| 1 | Dismantling floor, hearth or wall tiling/ Paver block /chequered tiles including cement mortar bedding (but not backing) and rubbish off the premises, complete all as specified & directed. |
| 2 | Demolition of cement concrete (unreinforced) in ground floors and paving not exc 15cm thickness (below or above ground level) and removal exc 250m but not exc 500 mtr and depositing, complete all as specified and directed by Engineer-in-charge |
| 3 | Demolition of plain cement concrete of any description and in any position not otherwise specifically provided for in this Schedule and removal exc 250m but not exc 500 mtr and depositing, complete all as specified and directed. |
| 4 | M&L for hardcore of broken stone or boulder of gauge not exceeding 63mmdeposited spread and levelled in layers not exceeding 15mm thick, watered and rammed to a true surface as in sub base of floor complete all as specified and as directed. |
| 5 | M & L for 75mm thick PCC 1:4:8 Type D2 as in sub base, all as specified & directed. |
| 6 | M & L for 100 mm thick PCC 1:2:4 Type B1using 20 mm graded stone aggregateas in hard standing, finishing surface even and smooth without using extra cement, & making impression of expanded metal whilest the concrete is green. |
| 7 | M & L for Forming 12mm thick expansion joint filled with preformed bitumious filler and top 30mm primed and sealed with sealing compund grade \"B\", for 100 mm thick concrete slab all as specified & directed. |
| 8 | M&L for 50 mm thick PCC (1:3:6) type C2 using 20 mm graded crushed stone aggregate as in plinth protection, surface finished fair and even, laid to slope of 1:30 in alternative bays not exceeding 3 meter in length, complete all as specified and directed. |
| 9 | M&L for cement concrete (1:3:6) type C2 using 20 mm graded crushed stone aggregate as in surface channels and drains and benching including finishing the top of benching even and smooth using extra cement.Note : Forming fair finished channel for drain using extra cement shall be measured and paid for separately. |
| 10 | Add extra for forming fair finished drain or channel of 30 cm inner girth in cement concrete using extra cement, incl forms, moulds etc complete. |
| 11 | Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand; complete all as specified and as directed.Make:- Ultra Tiles Pvt Ltd, Anjali Tiles,Terra Firma, Nitco |
| 12 | M&L for PCC 1:2:4 type B0 using 12.5mm graded stone aggregate as in sidesfilling and mass concrete, coping/ benching complete all as specified and directed by Engr-in-charge. |
| 13 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete all as specified and as directed. |
| 14 | M & L for preparation of new concrete surface by rubbing downand applying two coats of synthetic enamel paint over a coat of primer over 10cm girth or width, complete all as specified and as directed. |
| 15 | M & L for preparation of old plastered/ concrete surfaceby rubbing downof any description over 10 cm in width or girth and applying one coat of synthetic enamel paint of approved tint, complete all as specified & directed. |
| 16 | M&L for Pre-polished chequered cement concrete tiles with grey cement & pigment of size 30cmx30cmx22 to 25mm thick set & jointedwith cement slurry over & including 15mm thick screed bed in CM 1:6. all as specified & directed.Make :- Ultra, Bansal, Nitco, Anjali, Multiwyn |
| 17 | M&L for Screed bed or bedding layer of mortar 20 mm thick bedding layer of cement sand mortar (1:4)and pointed with grey cement complete all as specified and as directed by Engineer-in-Charge. |
| 18 | M&L for Screed bed or bedding layer of mortar 10 mm thick bedding layer of cement sand mortar (1:3)and pointed with grey cement complete all as specified and as directed by Engineer-in-Charge. |
| 19 | Demolition of brickwork or stone/ boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc but excluding ashlar facings, dressed stone work and precast concrete articles, complete all as specified & directed. |
| 20 | M&L for brick work with old size sub-class ‘B’ bricks, straight or curved on plan exc 6.00 metre mean radius, built in cement mortar (1:6), complete all as specified & directed. |
| 21 | Taking down cement plaster on brick or concrete or stone wall/ drain surfaces including raking out joints hacking for key scrubbing down with water etc complete all as specified and as directed by Engineer-in-charge. |
| 22 | M&L for rendering 15mm thick in cement mortar (1:6) onsurfaces fair face of brick work of walls, finished even & smooth without using extra cement, complete all as specified & directed. |
| 23 | M&L for rendering 15 mm thick in cement mortar(1:4) on other than fair face of brick work of walls, finished even & smooth without using extra cement complete all as directed. |
| 24 | Supply only integral water proofing compound (ISI marked) complete all as specified & directed. |
| 25 | M&L for preparation of newly plastered surfaces of wall & applying two coats of cement base paint of approved shade/tintover a coat of chalk whiting, complete all as specified & directed. |
| 26 | M&L for preparation of old decorated plastered surfaces of walls and applying one coat of cement base paint of approved shade/ tint, complete all as specified & directed. |
| 27 | M&L for preparation of plastered surface of walls/ roof/ floor by brooming down, steel wire brushing, scrapping down, smoke soot, moulds, moss & efflorescent salts and applying two coats of weather proof Acrylic emulsion paint (exterior grade) of Ist quality (Apex ultima of Asian paint or equivalent from Nerolec/Berger) in camouflage pattern over and includingone coat of primer complete, all as directed by Engr-in-charge. Note- Primer shall be applied after complete removal to existing treatement from old plastered/ concrete surface. |
| 28 | Demolition of cement concrete (reinforced)of any description and in any position not otherwise specifically provided for (reinforcement cut as required to facilitate demolition)complete all as specified and as directed. |
| 29 | Dismantling wrought iron or mild steel work of any dscription not otherwise provided for completeall as specified anddirected. |
| 30 | M&L for Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick flat rough finished surfaces of concrete (Horizontal or sloping) complete all as specifed and as directed. |
| 31 | M&L for TMT Bars 10 mm dia and over cut to length bent to shape reqiured, incl cranking, bending spirraly for hooping for columns, hooking ends and binding with and incl mild steel wire (annealed) not less than 0.9m dia or securing with clips. |
| 32 | M&L for reinforced cement concrete (1:2:4) using 20mm stone aggregate for Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like as specified and as directed. |
| 33 | Dismantling plain or corrugated steel sheeting, any gauge, thickness as in roof coverings etc including ridges, complete all as specified & directed. |
| 34 | Dismantling structural steel work including doors, gates/ gratings/ grills of any dscription not otherwise provided for completeall as specified and directed. |
| 35 | S&F in repairs steel work in tubular trusses including special shaped washer etc complete using ERW or induction butt welded tubes conforming to IS 1161-1998 grade st-240 |
| 36 | M&L for preparation of new steel and iron surfaces of any description over 10 cm in width or girth and applying two coats of synthetic enamelpaint of approved tint over a red oxide primer complete all as specified & directed. |
| 37 | M&L for preparation of old painted steel and iron surfaces of any description not exceeding 10 cm in width or girth and applying one coat of synthetic enamel paint all as specified. |
| 38 | S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/ cladding to wall, fixed with self taping screws as specified. |
| 39 | S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/ cladding to wall, fixed with self taping screws as specified. |