Providing And Fixing High Mast Lights Installation Work Providing And Fixing High Mast Lights Installation Work , Providing & Laying P.V.C. / Xlpe Insulated & P.V.C. Sheathed Arrmoured Aluminium Cable Confirming To Is:1554 P-I / Is :7098 P - I Of 1.1 Kv With H4- Grade Electrolytic Aluminium Conductor Confirming To Is 8130 Of Purity >99.6 %, Round / Flat Strip Armouring Of Cables, Inner / Outer Sheath Confirming To Is:5831 In Existing Rcc / Hume / Stoneware / Pvc Pipe/ Open Duct/Cable Trench / Cable Tray(With Cable Tie) Including Testing Etc. As Required Of Following Size. Oem Must Have Its Own In House Nabl Accrediated Laboratory For Testing Procedure As Per Is:10810.For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 16.0 Sq. Mm 4 Core , 25.0 Sq. Mm 3.5 Core , Supply Installation Testing & Commissioning Of High Mast Lighting System (As Per Plg 07 Of Ilp Uk Techinical Report No 7 Of Ile Uk /Is:875 Part-1 – 2015//Bsen10025/And Is:2062 )Consisting Of Totally Hot Dip Galvanised By Piecewise Single Dipped Method High Mast, Lantern Carriage Suitable For Up To 12 Nos Luminaries With Welded Arm (Excluding Luminares), Mast Head Frame Assembly With Full Cover, Including 1 No. Led 15 Watts Aviation Obstruction Lights, Double Drum Type Self Sustaining Winch, Integral Power Tool Accesible From Door With Padlocking Arrangement (Winch Motor With Control Circuit) Hot Dipped Galvanised Heavy Duty Pipe Lightening Finial, Stainless Steel 6 Mm Dia. Wire Ropes (Aisi 316, 7 / 19 Costruction 3 No. Rope For Lantern Carrage & 2 No. Rope For Winch Assembly ) Foundation Bolt, Torque Limiter,Epr Insulated Pcp Sheathed 5 Core X 2.5 Sq.Mm Trailing Cable, Including Outdoor Type Control Panel For Auto On / Off, Reverse / Forward Motor Operation. The Mast Is Constructed From Mild Steel Plates (As Per Is 5986 Gr. 510 ) Cut And Folded To Form A Polygonal Section, Telescopic Jointed And Welding As Per Bs 5135.Etc. As Required On Existing Foundation. ( See Table P - 03 For Specs.) Oem Must Have Type Test Certificate For Wind Tunnel Test . All As Per Pre Approved By Engineer In-Charge. All As Per Pre Approved By Engineer In-Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached With This Bsr . 12.5 Mtr Hm (In 2 Section) Suitable For 6 No. Luminaries 2 No. Rope For Lantern Carrage & 2 No. Rope For Winch Assembly , 16.0 Mtr Hm (In 2 Section) Suitable For 9 No. Luminaries , Providing & Fixing Of Ik08 Ip-66 Protected High Power Led Flood Light System With Single Piece Pressure Diecast Aluminium Housing, Toughened Glass Diffuser With Suitable Lenses On Led To Achieve Various Beam Angles, Of High Power Led Of 3 To 5 Watt Each . Integrated Potted Driver As A Unique Bis R Number Having Efficiency More Than 85 % And In Compliance To Bis Certified And Trade Mark Certificate. The System Level Luminaire Efficacy >=125 Lm/ Wt. Led Driver Input Voltage Ac 120 To 270 V Ac With High Voltage Cutoff @>=300 V Ac And Auto Resetting Safety .Power Factor >0.95 , Thd(I) <10% , Driver Current <=750Ma. Driver Should Be Phase To Phase Protection Of 440 V For 4 Hrs. Electrical Connector , Surge Protection Min >=4Kv Internal And 10Kv External But Inside Driver Compartment, System Life Of 50000 Burning Hours With 70% Of Initial Lumens Maintained, Cri>70 And Cct 5700K ±355K. Manufactures Word Mark/Name Engraved/Embossing/Screen Printing On Die Cast Housing To Allow Traceability/Authenticity. Fixture Shall Be Is 10322 Complianced.Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Led Fixtures. (Lm79/Lm80) Certificate/ Report With Liable Warranty Of Product/Accessories From Oem Shall Be Submitted. All As Per Pre Approved By Engineer In-Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached With This Bsr High Power Led Flood Light Minimum Lumen Output 22400 Lm , Earth Work In Excavation For Roadway, Including Trimming Bottom And Side Slopes In Accordance With Requirement Of Line, Grades And Cross Sections, Including Disposal Of Surplus Material With All Lift And Lead Upto 1000 Metre As Per Mort&H Specification Clause 301. In Ordinary Rock , Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centring And Shuttering - All Work Upto Plinth Level : 1:1½:3 (1 Cement : 1½ Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size). , P / L Of Double Wall Corrugated Hdpe Pipe Confirming To Is : 16205 P-24, Stiffness Class 750 N, Externally Corrugated And Having Smooth Surface Inside With Hdpe Coupler, Elbow, Tee At Required Depth Below The Ground For Laying Cable Of Following Nominal Outer Dia. Mfr Test Report From Nabl Accrediated Is To Be Submitted.(Excavation Of Earth & Back Filling With Compaction Is To Be Paid Extra)All As Per Pre Approved By Engineer In-Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached With This Bsr .50 Mm , Supply & Laying Following Size B Class , G.I. Pipe Confirming To Is : 1239 P - 1 ( 2004 ) With Accessories Like Bend, Socket Etc. For Laying Earth Conductor/ Strip / Cable In Ground/ Surface/ Recess As Required. All As Per Pre Approved By Engineer In-Charge. (Earth Excavation Will Be Paid Extra)All As Per Pre Approved By Engineer In-Charge. For Additional Technical Parameters Of Products/ Work , Refer Annex Ure A Attached With This Bsr . 50 Mm Dia. , Pipe Earthing As Per Is:3043- 1987 With 3.0 Mtr. Long, 40 Mm Dia. B Class G.I. Pipe Is: 1239 (Part-1) 2004, Equivalent To Bs : 1387 With Perforated Holes Of 12 Mm Dia ,Including All Accessories Like Nut, Bolts, Reducer, Nipple, Wire Meshed Funnel, And Heavy Duty Weather Proof Poly-Propylene Earth Pit Chamber With Lockable Jam Free Lid Suitable For Safe Working Load 5000 Kg Or More Of Size Top Dia. 225 To 260 Mm, Bottom Dia 300 To 350 Mm. And Height 250 To 300 Mm. And Embodying The Pipe Complete With Alternate Layers Salt And Coke/ Charcoal, Testing Of Earth Resistance For Value Of 5 Ohms Or Less As Required & Must Record By Engineer In-Charge During Site Visit And Ensure To Enter In Measurment Book.All As Per Pre Approved By Engineer In-Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached With This Bsr . , Providing & Fixing Of 240/415 V Ac Mcb With Positive Isolation Of 10 Ka Breaking Capacity (B/ C/D Tripping Characteristic As Per Type Of Load And Site Requirement) 4 Kv Impulse Withstand Voltage, Isi Marked Is 8828(1996) / Conforming To Iec 60898-1 2002, Iec 60947-2, Low Watt Losses, Trip Free Mechanisum , Energy Limiting Of Class 3 As Per Iec, Minimum Phase Termination Capacity Of 35Sq.Mm. , Conductor Line Load Reversibility , Ip 20 Contact Protection And Fitted In Existing Distribution Board/Sheets, Minimum Electrical Operation 20,000 Upto 20 A Rating And 10,000 Upto 63 A, 5000 For 80 A & Above Rating Including Making Connections, Testing Etc. As Required. Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Type Test Reports & All As Per Pre Approved By Engineer Incharge. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr Single Pole Mcb (With B/C Curve Tripping Characteristics) 6 A To 32 A Rating , Providing & Fixing Of 240/415 V Isolator Isi Marked Is:13947- Iii/Conforming To Iec 60947-3, Suitable For Ac22a Utilization Category, 4Kv Impulse Withstand Voltage, True Contact Indication, Red Colour Dolly / Lever Shall Have Single Mould Covering Overall Poles For Operation , Two Position Din Rail Mounting, Minimum Phase Termination Capacity Of 35Sq.Mm. Ip 20 Contact Protection And Fitted In Existing Distribution Board / Sheet Including Making Connections, Testing Etc. As Required. Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Type Test Reports & All As Per Pre Approved By Engineer In-Charge.For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr Four Pole Isolator 63 A Rating , Providing & Fixing Of Mechanical / Digital Time Switch Having Following Day / Week Programme And Minimum 100 Hours Reserve And Ac1 Rating Of 16-20 Amperes Including Making Connection, Programming Conforming To Iec 60730-1 And 60730-2-7 Etc. As Required. All As Per Pre Approved By Engineer In-Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached With This Bsr . One Day Reserve (Analog Type ) , Providing & Fixing Of Ac Operated Heavy Duty 230 /440 Volt Power Contactor As Per Pwd Specification For Electrical Works, Isi Marked Is/Iec 60947-4-1 : 2000 Having Provision Of Mechanical Interlocking, Auxilary Contacts, Din Rail Mounting Type Including Making Connections, Testing Etc. As Required. All As Per Pre Approved By Engineer In-Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached With This Bsr . 4 Pole Power Contactors With Following Ac 1 Rating 63 Amp , Structural Steel Work In Single Section Fixed With Or Without Connecting Plate Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete. , Supplying And Drawing Fr Pvc Insulated & Unsheathed Flexible Copper Conductor As Per Pwd Specification For Electrical Works With Isi Marked (Is:694) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From 99.90 % Purity Copper, Class 5 Stranding In Acc. To Is:8130/Iec 60228 For Lower Watt Loss , Oxygen Free For Less Chances Of Oxidization, Insulation Pvc Type A/C/D , Flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Is:3961 Part 5, In Existing Surface Or Recessed Pvc/ Ms Conduit/Casing Capping Making Connections With Copper Lugs Of Suitable Size, Ferrules,Testing Etc. As Required. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Wires. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 4 X 6.0 Sq.Mm , Supply & Laying Following Size Earth Strip In Horizontal Or Vertical Run In Surface By Means Of Earth Strip Dmc Insulator Including Riveting/ Soldering/ Welding, Jointing Shall Be Done By Overlapping And With 2 Set Of Brass (For Cu Strip) / Gi (For Gi Strip) Nut Bolt & Spring Washer Spaced At 50Cm Making Connection Etc. As Required.All As Per Pre Approved By Engineer In-Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached With This Bsr. 25Mm X 3Mm G.I. ( Hot Dipped ) Strip , Supply & Laying Following Size Earth Wire In Horizontal Or Vertical Run In Ground/Surface/Recess Including Riveting, Soldering, Saddles, Making Connection With Gi/Cu Purity Purity >95% Thimble Etc. As Required. All As Per Pre Approved By Engineer In-Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached With This Bsr . 8 Swg G.I. ( Hot Dipped ) Wire , P & F In Position Frame Made Out Of M.S. Angle (Riveted Or Welded) Finished With Two Coats Of Red Oxide And Two Coats Enamel Paint Including Cutting, Welding, Holes Etc.Of Following Sizes As Required.For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 25Mm X 25Mm X 5Mm , P & Fixing Powder Coated Crca Sheet Enclosures On Existing Angle Iron Frame By Means Of Nuts And Bolts And Making Holes , Din Rail Etc. As Required.For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 1.6 Mm Thick , P & Fixing M.S. Flat On Existing Angle Iron Frame And Making Required Nos. Of Holes For Fixing Accessories Including One Coat Of Red Oxide Paint And Two Coats Of Enamel Paint Etc. As Required.For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 32 Mm X 5 Mm