| 1 | Removal of blokage/choke up obstructing the flow of sewage line (SGSW/DWC SN8 pipe) by rodding with rods wood/kamathis/choke remover and making the flow continuous for bore of pipe not exc 100mm complete all as specified and directed by Engineer-In-Charge. |
| 2 | Removal of blokage/choke up obstructing the flow of sewage(SGSW/DWC-SN8/RCC pipe)line by rodding with rods wood/kamathis/choke remover and making the flow continuous for bore of pipe 150mm complete all as specified and directed by Engineer-In-Charge. |
| 3 | Desilting of man hole exc 1.0 m butn exc 1.50m depth with dewatering including carriage of sludge from tank and disposed to a distance exc 100m and not exc 500m complete all as specified and directed by Engineer-In-Charge. |
| 4 | Desilting of man hole exc 1.50 m but not exc 4.5m depth with dewatering including carriage of sludge from tank and disposed to a distance exc 100m and not exc 500m complete all as specified and directed by Engineer-In-Charge. |
| 5 | Desilting of septic tankfor 100 users with dewatering including carriage of sludge from tank and disposed to a distance exc 100m and not exc 500m complete all as specified and directed by Engineer-In-Charge. |
| 6 | Desilting of septic tankfor 25 users with dewatering including carriage of sludge from tank and disposed to a distance exc 100m and not exc 500m complete all as specified and directed by Engineer-In-Charge. |
| 7 | Desilting of septic tankfor 50 users with dewatering including carriage of sludge from tank and disposed to a distance exc 100m and not exc 500m complete all as specified and directed by Engineer-In-Charge. |
| 8 | Removing blockage pipe line rejoining the existing line with new SGSWpipes 100/150mm bore complete for only 01 pipe piece standard length including necessary PCC packing under & haunching at sides (1:4:8) type D2 etc including earth work complete all as specified and directed by Engineer-In-Charge. |
| 9 | Desilting of house chamber (First manhole) any depth but less than 1.0m and stacking the sit at the distance exc 100m but not exc 250m complete all asand directed by Engineer-In-Charge. |
| 10 | Removing blockage fromwater closet, floor or gully or Nahani Traps and bends etc by rodding thoroughly and pouring water under pressure and cleaning, clearing the drainage to efficient and smooth flow of sludge/waste water complete as specified and directed. |
| 11 | Repair of leakage/seepage from the Nahani Trap/floor trap of kitchen/bathroom/washbasin of the upper quarter, in any position at any height, complete including change of floor trap, PVC horizontal pipe embedded in floor in bathroom or kitchen making good to the damage portion of all flooring, laying and matching of tiles in existing flooring, complete all as specified and directed by Engineer -in -Charge. |
| 12 | Repair of leakage/seepage from the wall / door bend/door tree/ ‘Y’ Junction / ‘T’ junction of soil pipe / waste pine / vent pipe of kitchen bathroom / WC of the upper Qtr or at the ground floor Qtr including change of any damage soil waste pipes or fittings of any shape, specification and size, making good to the damage portion of wall with brick work in cement mortar 1:6 or cement concrete 1:2:4 and plastering to wall in CM 1:4 and matching to existing wall complete to avoid the leakage seepage at the site of work as directed and specified by Engineer -in -Charge. |
| 13 | M&L for excavatingand breaking existing SGSW gully trapand fixing of new gully trap 150x150mm complete with PCC (1:4:8) type D2 100mm thick in foundation and making good to match existing surface complete all as specified and directed. |
| 14 | Taking down C Ipipe including fittings of 100mm bore complete all as specified and directed. |
| 15 | Taking down C Ipipe including fittings of 75 mm bore complete all as specified and directed. |
| 16 | S&F 100 mm cast iron sand cast soil waist and vent pipe in any length with or without ears with cement joints fixed complete all as specified and directed. |
| 17 | S&F 75 mm cast ironsand cast soil waist and vent pipe in any length with or without ears with cement joints fixed complete all as specified and directed. |
| 18 | S&F 100 mm cast iron bends any radius complete all as specified and directed. |
| 19 | S&F 75 mm cast iron bends any radius complete all as specified and directed. |
| 20 | S&F 100 mm cast iron cowl complete all as specified and directed. |
| 21 | S&F 75 mm cast iron cowl complete all as specified and directed. |
| 22 | S&F pre-cast manhole covers of RCC (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) with two numbers of handle of MS round bar 12 mm dia and 150 mm longfor manhole cover slab including placking in position and set in CM 1:6 for size 600x900x100mm of manhole complete all as specified and directed. |
| 23 | All as per item No 22 here in before but size 450x750x75mm. |
| 24 | All as per item No 22 here in before but size 300x300x75mm. |
| 25 | M&L MS steel TMT bars 10mm dia and over, cut to length, bent to shape required including cranking bending spirally for hooping for column, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed. |
| 26 | Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided complete all as specified and directed. |
| 27 | M&L for providing precast reinforced cement concrete type B1 1:2:4(using 20mm graded crushed stone aggregate) set in cement mortar 1:4 as in cover slabs (for manholes) complete all as specified and directed.Note:- Reinforcement shall be measured and paid separately. |
| 28 | Excavation in trenches not exc.1.50 m wide and not exc 1.5m deep for laying of sewer pipe and manhole etc and getting out in soft/loose soil complete all as specified and directed. |
| 29 | Demolition and breaking up drain pipe SWG pipe set in cement mortar including haunching and bed concrete for 150mm dia SWG pipe complete all as specified and directed. |
| 30 | Dismantling of RCC drain pipe 200mm dia bore jointed in cement mortar and taking out of trenches complete all as specified and directed. |
| 31 | M&L for 150 mm bore SWG drain pipe, of grade \"A\" laid in trenches and jointed complete all as specified and directed. |
| 32 | M&L reinforced concrete pipe NP2 200mm dia laid and jointed complete with collars, jointed with cement mortar complete all as specified and directed. |
| 33 | M&Lfor beding to drain pipesincluding packing under,andhunching in PCC 1:3:6 type C2 using 40 mm graded aggregate against the side of SWG/RCC pipes after they are laid and tested for150 mm dia bore pipe complete all as specified and directed. |
| 34 | All as per item No 33 here in before but 200 mm dia pipe. |
| 35 | Returning filling in soft/loose soil including spreading, levelling, watering and well ramming in layers not exc. 25cm thick complete all as specified and directed. |
| 36 | Removing excavated materials not exc. 50m and depositing where directed complete all as specified and directed. |
| 37 | M&L for cutting in to existing manholes for connecting new drain making good to pipes and rendering cutting out existing benching for and forming bracketschannel (1/2 round or 3/4 section) in cement concrete (1:2:4) type B-1 and reforming benching as required for 150/200 mm bore pipe complete all as specified and directed. |
| 38 | Demolition of brick masonary built in cement mortar in any ratio complete all as specified and directed. |
| 39 | M&L old size Brickwork with fly ash, straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and directed. |
| 40 | Taking down cement plaster on brick or stone wall or concrete surfaces complete all as specified and directed by Engr-in-charge. |
| 41 | M&L for rendering 15 mm thick on fair faces of concrete or block masonary CM 1:6 finished even and smooth (without using extra cement) of wall complete all as specified and directed. |
| 42 | M&L for rendering 10 mm thick on fail faces of concrete or block masonary CM 1:4 finished even and smooth (without using extra cement) of wall complete all as specified and directed. |
| 43 | M&L for rendering 10 mm thick CM 1:6 and setting coat 10 mm thick CM 1:4 finished even and smooth (without using extra cement) in wall including scaffolding complete all as specified and directed. |
| 44 | All as per item No 43 here in before but 5 mm thick in ceiling surfaces CM 1:4 complete all as specified and directed. |
| 45 | S&F of wire netting of galvanised steel wire 1.40mm dia with 20mm size of mess fixed with tinned tacks of wire staples. |
| 46 | M&L for preparation ofnew plastered surface of wall and applying two coats of distemper oil emulsion over a coat of primer over a sufficent coat of wall care putty complete all as specified and directed. |
| 47 | M&L for preparation of new plastered surface of ceiling and applying three coats of white wash complete all as specified and directed. |
| 48 | M&L preparation of new surfaces of wall and applying two coats of cement base paint complete all as specified and directed. |
| 49 | M & L for applying Twocoats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces all as specified and directed. |
| 50 | M & L for preparation of old decorated surfaces of ceiling and applying one coat of white wash complete all as specified and directed. |
| 51 | M & L for complete removal of existing treatment from old wall surfaces and applying two coats of oil bound distemper over 3mm thick of birla wall putty complete all as specified and directed.aint complete all as specified and directed. |
| 52 | M & L for complete removal of existing treatment of wall surfaces and applying Twoor more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces all as specified and directed. |
| 53 | Taking down PVC pipe (SWR) 110mm dia bore and connection complete all as specified and directed. |
| 54 | Taking down PVC pipe (SWR) 75 mm dia bore and connection complete all as specified and directed. |
| 55 | S&F 75 mm dia bore pipe (SWR) single socket in any length rubber joints fixed to wall complete all as specified and directed. |
| 56 | S&F 110 mm dia bore pipe (SWR) single socket in any length rubber joints fixed to wall complete all as specified and directed. |
| 57 | S & F PVC (SWR) bends (any radius) suitable for 110mm bore pipe complete all as specified and directed by Engineer-in-Charge. |
| 58 | S & F PVC (SWR) bends (any radius) suitable for 75mm bore pipe complete all as specified and directed by Engineer-in-Charge. |
| 59 | S&F in repair 75mm dia of outlet PVC (SWR) floor trap plain with grating including jointing with solvent cement complete all as specified and directed. |
| 60 | Dismantling of RCC fencing post and struts including taking out embeded portion for post embedded in natural ground making good the disturbed portion to requried shape & size for placing new fencing post including any excavation requried complete all as specified and directed. |
| 61 | Dismantling of fencing wire mesh of any type complete all as specified and directed. |
| 62 | Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out in soft/loose soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm all as specified and directed. |
| 63 | M&L Cement concrete 1:3:6 Type C-2 (using 40mm graded stone aggregate) as in post hole complete all as specified and directed. |
| 64 | Supply only Chain link fencing any size or type complete all as specified and directed. |
| 65 | Fixing only Chain link fencing including line wires, any mesh, size and type to any standards, rails straining bolts, etc. including provision of binding wire complete all as specified and directed. |
| 66 | S&F mild steel section and embedding in concrete, posts or struts in fencing including cutting tops to shape as directed drilling holes notching for wire etc. flat iron fillets (for securing wire mesh) including all necessary drilling, bolting etc and similar work conforming to Fe-290 Gde 165 complete all as specified and directed. |
| 67 | M & L for preparation of new steel surfaces of any description, over 10cm in width or girth, not otherwise described including preparation, priming with zinc chromate and two coat of synthetic enamel paint complete all as specified and directed by Engineer-in-Charge. |
| 68 | S&F mild steel screw bolt (machine made) with hexagonal or square heads at one end and screwed the other each screwed end to be fitted with washersand one hexagonal nut but length of bolt exc. 5cm and n. exc. 10cm long and bolt one side embedded in concrete posts etc complete to fix fencing wire dia of shank 11 to 15 mm complete all as specified and directed. |
| 69 | S&F mild steel bars for straightening / ties bars for chain link fencing 10mm dia of over, cut to length and tying with MS wire n. exc. 0.6mm complete all as specified and directed. |
| 70 | M & L for preparation of new steel surfaces plain or moulded, n exc 10cm width or girth when unconnected with other painting or when painted in a different tint including preparation, priming with zinc chromate and two coat of synthetic enamel paint complete all as specified and directed by Engineer-in-Charge. |
| 71 | Dismantling wrought iron or mild steel work of any discription etc. complete all as specified and directed. |
| 72 | Dismantling of punched type concertina coil any type or size complete all as specified and directed. |
| 73 | Taking down galvanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining etc. (each line wire to be measured) complete all as specified and as directed. |
| 74 | M & L for preparation of old steel surfaces of any description, over 10cm in width or girth, not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed by Engineer-in-Charge. |
| 75 | Fixing only galvanized steel punched type concertina coil of loop dia 1050mm(dia of coil when unstreched) fixed to angle post strut with 3.15 mm dia galvanised MS plain wire complete all as specified and directed. |
| 76 | Supply only galvanised steel punched type concertina coil of 1050mm dia (dia of coil when unstretched with Nos. of circles 50, Nos. of clips 230 with weight 15.60 kg/ coil and recommended and average coverage area is 6 RM/ coil) and fixed to angle iron post/ struts with 3.15mm dia GI wire complete all as specified and as directed. |
| 77 | S&F galvanised, 2 strand, steel barbed wire, 2.24 mm dia, barbed with 2 mm dia barbs at 75mm spacing and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. complete all as specified and directed. Note:- Each line wire shall be measured. |
| 78 | Dismantling of stone slab and tiles of any description or thickness in floors, aprons etc. laid and bedded and pointed in any mortar and rubbish off the premises complete all as specified and as directed by the Engineer-in-Charge. |
| 79 | Demolition of cement concrete (unreinforced) in ground floors and pavings n.exc 15 cm thickness (below or above G.L) complete all as specified and directed. |
| 80 | M&L forprecast cement concrete 1:2:4 type B-0 (using 12.5mm and below stone aggregate ) in kerb stone factory made as approved by GE with plaine fair faces including champhering, weathering etc complete with joint to match in CM 1:6 complete all as specified and directed. |
| 81 | M&L for providing 75 mm thick cement concrete 1:4:8 type D-2 (using 40mm graded aggregate) as in sub base complete all as specified and directed. |
| 82 | M&L forMachine pressed precast concrete interlocking paver block any shape and size with grey cement and pigment confirming to IS 15658-2006 of 60 mm thickness M-35 Grade over sand cushion complete all as specified and directe. (Note- Sand will be measured and paid separately) |
| 83 | M&L 25mm thick sand filling (sand cushioning) under path for layersinterlocking tiles complete all as specified and directed. |
| 84 | Dismantling of floor hearth or wall tilling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed. |
| 85 | M&L for 25 mm thick PCC (1:2:4) type B-1 (using 12.5mm graded stone aggregate) as in levelling course complete all as specified and directed. |
| 86 | M&L for 15 mm thick screed bed or bedding layer of morter for laying floor finishes CM 1:6 complete all as specified and as directed. |
| 87 | M&L for Non- skid Ceramic coloured joint free tiles 7 to 8mm thick (square/Rectangular) area of each tiles exceeding 0.06 Sqm but not exceeding 0.11 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed. |
| 88 | M&L for Non- skid Ceramic coloured joint free tiles 7 to 8mm thick (square/Rectangular) area of each tiles exceeding 0.18 Sqm but not exceeding 0.38 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed. |
| 89 | M&L for glazed ceramic coloured digital tiles 450x350mm x 7mm/ 350x250x7mm thick in vertical surface etc set and jointed in neat cement slurry and pointed in white or coloured cement to match including backing coat of CM 1:4, 10mm thick etc complete all as specified and as directed. |
| 90 | M&L for Endura glazed tiles 8-10 mm thick light/ dark shade (square) area of each tiles 400mm x 400mm, in floor etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed. |
| 91 | M & Lfor Chequred cement concrete tiles 30cm x 30cm x 25mm thick with grey cement and pigment, set jointed and pointed in neat cement slurry in floors complete all as specified as directed. |
| 92 | S&F in repair Vitreous china wash basin with pedestalflat back size 630X450 mm white, excluding taps, waste ,chain and plug and chain porcelain stopper but including brackets cutting for and pinning in ends of brackets or erecting stand complete all as specified and as directed. |
| 93 | Supply and fixing in repair PVC valveless, syphonicaction type flushing cistern, 10 ltr capacity, low level, white, with inlet, ball valve, float and handleincluding bracket, complete all as specified and directed. |
| 94 | S&F in repair vitreous china wash down water closet panpedestal pattern, white excluding fixing cistern and flush pipe trap front or back inlet including seat cover of any pattern and health faucet (ABS) with rubit cleaning system 1.25 m long, PVC flexible tubeand ABS wall hook complete all as specified and as directed. |
| 95 | S&F in repair vitreous China squatting pan, ‘Orissa’ pattern, size 580 x 440 mm white, with integral foot rests including connection to trap & flushing pipe complete all as specified and directed by Engineer-in-Charge. |
| 96 | S&F in repair PVC water connection 600 mm long to wash basin of 15mm dia including PTMT nuts and washers complete all as specified and as directed. |
| 97 | Taking up or down 15mm dia CPVC/steel tubing and connection including cleaning for refixing or removal to store complete all as specified and as directed. |
| 98 | S&F of 16mm dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling complete all as specified.Supply including all PP-R plain & brass threated polypropylene random fittings fixed complete all as specified and directed. |
| 99 | M&L for cutting chases, in brick wall pinning in, making good to facing where required and pointing in cement mortor 1:3 to ends or edges of andings steps, cills sunshades, shelves lintels etc and cutting chases for concealed water tubing and making good cutting not exc 10cm grith complete all as specified and as directed. |
| 100 | S&F in repair 75 mm dia outlet CI nahani trap plain with S/S grating including jointing with solvent cement complete all as specified and directed. |
| 101 | S&F in repair brass chromium platedtubular towel rail 20 mm dia \"D\" type 60 cm long including brackets/flanges completed all as specified and directed. |
| 102 | S&F in repair Health faucet (ABS) with rubit cleaning system 1.25m long PVC flexible tube & ABS wall hook complete all as specified and as directed. |
| 103 | S & F in repair SS jet with inlet pipe suaitable for EWC complete all as specified and as directed. |
| 104 | S&F in repair brass chromium plated shower roses 125 mm size with swivel joints, any size including fixing to steel pipe or union complete all as specified and as directed. |
| 105 | S&F in repair 15 mm bore pillar taps fancy type, cast copper alloy, with capstain head, chromium plated, screwed down, high pressure, with or without letters cold or hot with long shank and fly nuts screwed for iron pipe and fixed complete all as specified and as directed. |
| 106 | S&F in repair Fancy type CP bib taps 15 mm dia ,chromium plated cast copper alloy withhalf turn type capstan heads, screwed down screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed. |
| 107 | S&F in repair Fancy type CP stop/angular cock 15mm dia cast copper alloy, chromium plated fency type screwed down high pressure withhalf turn type capstan heads, screwed both end for iron pipe or for unions and fixed complete all as specified and directed |
| 108 | S&F in repairFancy type CP stop valve 15mm dia cast copper alloy, chromium plated fency type with long shank and cup (concealed type)screwed down high pressure with half turn type capstan heads, screwed both end for iron pipe or for unions and fixed complete all as specified and directed |
| 109 | M&L for taking down fencing post, minor repair i.e welding, straighting, angle iron as required, PCC and fixing in same position complete all as specified and directed |
| 110 | M&L for taking down old chain link fencing and refixing in same position including replacement of all old unserviceable nuts & bolts etc complete all as specified and directed |
| 111 | Taking down carefully any type of steel rolling shutters of size exc 5 Sqm but n. exc 15 Sqm each, inspecting / notifying the defective springs, bearings, shaft, side guides, Gear box etc including greasing and replacement of unserviceable / defective parts and re fixing in the same position and releasing the tension in the springs, lowering complete all as specified and directed by Engineer-in-Charge. |
| 112 | Taking down of hood over of rolling shutter of any type area n exc 25 Sqm of each and greasing to all parts of rolling shutter after replacement of following unserviceable parts as required for smooth function of rolling shutter and refixing properly including bracket:- |
| 113 | (a) Shaft 50mm mild steel pipe |
| 114 | (b) Gear Box |
| 115 | (c) Helical spring 600mm long |
| 116 | (d) Lath patty (strips) of 75mm wide & 1.20mm thick MS plate |
| 117 | (e) Ball bearing for 50mm dia pipe |
| 118 | (f) Crancked wheel |
| 119 | (g) Safety lever locks mild steel with 4 levers for rolling |