}

Tender For Mrl07-Ithai Khunou To Shamushang Litan Makhongblock: Moirang District: Bishnupur, Imphal West-Manipur

Rural Engineering Department has published Tender For Mrl07-Ithai Khunou To Shamushang Litan Makhongblock: Moirang District: Bishnupur. Submission Date for this Tender is 24-09-2025. Drainage Tenders in Imphal West Manipur. Bidders can get complete Tender details and download the document.




Tender Notice

51074662
Tender For Mrl07-Ithai Khunou To Shamushang Litan Makhongblock: Moirang District: Bishnupur
Tender
Indian
Manipur
Imphal West
24-09-2025
BootCamp

Tender Details

Tender For Mrl07-Ithai Khunou To Shamushang Litan Makhongblock: Moirang District: Bishnupur; 1 PAVEMENT WORKS 2 Clearing and Grubbing Road Land.Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlierand disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Clause 201.(I) By Manual Means(A) In area of non-thorny jungle 3 ConstructionofEmbankmentwithMaterial Obtained from Borrow PitsConstruction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5 4 Scarifying Existing Bituminous Surface to a Depth of 150 mm by Mechanical MeansScarifying the existing bituminous road surface to a depth of 150 mm and disposal of scarified material with a lift upto 3 m and lead upto 1000 m as per Technical Specification Clause 301.4. 5 Construction of Subgrade and Earthen ShouldersConstruction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 303.1. 6 Granular Sub-base with Well Graded Material (Table 400.1)(A) By Mix in Place Method Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavatorat OMC, and compacting with smoothwheelroller to achieve thedesired density, complete as per Technical Specification Clause 401. (ii) For Grading II Material 7 Construction of Panel concrete, plain cement concrete pavement, thickness as per design, over a prepared sub base, with 43 grade cement or any other type as per Clause 1501.2.2 M30 (Grade) coarse and fine aggregates conforming to IS:383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 micron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with shovels, rakes, compacted using needle, screed and plate vibrators and finished in continuous operation including provision of contraction and expansion, construction joints, applying debonding strips, primer, sealant, dowel bars, near approaches to bridge/culvert and construction joints, admixture as approved, curing of concrete slabs for 14 days. Curing compound (where specified) and water finishing to lines and grade as per drawing and technical specification Clause 1501. PCC Grade M-30 Each Panel (0.50 x 0.50) thickness 100 mm. 8 Wet Mix MacadamProviding,laying,spreadingandcompactinggraded stoneaggregatetowetmixmacadamspecification including premixing the material with water at OMC in mechanical mixer (Pug Mill), carriage of mixed materialbytippertosite,layinginuniformlayersin sub-base/basecourseonawellpreparedsub-base andcompactingwithsmoothwheelrollerof80to 100kN weight to achieve the desired density including lighting, barricading and maintenance of diversion,etcasperTables400.11&400.12and Technical Specification Clause 406.By Mechanical Means 9 Prime Coat :Low porosityProviding and applying primer coat with bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70-1.0 kg/sqm using mechanical means as per Technical Specification Clause 502 10 Tack Coat :Providing and applying tack coat with Bitumen emulsion (RS-1)using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared dry and hungry bituminous surface cleaned with Hydraulic broom as per Technical Specification Clause 503. 11 Mix Seal Surfacing (With @8% Waste plastic of bitumen content)Providing, laying and rolling of close-graded premix surfacing material of 20 mm thickness composed of 11.2 mm to 0.9 mm (Type-A) or 13.2 mm to 0.9 mm (Type-B) aggregates using penetration grade bitumen to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 8-10 kN static roller and finishing to required level and grades as per Technical Specification Clause 509.By Mechanical Means Type B Bitumen (S-65) 12 Dismantle of Existing Slab Culvert(3nos.) 13 Dismantling of StructuresDismantlingofexistingstructureslikeculverts,bridges,retainingwallsand otherstructurecomprisingofmasonry,cementconcrete,woodwork,steel work, including T&P and scaffolding wherever necessary, sorting the dismantledmaterial,disposalofunserviceablematerialandstackingthe serviceable material with all lifts and lead of 1000 m as per Technical Specification Clause 202.II By Mechanical Means(A) Cement Concrete 14 PCC below Abutment 15 PCC below Return wall 16 c) CC In Flooring 17 (B) Reinforced cement concreteAbutment cap 18 Dirt wall 19 Deck slab 20 Column 21 (A) Cement ConcreteAbutment 22 Return wall 23 Road Safety and Road Furniture 24 Providing and Fixing Logo of PMGSY Project ProvidingandfixingoftypicalPMGSYinformatory signboardwithLogoasperMORDspecifications and drawing. Three MS Plates of 1.6 mm thick, top andmiddleplatedulyweldedwithMSflatiron 25mm x 5m size on back on edges. The lower plate will be welded with MS angle iron frame of 25mm x 25mmx5mm.Theangleironframeofthelower most plate and flat iron frame of middle plate will be welded to 2 nos. 75mm x 75 mm of 12 SWG sheet tubes posts duly embedded in cement concrete M- 15gradeblocksof450mmx450mmx600mm, 600mm below ground level. The top most diamond plate will be welded to middle plate by 47mm x 47mm of 12 SWG steel plate tube. All M.S. will be stove enameled on both sides.Letteringandprintingarrows,borderetc.willbe painted with ready mixed synthetic enamelpaint of superior qualityinrequiredshadeand colour. All sections of framed posts and steeltubewillbepaintedwithprimerandtwocoatsofepoxy paint as per drawing Clause 1701 and Annexure 1700.1 25 Providing and Fixing Citizen information Board of PMGSY Project(Steel Tube) Providing and fixing of Citizens Information Board for PMGSY Project with Logo as per MORD specifications and drawing. Two MS Plates of 1.6 mm thick, top and bottom plate duly welded with MS flat iron 25mm x 5m size on back on edges.The plates will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frames of the plates will be welded to 2 nos. 75mm x 75 mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 600mm x 600mm x 750mm, 750mm below ground level.All M.S. will be stove enameled on both sides.Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour.All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1 26 Providing and Fixing Maintenance Information Board of PMGSY Project Providing and fixing of Maintenance Information Board for PMGSY Project with Logo as per MORD specifications and drawing. One MS Plates of 1.6 mm thick, top and bottom plate duly welded with MS flat iron 25mm x 5m size on back on edges.The plates will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frames of the plates will be welded to 2 nos. 75mm x 75 mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 600mm x 600mm x 750mm, 750mm below ground level.All M.S. will be stove enameled on both sides.Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour.All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1 27 ReinforcedcementconcreteM15 gradekilometrestone/localstoneofstandarddesignasperIRC:8 fixing in position including painting and printing, etc. as per drawing and TechnicalSpecification Clause1703 28 (i) 5th Kilometre Stone (precast) 29 (ii) Ordinary Kilometer stone (precast) 30 (iii) 200m Stone (precast) 31 Construction of Job pillars as per Fig. 1600.1 (d)and Technical Specification Clause 1602.4 32 Painting lines, Dashes, Arrows, etc. on Road in Two Coats on New WorkPainting lines, dashes, arrows, etc. on roads in two coatson new work with ready mixed road marking paint conforming to IS:164 on bituminous/concrete surface, including cleaning the surface of all dirt, dust and other foreign matter, demarcation at site and traffic control as per drawing and Technical Specification Clause 1702 33 Traffic SignsProviding and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflectivesheeting vide Clause 1701.2.3 fixed over aluminium sheeting,1.5mmthicksupportedonamildsteel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundationwithM15gradecementconcrete450 mm x 450 mm x 600 mm, 600 mm belowground level as per drawings and Technical 34 (ii) 600mm equilateral triangle 35 (iii) 600mm circular 36 Surface Drains in Ordinary RockConstruction ofunlined surface drain of average cross-sectional area 0.4 sqm in ordinary rock to specified lines, grades, levels and dimensions as per approved design and Technical Specification Clause 307.Excavated material to be used in embankment at site. (B) Mechanical Means 37 Construction of Pucca Drain(500m) 38 Excavation for StructuresEarthwork in excavation for structures as per drawing and technical specificationsClause305.1including setting out, construction of shoring and bracing,removal ofstumpsandother deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitablematerial.I) Ordinary soil (i) upto 3 m depth 39 Providing concrete for plain/reinforced concrete in open foundations complete asperdrawingsand technicalspecifications Clause 802, 803, 1202 & 1203I. P.C.C grade M10 (i) Nominal mix 1:3:6 40 Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204. I) P.C.C grade M 15 ii) Nominal mix (1:2.5:5) 41 Construction of Retaining Wall(80m) 42 Excavation for StructuresEarthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitablematerial. I. Ordinary soil (i)Upto 3 m depth 43 Providing concrete for plain/reinforced concrete in open foundations complete asperdrawingsand technicalspecifications Clause 802, 803, 1202 & 1203I. P.C.C grade M10 (i) Nominal mix 1:3:6 44 Plain/reinforced cement concrete in substructure complete as perdrawingsandtechnicalspecificationClauses802,804, 805, 806, 807, 1202 ans 1204 II. P.C.C. grade M 20(i) Nominal mix (1:2:4) 45 Backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification Clause 1204.3.8(I) Granular material 46 Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100mm dia AC pipe extending through the full width of the structureswithslopeof1(V):20(H)towardsdrawingface complete as per drawing and technical specification Clauses 614, 709, 1204.3.7 47 Construction of 1.5m span slab culvert(ht.-3.61m)(2nos.) 48 Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitablematerial. I) Ordinary soil i) Upto 3 m depth 49 Fillling in foundation trenches as per drawing and technical specification Clauses 305.3.9 II. Earth filling (For marshy soil) 50 Providing concrete for plain/reinforced concrete in open foundations complete asperdrawingsand technicalspecifications Clause 802, 803, 1202 & 1203I. P.C.C grade M10 (i) Nominal mix 1:3:6 51 Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204. I) P.C.C grade M 15 ii) Nominal mix (1:2.5:5) 52 Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 III) R.C.C grade M 20 53 Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5 II) R.C.C M 25 54 Supplying, fitting, and placing HYSD bar reinforcement in superstructure complete as per drawing and technical specifications Clauses 1002, 1010 and 1202 55 Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7 56 Providing and laying filter media with granular crushed aggregates as per specification to a thickness of not less than 600 mm with smallersize towards the soil and bigger size towards the wall and providing over the entire surface behind abutment, wing wall, return wall to the full height, compacted to firm condition complete as per drawing and technical specificationClause 1204.3.8 57 Construction of 4m span slab culvert(Ht.- 5.01m)(1no.) 58 Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitablematerial. I) Ordinary soil i) Upto 3 m depth 59 Fillling in foundation trenches as per drawing and technical specification Clauses 305.3.9 II. Earth filling (For marshy soil) 60 Providing concrete for plain/reinforced concrete in open foundations complete asperdrawingsand technicalspecifications Clause 802, 803, 1202 & 1203I. P.C.C grade M10 (i) Nominal mix 1:3:6 61 Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204. I) P.C.C grade M 15 ii) Nominal mix (1:2.5:5) 62 Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 III) R.C.C grade M 20 63 Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5 II) R.C.C M 25 64 Supplying, fitting, and placing HYSD bar reinforcement in superstructure complete as per drawing and technical specifications Clauses 1002, 1010 and 1202 65 Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7 66 Providing and laying filter media with granular crushed aggregates as per specification to a thickness of not less than 600 mm with smallersize towards the soil and bigger size towards the wall and providing over the entire surface behind abutment, wing wall, return wall to the full height, compacted to firm condition complete as per drawing and technical specificationClause 1204.3.8 67 Construction of Hume pipe culvert(ht.-2.465m)(5nos.) 68 Earthworkinexcavationforstructuresasperdrawingandtechnical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitablematerial. I. Ordinary soil (i) upto 3 m depth 69 Providing concrete for plain/reinforced concrete in open foundations complete asperdrawingsand technicalspecifications Clause 802, 803, 1202 & 1203I. P.C.C grade M10 (i) Nominal mix 1:3:6 70 Stone Masonry Work in cement mortar in foundation of Head walls complete as per drawing and technical specification Clasue 1109 A) In 1:4 cement mortar 71 Bedding for Pipe (i) Type A (Concrete Cradle) BeddingLaying concrete cradle bedding with M15 Grade Cement Concrete as per Clause 1105 (i) 72 Providing and Laying Reinforced Cement Concrete Pipe NP3 as per design in Single Row Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granularmaterial in single row includingfixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106. (A) 1000 mm dia. 73 Plastering with Cement Mortar (1:4), 15 mm thick on brick/stone work in substructure as per technical specification 74 Routine Maintenance Component for 5(Five) years after construction(Not to be quoted yearwise) 75 1st year in INR - Rs 473000 76 2nd year in INR - Rs 709000 77 3rd year in INR - Rs 1181000 78 4th year in INR - Rs 1181000 79 5th year in INR - Rs 1181000

Key Value

Document Fees
INR 20000 /-
EMD
INR 883000.0 /-
Tender Value
INR 4.41 Crore /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail