| 1 | Civil Work and supply of Related articles |
| 2 | Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete |
| 3 | Distempering with 1st quality acrylic distemper, having VOC (Volatile Or ganic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour.13.41.1 including water thinable coat with cement primer having VOC conent less ten 50gram / ltr. |
| 4 | Distempering with 1st quality acrylic distemper, having VOC (Volatile Or ganic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour.13.81 |
| 5 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : One or more coats on old work |
| 6 | Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. |
| 7 | 20 mm cement plaster : 1:4 (1 cement : 4 coarse sand) |
| 8 | Mirror polishing on marble work/Granite work/stone work where ever required to give high gloss finish complete |
| 9 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- chargeDismenting of rcc |
| 10 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. |
| 11 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. 15.2.1 Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix |
| 12 | Demolishing stone rubble masonry manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge : |
| 13 | Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge. |
| 14 | Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in-Charge: All kinds of soil |
| 15 | Extra for levelling & neatly dressing of disposed soil completely as directed by Engineer-in-charge |
| 16 | \" Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. 16.78.1 With material conforming to Grade-I (size range 75 mm to 0.075 mm) having CBR Value-30\" |
| 17 | Providing and laying kerb stone made up of red sand stone of size 0.30 x 0.30 x 0.10 mtr in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). |
| 18 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level 1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size) |
| 19 | Coursed rubble masonry (first sort) with hard stone in foundation and plinth with : Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 20 | Coursed masonry with all dressed sides and to be masoned in cement mortar with hard stone (First sort) in super structure above plingth level up to lfloor five level (masonry work Cement mortar 1:6 (1 cement : 6 coarse sand ) with 40% new stone and 60% site collected) |
| 21 | Laying old cement concrete interlocking paver blocks of any design/ shape laid in required line, level, curvature, colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineerin-charge. (Old CC paver blocks shall be supplied by the department free of cost). |
| 22 | Providing and laying 60mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved s;ze, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge |
| 23 | Providing and laying 80 mm thick factory made cement concrete interlocking green paver block of M -35 grade made by block making machine with strong vibratory compaction, of approved s;ze, design & shape, laid in required colour and pattern over and including |
| 24 | Providing and laying matt finished vitrified tile of size 300x300x9.8mm having with water absorption less than 0.5% and conforming to IS: 15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-inCharge. |
| 25 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : 6.4.1 Cement mortar 1:4 (1 cement : 4 coarse sand |
| 26 | \"Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately) : 30 mm thick Red sand stone - Exposed face machine cut and table rubbed with rough backing \" |
| 27 | 40 mm thick rubbed stone flooring over 20 mm (average) thick base of cement mortar 1:5 (1 cement : 5 coarse sand) with joints 3 mm thick, side buttered with cement mortar 1:2 (1 cement : 2 stone dust) admixed with pigment to match the shade of stone and pointing with same mortar. 11.30.1 Red sand stone |
| 28 | \" Stone work, plain in copings, cornices, string courses and plinth courses, upto 75 mm thick in Cement mortar 1:6 (1 cement : 6 coarse sand), including pointing with white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade. 7.32.1 Red sand stone\" |
| 29 | Providing and placing in position 100 mm thick factory made machine batched & machine mixed Precast RCC Rectangular Covers on drains of footpath of various sizes, of M-25 grade cement concrete for RCC work, including cost of centering, shuttering, reinforcement of 8 mm dia TMT bars of Fe 500 grade @ maximum 100mm c/c on both ways , neat cement punning on finished surface, properly encased on all edges with 1.6 mm thick , 100 mm wide MS sheet duly painted over priming coat , reinforcement to be welded at edges with MS sheet and providing 2 Nos. 12 mm dia bar for hooks etc i/c cost of cartage, all leads & lift, handling at site etc. all complete as per direction of Engineer-in-Charge\" |
| 30 | Renewing glass panes, with putty and nails wherever necessary including racking out the old putty: 14.5.2 Float glass panes of thickness 5 mm \" |
| 31 | Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer\"s specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with :12.5 mm thick tapered edge gypsum moisture resistant board 12.45.3\" |
| 32 | Providing and fixing 35 mm thick factory made laminated veneer lumber door shutter conforming to IS : 14616 and TADS 15:2001 (Part B), including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws, all complete as per directions of Engineer- in-charge and panelling with panels of 12 mm thick one side Pre-laminated particle board (decorative lamination on one side and other sides balancing lamination) grade -1, medium density flat pressed, three layer particle board FPT - I or graded wood particle board FPT-1 conforming to IS : 3087 bonded with BWP type synthetic resin adhesive as per IS : 848 and prelaminated conforming to IS : 12823, Grade -1, Type II marked : |
| 33 | Provision for providing and fixing of plumbing and electrical articals required to revival of fountain at c.center quila rai pithoda (i) Brass nozzel 1 inch dia |
| 34 | L.E.D colored fountain lights 27 watt |
| 35 | change over |
| 36 | PVC gate valve 1 inch |
| 37 | 4 core 1.5 Sqmm copper wire |
| 38 | 3 core 4 Sqmm copper wire |
| 39 | 7.5 Hp motor crompton |
| 40 | Labour charges for repairing of fountains |
| 41 | Provision for providng and applying plumbing and electrical articals (i) copper wire 3core 1.5 Sqmm |
| 42 | copper wire 4 core 4 Sqmm |
| 43 | Unbrekable Bathroom Vanity Cabinet & Washbasin Set/Washbasin with Cabinet/Basin Cabinet for Bathroom with Mirror (White) for vip toilet (material used -Glass, Ceramic and HPP , dimesion 62.5D x 47W x 54H Centimeters) |
| 44 | Celing LED Lights with frame 6inch 9 wt |
| 45 | Celing LED Lights with frame 8inch 15 wt |
| 46 | Slimline Ultra LED Tube light 20W / Cool Day Light / ceiling lights as per approved design |
| 47 | MCB 10amp |
| 48 | MCB 63amp |
| 49 | MCB 125amp |
| 50 | wall mounted fan 12 inch |
| 51 | PVC Exaust fan 12 inch with fram |
| 52 | MCB box pannel (0.6 x0.9 m) |
| 53 | Rectangular shape (plain bevelled edge ) 1500x450 mm Mirror with Plastic moulded frame |
| 54 | S.S signage board of required size |
| 55 | Retro Reflective Vinyl Prints for Information boad (5x3 ft ) |
| 56 | Sun board sheet (2x 2x2.5m + 2x3.5x2.5m) |
| 57 | water tank 1000ltr triple layered |
| 58 | S.S tray for wires including all fittings |
| 59 | 3 seater cast iron benchs |
| 60 | 120 lit. Green plastic dustbin with wheels of approved design |
| 61 | Labour charges for electric fittings |
| 62 | MCCB 250 Amp 4 pole |
| 63 | PVC hose pipe 50 mtr |
| 64 | SS. Rod accessories for handicap toilet block & other assemblies of required size |
| 65 | Urinal pot with fitting for VIP toilet block ( hinware/ jaguar/ parryware / or equivalent |
| 66 | Submersible Pump 1HP With Control Panel Single Phase, Multicolor( kirlosker or equ) |
| 67 | Exhaust Fan 18 inch |
| 68 | S.S dustbin 10 lit in required colour |
| 69 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid |
| 70 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 18.7.2 20 20 mm nominal outer dia Pipes |
| 71 | Providing and fixing CP Brass Health faucet with SS flexible hose & wall hook of approved quality & make and as per the direction of Engineer-in-charge. |
| 72 | Providing and fixing CP Brass soap dish of approved quality & make and as per the direction of Engineer-incharge |
| 73 | Providing and fixing CP Towel Ring of approved quality & make and as per the direction of Engineer-in-charge |
| 74 | Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) with flange of approved make and quality as per direction of Engineer-in-charge |
| 75 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible pipe 32 mm dia |
| 76 | Providing and fixing CP grating of approved quality: Circular type 150 mm nominal dia |
| 77 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately). 9.1.1 Second class teak wood |
| 78 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.8.2.2.2 Area of slab over 0.50 sqm ,Granite stone slab colour black, Cherry/Ruby red |
| 79 | Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.8.3.2 Granite work |
| 80 | Providing and fixing factory made solid Foam uPVC profile for kitchen cabinet frame (45 x 20 mm) of approved shade, quality and make. The profile shall be laminated on both sides, made from rigid foam sheets (Single extruded) having density 600 Kg/cum and the exposed edges sealed with PVC edge beading of same shade and colour. The frame shall be fire retardent with necessary screw holding capacity. Frame shall be fixed to wall using Expendable Fastener with necessary stainless steel screws, all complete as per direction of Engineer-in-charge. |
| 81 | Providing and fixing factory made Kitchen Cabinet Shutter/Partition 20 mm nominal thickness of approved shade, quality and make, made from rigid foam sheets (Single extruded) having density 600 Kg/cum and laminated on both side by laminate Sheet/PVC foil lamination. The exposed edges shall be sealed with PVC edge beading of same shade and colour. The shutter shall be fire retardent having necessary screw holding capacity. Shutter shall be fixed to frame using approved hinges with necessary stainless steel screws, all complete as per direction of Engineer-in-charge |
| 82 | Provision for providing and fixing electrical articals required to illuminate the pathway from fountain to entry gate of c.center at quila rai pithoda (i) Aluminium 3 core 16 Sqmm |
| 83 | copper wire 3core 1.5 Sqmm |
| 84 | Modern Norse Cylindrical Outdoor Bollard Light - For Garden, Pathways & Landscape Lighting 15wt (pillips /harold/ or equ, ) as per approved design |
| 85 | 40 dia PVC pipe for cable casing under earth |
| 86 | Labour charges for above lights |
| 87 | Anti-termite spraying in the whole building of museum including ground floor, stores and all galleries, woodwork panels, wardrobes, shelves, wooden cupboards, door and window frames, walls etc with following anti termite treatment components and anti termite chemical |
| 88 | Disposal of moorum/building rubbish/ malba/ similar unserviceable, dismantled or waste material by mechanical transport including loading, transporting, unloading to approved municipal dumping ground for lead upto 10 km for all lifts, complete as per directions of Engineer-in-charge |
| 89 | Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. |
| 90 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete |
| 91 | Provision of repair GI/Aluminium gutter inside c. center and roof area after checking leaks, addressing damage, and ensuring proper water flow include patching holes with flashing and sealant, sealing joints with silicone or sealant, and potentially replacing sections of the gutter or downspout upto the hieht of 10mt from ground |
| 92 | Providing and fixing stone jali 40 mm thick throughout in cement mortar 1:3 (1 cement : 3 coarse sand), including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment, matching the stone shade, jali slab without any chamfers etc. 7.33.1 Red sand stone |
| 93 | Constructing masonry Chamber 120x120x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : 18.35.1 With common burnt clay F.P.S.(non modular) bricks ofclass designation 7.5 |
| 94 | Cleaning of chocked sewer line by diesel running vehicle mounting hydraulic operated high pressure suction cum jetting sewer cleaning machine fitted with pump having 4000 litres suction capacity and 6000 litres water jetting tank capacity including skilled operator, supervising engineer etc. for cleaning and partial desilting of manholes and dechocking of sewer lines. Dechocking and flushing of sewer line from one manhole to another by high pressure jetting system of 2200 PSI for sewer line from 150mm dia upto 300mm dia for all depth. |
| 95 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-incharge. (Note:- Butt hinges and necessary screws shall be paid separately)Second class teak wood 35 mm thick shutters |
| 96 | Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°C, 0.87- 0.89 kg/ litre and viscocity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc, and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 650/ 450N/5cm. Tear strength in longitudinal and transverse direction as 300/250N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer ofmembrane : 14.91.1- 3 mm thick |
| 97 | painting with synthetic enamel paint/Duco Paint of approved brand paint : 13.61.1 Two or more coats on new work |
| 98 | Providing and fixing precoated galvanised iron profile sheets (size shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.\" |
| 99 | Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-incharge complete. 21.8.1 Upto 5mm depth and 5 mm width |
| 100 | provision of providing water proofing sheet/canvas/polister over C.Center central dome ncluding cutting sheets to size and shape wherever required of approved shade charges as directed by enginer inchage |
| 101 | Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after .The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineerin-charge .The elevational area of the scaffolding shall be measured for payment purpose .The payment will be made once irrespective of duration of scaffolding. Note: - This item to be used for maintenance work judicially, necessary deduction for scaffolding in the existing item to be done. |