Tender For Repair / Maintenance Of Summer Appliances, Hot Water Appliances (Geyser) And Other Misc E/M Works Under Ge (Af) Srinagar, srinagar-Jammu And Kashmir

Military Engineer Services has published Tender For Repair / Maintenance Of Summer Appliances, Hot Water Appliances (Geyser) And Other Misc E/M Works Under Ge (Af) Srinagar. Submission Date for this Tender is 24-09-2025. AMC of Air Condition Tenders in srinagar Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

51019014
Tender For Repair / Maintenance Of Summer Appliances, Hot Water Appliances (Geyser) And Other Misc E/M Works Under Ge (Af) Srinagar
Tender
Indian
Jammu And Kashmir
Srinagar
24-09-2025

Tender Details

Tender For Repair / Maintenance Of Summer Appliances, Hot Water Appliances (Geyser) And Other Misc E/M Works Under Ge (Af) Srinagar; 1 Taking down folloiwing fan of any type and size from site and removing to MES store for servicing like cleaning, lubricating, greasing and replacement of split pin, bearing, bush, capacitor, connection wire and refixing the fan at same location after spray painting to complete fan including blade by applying one coat of synthetic enamel paint and testing, complete all as specified and directed.Note :- (a) Contractor will provide one electrician and one helper for removing the faulty fan and refixing the serviced ceiling fan.(b)Contractor team will report to AGE E/M Sub Div daily except sunday and holiday at 0900 Hrs to collect ceiling fan complaints. (c)Contractor will give one year guarantee for repairable fan (except burnt out fans)(d)Rate quoted by the contractor shall be deemed to be inclusive of spare parts as required. 2 Ceiling fans of any size any sweep 3 Exhaust fans of any size (metal body) 4 Exhaust fans of any size (PVC body) 5 Wall mounting / Air circulator fan of any size and type 6 M&L for replacement of burnt out coil of copper and aluminium winded for following fans and rewinding complete with super enamelled copper wire of same guage and weight including replacement of bearing, bush, capacitor, insulation paper and varnishing including spray painting to complete fan including blade by applying one coat of synthetic enamel paint and testing complete including taking down, removal to workshop and refixing, complete all as specified and directed.Note :- 1. Rewinding work shall be carried out at AGE E/M store yard or any place decided by Engineer-in-Charge. 2.Contractor is responsible to give one year guarantee of (rewinding fans) 7 Ceiling fan 1200 / 1400mm sweep working on 230 volts AC supply 8 Exhaust fan upto 600mm sweep working on 230 volts AC supply (metal body) 9 Exhaust fan upto 400mm sweep working on 230 volts AC supply (metal body) 10 Exhaust fans upto 300mm sweep working on 230 volts AC supply (PVC body) 11 Wall mounting / Air circulator fan of any sweep working on 230 volts AC supply 12 S&F in repairs fan hanging hook any type or size suitable to hang on wooden block, MS bar etc. with rubber seel, nuts, bolts, split pin etc suitable for ceiling fan, complete all as specified and directed. 13 S&F in replacement down rod made out of 15mm bore dia GI pipe, medium grade, 40cm long with fan clamps including drilling, cutting threading and white painting etc for ceiling fans 1200 / 1400mm sweep, complete all as specified and directed. 14 S&F in repairs canopy for ceiling fans upper and bottom (set of two), complete all as specified and directed. 15 S&F in replacement 12mm thick water proof plywood ISI Marked, 12mm thick, by cutting as required size including necessary provisions for mounting in walls, openings and securing using fasteners 10cms long and 8mm dia for mounting of exhaust fans in various locations and sizes, complete all as specified and directed. 16 S&F ventilation / exhaust fan made out of plastic, 150mm sweep, complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, copper winding, including taking down old unserviceable PVC ventilation / exhaust fan after disconnecting the wire from ceiling rose and deposited to store yard of AGE E/M, complete all as specified and directed. 17 S&F ventilation / exhaust fan made out of plastic, 200mm sweep, complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, copper winding, including taking down old unserviceable PVC ventilation / exhaust fan after disconnecting the wire from ceiling rose and deposited to store yard of AGE E/M, complete all as specified and directed. 18 S&F ventilation / exhaust fan made out of plastic, 250mm sweep, complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, copper winding, including taking down old unserviceable PVC ventilation / exhaust fan after disconnecting the wire from ceiling rose and deposited to store yard of AGE E/M, complete all as specified and directed. 19 S&F of Exhaust fan, made of sturdy Engineering steel body, complete with louvers shutter, 450mm sweep, voltage 230V, 50 Hz, RPM 1200, copper winding, including taking down old unserviceable steel body ventilation / exhaust fan after disconnecting the wire from ceiling rose and deposited to store yard of AGE E/M, complete all as specified and directed . 20 S&F of Exhaust fan, made of sturdy Engineering steel body, complete with louvers shutter, 300mm sweep, voltage 230V, 50 Hz, RPM 1200, copper winding, including taking down old unserviceable steel body ventilation / exhaust fan after disconnecting the wire from ceiling rose and deposited to store yard of AGE E/M, complete all as specified and directed . 21 S&F ceiling fans complete with blades, down rods, electronic regulator and accessories 230V, 1200 mm sweep, minimum air delievery 210 CFM with service value 6.00, BEE 5 star rated including taking down old unserviceable ceiling fans after disconnecting the wire from ceiling rose and deposited to store yard of AGE E/M, complete all as specified and directed. 22 S&F wall mounted fans complete with blades and accessories, 230 V, 400mm sweep, Min air delivery 210 CFM, including taking down old unserviceable wall mounted fans after disconnecting the wire from ceiling rose and deposited to store yard of AGE E/M, complete all as specified and directed. 23 S&F pedestal fans complete with blades and accessories, 230 V, 400mm sweep, Min air delivery 210 CFM, including taking down old unserviceable pedestal fans after disconnecting the wire and deposited to store yard of AGE E/M, complete all as specified and directed. 24 S&F in replacement stepped type, electronic fan regulator, flush type on the existing phenolic laminated sheet etc. suitable for 1200mm sweep ceiling fan, all as specified and directed. 25 S&F in replacement louver shutter of exhaust fan upto 400mm size round or square as per site condition including fixing arrangement with fixing material, complete all as specifed and directed. 26 S&F in replacement terminal connector 3 way, complete all as specified and directed. 27 S&F in replacement capacitor 2.5 mfd 230 volts, complete all as specified and directed. 28 S&F in replacement capacitor 3.5/ 4 mfd 230 volts, complete all as specified and directed. 29 S&F MS screw for fixing of ceiling fan blade of any size and type, complete all as specified and directed. 30 S&F in replacement of fan blade suitable for 1200mm sweep ceiling fan, complete all as specified and directed. Note : Blade shall be suitable for Bajaj/ Crompton/ Usha/ Havells / Polar make fans. 31 S&F in replacement of fan blade suitable for upto 450mm sweep steel exhaust fan, complete all as specified and directed. Note : Blade shall be suitable for Bajaj/ Crompton/ Usha/ Havells/ Polar make fans. 32 S&F in replacement ofPVC fan blade suitable for wall mounted fan upto 600mm sweep, complete all as specified and directed. Note : Blade shall be suitable for Bajaj/ Crompton/ Usha/ Havells/ Polar make fans. 33 S&F in replacement ofwall mounted fan blade guard of size upto 600mm sweep,complete all as specified and directed. Note : Blade shall be suitable for Bajaj/ Crompton/ Usha/ Havells/ Polar make fans. 34 S&F in replacement of 6 Amp Modular switch, 01 Module, complete all as specified and directed. 35 S&F in replacement of 6 Amp piano switch, complete all as specified and directed. 36 S&F in replacement PVC copper cable flexible 3 core round heavy duty of size 40/0.0076 suitable for fan connection of any capacity, complete all as specified and directed. 37 S&F ball bearing of ceiling fan of size 1200 /1400mm sweep exactly similar as existing in fan, complete all as specified and directed. 38 S&F ball bearing of exhaust fan of size 300 /400 / 450mm sweep exactly similar as existing in fan, complete all as specified and directed. 39 S&F gun metal bush of ceiling fan of size 1200 /1400mm sweep exactly similar as existing in fan, complete all as specified and directed. 40 S&F gun metal bush exhaust fan of size 300 /400 / 450mm sweep exactly similar as existing in fan, complete all as specified and directed. 41 Disconnecting and taking down unserviceable geyser of 25 / 50 litre capacity of any make from the wall and opening carefully including descaling the inner surface by scrapping, carrying out soldering / brazing / gas welding to prevent the leakage, filling of glass wool and replacement of any other defective spares,including replacement of required number of stainless steel screws, nuts & bolts, assembling the the same after repair work and refixing the same in its orginal place, connecting to water mains and electric supply, testing after repairs, complete all as specified and directed.Note : Spare parts and glass wool shall be measured and paid separtaly under respective items of BOQ. 42 Supply only glass wool of good quality as approved for 25 litre capacity of geyser, complete all as specified and directed. 43 All as per Ser item No. 33.00 here-in-before but 50 litre capacity. 44 S&F in replacement of unserviceable Stainless steel inner tank of 25 litre capacity geysers of existing make & model including testing after assembling & fixed at site, complete all as specified and directed. 45 All as per Ser item No. 35.00 here-in-before but 50 litre capacity. 46 S&F in repairs heating element, 2000 Watt, screw or stud type ISI marked 1500 watt 230 volts AC single phase including necessary washer, screw, nuts bolts etc., complete all as specified and directed. 47 S&F in repairs heating element, 3000 Watt, screw or stud type ISI marked 1500 watt 415 volts AC three phase including necessary washer, screw, nuts bolts etc., complete all as specified and directed. 48 S&F in repairs heating element, 4000 Watt, screw or stud type ISI marked 1500 watt 415 volts AC three phase including necessary washer, screw, nuts bolts etc., complete all as specified and directed. 49 S&F in replacement thermostat switch ISI marked 230 Volts, 50 Hz, AC of range 0-100, degree centigrade, adjustable between 70 to 100 degree centigrade with necessary washer, screws nut etc., complete all as specified and directed. 50 S&F in replacement thermostat switch ISI marked 415 Volts (three phase) AC of range 0-100, degree centigrade, adjustable between 70 to 100 degree centigrade with necessary washer, screws nut etc., complete all as specified and directed. 51 S&F in repairs 06/08 hole assembly for water heater of capacity 25 Litre ISI Marked, complete all as specified and directed. 52 S&F in repairs 06/08 hole assembly for water heater of capacity 50 Litre ISI Marked, complete all as specified and directed. 53 S&F in replacement indicator lamp assy 230 volts square or round suitable for any type or make of Geyser including connecting, complete and all as specified and directed. 54 S&F in replacement 23 to 30cm long, 10mm bore C.P Connection with brass union, complete and all as specified and directed. 55 S&F in replacement 15mm bore PVC connection pipe, 45cm long, with brass union both ends fixed to GI pipe, complete and all as specified and directed. 56 S&F in replacement of bottom / top plates made out of 1mm thick MS sheet made to shape of required size, factory made, complete fitted with machining screws duly painted with synthetic enamel white paint, complete all as specified and directed. 57 S&F in replacement sheet metal enclosure with single pole and neutral with two pin and earth plug socket including 20Amp, 240 Volt, including 20 Amp MCB SP (C-series), complete all as specified and directed. 58 S&F in repairs 40 Amp metal clad industrial plug and socket 3 pole+ earth 415 Volts, complete all as specified and directed. 59 S&F in repairs MCB single pole 240 Volts ISI marked of capacity 16 Amps, C series, complete all as specified and directed. 60 S&F in repairs MCB Triple pole and neutral, 240 Volts, ISI marked of capacity 40 to 63 Amps, C series, complete all as specified and directed. 61 S&F in repairs 16 Amp switch socket combination, 5 in 1, flush type, ISI marked 240 Volts, complete all as specified and directed. 62 S&F in repairs 15/16 Amp three pin plug top ISI marked suitable for 240 Volts 50Hz AC, complete all as specified and directed. 63 S&F in repairs 16 Amp socket outlet, 2 in 1, 5 pin, flush type, ISI marked suitable for 240 Volts 50Hz AC, complete all as specified and directed. 64 S&F in repairs 16 Amp modular socket outlet, 2 in 1, 5 pin, ISI marked suitable for 240 Volts 50Hz AC, complete all as specified and directed. 65 S&F in repairs 16 Amp piano switch one way, flush type, single pole, ISI marked or 240 Volts 50Hz AC, complete all as specified and directed. 66 S&F in repairS 16 Amp modular switch one way, flush type, single pole, ISI marked or 240 Volts 50Hz AC, complete all as specified and directed. 67 S&F in repairs PVC gang box with 2 in 1, 5 pin, 16 Amps switch socket combination, ISI marked or 240 Volts 50Hz AC, complete all as specified and directed. 68 S&F in replacement 1100 Volts grade heavy duty cable PVC insulated stranded aluminium conductor served with inner sheathing of PVC tape and used for service connections suspended by insulating hangers not more than 1m apart of size 10 Sqmm 2 core, complete all as specified and directed. 69 S&F in repairs of Rubber O ring /gaskit having suitable holes to suit the hole of base plate of geyser of25 litre capacity, complete all as specified and directed. 70 S&F in repairs of Rubber O ring /gaskit having suitable holes to suit the hole of base plate of geyser of50 litre capacity, complete all as specified and directed. 71 Preparation of surface of geyser of 25 litre capacity of any make by scrapping to existing paint, filling cavities with filler (Putty) after cleaning of dust etc and applyingsynthetic enamel paint over a coat of red oxide primer with spray gun and writing the MES No with black paint, complete all as specified and directed. 72 Preparation of surface of geyser of 50 litre capacity of any make by scrapping to existing paint, filling cavities with filler (Putty) after cleaning of dust etc and applyingsynthetic enamel paint over a coat of red oxide primer with spray gun and writing the MES No with black paint, complete all as specified and directed. 73 S&F heavy duty pin type fastner 4 long (GI nuts and volts and washer of suitable sizes) suitable for any capacity of geyser as per site, complete all as specified and directed. 74 S&F 50 Litre capacity storage type water heater (Geyser), BEE 5 Star rated, vertical wall mounting type made out of CRCA outer body stainless steel storage tank, titanium enamelled heating element thermostat, thermal cutout, glass wool including 15 mm, 450 mm long (cold water pipe ), 15 mm, 450 mm long armourd pipe (hot water pipe) etc complete including making necessary electrical and water connections with 2.5 sqmm 3 core copper multistandred cable with top indicator plug top 15 amp from geyser connection to socket including hold fast for fixing of new geyser and writing the MES No. including taking down old unserviceable water heater (Geyser) and deposited to store yard of AGE E/M, complete as specified and directed. 75 S&F 25 Litre capacity storage type water heater (Geyser), BEE 5 Star rated, vertical wall mounting type made out of CRCA outer body stainless steel storage tank, titanium enamelled heating element thermostat, thermal cutout, glass wool including 15 mm, 450 mm long (cold water pipe ), 15 mm, 450 mm long armourd pipe (hot water pipe) etc complete including making necessary electrical and water connections with 2.5 sqmm 3 core copper multistandred cable with top indicator plug top 15 amp from geyser connection to socket including hold fast for fixing of new geyser and writing the MES No. including taking down old unserviceable water heater (Geyser) and deposited to store yard of AGE E/M, complete as specified and directed. 76 S&F in replacement flexible PVC insulatedcopper conductor cable 3 core 2.5 Sqmm of size 40/0.0076for AC of any capacity, complete all as specified and directed. 77 S&F in repairs of outer body, ISI marked, capacity 25 Litre, complete as specified and directed. 78 S&F in repairs of outer body, ISI marked, capacity 50 Litre, complete as specified and directed. 79 M&L for Point wiringfor one switch socket outlet 15 Amps on independent board for (geysers connection) complete with 2.5 Sqmm single core, PVC insulated unsheathed, FRLSH cable, 1100 volts grade, multistranded copper conductor, drawn through and including rigid non metallic PVC conduit and conduit accessories fixed on surface of wall/ceilings or concealed etc., including provision of PVC insulated 2.5 Sqmm FRLSH cable with copper conductor for earth continuity and connected to common earth dolly and modular type metal boxes concealed in wall, modular cover plates with frames on top for housing the switches, socket outlet etc. including taking down old point wiring,complete all as specified and directed. 80 Deduction to be made from BOQ for Schedule A Part-II (Credit Schedule from dismantling / taking down items) worth Rs 82,060.00 during AOC. (Note :- Tenderers shall not quote for this Schedule)

Key Value

Document Fees
INR 500 /-
Tender Value
INR 34 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail