}

Tender For Provn Of Certain Major Revenue Works Under Ge (Af) Tech Area At Af Stn Agra, agra-Uttar Pradesh

Military Engineer Services has published Tender For Provn Of Certain Major Revenue Works Under Ge (Af) Tech Area At Af Stn Agra. Submission Date for this Tender is 26-09-2025. Electrification Work Tenders in agra Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

51040296
Tender For Provn Of Certain Major Revenue Works Under Ge (Af) Tech Area At Af Stn Agra
Tender
Indian
Uttar Pradesh
Agra
26-09-2025

Tender Details

Provn Of Certain Major Revenue Works Under Ge (Af) Tech Area At Af Stn Agra; 1 Surface excavation n.exc. 30 cm deep and averaging 15cm deep and getting out in soft/loose soil all as specified and directed 2 Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes,including forming bottom surface for laying of pipes/ cable etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed. 3 M&L forPCC (1:4:8) type D2 (using 40mm graded stone aggregates) as in foundation, filling and mass concrete complete all as specified and directed. 4 M&L forPCC (1:3:6) type C2 (using 40mm graded stone aggregates) as in foundation, filling and mass concrete complete all as specified and directed. 5 Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft/loose soil complete all as specified and directed. 6 Removing excavated material (soil) n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed. 7 Removing excavated material (soil) to a distance exc. 250m but not exc 500 m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed. 8 M&L forreinforced cement concrete M-25 Design Mix (using 20mm graded stone aggregates)as in footings, foundation, beam, plinth beams, bases for columns etc complete all as specified and directed. 9 M&L forreinforced cement concrete M-25 Design Mix (using 20mm graded stone aggregates) as in columns ,pillars, post and strut etc complete all as specified and directed. 10 M&L for use & waste of form work to sides of concrete foundations ,footings,bases of columns ,raft beams ,sides and sofit ( if any) of foundation and plinth beams and similar work or to betterrough finished surface of concrete etc complete all as specified and directed. 11 M&L for use & waste form work to sides of pillars, posts, strut, piers, columns and stanchions, square or rectangular on plan,finished the surface rough of concrete etc complete all as specified and directed. 12 S&F mild steel TMT bars 10mm dia and over cut to length bent to shape required, including cranking, bending, spirally for hooping for columns hooking ends and binding with mild steel wire anealed not less than 0.9mm dia or securing with clips complete all as specified and directed. 13 S&F mild steel TMT bars 6 to 8 mm dia in stirrups, cut to length bent to shape required, including cranking, bending, spirally for hooping for columns hooking ends and binding with mild steel wire anealed not less than 0.9mm dia or securing with clips complete all as specified and directed. 14 M&L for 15mm thick rendering in CM 1:4 on fair faces of brick work or concrete surfaces, finished the surface even and smooth (without using extra cement) complete all as specified and directed. 15 M&L for 10mm thick rendering in CM 1:6 on fair faces of brick work or concrete surfaces, finished the surface even and smooth (without using extra cement) complete all as specified and directed. 16 M&L for preparation of new surface of walls (external surfaces) and Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) in camoflage pattern, as per manufactures instructions etc complete all as specified and as directed. 17 M&L forPCC 1:3:6type C-2 ( 40mm graded stone aggregates), 75mm thick as in plinth protection, path, hard standing etc, laid in alternate by etc complete all as specified and as directed. 18 S&F steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS:1161- 1979 grade St.-240 including guddet plate, pole etc complete all as specified and as directed. Note :- Work shall be executed upto 10m height. 19 S&F Rolled mild steel work in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. conforming to Fe-410 (Gde E 250) quality Acomplete all as specified and as directed. Note :- Work shall be executed upto 10m height. 20 S&F Rolled mild steel work in plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment etc conforming to Fe-410 (Gde E 250) quality A complete all as specified & directed. 21 M & L for prepararing new or previously untreated steel surfaces of any description over 10 cm width or girth and applying two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. 22 S&F mild steel work in hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified & directed. 23 S&F Prepainted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall of any height, fixed with suitable J hook with bolts, washers etc complete all as specified & directed. 24 S&F Prepainted galvalume aluminium zinc coating GI based plain steel sheet 1.00 mm thick of an colour having tensile strength of 550 Mpa as in ridge of roof covering / cladding to wall, fixed with suitableJ hook with bolts, washers etc complete all as specified & directed. 25 M&L for Hardcore of broken stone or broken boulders of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed. 26 M&L for sand cushioning / filiing under floor or laid dry to the profile under interlocking block including watering and consolidation complete all as specified and as directed. 27 M&L for brick work with sub class B bricks (using old size bricks), straight or curved on plan, exc 6M mean radius, built in CM 1:6 complete all as specified and directed . 28 M&L for 75 mm thick PCC 1:3:6 type C-2 using 40 mm graded stone aggregate as in flooringetc, finished the surafce fair and even complete all as specified and directed 29 M&L for machine pressed precast concrete interlocking paver block of approved shape and size conforming to IS: 15658-2006 of 80mm thickness, with minimum compressive strength of 40N/sqmm (M-40 grade) without correction factor for chamfering, with grey cement and pigment complete all as specified and directed. 30 M&L for PCC 1:3:6, type C-1 (using 20 mm graded stone aggregate) as in kerbs stone, coping, apex stone, anchorage block of any scetion with plain fair face , rounded or chamfered on edges including weathering, slightly rounded or chamfered angles and throating complete all as specified and as directed 31 M&L for preparation of newly plastered surfaces of wall and applying two coat of distemper oil emulsion over a coat of primer complete all as specified and directed. 32 Supply, laying, testing GI tubing medium grade, laid in trences including required GI fittings complete all as specified and directed for the following bore :- 33 100 mm bore 34 80 mm bore 35 S&Fcast iron body sluice valve, ISI marked, class PN 1.6 and conforming to IS 14846 with stainless steel spindle complete all as specified and directed of following sizes :- 36 100 mm bore 37 80 mm bore 38 M&L for construction of brick masonry valve pit with sub-class B bricks (using old size bricks), built in cement mortar (1:6), of size (90 x 90 x 90) cm (internal dimension) with one brick thick walling and 150 cm x150 cm x 10 cm base foundation with PCC (1:3:6), type C2, cement plastering 10 mm thick with cement mortar (1:4) on internal & exposed surfaces, of brick work with andincluding MS cover of size 01mtr x 01mtr made out from 3.15 mm thick MS sheet with (50 x 50 x 5) mm angle iron framing, hinges and locking arrangement and paintingthe steel surfaces with two coats of synthetic enamel paint (first quality) over a coat of red oxide primer on MS cover and frame, inlcuding necessary excavation and earth work in any type of soil , returning , filling in approved soil disposal of surplus soil to a distance not exc.50 mtr ,complete all as directed. 39 M&L for cutting cast iron pipes of size 150mm bore in any position for insertion of new tees, branches, etc. complete all as specified & directed. 40 M&L for Bends any type, radius and angle tapers any type, straight, bend, increasing, decreasing or double socket, Tee pieces’ single branch. Y junction, double branch, cross all sockets or socket and spigot collars caps & plugs up to 150 mm bore complete all as specified & directed 41 M&L for Run lead joint for 150 mm bore dia CI pipe complete all as specified and directed 42 Taking down carefully aluminium/copper point wiring (light /fan / socket or power) complete including fitting fixtures such as switches, socket, ceiling rose, brackets, holders, bulk head/tube light fittingetc. and removing materials from site and making good disturbed surface of walls/ floors etc. complete all as specified and directed 43 M&L Point wiring for light/fanpoint controlled by one switch using approved colour coding as per IS, withFlame retardant Low Smoke And Halogen (FRLSH), smoke free, non toxic, non corrosive installation cable with UNILAY construction copper conductor 1.5 Sq. mm (nominal area), single core,insulated and unsheathed stranded cable 1100 Volts grade ISI-694 marked TEC and FIA approved in & including heavy duty, electric resistance welded (ERW) stove enameled surface Steel mounted conduit,heavy duty ISI marked as per IS:9557 (Part I) 1980 for four light points controlled by one Switch , includingFRLSH insulated unsheathed unitary construction copper conductor 1.5 Sq. mm nominal cross sectional area wire as earth continuity conductor up to common earth and connecting to earth dolly complete all as specified and directed. Note :- All conduit accessories such as bends, elbows, Tee etc shall be Flame proof certified by CMRS Dhanbad. 44 S&Ffluorescent tube light fitting 2x20W, 4 FEETflameproof type FLP-WP made of aluminium alloy LM6,with electronic ballast,bipin holders, connector block, etc. complete with all accessories prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable sizecomplete all as specified and directed . PRODUCT CAT NO SSPL/FF/1271 Shyam Switch Gear or other equilant ofSUDHIR / BALINGA / CROMPTON GREAVES as approved by the GE. 45 S&F flame proof weather rotary switch with cable terminal box in cat aluminum alloy ( LM-6) construction, epoxy powder coated, single pole 16 Amp ON/OFF type, 230 V AC, certified by CMRS for Group IIA & IIB complete including compression glands all as specified and directed. 46 M&L Point wiring for socket point using approved colour coding as per IS, withFlame retardant Low Smoke Halogen (FRLSH), smoke free, non toxic, non corrosive installation cable with UNILAY construction copper conductor 2.50 Sq. mm (nominal area), single core,insulated and unsheathed stranded cable 1100 Volts grade ISI-694 marked TEC and FIA approved in & including heavy duty, electric resistance welded (ERW) stove enameled surface Steel mounted conduit,heavy duty ISI marked as per IS:9557 (Part I) 1980 , includingFRLSH insulated unsheathed unitary construction copper conductor 2.5 Sq. mm nominal cross sectional area wire as earth continuity conductor up to common earth and connecting to earth dolly complete all as specified and directed. Note :-All conduit accessories such as bends elbows Tee etc shall be Flame proof certified by CMRS Dhanbad . 47 M&L forflame proof switchsocket & plug combinedpoint controlled by single pole one way 16 Amp ON-OFF rotary switch. Flame proof switch socket & plug combined in LM6 cable termination box in LM6, 16A, 250V, 2P+earth complete all as specified and directed. 48 M&L for point wiring for One light/fan/exhaust fan point controlled by one way 5 Amp switch complete with stranded copper conductor 1.5 Sqmm size (Nominal area) PVC insulated unsheathed cable FRLS in and includingPVC conduit ISI marked not less than 20mm dia with concealed sunk in pressed steel terminal boxes of reqd size of thickness 1.6 mm factory made and painted with stove enameled black paint with top cover 3mm thick plastic laminated sheet of required colour fixed with brass screws and cup washer including 1.5 sqmm stranded copper conductor PVC insulated cable of green colour as earth continuity connected to common earth dolly and all sunk/terminal boxes and each fitting/fixture, complete with all accessories all as specified and directed. 49 Decsription all as per srl item no. 44 above but for 3/5 pin socket outlet for 5 Amps on independent board with 1.5 sqmm PVC insulated, unsheathed single core multistranded copper conductor cable 1100 volts grade including 1.5 sqmm PVC insulated unsheathed multi-stranded copper conductor cable as earth continuity conductor complete all as specified & directed. 50 Decsription all as per srl item no. 44 above but for 3/5 pin socket outlet for 15 Amps on independent board with 2.5 sqmm PVC insulated, unsheathed single core multistranded copper conductor cable 1100 volts grade including 2.5 sqmm PVC insulated unsheathed multi-stranded copper conductor cable as earth continuity conductor complete all as specified & directed. 51 S&F surface/wall mountingLED batten, extruded aluminium housing provided for efficient heat dissipatin with poly carbonate diffuser & intergrated electronoc driver including 20 watt LED complete fitting as specified and directed. 52 Supply and fix in renewal of building Security light of LED light 35 W IP 66, New generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP Opening seperate driver compartment with IP66 protection and impact resistance of IK07 with 10KV Built-in Surge Protection Device including GI bracket made by 40mm GI pipe light grade, bent to shape of length up to 1.5 mtrs and with clamps , nuts, bolts etc grouting on wall and complete all as specified and directed. 53 Supply & fixsocket outlet 2 in 1, 3 pin 5/6Amps, flush universal type complete all as specified & directed. 54 S & F switch piano, flush type single pole, one way 5/6 Amps, 240 volts complete all as specified & directed. 55 S & Fswitch piano, flush type single pole, one way 15/ 16 Amps, 240 volts complete all as specified & directed. 56 S & Fsocket outlet 2 in 1, 3/5pin15 Amps, flush universal type complete all as specified & directed. 57 S&F flame proof weather proof lighting distribution pannel TPN 4 WAY Enclosure size: 420x420x250mm ,IncludingIncoming MCCB, 4P,63A-1 N0,16KA, OUTGOING MCB,1P ,16 to 32 A12nossuitable for housing MCB/Isolators and fixed the same on & including mild steel hold fasts of suitable size & shape after grouting the hold fasts in the wall with and including PCC (1:2:4) type B1 using 20mm graded stone with complete internal bus bar & wiring upto terminals aggregate complete all as specified & directed. 58 S&F flame proof weather proof lighting distribution pannel SPN 12 WAY Enclosure size: 390x390x190mm ,IncludingIncoming MCB, 2P,63A-1 N0,16KA, OUTGOING MCB,SP ,6 to 63 A - 10 Nos,suitable for housing MCB/Isolators and fixed the same on & including mild steel hold fasts of suitable size & shape after grouting the hold fasts in the wall with and including PCC (1:2:4) type B1 using 20mm graded stone with complete internal bus bar & wiring upto terminals aggregate complete all as specified & directed. 59 S&F flame proof weather proof lighting distribution pannel SPN 4 WAY ,IncludingIncoming MCB, 2P,16Ato32A -1 N0,16KA, OUTGOING MCB, SP ,6 to 32 A -2 Nos,suitable for housing MCB / Isolators and fixed the same on & including mild steel hold fasts of suitable size & shape after grouting the hold fasts in the wall with and including PCC (1:2:4) type B1 using 20mm graded stone with complete internal bus bar & wiring upto terminals aggregate complete all as specified & directed. 60 M&L for heavy duty exhaust fan flame proof body AC single phase 230 volts ,50 Hz of size 300mm sweep , with blades, frame and louvers fixing with cutting the wall of adequate size in round shape , making good the disturbed surface with cement mortor and grouting the louvers and nut bolts of exhaust fan complete all as spacified and directed. Make : Shyam Switch Gear cat partNo-SSPL/MT/140 or equivalent inSUDHIR / BALINGA / CROMPTON GREAVES /Bajaj/Havells as approved by the GE. 61 Supply and fix double wall corrogated as per IS 16025 PART-24 pipe of outer dia 40mm and inner dia 30 mm ( including all connected fitting and accessories)all as specified and directed. 62 M&L for Demolition of PCC/Black bitumin road of any description and in any position of depth upto 45cm and width 40 cm to lay the LT UG cablecomplete all as specified and directed. 63 M&LPCC(1:2:4) type B-2 (using 40mm graded stone aggregate) as in road, Hardstanding ,surface and similar work etc complete all as specified and directed. 64 Supply, laying, commessioning, testing of XLPE , armoured heavy duty electric under ground LT cable 1100 volts grade of size 10 Sqmm 4 core with aluminium conductor to IS 1554,ISI laid in tranchies, fixing on wall, under road crossing, etc complete all as specified and directed. 65 Supply, laying, commessioning, testing of XLPE , armoured heavy duty electric under ground LT cable 1100 volts grade of size 16 Sqmm 4 core with aluminium conductor to IS 1554,ISI laid in tranchies, fixing on wall, under road crossing, etc complete all as specified and directed. 66 S & F of three phase industrial plug and socket with MCB TPN 63 Amps capacity with 4 Nos of aluminium bus bar of capacity 200A with sheet steel enclosuremounted on wall or floor with all fixing arrangements with provision of cable connection for incoming and outgoing complete and all as specified and directed 67 Supply, laying, commessioning, testing of XLPE , armoured heavy duty electric under ground LT cable 1100 volts gradewith aluminium conductor conforming to IS:1554, laid in trenche, fixing on wall, under road crossing, etc complete all as specified and directed for the following size. 68 70 Sqmm 3 ½ core 69 50 Sqmm 3 ½ core 70 95 Sqmm 3 ½ core 71 S & F double wall corrogated as per IS 16025 PART-24 pipe of outer dia 63mm and inner dia 50 mm ( including all connected fitting and accessories)all as specified and directed. 72 S & F double wall corrogated as per IS 16025 PART-24 pipe of outer dia 75mm and inner dia 61 mm ( including all connected fitting and accessories)all as specified and directed. 73 S & F double wall corrogated as per IS 16025 PART-24 pipe of outer dia 110mm and inner dia 90 mm ( including all connected fitting and accessories)all as specified and directed. 74 M&L for brick work with sub class B bricks (using old size bricks), straight or curved on plan, exc 6M mean radius, built in CM 1:4 complete all as specified and directed . 75 M&L for 10mm thick rendering in CM 1:4 on fair faces of brick work or concrete surfaces, finished the surface even and smooth (without using extra cement) complete all as specified and directed. 76 M&L forplain cement concrete (1:2:4) type B-2(using 40mm graded stone aggregates)as in footings, foundation, mass concrete etc complete all as specified and directed. 77 Boring of holes under road, pavement hard standing,taxi track, runway by trenchless technology using ultra sound technique and necessary machine including HDPE pipe of 100/150mm dia suitable for 0.4 mpa working pressure complete all as specified and directed. 78 M&L for 100 mm dia galvanised water tubinglight gradewith all fittings for earthing lead protection of under ground /on wall complete all as specified and directed. 79 M&L forbore well earthing in repair by DTH (Pneumatic drill machine) machine upto depth of 50 mtr below ground level of 150mm dia to insert the MS casing pipe of 150mm dia up to 12mtr depth and suitable for inserting the earth electrode 50mm dia GI pipe medium grade duly drilled hole 12mm dia on pipe,15cm C/C on both side of pipe including lowering in bore well upto depth of 49.5 mtr and 0.5 mtr above ground level and the GI pipe will be braced with FI clamps at top of size 32x6mm including nut bolts. The bore well should be filled withcommercial salt charcoal dust, and magnesium phosphate of 30cm layer each upto the full length of pipe. the bore well casing pipe should have 12 mtr of length 150mm dia 5 mm thickness MS pipe for protection of bore well.welding of GI strip 50x6mm on earth electrode of length 0.5 mtr andinclude upto 7.5 mtr to the test pointand GI tubing light grade 50 mm upto 7.5 mtr from the bore well including test pointgun metal or phosphorus bronze size 75x75x25mm, drilled screwed including 3 Nos, 8mm dia, 25mm long hex head screw and PCC earth pit foundation surrounding the bore well 60x60x30cm and pit cover all as directed by EIC. 80 M & L for earthing with galvanised steel earth plate electrode 60cm x 60cm x 6.0mm thick burried directly in ground vertically at a depth not less than 2.25 metre below normal ground level with top edge of earth plate shall be at a depth not less than 1.5 metre below normal ground level, earth plate surrounded from all sides by 15 cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using galvanised iron strip of 32x6 mm as earthing lead (upto the body of the equipment) by means of bolts, nuts, check nuts and washers made of galvanised iron and thimbles and protected by medium 40 mm dia GI pipeconnected to main switch board or main control board or equipment and GI pipe medium grade 20mm bore for watering and including funnel, wire mesh, 40mm thick RCC pit cover reinforcedwith 8mm dia TMT bar at 75 mm c/c both ways and lifting arrangement by providing handles (02 Nos) of 12mm dia MS round bar and PCC chamber pit with PCC (1:3:6) type C-1 (using 20mm graded stone aggregate) including excavation and earth workreturning, filling in with excavated soil and disposal of surplus spoil to a distance not exceeding 50m and shown in electrical Plate No 3 of SSR 2009 (Part-I) complete all as specified and directed. 81 Supply, Install , testing and commissioning of LT panel of suitable size for 3 Phase 415 Volts indoor type made out 2.0 mm thick CRCA sheet of sides of the panel board,250 Amp aluminium bus bar insulated with PVC sleaves and coloured with (red, yellow,blue and black) CTR and internal wiring with suitable size of PVC insulated copper wire, use withangle iron 50 x 5 0 x 6 mm frame bottom of the panel board , grouted by using PCC foundation 1 : 2 : 4 type C1 with 20 mm graded stone aggregate , thimbling and cable entry boxes with cable gland. and theAluminium bus bar should be 1.5 time from themain incoming and comprising of the followings:- (a)MCCB 4 pole 400 amps 36 KA -01 NO (INCOMING)(b)MCCB 4 pole 250 amps 25 KA-01 NO(OUTGOING) © MCCB 4 pole 163 amps 25 KA -01 NO (OUTGOING)(d)Ampere meter (digital type)with selector switch - 01 No(e)Volt meter (digital type) 0-500 volts with selector switch - 01 No 82 M&L for point wiring for One light/fan/exhaust fan point controlled by one way 5 Amp switch complete with stranded copper conductor 1.5 Sqmm size (Nominal area) PVC insulated unsheathed cable FRLS in and includingPVC conduit ISI marked not less than 20mm dia with concealed sunk in pressed steel terminal boxes of reqd size of thickness 1.6 mm factory made and painted with stove enameled black paint with top cover 3mm thick plastic laminated sheet of required colour fixed with brass screws and cup washer including 1.5 sqmm stranded copper conductor PVC insulated cable of green colour as earth continuity connected to common earth dolly and all sunk/terminal boxes and each fitting/fixture, complete with all accessories all as specified and directed. 83 Decsription all as per srl item No. 75 above but for 3/5 pin socket outlet for 5 Amps on independent board with 1.5 sqmm PVC insulated, unsheathed single core multistranded copper conductor cable 1100 volts grade including 1.5 sqmm PVC insulated unsheathed multi-stranded copper conductor cable as earth continuity conductor complete all as specified & directed. 84 Decsription all as per srl item No. 75 above but for 3/5 pin socket outlet for 5 Amps on same board with 1.5 sqmm PVC insulated, unsheathed single core multistranded copper conductor cable 1100 volts grade including 1.5 sqmm PVC insulated unsheathed multi-stranded copper conductor cable as earth continuity conductor complete all as specified & directed. 85 Decsription all as per srl item No. 75 above but for 3/5 pin socket outlet for 15 Amps on independent board with 2.5 sqmm PVC insulated, unsheathed single core multistranded copper conductor cable 1100 volts grade including 2.5 sqmm PVC insulated unsheathed multi-stranded copper conductor cable as earth continuity conductor complete all as specified & directed. 86 S & F switch piano, flush type single pole, one way 5/6 Amps, 240 volts complete all as specified & directed. 87 S & F socket outlet, 2 in 1, 3 pin,5/6 Amps, flush universal typecomplete all as specified & directed. 88 S & F switch piano, flush type single pole, one way 15/16 Amps, 240 volts complete all as specified & directed. 89 S & F socket outlet, 2 in 1, 5 pin,5 and 15 Amps, flush universal typecomplete all as specified & directed. 90 S & F exhaust fan, AC, single phase, 230 / 240 volt of size 450mm sweep with louvers complete all as specified & directed. 91 S & Fceiling rose, surface bakelite, 32.5x25mm surface type,three terminals, AC 240 volts complete all as specified & directed. 92 M&L for sub main wiring with two runs of single core FRLS PVC insulated, unsheathed, mutistranded copper conductor cable of size 4.0 sqmm drawn in and including PVC rigid conduit not less than 20mm dia with its accessories, surface type, including one run of single core FR PVC insulated, unsheathed, mutistranded copper conductor cable of size 4.0 sqmm as earth continuity and connected of common earth dolly complete all as specified & directed.Note:- Two runs of 4.0 sqmm cable & one run of 4.0 sqmm cable alongwith PVC conduit including its accessories shall be measured and paid one unit length. 93 S&F surface/wall mountingLED batten, 22 watt LED lamp extruded aluminium housing provided for efficient heat dissipating with polycarbonatel diffuser & intergrated industrial grade heavy duty electronic driver including22 Watt LED complete all as specified and directed. 94 S&F factory made sheet metal enclosure MCB DB 240 volts, 4 ways with 200A rated bus bar, SPN, double door type IP43 suitable for housing MCB/Isolators and fixed the same on & including mild steel hold fasts of suitable size & shape after grouting the hold fasts in the wall with and including PCC (1:2:4) type B1 using 20mm graded stone aggregate complete all as specified & directed. 95 S&F MCB, SP, AC, 240 volts of 06 to 32 Amps capacity C series, 10 KA and making connections complete all as specified & directed. 96 S&F MCB SPN 40 to 63 Amp 240V, C series 10 KA, complete all as specified and directed. 97 S&F LED streetlight fitting 60 watt, 230 V, AC, outdoor type with high pressure die cat aluminium housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal managment in multiple optics, IP-66 protection complete all as specified and directed. 98 S&F 1.50 Mtr long house service bracket, made out of 40mm dia light grade GI pipe, bent to shape including MS hook & stay or guy and fixed to wall/ poles including all necessary nut/ bolts complete all as specified and directed. 99 Supply and fixing on pole / wall, PVC insulated, heavy duty electriccable, unarmoured of size 10 Sqmm 2 core with stranded aluminium conductor, flat / round with and including fixing arrangement complete all as specified and directed.

Key Value

Document Fees
INR 500 /-
Tender Value
INR 37.25 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail