Jjm Water Supply Scheme At Piloda Khu. Tal Yawal Dist. Jalgaon- 1 TUBEWELLItem.No.1 :-Transportation charges for drilling machinery from one site to another site, necessary expenditure for making approach road etc. included in this job ……etc complete 2 Item.No.2:-Drilling of 150 to 300mm diameter naked tube wells perfectly vertical in all strata at ground levels including machinery fuel,oil,bentanite,clay etc. depth of tube wells shown in the schedule is tentative and well be finalised as per detailed certificate of G.S.D.A. 3 Item.No.3 -Providing and supplying,lowering &fixing in standard lengths ISI mark rigid unplasticised PVC pipes suitable for potable water with solvent cement joints including cost of couplers, as per IS specification no. 4985 / 1988 excluding GST levied by GOI and GOM in all respect......etc. complete.a)PVC 180 mm dia. 6 Kg/cm^2Plain casing PVC pipe (1098+109) 4 b)PVC 180 mm dia. 6 Kg/cm^2 Slotted casing PVC pipe (1098+218) 5 Item.No.4 :- Supplying and transporting and placing gravel packing of size 3/8 to 1/2 only including stacking , sorting washing and placing gravel 3/4 to1/2 inchonly 6 Item.No.5 :- Development of tube wells by suitable air compressor of 600 cfm/100 PSI cap at site for period of at least 36 hours by high velocity, jeting and back washing etc complete 7 Item.No.6 :- Supplying and fitting suitable Bellplug of 200 mm dia.at bottom of casing pipe…..etc complete 8 Item.No.7 :- Supplying and fitting MS heavy duty clamps …..etc complete 9 Item.No.8 :-Providing and fixing two wooden sleeper 300mm x150 mm x1000 mm of jungle wood for supporting clamp. 10 Item.No.9:-Cleaning the site, refilling by excavated material and levelling as directed after completion of work. 11 Item.No.10:- Carrying out yield testing by Air lift method and 900 notch method for 3 hours and giving certificate mentioning the drawdown levels 12 Item.No.11 :- Providing and laying in situ Cement concrete of trap/granite/quartzite/ gneiss metal for PCC M-100 work below foundation and footing including normal dewatering,plywoodform work, compaction, finishing and curing, etc, complete. 13 SWITCH ROOMExcavation for foundation / pipe trenches in earth, soils of all types, sand, gravel and soft murum, including removing the excavated material upto a distace of 50 M and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundationetc complete. 14 Providing and laying in situ cement concrete M-10 /1:3:6 of trap/granite/quartzite/gneiss metal for foundation and bedding including bailing-out water manually formwork, compacting,cover-ing newly laid concrete by gunny bag, plastic or tarpaulin, curing etc complete. 15 Item No 1 Providing and laying in situ Cement concrete of trap/granite/quartzite/ gneiss metal for PCC work below foundation and footing including normal dewatering,plywood form work, compaction, finishing and curing, etc, complete.PCC M150 16 Providing and laying in situ Cement concrete of trap/granite/quartzite/ gneiss metal for RCC work in foundation like raft, grillage, strip foundation and footing of RCC columns and steel stanchions including normal dewatering,plywood form work, compaction, finishing and curing, etc, complete. (By weigh batching and mix design for M-250 and M-300 only. Use of L & T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.)RCC M 250 for Footing 17 Providing and casting in situ Cement Concrete of trap/granite/quartzite/ gneiss metal of approved quality for RCC work as per detailed drawings and designs or as directed by Engineer-in-charge including normal dewatering, plywood form work,bully/steel prop ups, compaction, finishing the formed surfaces with CM 1:3 of sufficient minimum thickness if special finish is to be provided and curing, etc. complete. (By weigh batching and mix design for M-250 and M-300 only. Use of L&T, A.C. C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted )RCC M 250 for column 18 Providing and casting in situ C. C. of trap / granite / quartzite/ gneiss metal of approved quality for RCC works as per detailed drawings and designs or as directed by Engineer-in-charge including normal dewatering, ,plywood form work,bully/steel prop ups compaction, finishingthe formed surfaces with C. M. 1:3 of sufficient minimum thickness to give a smooth and even surface wherever nesessary or roughening if special finish is to be provided and curing, etc. complete. (By weigh batching and mix design for M-250 and M-300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.)RCC M 250 Beams, Lintels 19 Providing and casting in situ C. C. of trap/granite/quartzite/ gneiss metal of approved quality for RCC work as per detailed drawings and designs or as directed by Engineer-in-charge including normal dewatering, plywood form work,bully/steel prop ups, compaction, finishing the formed surfaces with CM 1:3 of sufficient minimum thickness to give a smooth and even surface wherever necessary or roughening if special finssh is to be provided and curing, etc. complete. (By weigh batching and mix design for M-250 and M-300 only. Use fo L&T, A.C. C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted .)RCC M 200Slabs 20 Filling in plinth and floors / trenches with contractor’s murum for bedding in 15cm to 20cm layers including watering and compaction complete. 21 Providing Bricks masonry in cement mortar 1:6 using Second class burnt bricks in superstructure including striking joints, raking out joints, watering and scaffolding complete. For Plinth 22 For Superstructure 23 Providing and fixing in position steel bar reinforcement of various diameters for RCC piles, caps, footings, foundation, slabs, beams, columns, canopies, staircases. newels, chajjas, lintels, pardies, copings, fins, arches, etc. as per detailed designs, drawings and schedules; including cutting, bending, hookingthe bars, binding with wires or tack welding and supporting as required, etc. complete.(including cost of binding wire) 24 Providing rough cast cement plaster externally in two coats to concrete,brick or stone masonry surfaces inall positions with base coat of 12to15mm thick in C.M.1:4 and rough cast treatment 12mm thick in proportion 1:1 1/2:3 including scaffolding and fourteen days curing complete.Bd.L.8 Page Number 370 25 Providing internal cement plaster 20mm. thick in single coats in cement mortar 1:4 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curingcomplete. Spec. No. : Bd.L.4 Page No. 368 26 Providing and fixing solid core flush door commercial in single leaf 35mm thick without ventilator commercial type of exterior grade as per detailed drawing including non teak seasoned wood door frame 60mm x 100mm with wrought iron hold fast, on both sides and finishing with oil paint three coats complete.As directed by Engineer in charge.a) With Aluminum oxidized fixtures & fastening 27 Providing and fixing steel window of various sizes as per detailed drawings fabricated from IS standard sections without hot dip zinc coating without / with ventilator including fabrication, glazing with non-acentinic / plain / obscured glass panels of approved type and quality, all fixtures and fastening without teak wood boxing, and architraves and finishing with one coat of primer complete with guard bars 12mm square bar 10cm center to center.Bd.T.53 PageNo.509. 28 Providing and laying polished Shahabad Stoneflooring 25mm to 30mm thick and of required width in plain / diamond pattern on a bed of 1:6 C.M. including cement float, filling joints, with neat cement slurry, curing, polishing and cleaning complete. Spec. No. : Bd.M.3 Page No. 380 29 Providing and applying white-wash in two coats on old/ new plas-tered or masonry surfaces and asbestos cement sheets including scaffolding and preparing the surface by brushing &brooming down complete. 30 Providing and applying two coats Apex Ultima Puranature Anti-Pollution Or equivalent approved brand, paint should decomposes organic substances and inorganic gases(NOx, VOC‘s, CO, SOx, formaldehydes, etc.) in presence of natural or artificial light. It contains Graphene and nanoparticles of titanium oxide. and Absorbs CO2 (4.8 Kilogram/15 l). plaster crack should be filled by Acrylic base Crack seal/Textured Crack filler, Paint has to applied on one coat of Apex Ultima Puranature Anti-Pollution Primer or Equivalent. Warranty Should be given by the Manufaturer The work should be done by the Manufacturer Recommended applicator and he should be able to furnish stage wise onsite technical reports from the concerned company technologist. 31 Providing & applying washable oil-bound distemper of approved colour and shade to old &new surfaces in two coats including scaffolding, preparing the surfaces. (excluding the primer coat.) complete. 32 PUMPING MACHINARYItem No. 1:- Providing erecting and giving test of submersible pump set confirming to IS. 8034 and motor confirming to I.S. 9283 with water proof binding pump shall be suitable for various delivery head and discharge with stainless steel shaft motor suitable for working on 41510% 3 ph 50 Hz A.C. supply with cable gurad thrust carbon fiber bearing to with stand entire hydrulic thrust .the pump set shall be suitable for direct coupling with suitable saction stainer pump should have suitable discharge outlet as per manufacture design antithrust stream non retun valve shall be provided with the pump 3 m submersible copper conductor cable in single/ double run 2 pair of erection clamp 65 mm width 10 mm thick shall be provided with each pumpSubmersible pump 7.5 HP with supply & errection 33 Submersible pump 7.5 HP only supply 34 Item No. 2:- Providing erecting commissinory L.T. panel board with all required accessories for the pump in above item No. 1.. etc.complete 35 Item No. 3: - Supplying and erecting Flat flexible submersible cable with copper conductor PVC insulated and PVC sheathred 1 x 3 x 4 sqm 36 Item No 3B) Providing and erecting P.V.C. armoud cable 1100V grade with ISI mark3.5 core Solid / standard aluminium conductor with 6 mm thick 25 mm width m.s.. Spacer with G.I. Earth wire 6 Sq. mm complete erected onwall / on Pole with 25 X 3mm M.S. Clamp in provided trench in an approved manner4 Core 10 Sq. mm 37 Item No. 4:- Supplying and erecting G.I. Pipe Bin position for suction and delivery for submersible pump including pumbing with socket and necessary material50 mm dia G.I, M Class 38 Item No. 5:- Providing and erecting presure gauge of required capacity complete with syptio tube isolating cock suitable for 12 mm dia G.I. Pipe pressure gauge shall be installed as directed with tapping on rising main100 mm. Dia 39 Item No. 6:- Providing ISI mark G.I. Pipe of following class and dia including all local and central taxs octrai inspection charges transporatation to store etc… complete medium15 mm. Medium Providing L.L joint 40 Item No. 7 :- Providing and supplying G.I. special at site including all taxes (central & Local)RailwayFright Insurances on loading from Railway wagon Loading Truck Transport to store/site unloading etc.. Comp. As directed by Engineer in Charge 41 Item No. 8:- Providing and supplying ISI mark C.I. D/F reflux valve (non return valves) of following dia including all taxes (central and local) railway freight inspection charges loading unloading from railway wagon transportation upto departement store etc. complete IS 5312 (1984)50 mm dia P.N. 1with fixing ( 3319+833 ) 42 Item No. 9:- Providing and supplying ISI mark C.I.D.F sluice valve of following dia including all taxes (central and local railway freight inspection entries unloading from railway wagon loading into truck transportation upto departmental store/site unloading stacking etc. complete.50mm dia P.N. 1with fixing on delivery side( 4198+833) 43 Item No. 10 :- Providing and making flaged Joint to flange, C.I. Pipes / M.I. Pipes and specials of all classing including cost of jointing material rubber packing nut bolts labour charges hydrulic testing etc. complete80 mm dia Joint 44 Item No. 11 :- Supplying and erecting Galvanized cast iron earth plate 60 X 60 X 0.6 cm buried specially preposed earth pt[top edge of plate 1.5 m below ground refilling with 30 kg chorcoal and salt in alleviate layers neccessory length of double G.I. earth strip connected to the plate G.I. nuts bolt 12 mm dia iwth Bituminous compound and connected to nearest switch gear with end socket as per directed supplying and erecting 19m dia ventical G.I. pipe 1.5 m long with funner and mesh at top included in the scope of work. 45 Item No. 12:- Providing and supplying internal elactrification to switch room etc. comp. Rate analysis attached 46 Item No. 13:- Providing and fixing wall mounting type name board duly painted all details of pumping machinery make, model frame no. DR no. Date of installation commissioning manufacture year agoncy name aggrement no details of G.I. Shal 18 gauge of required size duly painted with red oxide and enamus paint for dispaying the above details board shall be provided with suitable T.W. bottom back side name board 47 Item No. 14:- Providing and Tool kit. 48 Item No. 15:- ProvidingChain Pully Block 1 MT Tone 49 RAISING MAINItem No. 1:- Providing and supplying in standard lengths Polyethelene Pipes, confirming to IS 4984 / 14151 / 12786 / 13488 with nesessary jointing material like mechanical connector i. e. thread / insert joint / quick release coupler joint / compression fitting joint or flanged joint excluding coupler/specials, including transportation and freight charges, inspection charges, loading / unloading charges, conveyance to the departmental stores & stacking the same in closed shade duly protecting from sunrays & rains, excluding GST levied by GI & GOM in all respect etc. complete.90 mm HDPE 6 kg pipe 50 Providing at site of works HDPE specials suitable for above pipes including cost of all taxes, freight charges, octroi, loading, unloading and conveyance to Deptt.store etc. complete. 51 Providing and supplying double flange sluice valves confirming for IS 2906/14846 including warn gear arrangement as per test pressure stainless steel spindle caps including all taxes transportation etc complete.Sluice valves PN - 1-- 80 mm dia. 52 Providing and supplying ISI mark CI D/F reflux valves (non-return valves ) of following dia including railway freight, inspection charges, unloading from railway wagon, loading into truck, transportation upto departmental stores, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. complete. Reflux valves as per I.S.5312 Part I (1984)Reflux valves PN - 1-- 80 mm dia. 53 Providing and supplying Air Valves as per IS- 14845 and MJP’s standard specifications double orifice type combined with screw down isolating valve, small orifice elastic ball resting on a gun metal orifice nipple, large orifice vulcanite ball seating on moulded seat ring, inlet face and drilled, including insurance, third party inspection charges, loading, unloading, transportation upto departmental stores, excluding GST levied by GOI & GOM in all respect etc. complete.32 mm Dia.Double ball AV P.N 1 54 Excavation for foundation / pipe trenches in All Types of soil Excavation for foundation / pipe trenches in all types of strata, including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, manual dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. 55 Filling in plinth and floors murum bedding in trenches with approved murum from excavated materials from foundation 15cm to 20cm layers including watering and compaction complete. 56 Lowering, Laying and Jointing H. D. P. E./M.D. P. E. pipes in proper position including all specials by compression fitting/electrofusion and butt fusion jointing procedure as per relevent IS Code complete with all materials for jointing procedure like Electrofusion machine, Electric heater/butt fusion welding machine with hydraulic jack, top loading clamp etc. and all labours as directed by engineer in charge as per IS-7634 Part II For all classes. all labour, material, except cement solvent, rubber ring, as per IS code, etc. complete (with cement solvent joint / ring fit joint). 57 Lowering, laying and jointing in position following C.I.D/F Reflex valves, Butterfly valves and Sluice valves including cost of all labour jointing material, including nut bolts and excluding hydraulic testing etc. complete. (Rate for all class of valves.)Sluice valves PN - 1-- 80 mm dia. 58 Reflux valves PN - 1-- 80 mm dia. 59 Providing and laying in situ, following grades of C.C. of trap/granite/quartzite/gneiss metal for foundtion and bedding incluing dewatering, form work, compaction and curing, finishing, etc. complete. 60 Refilling the trenches with available excavated stuff with soft material first over pipeline and then hard material in 15 cm layers with all leads and lifts including consolidation, surcharging, etc. complete. 61 Providing and fixing in position air valve shaft including providing and fixing GI Medium Class or 6 mm thick M.S. pipe shaft 2.70 M long over branch flange of air valve tee, providing PCC block of M-150 concrete 150 mm thick around the air valve tee including encasing of vertical shaft in PCC M-150 as shown in type design together with providing and making flanged joints wherever required and fixing of air valve over the shaft excluding cost of air valve and branch flanged air valve tee. etc. complete as per type design and as directed by Engineer-in-charge for following diameters of pipe lines (type design attached.) 62 Hydraulic testing of H. D. P. E./ M. D. P. E. pipe line to specified pressure including cost of all materials and labour and water for testing for specified length including cutting, placing end cap making arrangement for filling safe water using reciprocating type pumps which should be able to provide specified test pressure gauges and other necessary equipments, labour,operation charges, etc. required for testing. The rate under this item shall also include cost of retesting, if necessary and reinstating to original position. 63 RCC ESR CAP 33000 LITR STG HT 12.00MItem.No.1 :-Designing(aesthetically),and constructingRCC elevated servicereservoirsof followingcapacitywithRCCstaging consisting of columns, internal and external bracings spaced vertically not more than 4.5 meters centre to centre for E.S.R.having capacity500 m3¬more than 6 m c/cfor E.S.R.havingcapacity above500m3including excavationin alltypesofstrata,foundationconcret,cementplasterwith waterproofing compoundto theinsidefaceofthecontainerincluding refilling disposing of the surplus stuff within a lead of 50 meters, all labour and material chargesincluding lowering, laying, erecting, hoisting and jointing of pipe assembly of inlet, outlet,washout,overflowand bypassarrangementsasper departmental design.providingandfixingaccessoriessuchasStainlesssteel ladder inside and M.S. ladder with G.I. railingoutside, C. I. manholeframeandcoverswaterlevel indicatiors,lightening conductor,G.I.piperailingaroundwalkwayandtopslab, providingspiralstairecase fromgroundleveltorooflevel, M.S.Grill gate of 2 Mtrs height with locking arrangement,B.B. masonry chambers for all valves, ventilating shafts, providing andapplyingthreecoats ofacrylicemulsionwithsilicon additives paint to the structure including roof slab and epoxy paint to internal surface & anti-termite treatment for undergroundpartsofthe structuresandgivingsatisfactory watertightnesstestasperI.S.code,Thejobto include paintingthenameoftheschemeandotherdetailsonthe reservoir as per the directions of Engineer-in-charge.Notes:1. The design of the structure be in accordance with relevent (I.S.3370 - 1965 or revised)2. The design shall satisfy the stipulation as per IS 1893-1984and I.S. 13920/1993 for seismic focrce and I.S.- 11682/1985 for R.C.C. staging of overhead tanks.3.Fordesignhavingmorethan6columns,Providingof internal bracing isobligatory,. External bracking is also 64 Add for Raft Foundation. (7.5%) 65 Providing and supplying ISI standard welded CI double flanged pipe excluding GST levied by GOI & GOM in allrespect but including railway freight, insurance, unloading from railway wagon, loading into truck transport to store, unloading, stacking etc. complete as directed by Engineer -in- charge. (for 2.75 m bare pipe)100MM Pipe 66 80MM Pipe 67 Providing and supplying double flange sluice valves confirming for IS 2906/14846 including warn gear arrangement as per test pressure stainless steel spindle caps including all taxes transportation etc complete.100 mm dia. D/F Sl. ValvePN 1.0 68 80 mm dia. D/F Sl. ValvePN 1.0 69 Providing and supplying ISI standard C. I. specials & fittingwith sealing rubber gasket of S.B.R,complete withcast iron follower gland and M. S. nut bolts coated orotherwise protected from rusting and suitable for D.I.pipesincluding cost of labour, materials, and transportation to stores, loading and unloading excluding GST levied by GOI & GOM in all respect etc. complete as per IS-9523. 70 ADD.DISTRIBUTIONItem No. 1:- Providing and supplying in standard lengths ISI mark rigid unplasticised PVC pipes suitable for potable water with solvent cement joints including cost of couplers, as per IS specification no. 4985 / 1988 including all local and central taxes, transportation, freight charges, inspection charges, loading, unloading, conveyance to the departmental stores / site and stacking the same in closed shed duly protected from sun rays and rains including cost of jointing material i.e. solvemt cement, etc. complete (selffit type to be jointed with cement solvent).110 mm pvc 4 kg pipe 71 90 mm pvc 4 kg pipe 72 75 mm pvc 4 kg pipe 73 Item No.2 Providing and supplying double flange sluice valves confirming for IS 2906/14846 including warn gear arrangement as per test pressure stainless steel spindle caps including all taxes transportation etc complete.Sluice valves PN - 1 --80 mm dia. 74 item no3 Providing at site of works PVC.specials suitable for above pipes including cost of all taxes, freight charges, octroi, loading, unloading and conveyance to Deptt.store etc. complete.10% of Cost of pipes 75 ITEM NO. 4 -6 Excavation for foundation / pipe trenches in All Types of soil Excavation for foundation / pipe trenches in all types of strata, including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, manual dewatering, preparing the bed for foundation and excluding backfilling, etc. complete.. 76 ITEM NO 7 Filling in plinth and floors murum bedding in trenches with approved murum from excavated materials from foundation 15cm to 20cm layers including watering and compaction complete. 77 ITEM N 8 Lowering, laying and jointing with P.V.C. pipes and specials of following class and diameter including cost of conveyance from stores to site of works including cost of all labour, material, except cement solvent, rubber ring, as per IS code, etc. complete (with cement solvent joint / ring fit joint).110 mm pvc 4 kg pipe 78 90 mm pvc 4 kg pipe 79 75 mm pvc 4 kg pipe 80 ITEM NO 9 Lowering, laying and jointing in position following C.I.D/F Reflex valves, Butterfly valves and Sluice valves including cost of all labour jointing material, including nut bolts and excluding hydraulic testing etc. complete. (Rate for all class of valves.) 81 ITEM NO 10 Providing and constructing B.B. masonry valve chamber with 15 cm thick 1:3:6 proportion PCC bedding, excluding excavation, B.B. masonry in C.M. 1:5 Proportion precast RCC frame and cover, etc. complete as directed by Engineer-in-charge. 82 Providing and fixing C.I. road box including loading, unloading and carting to site of work including all necessary excavation in all types of strata and fixing in murum packing, etc. complete. 83 Providing and laying in situ Cement concrete of trap/granite/quartzite/ gneiss metal for PCC work below foundation and footing including normal dewatering,plywood form work, compaction, finishing and curing, etc, complete. M 15 84 Refilling the trenches with available excavated stuff with soft material first over pipeline and then hard material in 15 cm layers with all leads and lifts including consolidation, surcharging, etc. complete. 85 Trial Run For 1 months 86 Cost of electricity (as per M&R statement) 87 Cost of TCL (as per M&R statement) 88 Providing and fixing board displaying information, such as Nameofwork, Tendercost, Name of Contractor, Work completion and liability period etc ,having rectangular shape of 1.20m x 0.90m size made out 18gauge (1.25mm) thick mild steel sheet painted with one coat of Zinc chromate stoving primer and two coats of enamel paint on front side and grey stove enamel on backside and border /messages /symbol setc. with approved colour shade paint complete, on M.S. angle of size 35 x 35x 3mm frame with properly cross braced M.S. angle sof size 35mm x35mm x3mm duly painted including Two M.S. angle iron posts of size 65mm x65mm x6mm, 3.65m long painted with alternate black and white band sof 25cm width including all fixtures etc. and fixing the board sin 1:4:8 concrete block of size 60cmx 60cmx 75cm including, excavation, refilling,transportation, and labour etc complete. Spec. No. As directed by Engineer in Charge