Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 20-09-2025 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 27-09-2025 |
| Sl. No. | Item Description |
| 1 | Note:- Work will be carried out upto 4th storey of bldgs and quoted rates of items shall be deemed to include the cost ofnecessary formwok and scaffolding required as per site conditions. |
| 2 | Complete removal of existing water proofing roof treatment of any description including under layer, taking down of cement plaster,concrete and mud pushka of any thickness including grubbing up of trees and removal of debrisfrom site to a place outside defence landand clean the surface of roof with water & remove dust complete all as specified and directed. |
| 3 | M&L for 50mm thick plain cement concrete 1:2:4 type B-0 (using 12.5mm gradedcrushed stone aggregates) as in padding mixed with liqued water proofing compound, laid to required slope over roof finishing ,finished even & fair complete all as specified and directed. Note :-(i)PCC padding shall be turned around into covering at all vertical projection above roof upto a height of 150mm.(ii) Water proofing compound shall be measured and paid separately |
| 4 | M&L for rendering 15mm thick in cement mortar 1:4 mixed with water proofing compound on roof surfaces , surface finished even and fair complete all as specified and directed. Note:- water proofing compound will be measured and paid separately |
| 5 | Supply only liquid water proofing compound. |
| 6 | M&Lforwater proofing treatment inthe following sequences:-(a)Applying 1st course of bituminous primer confirming to IS-3384 @ 0.4 Kg/sqm .Cover the surface till the surface properly impregnated and insolvent oil primer evoporate completely.(b) Applying 2nd coat of blown 85/25 graded bitumen confirming to IS 702 @ 1.2 Kg/sqm.(c) Applying 3rd course of APP (Atactic Polypropylene) modified polymeric membrane 3 mm thick weight not less than 3.6 Kg/sqm with 160 Grams/sqm non woven polyster made at centre core reinforced laid with 75 mm side overlap and 100 mm overlap. The membrane has to belaid with LPG torch and overlap sealed and finished neat complete all as specified and as directed (d) Complete treatment to be carried out by authorised applicator of waterproofing manufacturer. |
| 7 | M&L for applying two coats of aluminum paint@ 200ml/sqm over the APP membrane complete all as specified and directed. |
| 8 | Taking down shuttern. exc 1.0 sqm each and removing from site complete all as specified and directed. |
| 9 | Taking down shutter exc 1.0 sqm and n. exc 2.0 sqm each and removing from site complete all as specified and directed. |
| 10 | Taking down chowkats or frames with shutter (without taking off shutter from the frame) n. exc 1.5 sqm each including cutting holes for taking out hold fast or dismantling brick work and removing from site complete all as specified and directed. |
| 11 | Taking down chowkats or frames with shutter (without taking off shutter from the frame) exc 1.5 sqm & n. exc 4 sqm each includingcutting holes for taking out hold fast or dismantling brick work and removing from site complete all as specified and directed. |
| 12 | S&F pressed steel frames of size 125mm x 60 mm made out of size 1.25 mm thick MS sheet for doors with one or more rebates including mild steel hinges, 100 mm long , medium weightand 25 mm x 3 mm flat iron as in hold fast , tie bar including necessary fixing lugs, lock strike plate and fixing arrangement and making good the disturbed surfaces in cement mortar 1:3 or cement concete 1:2:4 type B-1 including PCC 1:3:6 type C1 as in back fill to chowkats complete all as specified and directed. |
| 13 | S&F pressed steel frames of size 105mm x 60 mm made out of size 1.25 mm thick MS sheet for doors with one or more rebates including mild steel hinges, 100 mm long , medium weightand 25 mm x 3 mm flat iron as in hold fast , tie bar including necessary fixing lugs, lock strike plate and fixing arrangement and making good the disturbed surfaces in cement mortar 1:3 or cement concete 1:2:4 type B-1 including PCC 1:3:6 type C1 as in back fill to chowkats complete all as specified and directed. |
| 14 | S&F 35 mm thickfactory made 2nd class hard wood, plain, framed, panelled shutters (two panels) with lock rail and panel of 9mm thick BWP commercial plywood .The size of rail and stiles as per IS: 1003(Part-1), kiln seasoned and chemically pressure treated, fitted to chowkats complete all as specified and directed. |
| 15 | S&F factory made 35 mm thick 2nd class hard wood, glazed and skeleton shutters, open rebated and prepared to receive glass, gauze etc divided into squares with plain, chamfered or rounded, mitred and rebated sash bars ,any numbers sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); fitted to chowkats complete all as specified and directed . |
| 16 | M&L for 35mm thick factory made flush shutters, solid core construction with block board core and plywood face panels commercial type on both sides complete all as specified and directed. |
| 17 | S&F solid PVC door frame of size 50mm x47mm made out of 5mm plain colour PVC sheet reinforced with mild steel square tube, supplying and fixing in opening as per specifications and drawing including making good to distributed surface of walls complete all as specified and directed. |
| 18 | S&F factory made solid panel PVCdoor shutter 30 mm thick ( style ) consisting of frame work made out of MS tubes for top and bottom rails MS frame shall be covered with heat moulded plain colour P.V.C‘ C’ channelhaving a PVC sheet strip 20 mm width struck inside with solvent cement for stiles and plain colour PVC sheet for top rail lock rail and bottom rail on either side and as gap inserts for top rail; and bottom rail paneling of plain, colour PVC sheet to be fitted in the MS frame welded / sealed to the stiles and rail with suitable PVC sheets beading and jointed together with solvent cement S&F in frame at site as per specification. |
| 19 | S&F Factory made solid PVC moulded door shutter, with particle board core, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thickMoulded prelam PVC Sheeton the front face & 2mm prelam PVC Sheet on back face, supplying & fixing in frame at site as per specification & drawing all as specified and directed |
| 20 | Taking down of old/unserviceable kitchen cabinet/cupboard including all fixture and fitting, complete all as specified and directed.Note:- For measurement superficial area in elevation shall be measured. |
| 21 | S&F PVC board 18mm thick,one side UV printed designing and back side plain colour printed for cup board or kitchen cabinet with self ,drawer,shutter and frame full size fitted under cooking platform and other platform including fittings etc complete all as specified and directed. |
| 22 | S&F pressed steel cup board frame of size 60mmx40mm, made out of mild steel sheet 1.25mm thick with rebate 20mm wide and 12mm deep and making good the disturbed surfaces in cement mortar 1:3 or cement concete 1:2:4 type B-1 including PCC 1:3:6 type C1 as in back fill to chowkats complete all as specified and directed. |
| 23 | M&L for prelaminated MDF board (exterior grade) 19 mm thick as in shutters /shelves ,prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work including lipping (15mm thick three sides and 20 mm thick lipping hinge side around the shuttercomplete all as specified and directed. |
| 24 | S&F stainless steel handle, 100mm size complete all as spcified and directed. |
| 25 | S&F in repair continuous (piano) hinges,30mm width, heavy duty, mildsteel ,bright finish or electrogalvanised suitable for 19mm thick shutter complete all as specified and directed |
| 26 | S&F 100mm long stainless steel butt hinges, fixedwith screws complete all as specified and directed |
| 27 | S&F aluminium anodised barrel tower bolts, 200mm long of extruded section, fixed to doors with screws complete all as specified and directed. |
| 28 | S&F aluminium anodised , fabricated type handle 125mm size complete all as spcified and directed. |
| 29 | S&F aluminum alloy, anodised, sliding door bolt of length 250mm with hasp and staple (bolt type) and fixing clips of sheet, cast or extruded section and fixing bolt and sliding bolts of extuded sections or cast aluminum alloy and fixed complete all as specified and directed. |
| 30 | S&F aluminium powder coated (coating not less than 50 micron) door frame and door shutter,door frame of hollow section 101mm x 44.0mm x thickness not less than 1.53 mm & hollow section of stiles of glazed shutter 85mm x 44.45mm x thickness not less than 1.56mm having grooves for aluminium beading and top rail of hollow section 83.5mm x 44.45mm x thickness not less than 1.50mm, lock rail of hollow section 83.5mm x 44.45mm x thickness not less than 1.50mm and bottom rail of hollow section 114.3mm x 44.45mmx thickness not less than 1.50mm ,one derived handle 300mm long,100mm long butt hinges - 4 Nos, aluminium floor type hydraulic door closer, aluminium mortice lock 65mm, 4 levers of Godrej pattern ,glazing with select quality tinted glass 5mm thick andrubber packing, aluminium beadingcomplete all as specified anddirected. |
| 31 | S&Faluminum powder coated (coating not less than 50 micron)window and ventilator shutters, side hung type, without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, necessary glazing and locking arrangements anodised aluminium fittings such as peg stays 150mm long (1 No.). hinges type B-21 100mm long (2 Nos.) suitable handle (1 No.)complete all as specified anddirected |
| 32 | Taking down wall panelling including aluminium door,windows and partitions in any position complete all as specified anddirected |
| 33 | S&F in repair door closer hydraulically regulated, Aluminium (extruded section body), designation No 1, universal type suitable for door shutter upto 700mm in width and weight not more than 35 kg complete all as specified and directed. |
| 34 | S&F in repair double action floor spring hydraulically regulated made up of minimum 1.25mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made out of mild steel heavy duty & fixed complete all as specified and directed. |
| 35 | S&F in repairbrass mortice lock, vertical type, size 100 mm, 4 levers complete all as specified and directed. |
| 36 | M&L for factory made box type steel windows, double shutter,outer frame made out ERW TUBE \"P section (65x45x25mm) and shutters of ERW TUBE \"P\" section (50x35x20mm) openable shutters side hung including pintle hinges with two nos MS tower bolts 150mm size on each shutter, steel handleand stopper of \"Z\" section as specified complete with sash bars dovetailed or welded ready for glassfixing and wire gauzed fixing with suitable fittings/opening for cooler/AC where required .Steel windows will be double shutter (external glazed and internal wire gauzed) complete all as specified in Drg No CEPZ/TD/-324/07 of sheet No 1/3 to 3/3 complete all as specified and directed. Note: - The quoted rate shall be deemed to include:-(i) Provn of onecoat of coal tar on the ends of steel frame in contact with brick/conc surface(ii) 04 Nos MS steellugs of MS flat 20 x 5mm& 20 cm long over all welded to frames (iii) PCC block for embedding lugs. |
| 37 | M&L for framed work such as grills , gratings etc with ends of bars shouldered and /or riveted or forged into spikes , framed guard bars, barred iron doors, ladders, framed balusters: walk ways , railings frame work of water tanks and similar work confirmingto Fe290, Gde E-165 complete all as specifiedand directed |
| 38 | S&F in repair 15mm bore Bib taps, cast copper alloy fancy type chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed. |
| 39 | S&F in repair angle valve with flange ,cast copper alloy , fancy type, chromium plated, screwed down for high pressure with crutch or butterfly handle, screwed both ends for iron pipe of 15mm bore complete all as specified and dircted. |
| 40 | S&F in repair pillar taps, swan neck, chromium plated, fancy type, cast copper alloy with capstan heads, screwed down high pressure with or without lettered \"Hot\" or \"Cold\" with long screwed shanks and fly nuts screwed for iron pipe of 15mm bore complete all as specified and directed. |
| 41 | S&F in repair health faucet (ABS Body) mild steel chromium plated suitable for 15mm dia pipe with 1.0 metre long flexible tube and ABS wall hook including making connectios and fixed in position complete all as specified and directed. |
| 42 | S&F in repair vitreous china wash hand basin, white, flat back of size 550x400mm including cutting for and pinning in ends of brackets or erecting stand including stainless steel brackets, brass chromium plated waste coupling 32mm bore, waste pipe HDPE 32mm bore complete all as specified and directed |
| 43 | S&F in repair 10 litres PVC, valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float 32mm PVC \"L\" bend and handle including brackets complete all as specified and directed |
| 44 | S&F in repair vitreous china wash down water closet pan (pedestal pattern) of size 520x360x390mm of approved colour including connection pipe to union of flushing cistern, inlet and overflow pipes, connecting only to flushing cistern, anti-syphonage pipe with PVC flush pipe of 32mm dia including plastic seat with cover, white in colour with mild steel chromium plated hinging and \"P\" or \"S\" trap device complete all as specified and directed |
| 45 | S&F in repair vitreous china squatting pan, Orissa pattern, size 580 x 440mm white with integral foot rest, cast iron \"P\" or \"S\" trap of size 100mm, including provision of plain cement concrete bedding and connection to trap and to flushing pipe, anti syphonage pipe etc and making good the floors complete all as specified and directed |
| 46 | S&F in repair PTMT grating , 100mm dia including embeding in tiles with white cement complete all as specified and directed. |
| 47 | S&F in repair PTMT grating with hole , 125mm dia including embeding in tiles with white cement complete all as specified and directed. |
| 48 | S&Fin repair PVC waste pipe 32mm bore for sink /WHB of required length complete all as specified and directed. |
| 49 | Taking up or down 15mm dia GI tubing and conncetions including cleaning for refixing or removal to store complete all as specified and directed |
| 50 | Taking up or down 20mm dia GI tubing and conncetions including cleaning for refixing or removal to store complete all as specified and directed |
| 51 | S&F Galvanised steel tubing, 15mm bore, medium grade with all fittings, fixed to wall/ceiling and laid in floorscomplete all as specified and directed |
| 52 | S&F Galvanised steel tubing, 20mm bore, medium grade with all fittings, fixed to wall/ceiling and laid in floorscomplete all as specified and directed |
| 53 | Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc and brushingsurface with neat cement slurry with 3.0 kg of cement per sq.metre and removing unserviceable material outside defence land complete all as specified and directed |
| 54 | M&L for glass fibre reinforced modified cementitious coating system before the final coat of Latex Shield 2K (or equivalent).Base coat: Berger HS Latex plus (or equivalent) both on wall (upto 1 mtr min height) and floor.Consumption base coat: 0.3 kg/sqmReinforcement: Glass fiberSecond and Third coat: Latex sheild 2K (or equivalent) both on wall (upto 1 mtr min height) and floor.Consumption top coat: 3 kg/sqmSystem requirements: density: 2.00 kg/ltrcompressive strength: 0.5 N/mm².• Wall penetration through the RCC slab must be sealed using Berger HS RepirO(or equivalent).• Intersection of base slab with wall must be provided with a 50 mm fillet using Berger HS Latex plus(or equivalent) modified mortar with a bonding coat of Berger HS Latexplus(or equivalent) modified cement slurry upto 5ft.• All depressions, unevenness, surface honeycombing shall be repaired using Berger HS Latex plus (or equivalent) modified polymer mortar with a bonding coat of Berger HS latex plus(or equivalent)modified cement slurry including cleaning ofRCCsurface to remove dust, loose particles, etc with compressed air or any other suitable technique depending on site conditions, grinding any sharp edges, complete all as specified and directed . |
| 55 | M&L for rendering 15mm thick in cement mortar 1:4 including mixing ofwater proofing compound on brick work or concrete surfaces, surface finished even and smooth without using extra cement complete all as specified and directed. Note : Water proofing compound shall be measured and paid separately as supply only. |
| 56 | S&F 20 mm dia High density polyethylene pipes (HDPE) of pressure rating 6 kgf/cm2 laid in as spoutto pour out residual water out from the treated areacomplete all as specified and directed . |
| 57 | M&L for hard core of gaugenot exceeding 63mmusing broken stone or boulders,deposited, spread and leveled in layers not exc 15cm thick, watered and rolled/rammed to a true surfaces complete all as specified and directed . |
| 58 | M&L for plain cement concrete 1:4:8, type D-2 (using 40mm graded crushed stone aggregates) as in foundation, filling & mass concrete complete all as specified and directed. |
| 59 | M&Lfor 25 mm thick cement concrete 1:2:4,type B-1, (using 20 mm graded crushed stone aggregate) as in floors, finished even and faircomplete all as specified and directed. |
| 60 | Dismantiling of AC/ steel /fibre (corrugated, semi-corrugated, etc.) sheets in roof coverings complete all as specified and directed |
| 61 | S&F Pre painted galvalume aluminium zinc coating (AZ-150 micron) GI basedcorrugated steel sheet 0.5 mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall fixed with self tapping screws complete all as specified and directed . |
| 62 | S&F Pre painted galvalume aluminium zinc coating (AZ-150 micron) GI basedplain steel sheet 0.5 mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall fixed with self tapping screws complete all as specified and directed. |
| 63 | DismantlingWall and ceiling boards (fibre,pulp, insulation) or insulation boards/ slabs/ blankets, any thickness, including cover fillets etc complete all as specified & directed. |
| 64 | S&FGI snap grid frame work (Grid size 60.5cm x 60.5cm) for false ceilingconsisting of main runner \"T\" of size 24mm x 32mm and 0.3mm thick , Secondary runner \"T\" of size 24mmx25mm and 0.3mm thick,GI angle24mmx24mm and 0.4mm thick,Bottom exposed capping of width 24 mm of all T-sections shall be of 0.25mm thick PPGI, hot dipped galvanised steel with zink coating not less than 120gm / Sqm ,ceiling grid system duly suspended by 4mm dia GI wire hanging from existing purlins /roof slab with butterfly clipsincluding Gypsum ceiling tilesof size 595 x 595 x 7 mm laminated with 0.07 mm thick polyvinyl film on the face side and 10 micron metalized polyester film on the back side fixed on GI snap gridcomplete all as specified and directed . |
| 65 | Dismantling floor, hearth or wall tiling including cement mortar bedding, terrazo dado from wall surface(but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed. |
| 66 | M&L for 7 to 8mm thick non skid coloured ceramic tiles (square/ rectangular) of size 400mmx400mm, in floors etc, set and jointed in neat cement slurry and poined in white or coloured cement to match the colour of tilescomplete all as specified and directed. |
| 67 | M&L for 7 to 8mm thick non skid coloured ceramic tiles (square/ rectangular) of size 400mmx400mm,as in vertical surfaces, set and jointed in neat cement slurry and pointed in white or colored cement to match the colour of tilecomplete all as specified and directed. |
| 68 | M&L for 7 to 8mm thick non skid coloured ceramic tiles (square/ rectangular) of size 300mmx300mm, in floors etc, set and jointed in neat cement slurry and poined in white or coloured cement to match the colour of tilescomplete all as specified and directed. |
| 69 | M&L for 7 to 8mm thick non skid coloured ceramic tiles (square/ rectangular) of size 300mmx300mm,as in vertical surfaces, set and jointed in neat cement slurry and pointed in white or colored cement to match the colour of tilecomplete all as specified and directed. |
| 70 | M&L for 8 to 9 mm thick vitrified double charged ceramic,edge cut, joint less tiles (square/ rectangular) polished,area of each tiles exceeding 0.18 sqm but not exceeding 0.38 sqm , in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles complete all as specified and directed. |
| 71 | M&L for 8 to 9 mm thick vitrified double charged ceramic,edge cut, joint less tiles (square/ rectangular) polished,area of each tiles exceeding 0.18 sqm but not exceeding 0.38 sqm , as in vertical surfaces, set and jointed in neat cement slurry and pointed in white or colored cement to match the colour of tile complete all as specified and directed. |
| 72 | M&L for15mm thick screed bed or bedding layer in cement motar 1:6 for laying of tiles complete all as specified and directed. |
| 73 | M&Lfor 25 mm thick cement concrete 1:2:4,type B-0, (using 12.5 mm graded crushed stone aggregate) as in floors, finished even and faircomplete all as specified and directed. |
| 74 | M&L for glazed ceramic coloured tiles,450x350x7 mm thick or 350x250x7mm, as in vertical surfaces, set and jointed in neat cement slurry and pointed in white or colored cement to match the colour of tile complete all as specified and directed. |
| 75 | M&L for rendering 10mm thick in cement mortar 1:4on brick work or concrete surfaces, surface finished even and smooth without using extra cement complete all as specified and directed. |
| 76 | Dismantling of stone slabs and tiles of any description or thickness in floors, laid dry or pointed in any mortar complete all as specified and directed. |
| 77 | S&F machine cut granite stone slab in flooring 20mm thick,laid,bedded and jointed with grey cement slurry and pointed with white cement mixed with pigment to match the shade of the slab including rubbing,cutting andpolishing complete all as specified and directed. |
| 78 | S&F machine cut granite stone slab in vertical surfaces, risers of steps, 20mm thick,laid,bedded and jointed with grey cement slurry and pointed with white cement mixed with pigment to match the shade of the slab including rubbing,cutting andpolishing complete all as specified and directed. |
| 79 | Demolition of cement concrete (un-reinforced) ground floorand pavings n. exc 15 cm thickness (below or above ground level ) and removingthe rubbish from the work site out side defence premises complete all as specified and directed. |
| 80 | M&L for 75mm thick PCC 1:3:6 , type C-2 (using 40 mm graded crushed stone aggregate) as in plinth protection, laid in slope in 1:30 in alternative bays not exceeding 3 mtr in length. surfaces finished even and fairincluding raking out joints between panel to panel and panel to wall and plugging the same with bitumen mastic using bitumen and sand mixture in 1:3 complete all as specified and directed . |
| 81 | Demolition of brick work or stone/boulder masonry , built in cement mortar or cement lime mortar including all quoins, arches & pillars etc of any description and in any position and removingunserviceable material from work site to outside defence premises complete all as specified and directed |
| 82 | M&L for brick work with sub class \"B\" bricks, using old size bricks, straight or curved on plan exceeding 6m mean radius , built in cement mortar 1:6 complete all as specified and directed. |
| 83 | All as per Srl item No -82 here-in-before but except bricks complete all as specified and directed. |
| 84 | M&L for plain cement concrete 1:2:4 ,type B1(using 12.5mm graded crushed stone aggregates)as in lintels upto 1.5m clear span, window or door cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railing upto 60cm in height, copings,side posts of precast jallies etc. including slightly rounded or chamfered angles including necessary formwork complete all as specified and directed. |
| 85 | Taking down cement plaster of any description on brick or stone walls or from concrete surface including raking out joints, hacking for key, scrubing down with water etc and removing unserviceable material outside defence land complete all as specified and directed . |
| 86 | M&L for rendering 10mm thick in cement mortar 1:4 on brick work or concrete surfaces, surface finished even and smooth without using extra cement complete all s specified and directed. |
| 87 | M&L for rendering 5 mm thick in cement mortar 1:3 on ceiling, surface finished even and smooth without using extra cement complete all as specified and directed. |
| 88 | M&L for 2mm thick wall care putty on newly plastered wall surfaces complete all as specified and directed. |
| 89 | M&L for 2mm thick wall care putty on newly plastered ceiling surfaces complete all as specified and directed. |
| 90 | M&L for preparation of new plastered or unplastered surfaces of walls and applying three coats of white wash complete all as specified and directed. |
| 91 | M&L for preparation of new plastered or unplastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed. |
| 92 | M&L for preparation of new plastered surfaces of walls and applying two coats of oil bound distemper complete all as specified and directed.. |
| 93 | M&L for preparation of new plastered surfaces of ceiling and applying two coats of oil bound distemper complete all as specified and directed.. |
| 94 | M&L for preparation of new plastered surfaces of walls and applying two coats of cement base paint in camoflying pattern over one coat of primer complete all as specified and directed. |
| 95 | M&L for preparation of new plastered surfaces of walls and applying two coats of exterior emlsion weather proof paint over one coat of primer complete all as specified and directed. |
| 96 | M&L for preparation of old surfaces of ceilings including scraping by mechinised means; scrapping downsmoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots etc and washing with water and applying one coat of white wash complete all as specified and directed . |
| 97 | Hacking out old broken glass (any thickness, size, quality or description)from wooden/ metal frame including punching or drilling out old glazing pins/spring clips and providing and fixing new ones complete all as specified and directed. |
| 98 | M&L for 4 mm thick, plain sheet glass, ordinary quality and glazing with oil putty or with any type of beadsin squares n. exc 0.5 sqm each pane complete all as specifiedand directed. |
| 99 | S&F in repair galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and as directed . |
| 100 | S&F in repair door closer hydraulically regulated, Aluminium (extruded section body), designation No 3, universal type suitable for door shutter 851mm to 1000mm width and weight between 61 to 80 kg complete all as specified and directed. |
| 101 | Dismantling water tanksof capacity n.exc 500 ltrsand removing to store complete all as specified and directed . |
| 102 | Dismantling water tanksof capacity exc 500 ltrs but n.exc 1000 ltrsand removing to store complete all as specified and directed . |
| 103 | S&F Rotational moulded polyethlene water storage tanks of 500 litres capacity (cylindrical vertical with closed top) with plastic lid cover, hoisted and fixedin position including ball brass valves, high pressure, with polythene float and fly nut screwed for 20mm bore iron pipe complete all as specified and directed .. |
| 104 | S&FRotational moulded polyethlene water storage tanks of 1000 litres capacity (cylindrical vertical with closed top) with plastic lid cover, hoisted and fixedin position including ball brass valves, high pressure, with polythene float and fly nut screwed for 20mm bore iron pipe complete all as specified and directed .. |
| 105 | S&F in repair 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed |
| 106 | S&F in repair 25mm outer dia stainless steel decorative drapery rod of thickness 20gauge with stainless steel brackets near toends with stainless steelfinialsat both ends and necessary fittings complete all as specified and directed. |
| 107 | M&L for factory made precast designer Chequered cement concrete tiles 30cmx30cmx25mm thick, with grey cement and pigment, set ,jointed and pointed in neat cement slurry as in floors, laid over and including 20mm thick screed bed in cement mortar 1:4 complete all as specified and directed. |
| 108 | M&L for Precast factory made interlocking glazed top designer tiles, made in white cement and pigment base of thickness not less than 19 mm in different colour and pattern (compressive strength not less than 250 Kg/sqcm) set and jointed in neat cement slurry over and including including 15 mm thick screed bed in cement mortar 1:4complete all as specified and directed . |
| 109 | M&L for providing and laying 60 mm thick factory made charmfered edge cement concrete paver block of M-35 grade of approved colour, design & pattern as in foothpath, parks, lawns, drive ways or light traffic parking etc of required strength , thickness & size/ shape made by table vibratory method using PU mould, laid in required colour & pattern over and including 50 mm thick compacted bed of fine sand, compacting and proper embedding/ laying of interlocking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and directed. |
| 110 | M&L for 75 mm thick plain cement concrete 1:4:8, type D2 (using 40mm graded crushed stone aggregates) as in sub base complete all as specified and directed. |
| 111 | M&L Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and directed. |
| 112 | Dismantling timber scantlings (framed work)40 sq.cm and over in section, in any position complete all as specified and directed . |
| 113 | S&F rolled structural steel work as in roof trusses (framed), trussed, purlins, crane gantries rails and fastening and heavy bracket framing (beam, tee, angle channel or flat sections) including distance pieces, cleats etc confirmimg to Fe 290 (Gde E -165)complete all as specified and directed . |
| 114 | S&F rolled structural steel work as in main and cross beams, vertical posts,hip and jack rafters, purlins, plates (plain ) channels, square cut or notched etc used as stair step and balcony passagesconfirmimg to Fe 290 (Gde E -165)complete all as specified and directed . |
| 115 | S&F in repair waste coupling of chromium plated 32 mm dia with long screwed shanks and fly nutssuitable for wash hand basin complete all as specified and directed . . |
| 116 | S&F PVC frame made of 25 mm wide and 5 mm thick PVC battens, placed at 600 mm center-to-center (C/C) horizontally and vertically, securely fixed using solvent adhesive or screws as per manufacturer\"s instructions complete all as specified and directed . |
| 117 | S&F 7.5 mm thick prelaminated PVC panels ofapproved shade and design with tongue-&-groove joints over the PVC frame or wall, using solvent adhesive or screws,including necessary PVC beadings such as T-bead for mid-joints, U-profile for edges, and L-angle for corners as permanufacturer\"s instructions complete all as specified and directed . |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy