kg/Mtr |
| 476 | 2m long single pole X-arm with channel (ISMC-100) @9.2Kg/Mtr |
| 477 | 2.5m long double pole X-arm with channel (ISMC-100) @9.2Kg/Mtr |
| 478 | 3.2m long 4 pole X-arm with channel (ISMC-100) @9.2Kg/Mtr |
| 479 | Bracing set for double pole with M.S. Angle 75x75x6mm @6.8Kg/Mtr (3.2m) |
| 480 | Bracing set for 4 pole with M.S. Angle 75x75x6mm @6.8Kg/Mtr (3.5m) |
| 481 | 33KV Pin Insulator as per IS:731-1971 with GI Pin L300N |
| 482 | Disc Insulator with hardware fittings |
| 483 | ACSR (Raccoon Conductor), 6/4.09, 1/4.09 conforming to IS:398 (Part-II)/1976 |
| 484 | Stay Set complete with stay wire (7/4.00 mm) as per IS:2141:1992 & Clamps |
| 485 | Clamp for X-arm and bracing set with M.S. Flat 50x10mm @3.9Kg/Mtr (0.436m) |
| 486 | GI Bolts & Nuts (assorted) |
| 487 | Earthing Set complete with Earthing Electrode of GI Pipe, 40mm Dia, 2.5 to 3.00 Mtr. Long and G.I. wire 8 SWG (4mm, 55Kgf/Sqmm hard quality) |
| 488 | G.I. Wire |
| 489 | XV) NILAKUTHI TO LEIMAKHONG |
| 490 | 10m long Steel Pole (410-SP-48) |
| 491 | Pole top bracket with M.S. Flat 50*10mm @3.9Kg/Mtr |
| 492 | 2m long single pole X-arm with channel (ISMC-100) @9.2Kg/Mtr |
| 493 | 2.5m long double pole X-arm with channel (ISMC-100) @9.2Kg/Mtr |
| 494 | 3.2m long 4 pole X-arm with channel (ISMC-100) @9.2Kg/Mtr |
| 495 | Bracing set for double pole with M.S. Angle 75x75x6mm @6.8Kg/Mtr (3.2m) |
| 496 | Bracing set for 4 pole with M.S. Angle 75x75x6mm @6.8Kg/Mtr (3.5m) |
| 497 | Clamp for X-arm and bracing set with M.S. Flat 50x10mm @3.9Kg/Mtr (0.436m) |
| 498 | 33KV Pin Insulator as per IS:731-1971 with GI Pin L300N |
| 499 | Disc Insulator with hardware fittings |
| 500 | ACSR (Raccoon Conductor), 6/4.09, 1/4.09 conforming to IS:398 (Part-II)/1976 |
| 501 | GI Bolts & Nuts (assorted) |
| 502 | Stay Set complete with stay wire (7/4.00 mm) as per IS:2141:1992 & Clamps |
| 503 | Earthing Set complete with Earthing Electrode of GI Pipe, 40mm Dia, 2.5 to 3.00 Mtr. Long and G.I. wire 8 SWG (4mm, 55Kgf/Sqmm hard quality) |