| 1 | Conducting Geophysical Survey Charges including all other charges. |
| 2 | Drilling of 150mm vertical bores in Hard rock areasto the required depth as directed by the TOWN PANCHAYAT Officers including labour charges for inserting casing pipes, assembling in the drilled holes, including welding the joint if necessary grouting the casing pipes etc., and including transportation charges for the rig and supporting vehicles from one place to another. a)FROM 0 M TO 150 M |
| 3 | b)FROM 151M TO 180 M |
| 4 | c)FROM 181M TO 210 M |
| 5 | d)FROM 211M TO 240 M |
| 6 | e)FROM 241M TO 270 M |
| 7 | f)FROM 271M TO 300 M |
| 8 | Supply and Delivery Of unplasticised plain PVC 150mm dia casing pipes of the following diameter in 3 metres length with screwed and socket ends and centering guides for every 15 metre length of pipes as per IS 12818/2010 and as amended from time to time to suit deepbore well upto 80m depth (CS) for delivery at site of work with IS marking including loading, unloading freight, transit insurance etc., complete. |
| 9 | Supply and delivery of(75LPMX250 HEAD) THREE PHASE SUBMERSIBLE PUMPSET SUITABLE FOR 15OMM DIA BOREWELL AS PER IS 8034/2002 WithOUT PANEL BOARDSupply and delivery of clear water vertical wet type submersible pumpset suitable for 150mm dia borewell conforming to IS 8034/2002 with latest amendments and BEE 3 Star Rated capable of discharging noted LPM against head of water column due to all causes. The pump shall be with stainlesss steel shaft and dynamically balanced bronze or Cast SS impeller, brass screws and CI FG 200 grade pump bowl/difuser With ISI mark. The pump shall be directly coupled to a continuos rated two pole suitable wet type vertical squirrel cage induction motor asper IS9283 suitable for operation in AC 3 phase 415v+/- 10%,50 HZ +/- 5% |
| 10 | THREE PHASE PANEL BOARD STAR WITH TWO LEVEL GUARD AND AUTO START: Supply and delivery of Star-Delta starter confirming to IS 13947 and IEC 947 suitable KW raing For operation in AC3/Phase/5OHZ(+/-5%) and 415V (+/-10%) including 3 pole magnetic Contactor with under voltage release-3 nos. CT operated Ammeter(65 mm dia) with suppressed Scale, Voltmeter (65mm dia), Voltmeter selector Switch, Minature circuitr braeker, Thermal Overload relay, Air Break contactors suitable for next Standard higher KW rating, Single phasing preventor. dry running preventor and on/off Push button switches, wiring with 1 sq.mm/4 sq. mm copper pvc insulated cable, powder coated vermin proof box, Including the capacitor (the cost of capacitor is to be taken separately) |
| 11 | Supply and Delivery of 4 sq.mm PVC Insulated and Sheathed 3 core flat type copper cable confirming to IS 694/1990including loading and unloading charges etc., complete. |
| 12 | Supply and Delivery of 50mm dia UPVC column pipe including all charges |
| 13 | Supply and fixing of 50 mm GM Gate Valve including all charges |
| 14 | 100 Amps Porcelain fuse unit (500 V) including all charges |
| 15 | 5 KVR Capacitor including all charges |
| 16 | 63 Amps TPN metal clad switch with rewirable fuse units.including all charges |
| 17 | Supply and fixing of 2\" NRV .including all charges |
| 18 | Supply and Delivery of MS Kiosk of size 0.75m x 0.45m x 0.75m made up of MS angle of size 50mm x 50mm x 4mm alround covered with 16 gauge Ms Sheet and Kiosk door Made up of MS plates of Size 25mm x 3mm including cutting ,Welding,Grinding,locking arrangement and labour charges etc.., |
| 19 | Labour Charges for erectionSubmersible pumpset in borewell/open well including fixing and jointng submersible cable with proper clamps upto the starter to required depth and also fixing of riser pipes to the required depth Values erection clamps pressure gauges upto the exterior wall of pump room and erection of panel board consisting of TPICN switches starter, voltmeter,Ammeter,three pilot (indicating ) lamps capcitor single phasing preventor, Water level guard and laying and jointing the cables and twin earthing as per IE rules etc., complete and testing the pumpset and trail run for 10 days |
| 20 | Supply and run of 4x6 sq.mm (84/0.30) PVC insulated SC unsheathed CU.Conductor of 1100 V Grade on 7/20 GI bearer wire for Service connection main.(SD 68) |
| 21 | Supply and run of 4x6 sq.mm (84/0.30) PVC insulated SC unsheathed CU.Conductor of 1100 V Grade in 32mm dia GI pipe (Class ;B\") Suitably bent at both ends with Necessary angle iron up right and end supports for main. (SD 73) |
| 22 | Earthwork excavation and depositing on bank with initial lead of 10m and initial lift of 2m Hard stiff clay, stiff black cotton, hard red earth, shales, murram gravel, stoney earth and earth mixed with small size boulders and hard gravelly soil.SS20B. |
| 23 | Supply and delivery of PVC Pipes including cost of all charges etc., completed - 90 mm OD dia 6kg/ cm2 PVC Pipe |
| 24 | Towards laying of PVC Pipes and specialsincluding cost of all charges etc., completed - 90 mm OD dia 6kg/ cm2 PVC Pipe |
| 25 | Refilling the excavated earth including cost of labour charges etc., completed |
| 26 | Earth work excavation for foundation and depositing on bank with in the initial lead of 10m and a lift of 2m in hard stiff clay, stiff block cotton, hard red earth, shales, murram, gravel, stoney earth and earth mixed with small size boulders etc. complete. complying with std. specifications.SS 20 B |
| 27 | Plain Cement Concrete 1:4:8 Mix (one part cement, Four part sand and Eight part of aggrigate) using 40mm size ISS HBG metal machine crushed from approved quarry including cost and conveyance of all materials to site, loading and unloading charges and labour charges for mixing, laying and curing etc. complete. Complying with std. specifications. |
| 28 | Brick Work in Cement Mortor 1:5 Mix (one cement, five sand) using best II Class Bricks of size9 ” x 4 3/8 “x 2 3/4 ”from approved quarry including cost and conveyance of all materials to site. Loading and unloading charges and labour charges for mixing, laying and curing etc. complete. Complying with std. specifications |
| 29 | Supplying fabricating and placing in position of steel rods using TMT. or Ribbed Tor Steel including cost of binding wire, cost of labour charges for fabrication and placing in positionetc. Complete. Complying with std. specifications. |
| 30 | Providing and laying in position Standardised Concrete Mix M-20 Grade in accordance with IS 456 - 2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement contenet of 325Kg/ cum and maximum water cement ratio of 0.55 including admixture (Plasticiser / super plasticiser) in recommended proportions as per IS 9103 to accelerate, related setting of concrete, improve workability without imparing strength and durability with about (5.0cum), 7730Kg of 20mm machine crushed stone jelly and with about (3.3 cum), 5156kg of 10 - 12mm machine crushed stone jelly and with about (4.79cum) 7670 kg of Crushed Stone Sand (M- Sand), but excluding cost of reinforcement grill and fabricating charges centering and shuttering but including laying, vibrating with mechanical vibrators, finishing, curing, etc and providing fixtures like fan clamps in the RCC floor / roof slabs wherever necessary without claiming extra cost etc., complete complying with standard specification and as directed by the departmental officers - |
| 31 | Plastering with cement mortar 1: 5 mix to 12mm thick including cost and conveyance of all materials to site including curing etc.,complete as per standard specification |
| 32 | White washing two coats with freshly burnt shell lime white in colour in all floors including cost of lime and other materials brushes scaffolding charges etc.complete complying with standard specification and as directed. -100sq.m S.I.333 |
| 33 | Supply of 1000Ltr.Capacity PVC water tank including cost and conveyances of complete complying by the departmental Enginners |