}

Tender For Supply And Fixing Of Street Light Poles At Sardarshahar Urban - Supply And Erection Of Galvanized Iron Pole With Galvanizing Done In Single Dipping (Average Coating Thickness Minimum 65 Microns) Continuously Tapered Poles Having Octagonal/ Circ, sardarshahar-Rajasthan

Department Of Local Bodies has published Tender For Supply And Fixing Of Street Light Poles At Sardarshahar Urban - Supply And Erection Of Galvanized Iron Pole With Galvanizing Done In Single Dipping (Average Coating Thickness Minimum 65 Microns) Continuously Tapered Poles Having Octagonal/ Circ. Submission Date for this Tender is 08-09-2025. Street Lighting Tenders in sardarshahar Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

51057007
Tender For Supply And Fixing Of Street Light Poles At Sardarshahar Urban - Supply And Erection Of Galvanized Iron Pole With Galvanizing Done In Single Dipping (Average Coating Thickness Minimum 65 Microns) Continuously Tapered Poles Having Octagonal/ Circ
Tender
Indian
Rajasthan
Sardarshahar
08-09-2025

Tender Details

Tender For Supply And Fixing Of Street Light Poles At Sardarshahar Urban - Supply and erection of Galvanized Iron pole with galvanizing done in single dipping (Average coating thickness Minimum 65 Microns) continuously tapered poles having Octagonal/ Circular cross sections designed to withstand the maximum wind speed as per IS 875, The pole shaft shall be made from sheet steel (HT Steel Conforming to grade S355JO) and confirming to BSEN 10025 and shall be continuously tapered with single longitudinal welding. There shall not be any circumferential welding. The welding of pole shaft shall be done by Submerged Arc Welding (SAW) process. pole shafts shall be provided with the rigid flange plate of suitable thickness (Fe 410 conforming to IS 226 IS 2062) with provision for fixing 4 no. foundation bolts, This base plate shall be fillet welded to the pole shaft at two locations i.e. from inside and outside. The octagonal Poles shall have lockable door of approximate 500 mm length at the elevation of 500 Imm from the Base plate with bakelite sheet having 6A SP MCB and 16 sqmm stud typе connector (4 nos) inside the pole at door opening for cable connection of following length and dimension as per table P-01 with base plate and foundation bolt on the Existing cement concrete foundation. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR. Poles with Octagonal Cross Section. 9 Mtr. 2 Supply and Fixing of Pole OEM fabricated hot dipped galvanised M.S. Overhang (48.3 X 3.25 mm) with cap (400 x 88.9 / 114.3 x 3.25 mm) over the existing poles. All as per pre approved by Engineer in charge. For additional technical parameters of products work, refer Annexure A attached with this BSR. Double arm overhang 3 Providing and Laying RCC Foundation for Octagonal / Conical Street Light poles, High mast Poles as per Drawing attach at Table P-4 with Following Procedure & All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR 4 A) Excavation of Pit for Foundation Size upto required depth from Ground level 5 B) Dressing of Pit and Dry stone pitching 200 mm thick including supply of stones and preparing surface complete 6 C) Providing and laying in position cement conerete of M-10 grade of 75 mm thickness 7 D) Reinforcement for R.C.C. work with TMT bars including straightening, cutting, bending, placing in position and binding all complete. 8 E) Centring and shuttering including strutting, propping cte, and removal of form work for Footing and Pedestal 9 F) Providing & Fixing of 2 no. Required Size PLB HDPE Pipe & Foundation Bolt with template as per OEM Recommendations. 10 G) Providing and Laying Reinforce cement Concrete of M-25 grade in Footing and Pedestal including Curing the foundation for 7 days. 11 H) Providing and Fixing Nosing Angle 40 mm x 40 mm x 6mm with 2 no. 100 mm long, 10 mm dia. Lugs on each face. 12 Pole Foundation for Octagonal pole from 7 Mtr. To 9 Mtr. 13 Providing & Fixing of IK08, IP 66 protected 1 FD Street Light Luminaire on existing bracket pole. Fixture made of powder coated single piece pressure die cast aluminum material with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover) /Toughened Glass cover and secondary lens on cach LED & should be SMD type of 3 to 5 watt each. The System efficacy >-125 Im/wt and potted driver & has a unique BIS R number with Input Voltage AC 120 to 270 V AС with High voltage Cutoff @>-300 V AC and Auto resetting Safety, Power Factor >0.95 driver Efficiency >85% ,TID(1) 70 and CCТ 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs. Manufactures Word Mark/Name Engraved Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in-charge. For additional technical parameters of products/work, refer Annexure A attached with this BSR 14 LED Street Light fixture with Minimum lumen output 25000 Im 15 Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Un-armoured Copper cable confirming to IS:1554 P-1/IS :7098 P-1 of 1.1 KV with electrolytic grade Copper made of copper rods confirming to IS 613-1964, of purity >99.7%, Inner / outer sheath confirming to IS:5831 in existing RCC/Hume/ Stoneware / PVC pipe/ open duct/cable trench/Cable tray (with cable tie) including testing ete. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810 For additional technical parameters of product/ work refer Annexure A attached with this BSR. 4.0 Sq. mm. mm 3 core 16 Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Arrmoured Aluminium cable confirming to IS:1554 P-1/IS :7098 P- I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner/ outer sheath confirming to IS:5831 in existing RCC/ Hume Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size. OEM must have its own in house NABL acerediated Laboratory for testing procedure as per 1S:10810.For additional technical parameters of product/ work refer Annexure A attached with this BSR. 16.0 Sq. mm. 4 core 17 Add Extra in item no. 60.1 to 60.4 for Laying Charges for cable through Vermeer machine by making pit at regular interval and repairing the pit after laying of cable with PCC/ Bitumin as required. 18 P/L of Double wall corrugated HDPE pipe confirming to IS: 16205 P-24, Stiffness Class 750 N, Externally corrugated and having smooth surface inside with HDPE Coupler, Elbow, Tee at required Depth below the ground for laying cable of following Nominal Outer dia. MFR Test report from NABL accrediated is to be submitted.(Excavation of Earth & Back filling with compaction is to be Paid Extra)All as per pre approved by Engineer in-charge. For additional technical parameters of products/work, refer Annexure A attached with this BSR. 90 mm 19 Plate Earthing as per IS:3043 with copper Earth plate of purity >95% of size 600mm 600mm x 3.0mm by embodying 3 mtr. below the ground level with 20 mm dia. G.I. B class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing ofearth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensure to enter in measurment book. All as per pre approved by Engincer in-charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR 20 Supply & Laying following size earth strip in horizontal or vertical run in surface by means of Earth strip DMC Insulator including riveting/ soldering/ welding, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip)/GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required.All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work refer Annexure A attached with this BSR. 20mm x 3mm Alum. Strip 21 Supplying and making one end termination with Nickel plated heavy duty brass single compression gland (as per IS 12943-1990)) SIBG type consisting of Check Nut, Gland Body, Metal Washer(3 Nos.), Outer Seal Rubber Ring, Compression Nut, heavy duty aluminium lugs (as per IS 8309 -1993) duly crimped with crimping tool, PVC tape as per IS 8337-1976 of following size of PVC insulated & PVC sheathed/ XLPE aluminium conductor cable of 1100 volt grade as required.All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR. 4 x 16.0 sq.mm 22 Supplying and making one end termination with Nickel plated heavy duty brass single compression gland (as per IS 12943-1990)) SIBG type consisting of Check Nut, Gland Body, Metal Washer(3 Nos.), Outer Seal Rubber Ring, Compression Nut, heavy duty Copper lugs (IS 8337- 1976) duly crimped with crimping tool, PVC tape for following size of PVC insulated & PVC sheathed/ XLPE copper conductor cable of 1100 voltgrade as required.All as per pre approved by Engineer in-charge. For additional technical parameters of products/work, refer Annexure A attached with this BSR. 3 x 4.0 sq.mm 23 MAIN CUBICAL PANEL / STREET LIGHT CONTROL PANEL 24 P/F testing & commissioning of kiosk type weather proof out door main cubical panel size 750 mm X 1250 mm X 500 mm (app.) made out of 14 gauge MS sheet front and back both side openable duly hinged door withlocking arrangement by providing both side held draft and all required hard wares. The cubical should be dust and vermin proof followed by coat of zimpholite primer and finally two coats of enamal gray paint. The cubical should be mounted with hard ware on angle iron frame size 50 X 50 X 6 mm and 1500 legs duly painted framed be grouted 750 mm below ground level with cement concrete 1:3:6 in 1000 X 500 X 600 mm and providing brick masonary along angle iron frame above G.L. They shall be in two section... Following 25 (i) Providing & Fixing 415 V ,TP combination double break HRC switch fuse unit .100 Amp. rating for incoming supply with HRC fuse 100 Amp rating and of BCH/L&T/EE/Siemens/ ABB make. 26 (ii) Providing fixing timer switch TSQ 100 series 240 Volts, and full runningservice standred mounting with base of L & T or equivalent make including the cost of contactor 63 amp. 50 Hz. 440/400 volt. 27 (iii) P/F open busbars 25mmX3mm of required length duly covered by heat shrinkable sleeves with busbar supporters 28 (iv) Provision for residual current operated 63 Amp. 1 Pole ELCB of 30MA to 300 MA sensitively as required including making connections etc.(EE/Load stop make) 29 (v) P/F 2 Nos. 415 Volts TPN combination double break switch fuse unit,63 Amp. Rating with HRC fuses (EE/mds/ SCHNEIDER beh/Siemens ) for outgoing cable and making connection etc, also to have a provision for two nos, above switchs 30 (vi) P/F of 3 nos. RYB phase indicator resitance type complete with lamp,P/F of HT danger plate of size 200 X 150 mm made of aluminium sheet 20 gauge. 31 (vii) P/F cable glands double compression type and Al. lugs duly crimped for incoming cable and out going Cables 32 (viii) Providing 2 Nos. earth terminals including lugs and H/W duly interconnected with 8 SWG copper wire 33 (ix)Inter connection of main busbar to each out going switch and cable terminal shall be with 4 sqmm PVC copper conductor duly crimped with AL lugs 34 (x) Cable termination shall be fixed at backside of the panel with H/W and [spring washers 35 (xi) Light control switch with photo senser complete unit as required (SOR- |2017 ) (Rate = 57948/- After 16.35% increase = 67422.498)

Key Value

Document Fees
INR 500 /-
Tender Value
INR 49.25 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail