| 1 | Demolishing R.B. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in- charge. |
| 2 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. |
| 3 | Dismantling and stacking within 50 metres lead, fencing posts or struts including all earth work and dismantling of concrete etc. In base of: |
| 4 | T\" or \"L\" iron or pipe |
| 5 | Dismantling steel work manually/ by mechanical means in built up sections without dismembering and stacking within 50 metres lead as per direction of Engineer-in-charge. |
| 6 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. |
| 7 | Hacking of CC flooring including cleaning for surface etc. Complete as per direction of the Engineer-in-Charge. |
| 8 | Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of: |
| 9 | G.S. Sheet |
| 10 | Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared. |
| 11 | Earth work in excavationby mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 Sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed,with in a lead of 50mtrs. |
| 12 | All kinds of soil |
| 13 | Supplying and filling in plinth with sand under floors, including watering ,ramming, consolidating and dressing complete. |
| 14 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level |
| 15 | 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 16 | 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 17 | 1:4:8(1Cement:4coarsesand:8gradedstone aggregate 40 mm nominal size). |
| 18 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : |
| 19 | 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size de rived from natural sources) |
| 20 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : |
| 21 | 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natu ral sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources |
| 22 | Centeringandshutteringincludingstrutting,proppingetc.and removal of form for |
| 23 | Foundations,footings,basesofcolumns,etc.for mass concrete. |
| 24 | Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc |
| 25 | Columns, Pillars, Piers, Abutments, Posts and Struts |
| 26 | Shelves (Cast in situ) |
| 27 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. |
| 28 | Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 29 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. |
| 30 | Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 31 | Providing and laying Hollow cement concrete block walling 200mm thick consisting of hollow block of size 400x200x200mm of mix 1:3:6 (1cement:3 Pulverised sand:6 graded stone aggregates of 10mm nominal size) laid in cement martar 1:6(1cement :6 sand). |
| 32 | Providing and laying Hollow cenment concrete block walling 100mm thick consisting of hollow block of size 400x100x200mm of mix 1:3:6 (1cement:3 Pulverised sand:6 graded stone aggregates of 10mm nominal size) laid in cement martar 1:6(1cement :6 sand). |
| 33 | 12 mm cement plaster of mix : |
| 34 | 1:4 (1 cement: 4 fine sand) |
| 35 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White,Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sq.m including pointing the joints with white cement and matching pigments etc., complete. |
| 36 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades,laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand),jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. |
| 37 | Size of Tile 600x600 mm |
| 38 | Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 39 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. |
| 40 | Electric resistance or induction butt welded tubes |
| 41 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. |
| 42 | In gratings, frames, guard bar, ladder, railings, brackets, gates and similar work |
| 43 | Finishing walls with Acrylic Smooth exterior paint of required shade : |
| 44 | New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |
| 45 | Providing and fixing mild steel round holding down bolts with nuts and washer plates complete. |
| 46 | Providing and fixing bolts including nuts and washers complete. |
| 47 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin- charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 48 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : |
| 49 | Two or more coats on new work |
| 50 | Finishing walls with Acrylic Smooth exterior paint of required shade : |
| 51 | Old work (Two or more coat applied @ 1.67 ltr/ 10 sqm) on existing cement paint surface |
| 52 | ELECTRICAL WORKS |
| 53 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC Conduit as required or as directed by Engineer-In-Charge. |
| 54 | 2x1.5sq.mm +1x1.5sq.mm earth wire |
| 55 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). |
| 56 | 6 way, Double Door |
| 57 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 58 | Single pole |
| 59 | Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 60 | 63 Amps, 2 Pole Isolator |
| 61 | Supplying of laying of 01 No. double walled corrugated high density polyethylene pipe having corrugation at the outer wall and plain surface inner walls, conforming to ISI4930 part-I&II, complete with necessary HDPE fitting for protction of 1.1 KV underground cable directly in ground at a depth of 50 cm i/c excavation & refillinig the trench etc as required. |
| 62 | 63mm dia (OD =63mm & ID = 51mm nominal) |
| 63 | Supplying and Fixing of JETA NEO 100W flood light made of exclusive innovative die-cast aluminium IP65flood light with high power LEDs as light source suitable for highlighting architectural facade and general purpose lighting similar to Havells Ordering Code LHEPCZU7PA6J100 Lamp type 100W 6000K for mounting on 100mm channel including connectiom etc as required. Make: Outdoor LED Luminaires floodlight/Havells/Bajaj/Crompton or equivalent to ISI Standard. |
| 64 | Supplying and fixing of Hot pressed moulded SMC Box 280x170x100mm to house, 6 to 32 Amps MCB, 63 A 230V 4 way connector and clamping arrangement for SMC box etc. as required. (a) SMC box (280mm x 170mm x 100mm - 01 No.), (b) MCB 6Amps - 01 No. ( c ) 63 A, 230V, 4 way connector - 01 No. |
| 65 | Supplying of 3 Core 4.0 Sq.mm Armoured Copper Cable XLPE insulated core laid up, PVC tape inner sheathed for multicored cables armour galvanized wire for cable extruded PVC type ST2 sheathed 650 /1100V grade as pe IS 7098 (PART-I) 1988 as required. (Make: Havells/Polycab/Standard or equivalent to ISI Standard). |
| 66 | 3 Core X 4.0 Sq.mm XLPE armoured copper cable |
| 67 | Supplying of 3 Core 6.0 Sq.mm Armoured Copper Cable XLPE insulated core laid up, PVC tape inner sheathed for multicored cables armour galvanized wire for cable extruded PVC type ST2 sheathed 650 /1100V grade as pe IS 7098 (PART-I) 1988 as required. (Make: Havells/Polycab/Standard or equivalent to ISI Standard). |
| 68 | 3 Core X 6.0 Sq.mm XLPE armoured copper cable |
| 69 | Supplying of 3.5 Core X 35 Sq.mm Armoured Copper Cable XLPE insulated core laid up, PVC tape inner sheathed for multicored cables armour galvanized wire for under ground cable extruded PVC type ST2 sheathed 650 /1100V grade as pe IS 7098 (PART-I) 1988 as required. (Make: Havells/Polycab/Standard or equivalent to ISI Standard). |
| 70 | 3.5 Core X 35 Sq.mm XLPE Armoured Copper Cable |
| 71 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of size exceeding 25 sq. mm but not exceeding 120 sq. mm direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. |
| 72 | Upto 35sq.mm |
| 73 | Supplying of 100mm x 100mm x 10mm GI angle for cross arms size (1.0M) fixing in GI pole in which the LED lights are mounted complete with fixing clamps, bolts, nuts and washer drilling holes for insulator pins, bolts and nuts etc and painting with primer and finish paint as required. |
| 74 | Supplying and laying of 20mm dia FRLS ISI marked, PVC Conduit complete as per direction of Engineer In-charge. |
| 75 | Supplying, installation, testing and commissioning of Decorative Post Top Lantern fittings similar to K-Lite model 5926 single 20W LED or equivalent to ISI standard including cost of Post Top Lantern fitting, cost of all labour charges, transportation charges, minor tools etc complete. Make: Bajia/Havells/Crompton/Phillips/Panasonic or equivalent to ISI STandard. |
| 76 | Supplying, installation, testing and commissioning of Decorative gate light made up of high grade unbreakable poly carbonate material suitable for Retrofit lamp type- upto 30W LED mounting pole dia - 40/60mm (max) OD Ordering Code- LHFXBON1TN5Q030 (Make: Bajaj/ Usha/ Orient /Crompton or equivalent to ISI standard). |