| 1 | Part A (Civil Portion) |
| 2 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. |
| 3 | All kinds of soil. |
| 4 | Surface dressing of the ground including removing vegetation and in- equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. |
| 5 | All kinds of soil |
| 6 | Providingandlayinginpositioncementconcreteof specified grade excluding the cost of centering and shuttering - All work up to plinth level : |
| 7 | 1:2:4 (1cement : 2 coarse sand (zone-Ill) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 8 | 1:4:8 (1Cement : 4 coarse sand (zone-Ill) derived from natural sources: 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 9 | Centering and shuttering including strutting, propping etc. and removal of form work for: |
| 10 | Foundations, footings, bases for columns |
| 11 | Centering and shuttering including strutting, propping etc. and removal of form for |
| 12 | Foundations,footings,basesof columns,etc.formass concrete |
| 13 | Suspended floors,roofs,landings,balconies and access platform |
| 14 | Lintels,beams,plinthbeams,girders,bressumersand cantilevers |
| 15 | Columns, Pillars, Piers, Abutments, Posts and Struts |
| 16 | Steelreinforcement forR.C.C.workincludingstraightening,cutting, bending, placing in position and binding all complete upto plinth level. |
| 17 | Thermo-Mechanically Treatedbars of gradeFe-500D or more. |
| 18 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforcedcement concrete work;usingcoarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /PortlandSlag cement,admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete,toimprovedurabilityandworkabilitywithoutimpairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.:Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. |
| 19 | All works upto plinth levelConcrete of M30 grade with minimum cement content of 350 kg /cum |
| 20 | All works above plinth level upto floor V levelConcrete of M30 grade with minimum cement content of 350 kg /cum |
| 21 | Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 22 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. |
| 23 | Electric resistance or induction butt welded tubes |
| 24 | Providing and fixing mild steel round holding down bolts with nuts and washer plates complete. |
| 25 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. |
| 26 | G.I. pipes |
| 27 | Providing and fixing precoated galvanised steel sheet roofing accessories of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05 mm) with Zinc coating 120 gram per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : |
| 28 | Ridges plain (500- 600mm) |
| 29 | 12 mm cement plaster of mix: |
| 30 | 1:4(1 cement: 4 fine sand) |
| 31 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour: |
| 32 | New work(twoormorecoats)over andincludingwater thinnable priming coat with cement primer having VOC content less than 50 gram/litre |
| 33 | Finishing walls with Acrylic Smooth exterior paint of required shade: |
| 34 | New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) |
| 35 | Painting with black anti-corrosive bitumastic paint of approved brand and manufacture to give an even shade: |
| 36 | Two or more coats on new work |
| 37 | Providingandlaying 60mmthickfaciorymadecementconcrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge. |
| 38 | Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in- charge. |
| 39 | Made of G.I. wire of dia. 4 mm, PVC coated to achieve outer dia not less than 5 mm in required colour and shade |
| 40 | Providing and fixing pre-painted galvalume (PPGL) steel profile sheets AZ-150 of brand Tata Bluescope steel, Everesrt Industries Ltd., JSW Steel Ltd., Jindal India Ltd. or equalavent(size,shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with aluminium zinc coating 150 grams per sqm as perIS : 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping aluminium screws (Xylan) of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 41 | Providing and laying hollow cement concrete block walling upto floor five level 200mm thick using consisting of hollow block of size 400 x 200 x 200 mm of mix 1:3:6 (1 cement::3 coarse sand : 6 graded stone aggregates 10mm nominal size) laid in cement mortar 1:6 (1 cement : 6 coarse sand). |
| 42 | Part B (Electrical & Mechanical Protion) |
| 43 | Supply, Erection/ Construction, Installation, Testing, Commissioning and satisfactory trial runs of advance fully automatic (having Micro processer-based control unit with IOT/ intranet/internet web-access, remote monitoring capabilities 5KLD capacity Faecal Sludge Treatment Plant (FSTP) of any Suitable Open Technology being adopted anywhere in India for Primary, Secondary & Tertiary/ any other Treatment of Faecal effluent meeting the standards prescribed by the MoEF&CC, GoI./ CPCB/ANPCC, as amend to date with treatment/ reuse/ safe disposal of sludge. The work including all Civil, Plumbing, Mechanical, Electrical & Instrumentation works along with spares wherever required as approved by Engineer-In-Charge. Including 03years of Operation & Maintenance of FSTP including deputation of technical manpower for testing, operation & monitoring/ supervision of Plant. |
| 44 | Supplying, installing and commissioning of Silent type \" Diesel generating set of 10 KVA with water cooled Diesel Engine, Electric start with suitable capacity 12 V battery, fitted complete with all the required accesories along with AC Alternator 3 Phase, 415 Volts, 50 Hz, 0.8 pfself Excited, Self RegulatedDesigned with Acoustic Enclosure(sound proof) as per CPCB-IV+, emission norms approved DG Set similar to KIRLOSKAR GREEN Make, Model:3R550NA 4GI or Equivalent. |
| 45 | Supply, installation, testing and commissioning of standard fully automatic mains failure panel for 10 KVA capacity genset of suitable size with following technical specification. (a)Electricity board supply of loading/Unloading in off/manual/auto mode.(b)Selectable Auto/Manual Start/Stop of the generator. (c)Selectable Auto/Manual loading/unloading of the generator. (d)Interlocking loops with solid state logic circuit to avoid shorting of EB supply side and generator supply side. (e) Short circuit protection system for both EB side and generator side. (f) Over load protection system for generator (g)Single phase reversal prevention system. (h) Phase sequence sensing system. (i) Time sensing system for all operation (j)Monitoring digital system for voltage, amps, and frequency.(k)Short circuit protection for DC circuit. (l)Fully automatic battery charger with all protections. (m) Manual Change over for EB by pass. |
| 46 | Supplying of one number XLPE insulated PVC outer sheathed with galvanised round steel wire or steel strip armoured aluminium conductor power cable of 1.1 KV grade of size 25 sq.mm x 3.5 core conforming to IS 7098 (Part-I) 1988 amended upto date. |
| 47 | Supplying and layingof DWC HDPE pipe of size 50/38, ISI marked along with all accessories like socket, bend, couplers etc . Conforming to IS 16205 (Part 24): 2018/IS, complete with fitting and cutting, jointing etc. on open surface asrequired. |
| 48 | 50 mm dia (OD-50 mm & ID-38 mm nominal) |
| 49 | Laying of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1kV grade of following size in the existing HDPE/DWC pipe as required. |
| 50 | Upto 35 sq. mm |
| 51 | Laying of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1kV grade of following size in the existingopen surface/duct as required. |
| 52 | Upto 35 sq. mm |
| 53 | Providing Earthing with safe earthing electrode of galvanization 80 to 100 microns length 2000 mm, 48mm diaand inner space to be filled with crystaline conuctive mixture including filling - up with electrodite (Back fill Compound) 50kg for safe earth electrode and provoding masonary enclosure with cover plate having locking attagement etc. as required. (Similar to ASHLOK make SEE brand safe earthing or equivalent) |
| 54 | Providing· and fixing 25 mm X 5 mm· G.l. strip in 40 mm dia G.l. pipe from earth electrode including connection with G.l. nut, bolt, spring, washer excavation and refilling etc. as required. |
| 55 | Supplying and layingof DWC pipe of size 40/32, ISI marked along with all accessories like socket, bend, couplers etc . Conforming to IS 16205 (Part 24): 2018/IS, complete with fitting and cutting, jointing etc. direct in ground (50 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. |
| 56 | 40 mm dia (OD-50 mm & ID-32 mm nominal) |
| 57 | Supplying and layingof DWC HDPE pipe of size 40/32, ISI marked along with all accessories like socket, bend, couplers etc . Conforming to IS 16205 (Part 24): 2018/IS, complete with fitting and cutting, jointing etc. on open surface asrequired. |
| 58 | 40 mm dia (OD-40 mm & ID-32 mm nominal) |
| 59 | Supplying of one number XLPE insulated PVC outer sheathed with galvanised round steel wire or steel strip armoured aluminium conductor power cable of 1.1 KV grade of size 6 sq.mm x 3 core conforming to IS 7098 (Part-I) 1988 amended upto date. |
| 60 | Fabricating and Supplying of metallic street light pole made out of an overall length of 6.5 meters long having a bottom section length of 5.00 meters with 65 mm dia \"B\" class ISI marked G.I Pipe.Top section having a length of 1.5 meters with40 mm dia \"B\" class ISI marked G.I Pipe suitably bended for installing 01 No Street Light having earth stud and necessary GI reducer/coupling fixed at the top & middle. Welding 300 mm x 300mm x 6mm thick MS base plateto the bottom including welding100 mm X 25mm X 5mm M.S Flat for fixing PVC junction Box with 6A MCB on the Pole, i/c one coat of metalic primer and 02 coat of silver paint.Providing necessary wiring between junction box and st light fitting by 2x 1.5 Sq mm FR-LSH PVC Insulated copper conductor cable etc. as required. |
| 61 | Erection of pole of following length in brick ballast and ramming the foundation, finishing with 150mm thick cement concrete (1:3:6) layer on top with including excavation and refilling etc. as required. |
| 62 | Above 4.5 meter and upto 6.5 meter |
| 63 | Supplying and FixingLEDstreet light of 30W with IP66protection and impact resistance ofIK07 equivalent to LUKER Sleek series street light product code LSTE-30 or its equivalent. |
| 64 | Supplying and Fixing2 Way Metal Enclosure along with double pole 40A Isolator with necessary inter connections as required Make:indoasian Cat No : 810560I & 810130 orits equivalent. |
| 65 | Wiring for light point / Fan point / Exhaust Fan point / Call Bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable insurface / recessed PVC conduit, with modular switch, modular plate, suitable size G.I. box andearthing the point with 1.5 sqmm.FRLS PVC insulated copper conducotor single core cable etc. as required . |
| 66 | Group-C |
| 67 | Wiring for Light/ power plug wiring with 2 x 4 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed PVC conduit alongwith 1 No. 4 sq.mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 68 | Wiring for Circuit/ sub mainWiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed PVC conduit as required. |
| 69 | 2x1.5 sq.mm + 1x1.5 sq.mm. earth wire |
| 70 | Supplying and fixing two module stepped type electronic fan regulator on the exisiting module plate swicth box including conenctions but excluding modular plate etc. as required. |
| 71 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 Amodular switch, connections etc. as required. |
| 72 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular switch, connections etc. as required. |
| 73 | Supplying, testing amd commissioning of wall bracket/ ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required. |
| 74 | Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. |
| 75 | Installation, testing and commissining of ceiling fan, including wiring the down rods of standard length (upto 30cm) with 1.5 sq.mm FRLS PVC insulated copper conductor, single core cable etc. as required |
| 76 | Supplying and fixing of PVC Button/Angle Holder including connections etc as required. |
| 77 | Supplying and fixing following way, horizontal type Single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 78 | 6 -way , Double door. |
| 79 | Supplying and fixing 5 A to 32 A rating,240/415 V, 10 kA \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 80 | Single Pole |
| 81 | Supplying and fixing following rating , double pole , 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 82 | 40 A |
| 83 | Supplying of smart LED Bulb similar to Havells LED ADORE 9W B22 CDL 2 STAR Lamp or Crompton/ Bajaj/Havells/Philips. |
| 84 | Supplying of 12W LED, 6000K ED Bulk head fittings simialr to Luker, Cat No.LBKOVSL 12or its equivalent |
| 85 | Supplying of 20W LED Retrofit Tube Light Batten Make: Crompton, Model: DIJB12TL-20 or its equivalent to IS specification. |
| 86 | Supplying of 20 W, 6500K 4 feet Retrofit Tube Light similar to Philips, Model No. 20W856 T8 IND I 2100lm or its equivalent to IS specification |
| 87 | Supply of 5 star Energy savingceiling fans BLDC (26W to 32W), 1200mm sweep (White) Make: USHA Model: Techno Air (Without remote) or equivalent. |