Tender For Electrical Work In The Construction Of Trauma Center At Jobner, Distt Jaipur - Wiring oflightpoint/fanpoint/exhaustfanpoint/callbell point with 1.5 sq. mmnominalsizeFRPVCinsulated unsheathedflexible copperconductor1.1kV grade and 1.5 sq.mmnominalsize FRPVCinsulatedunsheathedflexible copper earth conductor 1.1 kV grade (IS:694)inrecessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & itsISI marked (IS:3419-1988) accessories, round tiles, 1.2 mmthick HotDippedGalvanizedModularBoxwithearth terminal,10AModularswitch,Modularfaceplatewithgrid plate,3pinceilingrose/Holder/3wayconnector,screws, making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E-05&E-07Foradditionaltechnicalparametersof product / work refer Annexure A attached with this BSR 2 a) Short point (up to 3 mtr.) 3 b) Medium point (up to 6 mtr.) 4 c) Long point(up to 10 mtr.) 5 Wiring oftwincontrol lightpointwith1.5 sq.mm nominal size FR PVC insulated unsheathed flexible copper conductor1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathedflexiblecopperearthconductor1.1kVgrade (IS:694) inrecessedISImarked MMS(IS:9537P-III) PVCconduit&itsISImarked(IS:3419-1988)accessories, round tiles, 2 Nos Hot Dipped Galvanized M.S Modularbox of1.2mmthick withearthterminal,2Nos10Atwoway Modular switch, 3 pin ceiling rose / holder / 3 way connector,Modular face plate with grid plate,screws,making connections,testingetc.asrequired. Forspecificationof copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work referAnnexure A attached with this BSR 6 Medium point (up to 6 mtr.) 7 Long point(up to 10 mtr.) 8 Wiring of3/5 pin 6amp. Lightplug pointwith 1.5sq. mm nominalsize FRPVCinsulatedunsheathedflexiblecopper conductor1.1kVgrade and1.5sq.mmnominalsizeFR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) inrecessed ISI marked MMS ( IS:9537 P III)PVCconduit&itsISImarked(IS:3419- 1988)accessories,HotDippedGalvanized Modularboxof1.2 mm thick with earth terminal, 10 A modularswitch, 3/5 pin 6 A modularsocket, Modularface plate with grid plate, screws,makingconnections,testingetc.asrequired. For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E-05&E-07Foradditionaltechnicalparametersofproduct / work refer Annexure A attached with this BSR 9 a) On board 10 SupplyingandfixingofpowerplugpointwithModular accessoriesasperPWDspecificationforelectricalWorks, on hot dipped galvanized modular box of 1.2 mm thick with earthingterminal/connectoronsurfaceorinrecessedwith suitable size of modular face place with grid plate and cover plate including cost of ISI marked modular 16 amp. Switch (IS:3854)and6/16amp.socketoutlet(IS:1293)making connection,testing,etc.asrequired.Forspecificationof Wiring accessories refer ChapterE - 07related item & For additional technical parameters of product / work referAnnexure A attached with this BSR 11 SupplyinganddrawingFRPVCinsulated&unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130: 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D, flame retardantas per IS 10810-53, better amperage rating as per IS:3961 part 5, inexisting surfaceorrecessedPVC/MSconduit/casing cappingmakingconnectionswithCopperLugsofsuitable size, Ferrules,testing etc. as required. OEM Must have its own inhouseNABLlabsetupforalltesting facilitiesforwires. Foradditionaltechnicalparametersofproduct/workreferAnnexure A attached with this BSR 12 a) 1 x 1.5 sq.mm 13 b) 2 x 2.5 sq. mm. + 1x1.5sqmm 14 c) 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 15 e) 4 x 10.0 sq.mm 16 g) 4 x 6.0 sq.mm 17 h) 1 x 4.0 sq.mm 18 i) 1 x 6.0 sq.mm 19 Providing & Fixing of Recessed/surface mounting heavy duty horizontaltypeDoubleDoor(Metal/Glazed)Distribution board with Metal end box made outfrom Galvanized steel / CRCAsheetnotlessthen1.2mmthick conformingtoIS- 8623-1&3/ IEC61439-1&3, powderpainted complete withreversibledoor(fordoubledoorDBonly)100amp. insulatedcopperbusbar/shortinglink,copperneutrallink, copperearthlink,colorcodedinterconnectingwireset of suitableratinganddinbar,maskingsheet, makinginternal DBterminations with copper lugs, Ferrules,detachable glandplate,includingmakingconnections,testingetc.as required.OEMshallhavesubmit NABL/CPRI/ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 20 6.10.6) Metal door (Three phase) Per phase isolation,Vertical IK-09 and IP-43 with Metal end box 21 6.10.6.2) 6Way(Incomer 8,Sub Incomer2+2+2) 22 Providing&Fixingof240/415VACMCBwithpositive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conformingtoIEC60898-12002,IEC60947-2,lowwatt losses,tripfree mechanisum,energy limitingof class3as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fittedin existingdistributionboard/sheets,minimum electrical operation 20,000 upto 20 A rating and 10,000 upto63A,5000for80A&aboverating includingmaking connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type testreports& All as per pre approved by Engineer in charge. For additional technicalparametersofproduct/workreferAnnexureAattached with this BSR 23 a)SinglepoleMCB(WithB/CcurvetrippingCharacteristics) 24 6 A to 32 A rating 25 b)FourpoleMCB(WithB/CcurvetrippingCharacteristics) 26 50/63 A rating 27 S&Ffollowingsizes(dia.)ofISImarkedvirginmaterial MMS ( IS:9537 P - III ) PVC conduit along withISI marked (IS:3419-1988)accessoriesasrequired in recess including cutting the wall, covering conduit and making good the same as required. Foradditional technical parameters ofproduct/work refer Annexure A attached with this BSR 28 a) 20 mm 29 b) 25 mm 30 c) 32 mm 31 P&Fphenoliclaminatedsheet2.0mmthickoffollowing size . Including screws, cup washer as required.For additional technicalparametersofproduct/workreferAnnexureAattached with this BSR 32 75 mm dia 33 Providing & Fixing of modular type 120 W Step Fan regulatordulyISImarked(IS11037:1984)withCM/L no. printed madeoutofunbreakableandfireretardantvergin polycarbonatewithbrassterminalsandcaptivescrews& silveralloy contacttip withIP-20rating , including allas per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters ofproduct / work refer Annexure A attached with this BSR 34 5 step fan regulator 2 Module 360 dgree rotating 35 Making of hole in wall (brick/stone) of required and placing NP-2 RCC pipe ring of required size for housing exhaust fan andmakinggoodthesame,withcementplasterrequiredof following size. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, referAnnexure A attached with this BSR . 36 Up to 457 mm size 37 P & F 1.2mm thickM.S. Recessed fan box, hexagonal/ round ofsize 130 mm dia, depth 75mm, 12 mm dia rod fan hook with 100 mmlength extendedon eachside .All asperpre approvedbyEngineerincharge. Foradditionaltechnical parameters of product / work refer Annexure A attached withthis BSR 38 Providing&FixingofHeavydutycapacitorstart,copper wound Doubleballbearing 900/1400RPMsinglephase Exhaust fanconformingtoIS:2312ISImarkedinexisting openingincludingmakingconnectionstestingetc.as required. All as per pre approved by Engineer in charge.For additionaltechnicalparametersofproducts/work ,referAnnexure A attached with this BSR . 39 300 mm sweep(900/1400 RPM) 40 P & F of Gravity Louver shutter of superior quality made out of frame of18 swg M.S. sheet & Louvers made from 24 swg MS Sheetwith enamel paint including cost of nuts, bolts, etc as reqd.All as per pre approved by Engineer in charge.For additionaltechnicalparametersofproducts/work ,referAnnexure A attached with this BSR . 41 Up to 380 mm size 42 Providing&Fixingofenergyefficientdirectfit(Retrofit) Polycarbonate/Glass housing SMDMidPowerLEDtube rod (withintegraldriver&alumn.heatsink),onexisting fixture.system lumen efficacy ≥ 100 lm/Watt output, internal surge protection of 2.5 KV ,THD < 20% ,p.f.≥0.95,CRI >80 , life time ofminimum 35000Burning Hourswith,70%of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/5700°K/6000°K/6500°K(AsperANSIBin),maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate(T.C.).ManufacturesWordMark/Name Engraved/Embossing/Screenprintingon housing.OEM musthaveitsowninhouseNABLlabsetupforalltesting facilitiesfor LEDfixtures. (LM79&LM80)certificate/ Report from OEM shall be submitted.All as per pre approvedbyEngineerincharge. Foradditionaltechnical parameters of products/ work, refer Annexure A attachedwith this BSR . 43 1200mm , Min. Lumens output 2000 lmLED Tube rod withPolycarbonate Housing 44 Providing&Fixingof BEE Starratedcopperwounded double ball bearing capacitor start, aluminium body & Metallic bladeceiling fan Conformingtoallthe performancerequirementslaiddowninIS374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineerincharge. Foradditionaltechnicalparametersof products/ work, refer Annexure A attached with this BSR. 45 1200 mm Sweep BEE3 Starrated (service value >=5.0 to<5.5 ) 46 Providing & Fixing ofof Double ball bearing, copper wounded capacitor startsingle phase metallicblade fresh air fan, in existing opening including cost of hardware , flexible 3 corecopperconductor,makingconnections,testingetc.as required. All as per pre approved by Engineer in charge.For additionaltechnicalparametersofproducts/work ,referAnnexure A attached with this BSR . 47 225 mm sweep 48 Providing&LayingP.V.C./XLPEinsulated&P.V.C. sheathedArrmoured Aluminium cableconfirmingto IS:1554P-I/IS:7098P-Iof1.1KVwith H4-Gradeelectrolytic aluminiumconductorconfirmingtoIS8130of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(withcabletie)including testingetc.asrequiredof followingsize.OEMmusthaveitsowninhouseNABL accrediatedLaboratoryfortestingprocedureasper IS:10810.Foradditionaltechnicalparametersofproduct/work refer Annexure A attached with this BSR 49 120.0 Sq. mm 50 a) 3.5 core 51 70.0 Sq. mm 52 b) 3.5 core 53 50.0 Sq. mm 54 c) 3.5 core 55 35.0 Sq. mm 56 d) 3.5 core 57 10.0 Sq. mm 58 e) 4 core 59 6.0 Sq. mm 60 g) 4 core 61 Supplyandinstallationofhigh tensile low carbon steel rod molecularlybondedwith99.9%Copper thickness(250 microns)and confirmingto UL467,IS/IEC62561-2 of following size and length and as per point mentioned (a), (b),[c), (d), (e) below :- 62 (a) Bore a hole of dia. 100 mm of required length, Place therod in the centre of Hole 63 (b) filledwithanticorrosive conductive compoundswith the permanent sealings at both the ends, CPRI/ ERDAtested with RMS capacity ofminimum 30 KA for withstanding 1 second .To ensure the moisture content and electrical conductivity, 25 kg for2000 mm & 50 Kgs for3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. The compound shall be tested form NABLacredeatedlab forlow resistivity(lessthan0.12 Ohm - meter ) & high conductivity in nature with carbon as a majorcontent asperreferanceofIS3043-1987,IEEE80- 2013(clause14.5d),IEEE837&IER1956withlatestamendemnts 64 ©ConnecttherodwithcopperStrip/Conductor/Wirewithsuitable clamp made from tinned copper and SS 304 Bolt 65 (d) Place Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load5000KgormoreofsizeTopDia.225to260mm,Bottom Dia 300 to 350 mm. and Height250 to 300 mm. 66 (d)Testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visitand ensure to enter in measurment book. 67 (e)Testcertificates forconfirmingabovestandardsfrom OEMismandatory.Allasperpre approved by Engineerin charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 68 17.2 mm thick and 3 Mtr. Long 69 Supply&Layingfollowingsizeearthwireinhorizontalor vertical run in ground/surface/recess including riveting, soldering,saddles, makingconnectionwithGI/Cupurity purity >95%thimble etc. as required.All as per pre approvedbyEngineerincharge. Foradditionaltechnical parameters of products/ work, refer Annexure A attachedwith this BSR . 70 a) 8 SWG copper Wire 71 Providing&FixingofIK08,IP66protectedLEDStreet LightLuminaireonexistingbracket/pole.Fixturemadeof powder coated single piece pressure die cast aluminum materialwith heat dissipation finson housingwithUV stabilized PC (UV stablization report submitted for UV cover) /Toughened Glass coverand secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy>=125lm/wtandpotteddriver &hasauniqueBISR number withInput Voltage AC 120 to 270 V AC with High voltageCutoff@>=300VACandAutoresettingSafety, Power Factor >0.95 driverEfficiency >85%,THD(I) <10% Humidity10%to90%RHWorkingTemp-5Cto45C. driver current <750mA. The luminaireshall be BIS certified andTrademarkcertified.LifeExpectancy Equalormore than 50000 burning hrs with Minimum 70% lumen maintened, CRI >70 and CCT 5700K +355K. Surge protection shall be min≥4KVinternalandmin10KVexternalinsidedriver compartment.drivershouldbePhasetophaseprotectionof products/ work, refer Annexure A attached with this BSR.dwiththisBSR.charge. Foradditionaltechnical parameters of products/ work, refer Annexure A attached withthisBSR. 72 LED StreetLightfixture withMinimum lumenoutput3700lm 73 Providing&FixingofStreetlightbracketmadeoutfrom followingsizeof B class, MediumclassG.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp,Saddlessuitablefastnersetc.asrequired.Allasper pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attachedwith this BSR . 74 25 mm Dia. 75 SITCof 3/4 polecurrentlimitingMouldedcasecircuit breaker(MCCB)madeofflameretardent&heatresistant materialhaving following current rating, short circuit breaking capacityat 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with frontface and centralisedadjustable,tripfreemechanisum,truecontact position indicator,line load interchangeability,designed for bothhorizontal&verticalmountingwithoutanyadverse effectonelectricalperformance,suitableforoperationupto 55degreeandwithoutderatingupto40degree, pollution degree 3, having positive isolation capability, push(test) to trip, trip time less then 10 ms under s/c condition, Breaking capacityIcs=100%Icu.Uimp=8KV,ratedinsulation voltage 690 V. provision forUVR , shunt trip , earth fault trip,doorinterlock,padlock&rotaryhandle,including making connectionsetc. as required.OEM shall have submit NABL /CPRI /ERDA accrediatedlab type testcertificate beforeproducts/ work, refer Annexure Aattached with thisBSR.dwiththisBSR. charge. Foradditionaltechnical parameters of products/ work 76 4 pole MCCB With Thermal Magnetic release 77 160 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 78 upto100Amp,25kA,adjustableO/L&adjustableS/Csetting, 79 250 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 80 SupplyingandfixingofAluminium(IEC60105ISO209- 1,2) / Copper (IEC 60028) bus bar by means of SMC / DMC type insulatorwith standard short circuit withstand capacity, high tensile nuts and bolts spring washers in existing panel includingbending,cuttinginrequiredshapeandsizeand colourcodingwithheatshrinkablePVCsleeves.Allasper pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attachedwith this BSR . 81 Electrolytic grade Aluminium bus bar 6010 grade 82 Providing & Fixing ofding dong/musical chime bell as per PWDspecificationforelectricalWorks,includingmaking connection testing etc. as required.All as per pre approved by Engineerincharge. Foradditionaltechnicalparametersof products/ work, refer Annexure A attached with this BSR. 83 P&F metal clad / Plastic industrial plug top & socket unit with pin and sleeve type contact on porcelain/ bakelite base in Recessed/surface mounting heavy duty Enclosure made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. powder painted (without MCB) including making connections, testing etc.as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 84 6.13.1) 20 amp, 2 pin + scrapping Earth, 1 Module 85 Providing & Fixing ofISO certified company made on load change over switch, front handle operated, four pole 415 V as perPWDspecification forelectricalWorksconformingto IS/lEC 60947-3 : 1999 including connections , testing etc. as required .in the following rating.Appropriate type test certificate /OEM testreportshall be submitted .All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attachedwith this BSR . 86 Open execution type 87 125 A 88 SITC of IP-42 and general construction confirming to IS:8623:1993,wall/freestandingfloormounteddustand vermin proof compartmentalisedcubical panel as specifications andOther parameters requiredas per point (a),(b), (c),(d), (e), (f), (g), (h) as below:- 89 (a)ThicknessofCRCAsheetshall be2.0mm, cablealley compartmentshavingconcealedhingedtypedoorswithkey type lock with / withoutdetachable extension type structure. Removable 3 mm. thick sheet steel gland plates withappropriate size of knockouts for cables shall be provided 90 (b)completepanelshallundergoaprocessofdegreasing, Waterrinsing,Activation,derusting, picklinginacidbath, phosphatising &shall be subjected to nine tankprocess and thenPowdercoatedwithapprovedshadeofminimum70 micronsonbothside ofpanel. ThepanelhavingPEfoam/ Neoprenerubbergasketof notlessthan3mmthickness,requiredhardware,concealedhingeddoorwithkeytype lockingarrangementforequipment/switchgearearthedwith2.5 sq.mm braided copper wire. 91 [c) Interconnectionbetweenbusbarandswitchgears/cable shallberigidlysupportedandmadeoutbyflexiblecopper wires(upto63amp)andbysolidbusbar (>63amp). control wiring will be carried out with 1.5 Sq.mm, Earth wire with 2.5 Sq.mm and CT with 2.5 sq.mm flexible copper wire only.All joints / interconnections of copper bus bar shall be dullytinned.Clearancebetweenmainbusbarandrisers/ metal parts shall be at least 10 mm additional to width of bus barBusbarisinsulatedbyHeatShrinkablesleeves.Earth and Neutral bus bar shall be half of the size of phase bus bar. ( Cost of Bus bar/ Flexible wire for Interconnection betweenMain busbar and Switchgearis to be Paid Extra ) 92 (d)Wiring betweencomponentswithinswitchgearand Incoming / outgoing cableshall be done through the terminal blockonly.Directconnectionshallnotbepermitted.Each terminal block shall be one piece moulded, barriertype, 650 volt grade, complete with washers, heads, studs with two nuts andidentificationstripsandshallhaveadequatecontinuous currentrating. Fortap-offs, adjacentterminalswith shorting stripsshallbeused.10%Spareterminalblocksshallbe provided.Wireidentificationonmarkingstripshall correspond to the designation of the wiring diagrams. All wire terminals on the equipment shall also be marked withdesignation corresponding to those of the wiring diagram. 93 (e)All wiring shall be enclosed in plastic channels and neatly bunchedandclosedinmeteringchamber,Wiringbetween terminals of various devices shall be ‘point to point’ (no wire splitting ortee connections)withwires neatly trucked along theback of thepanels, adequatelysupported topreventsagging. 94 (f)FloormountedpanelshallbemountedonBaseframeofISMCchannel size 100 x 50 x 5 mm( to be paid Extra ) 95 (g)Tests:Theinsulationresistance(with1000VMegger) and High voltage Power frequency test (by applying a voltage of 2.5KV for one minute) shall be measured between phases, between phase and neutral and between phase and earth. both beforeandafterhighvoltagepowerfrequencytest.The insulation resistance shall not be less than three megaohm. CT Secondary current injection test shall also be carried out. 96 (h)only outer surface area on all sides shall be measured & paneltobefabricatedonlyfromCPRIapprovedfabricator only(CPRITestcertificatestobesubmitted)Allasperpre approvedbyEngineerincharge.Foradditionaltechnical parameters of products/ work, refer Annexure A attachedwith this BSR . 97 Providing & Fixing of BIS approvedCurrent Transformeras per PWD specification for electrical Works ,ISI marked as per IS2705-1992/conformingtoIEC60044-1,withsecondary terminal ofCTshallbebroughtoutsuitabletoaterminal block which shall be easier accessible for testing and terminal connection,withallnecessarysupportinexistingpanel includingconnectionetc.asrequired Currenttransformer Ring Type Tape Wound/Resin Cast Wound as per IS 16227 with, Accuracy Cl, CT ratio and burden as specified. ISF<=5, Cucrosssectionofsecondarywire1.5sqmm(minimum), includingallnecessarysupportinexistingpanelincluding connectionetc.asrequired.Allasperpreapprovedby Engineerincharge.AllasperpreapprovedbyEngineerin charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 98 Ring type tape wound CT 99 C T Class 1, Ratio upto 150/5, Burden 5 VA 100 Providing &Fixing ofIS:13875&IEC:61326confirming LEDDigitaltype (upto 500)Vrange Voltmeter/Direct- Ammeter/ CToertatedammeter/Frequencymeter/KWH meter/MultiFunctionMeter/Poweranalyzerofclass1 accuracyas per IS : 1248 of size 96mm x 96 mm including making connection by PVC insulated copperconductor with PVCsleeves/channeletc.asrequired. Allasperpre approvedbyEngineerincharge.Foradditionaltechnical parameters of products/ work, refer Annexure A attachedwith this BSR . 101 Three phase with universal Auxiliary supply + AMP + HZ + PF+KW+KVA+KVAR+KVARH+KWH+DUAL ENERGY+ ENERGY+THD-I, THD-V & RUN HRS+ MDwith RS485 102 Providing & Fixing of 110/220 V, unibody LED Indicating lamp IEC 60947 with integral circuit, IP65 above panel & IP 20 terminal block, Approx. body dia for panel not less then 20 mm, length min. 50mm, front LED cover dia min.29 mm, contact material phospher bronze for Led, PCB contacts shall be ofbrass (tin plated), impulsedielectric tested for 2.5 KV, Ratedinsulationresistance shallbe 100M ohmat500VDC including connection etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR. 103 Red/yellow/Green colour 104 Providing & Fixing of IP-20 LED Recessed / Surface Mounted, Round / SqaureSMD Mid Power LED Downlight withpowercoateddie-castaluminumhousing withUV StabilizednonyellowishDiffuserwith BIScomplience2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% . System Lumen efficacy of≥ 110 lm /watt, THD < 10 %, Pf.≥0.95, CRI >80,life time of minimum50000 Burning Hours with , 70% of intial Lumenmaintanedtilllifeends ,CCT3000°K/4000°K/ 5700°K/6000°K/6500°K(AsperANSIBin),maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate(T.C.).ManufacturesWordMark/Name Engraved/ Embossing/ Screen printing onhousing. 105 OEMmusthaveitsowninhouseNABLlabsetupforall testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attachedwith this BSR . 106 Surface Mounting (with extruded alumn. Housing ) 107 Minimum lumen output 1950 lm 108 SITCofMonoblockmotorpumpsetISImarked(IS:9079- 2002)withTEFCmotor,motorshouldbeIE2classasper IEC 60034-2-1: 2007, IEC 60034-30: 2008,&IS12615:2011.withStainlesssteelImpellor,Stainlesssteel shaft,Mechanicalseal,Single/Threephase(240-440V) permanentsplitcapacitortype(PSC),fittedwiththermal overload protection, Including cost of hardware etc on existingplatformcomplete.PumpshallhavefollowingHP Rating,phase,Head,minimumDischargerespectively completeinallrespect.OEMshallhavesubmit NABL/ CPRI/ERDAaccrediated labtypetestcertificatebefore execution. All as per pre approved by Engineer in charge.For additionaltechnicalparametersofproducts/work ,referAnnexure A attached with this BSR . 109 1.0 HP, 1-Ø, (10-120)Mtr, (30-12) LPM 110 Supply & Fixing of Dry Powder Agent (as per IS 4308:2019), ABC typeFire Extinguisher (Stored Pressure type) conformingtoIS:15683:2018,PowdercoatedInternal& ExternalSurfaceDeepdrawncylinderbodyofMildSteel CR2 grade conforming to IS: 513, Squeeze grip Forged brass releasevalvewithInbuiltsafetyreleasedevice,Diaphragm Type, 0 to 28 bar range pressure gauge, 450 mm long EPDM dischargetube,QRcodeforProductTraceabilityincluding Fixing on wall with suitable Anchor Fasteners as required of followingcapacity.TestCertificatesofalltheParameters alongwithHydrotest&Bursttest(ForCylinderBody) Certificatefrom OEM / External NABL Accrediated Lab is tobesubmitted.AllasperpreapprovedbyEngineerin charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 111 4 kg 112 Providing & Fixing of Vertical(BEE 5 star rated) / Horizontal( BEE 3 star rated) storage water heater with outer casingmadeofEngineeringPlasticsheet(Upto25Ltr)/ Metal rust proof Body (35 & 50 Ltr), Glass - line / Titanium EnamelcoatedPressurePumpCompatible8barpressure Inner tank, Glass Line Coated , mineral filled heating element, stem type, snap actionadjustable thermostat , Dual indicating lamps Injected PUF insulation, Multi Function Valve etc. as requiredheldinpositionwith2/4no.10/12mmanchor Fastener, duly wired with 3 core 2.5/4.0 Sqmm PVC insulated &sheathedcopperconductorand16A/25Athreepinplug top with PortableResidualCurrent Device( PRCD ) , including making inlet, outlet Flexible alloyconnection, testing etc. as required. All as per pre approved by Engineer incharge. Foradditionaltechnicalparametersofproducts/ work, refer Annexure A attached with this BSR . 113 15 Ltr. 114 SITC ofContactorOEM Fabricated DOL/Star-Delta Starter panelwithswitchgearselectionasperType-2Cordinatiom Chartand madeoutfrom1.6mmthickpowdercoated CRCAsheet,enclosurecomprisingofoverloadprotection relay,shortcircuit&singlephasingprotection,Illuminated ON/OFF pushbuttons, ammeter,voltmeter,indicating lamps etc.suitable for following rating motors complete in all respect. All as per pre approved by Engineer in charge.For additionaltechnicalparametersofproducts/work ,refer Annexure A attached with this BSR . 115 For single phase Submersible / Monoblockpump 116 0.5 HP to 1.5 HP (DOL starter) 117 Supplying and drawing PE Insulated & PVC Sheathed unarmoured telephone cable with 0.5 mm dia. Solid Annealed electrolytic grade bare Copper Conductor as per IS: 8130/84 &confirmingtoTECspecificationGR/WIR/06-03March 2002in existingsurface or recessed conduit/casing capping. includingferrulingoneachpairforIdentificationetc.as required.Foradditionaltechnicalparametersofproduct/ work refer Annexure A attached with this BSR 118 2 pair 119 P & F Krone module with base framein the recess / surface madeoutof1.2mmthick sheetsteelbox,frontopenable, havinglockingarrangementsdulypowderpainted,including dressing,ferruling and punching oftelephonecablewith kronetooletc.asrequired.Foradditionaltechnical parameters of product / work refer Annexure A attached withthis BSR 120 10 Pairs 121 Providing&Fixingofflushtype nonmodularsingleline telephone jackmade out fromindustrial grade Polycarbonate orfireresistantABSmaterial,includingmaking connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 122 Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copperwire insulated with PVC, UTP(Unshielded Twisted Pair),Category6,ClassE,100OhmImpedance,Indoor CableasperlatestammendmentsofANSI/TIA/EIA-568, Thecopperconductorsshouldbebalancedtwistedinpairs, seperated by a cross-member fluted pair divider& protected by PVCJacket. Certified performancein a4-connector configurationupto 100Mtrschannelrequirements& transmission frequencies up to 250 Mhz. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack & ferrulingatbothendsforidentificationwithnecessary toolsforpunching,stripping,crimpingandtestingetcas requiredcomplete inallrespect.Allasperpre approved by Engineerincharge. Foradditionaltechnicalparametersof products/ work, refer Annexure A attached with this BSR. 123 SupplyandInstallationofunsheilded/360degreesheilded Informationoutletsmadeofhighimpactplasticbodywith ABS,FRGradehalogenfreematerialwithprovisionfor protection against dust in jack, suitable for Cat 6/6A application complying to latest ammendments, According. to Cat.6/6Achannel,Itshouldsupportchannelaswellas components requirements of Cat.6/6A standards at frequenciesofupto250to500Mhz.Cat6/6A unshielded/shieldedJackshouldbesuitabletoterminate4 pair,23/24AWGsolid/strandedwirediameters,using100 Ohm unshielded/shielded balance twisted pair cable, the jack should have tooless/impact termination on reliable copper tin plated Insulation displacement contact, with easy lock mechanism,ItsupportsIEC60603-7-4andcompliedwith ANSI/TIA/EIA 568 C.2 standard. jack should be RJ11,RJ12 & RJ45 compatible. Should support Ethernet 1.2 Gb/s ATM,Digitalvideoandbroadband/basebandanalogvideo, Voice over internet protocal (VOIP) Specifications in existing modular/MS Bo products/ work, refer Annexure A attachedwiththisBSR.dwiththisBSR. charge. For additionaltechnicalparametersofproducts/work ,refer Annexure A attached with this BSR . 124 Cat 6, Un-sheilded Information Outlet 125 Supply&fixingofsquareFaceplateforFlush/Surface MountInformationOutletsSingle/DualorQuadAperture, material should bePC+ABS body, Suitable for RJ45 unshielded/shieldedconnectionmodules.ShouldmatchwithI. O. OEM. Dimensions should be 86mm X 86mm as required complete in all respect.All as per pre approved by Engineer incharge. Foradditionaltechnicalparametersofproducts/ work, refer Annexure A attached with this BSR . 126 Single Aperture 127 Supply&InstallationofIP-20&IK-08,ULListed Wall mountedDoubleSectionCommunicationenclosure (Rack) made from powdercoated (60 to 80 Micron) CRCA sheet, front sturdy sheet steel frame folded from one piece and weldedwithminimum5mmtoughenedglassdoor,Vertical MountingRail1.6MMwithUMarking,withAllround protectivechannelonthedooraperture,lockintegratedon frontdoor,topandbottomcoverwithcable entry provision with gland plates, integrated side walls, 2 pair of19 angles with wall mounting provision on wall. Accessories like: 1 No of 19 1U Horizontal Cable manager, 1 No of 90 cfm 230V AC Fan with 1 mts long cable, mounting hardware , 1 No of 191U, mountable socketstripswith 5nos of5A universal sockets with 2 mts long power chord for supplying power to switches,fansetcalongwithearthcontinuitykit,indicator, mouldedpowersupplycable.fixingonwallwithSuitable Anchorfastner etcasrequired.Allasperpreapprovedby Engineer in charge.For additional tec products/ work, refer Annexure A attached with this BSR . d with this BSR . 128 6 U Rack with Width 600 mm &Depth 400 mm + 100 mm 129 Supply,Installation,&Testingof191URackMounted/ surfacemountedaluminum/CRCA1.2mmpowdercoated, Singlemode glass FiberOpticCable Patchpanel/LIU loaded with flangless/screwable duplex adapters for ST/E- 2000/SC/LC/MT-RJ/PC type, It should have easy removable Topplatewithpushbuttons,thereshouldbeasplicetray installedinthePatchpanel/LIUwhichcanhandlethefiber cores,splicetrayshouldbePC+ABSmaterial,itshould includeaccessorieslikemountinghardware,gormetts,heat shrink tubes/sleevs, screws, nutsto installthe panelfor rack/wallmount applications as per requirment complete in all respect. All as per pre approved by Engineer in charge.For additionaltechnicalparametersofproducts/work ,referAnnexure A attached with this BSR . 130 12 Ports 131 Supply , Installation, Testing and Comissioning ofManaged Layer-2Intelligent10/100EthernetSwitchproviding24x 10/100/1000MBPSGigaEthernetports/withmin2SFP Giga Ports (provision for Fiber Giga connectivity) with related LAN Base Software including making connections etc asrequired.AllasperpreapprovedbyEngineerincharge. For additional technical parameters of products/ work, referAnnexure A attached with this BSR . 132 Providing&FixingofIP20,2x2LEDSurface/Recessed mountingMidpowerSMDtype LEDLightfixturenotless than50mmhousingdepthmadefromCRCAsheetsteel housing,highpurity/transmisivityUVstabilizedNon- yellowish diffuser for uniform light distribution. High efficiencywith4KVinternal/externalsurgeprotectionBIS certified isolated driver having efficiency > 85% , with Short & Open circuit protection(Integral with light fixture). Systemlumenefficacyof≥120lm/Watt,THD<10%, p.f.≥0.95,CRI>80, lifetimeofminimum 50000Burning Hours with , 70%ofintial Lumen maintaned till life ends, CCT3000°K/4000°K /5700°K/6000°K/6500°K(AsperANSI Bin), maximum powerconsumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/Name Engraved/ Embossing/ Screen printing onhousing. 133 OEMmusthaveitsowninhouseNABLlabsetupforall testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR. 134 Surface Moutning 135 Minimum lumen output 3600 lm 136 Supply & fixing of GI pipes confirming to IS : 1239 P - 1 ( 2004 ) with flanges duly screwed & welded including rubber washer, nuts & bolts of 8mm dia complete in all respect.All as perpreapprovedbyEngineerincharge. Foradditional technicalparametersofproducts/work ,referAnnexureA attached with this BSR . 137 B class 32mm dia 138 Supply , Installation and Testing of 4 pair, 100 Ohm impedance,Cat6/6A/ClassE/Eapatchcordsshouldbe constructedofminimum 23/24AWG, strandedbare Copper cablewithFRPVC/LSZHJacket,withanenhanced performance by factory moulded RJ45 connectors with strain reliefbootsasperANSI/TIA/EIA568-C.2suitableforCat 6/6A application complying to latest ammendments Category 6/6AStandards,According.to TIA568C.2,ISO/IEC11801, EN50173,IEC60603-7-51,EN60603-7,IEEE802.3anminimumrequirement for1GBASE-Tto10GBASE-T performance. Patch cords shall be straight thru cable compatiblewithbothT568-AandT568-Bwiringschemes, should support IEEE 802.3af / IEEE 802.3at for POE applications,Minimum750to1000matingcyclesinplug contactsforlongdurability,ShouldsupportEthernet 10GBASE-T, 1.2 Gb/s ATM, Token ring 4/16, Digital video andbroadband/basebandanalogvideo,Voiceoverinternet protocal(VOIP).AllasperpreapprovedbyEngineerin charge.For additional technical parameters ofuct/accessories from OEM shall be submitted. All as per pre approve 139 Cat 6, U/UTP (Unscreened/Un-sheilded Twisted Pair)Patch Cord 140 1 Mtr 141 P& F in position frame made outofM.S. angle (riveted or welded)finishedwithtwo coatsofredoxide andtwo coats enamelpaintincludingcutting,welding,holesetc.of following sizes as required.For additional technicalparameters of product / work refer Annexure A attached with 142 35mm x 35mm x 5mm 143 P& F paper phenolic resin bondedlaminates confirming to IS:2036- 1995forboxes/frames including making holes for switches etc, with brass screws, washers/ zinc platednut and bolts as required. Foradditional technical parameters ofproduct / work refer Annexure A attached with this BSR 144 6.4 mm thick 145 ProvidingandfixingofIP65protectedPolycarbonate/ Polysterenefuseboxmouldedwithinsideknockoutsof followingsizewithhingedcover,transparentwindow, PU gasket,lockingarrangement,dulyholdedwith2nos.pole clampsof20mmx 3mmflatwithnutandbolts,The box shall be provided with Din rail, 4 / 8 way 10.0 / 16.0sq.mm heavy duty connector, earth terminal,complete in all respect. All as per pre approved by Engineer in charge.For additional technicalparametersofproducts/work ,referAnnexureA attached with this BSR . 146 160 mm X 225 mm X 100 mm 147 Providing&FixingofIK08 IP65protectedTop/Bottom mounted LEDPost topLuminariemadeof singlepiece constructionpowder coated die cast alluminium housing with UVstabalizedClear/frostedPolycarbonatediffuserand Aluminiumanodisedwithsandblastreflector.The System level Luminous efficacy ≥100 Lumen/W. SMD LEDs is to beused,SystemCRI>70,CCT:3000/4000/6500K.The integral electronic driver must be potted & has a unique BIS Rnumbermustbepotted&hasauniqueBISRnumber constant current and Internal/external surge protection device ofmin.4KV(L-N) andefficiency>85%,PF>0.9, THD<10%andinputVoltagerangeof140-270VACat 50Hz.Systemlifeof50000Burninghourswith70%of Initial Lumens maintained . Driver current <750mA.Fixture mustbeincompliancewithBISStandardsandTrade mark Certificate complete in all respect.OEM Must have its own in houseNABLlabsetupforalltestingfacilitiesfor LED fixtures.(LM79/LM80) Certificate/ report with liable warrantyofproduct/accessoriesfromOEMshallbe submitted.AllasperpreapprovedbyEngineerincharge. For additional technical parameters of products/ work, referAnnexure A attached with this BSR . 148 Minimum lumen output 2500 lm Post top Luminarie 149 Providing&FixingofElectrical insulating rubbermattsas per PWD specification for electricalWorks, ISImarked confirmingtoIS:15652/ 2006 withoneside antiskid abberationmarksandpastingthematwithsyntheticrubber adhesive as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 150 11 KV,Class B 2.5 mm thick with proof voltage 22 KV AC(rms) and Break Down Voltage45 KV AC (rms) 151 Supplying and making one end termination with Nickel plated heavy duty brass single compression gland (as per IS 12943- 1990))SIBGtypeconsistingofCheckNut,GlandBody, Metal Washer(3 Nos.), Outer Seal Rubber Ring, CompressionNut, heavydutyaluminiumlugs(asperIS 8309 -1993) duly crimped with crimping tool, PVC tape as per IS8337-1976 of followingsizeof PVCinsulated& PVCsheathed/XLPEaluminiumconductorcableof1100 volt grade as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 152 b) 4 x 6.0 sq.mm 153 c) 3.5 x 50.0 sq.mm 154 d) 3.5 x 35.0 sq.mm 155 f) 3.5 x 120.0 sq.mm 156 Providing & Fixing of 240/415 V Residual current circuit breaker (RCCB) conforming to (IS:12640-1)/ IEC 61008 -1 , rated 4 KV impulse withstand voltage truly current operated and shall operate on CBCT mechanisum, provision for pad lock,min. operation 10,000 upto 63 A rating and5000 for 100 Aratingand minimum phase termination capacity of 35 sq.mm. rigid wire, IP 20 contact protection with existing distribution board / sheetincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 157 6.5.2) Two pole 100/300mA sensitivity 158 6.5.2.2) 40 A rating 159 6.5.2.3) 63 A rating 160 Part B AC work 161 Supply,Installation,TestingandComissioningof Inverter type Air Cooled Hi Wall split type Air conditioners with latest starratingsystemasperBEEamendeduptodatecomplete with Indoor unit(IDU), Out door unit (ODU), surface/ concealedcopperRefrigerantpipingwithinsulation(closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDUtoODU),copperpowercableupto3.5Mtr(IDUto ODU), R-32/R-410 Green Refrigerant, wireless Remote control, suitable for working between 230V +/- 10% with low & high voltage cutoffand50 hz , single phaseACsupply capableofperformingcooling,dehumidification,air circulation of following capacity with Scroll / rotary compressor.Allasperpre approvedby Engineerincharge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 162 1.5 TR ISEER not less then 3.8 163 2.0 TR ISEER not less then 3.8 164 Providing &Fixing ofIS:4985-2000Class-4(10Kgf/ Sqcm)UPVCdrainwaterpipingwith fittings(IS:7834& 10Kgf/sqcm) like elbow, socket, Tee, solvent cement jointing, support with MS hanger on ceiling or recessed in wallwith chasing & plastering with 6 mmthickclosedcell elastomeric nitrile rubberinsulation including leakage testing etc.asrequiredoffollowingNominalsizes.Allasperpre approvedbyEngineerincharge. Foradditionaltechnical parameters of products/ work, refer Annexure A attachedwith this BSR . 165 25 mm 166 Supply & fixing MS powder coated stand suitable for 1.0/1.5/2.0 Tr outdoor type of Split AC.All as per pre approved by Engineerincharge. Foradditionaltechnicalparametersof products/ work, refer Annexure A attached with this BSR. 167 Makingholeinstonemasonary/RCCwall/RCCslabwith core cutter for accomodating refrigerant pipe/ drain pipe/ MSpipe/ cables etc of following dia 168 150 mm dia per running inch length 169 Supply, Fixing and testing of following capacity ISO certified company made wall mounted stabilizer having output voltage variationfrom200Vto250V(+/-5%)withinputvoltage variation from 170 V to 260 V, time delay facility from 2 to 4 minute and high cutoffat270 V with providing of16 Amp/20 Amp Industrialplug top making connection etc complete in all respect.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, referAnnexure A attached with this BSR . 170 4 kVA 171 5 kVA