Tender For Thrissur Jilla Panchayath Project -Supply And Installation Of Motor Pumpsets For Kole /Non Kole Padashekarams (Submersible Axial Flow Pump Set). - Supply ofcentrifugal pump with following duty criteria, mono block/ close coupled with suitable electric motor TEFC, fitted on a base frame, with necessary fittings and couplings. The material of construction of impeller shall be Cast Iron/ Carbon Steel/ Bronze, and that of pump body is Cast Iron Alloy, pump shaft /shaft sleeve carbon steel /SS410.The quote should include a Panel board with suitable starter for Monoblock / close coupled pump, Voltmeter, Ammeter, MCCB, ELCB, Single phase preventer, dry run preventer, star delta timer, RYB indication lamp etc. The quote should be inclusive of all petty civil works, electrical connections, and drawings and all required paper work required for the connection from KSEB duly signed by a registered electrical wireman/supervisor. All installation should meet the KSEB / Electrical inspectorate requirement.The supply should include all accessories fittings such as bend, priming facility,Base frame ,coupling,coupling guard,flanges, necessary cables and wiring , suited for the pump in the location.All items to comply with BIS standards.The pumps must be of reputed brands. 2 For Kovilakam Kole padavunder Ammadam DivisionApproximate duty point head 8m,Minimum discharge at Duty point head: 65 lps,Power allocation: 10hp.Minimum Overall Efficiency in % : 60%The supply should include Flexible suction pipe length 8m with diameter suitable for proposed pump inlet and a flexible delivery pipe length15m with diameter suitable to the proposed pump outlet. The suction pipe shall be fitted with a PVC foot valve suitable to the proposed suction pipe.The pump must have minimum 4 star rating 3 For Edathirinji Kunji Kole padavunder kattoor DivisionApproximate duty point head 8m,Minimum discharge at Duty point head: 65 lps,Power allocation: 10hp.Minimum Overall Efficiency in % : 60%The supply should include Flexible suction pipe length 8m with diameter suitable for proposed pump inlet and a PVC delivery pipe length 15m with diameter suitable to the proposed pump outlet. The suction pipe shall be fitted with a PVC foot valve suitable to the proposed suction pipe.The pump must have minimum 4 star rating. 4 For Choroth Akkrapadam PadashekharamunderMullassery DivisionApproximate duty point head 8m,Minimum discharge at Duty point head: 65 lps,Power allocation: 10hp.,Minimum Overall Efficiency in % : 60%;The supply should include Flexible suction pipe length 15m with diameter suitable for proposed pump inlet and a PVC delivery pipe length 5m with diameter suitable to the proposed pump outlet. The suction pipe shall be fitted with a PVC foot valve suitable to the proposed suction pipe.The pump must have minimum 4 star rating. 5 For Valiyedam vattakkayal Koliapadamunder Kattakampal DivisionApproximate duty point head 8m,Minimum discharge at Duty point head: 65 lps,Power allocation: 10hp.Minimum Overall Efficiency in % : 60%The supply should include Flexible suction pipe length 8m with diameter suitable for proposed pump inlet and a flexible delivery pipe length15m with diameter suitable to the proposed pump outlet. The suction pipe shall be fitted with a PVC foot valve suitable to the proposed suction pipe.The pump must have minimum 4 star rating 6 For Thenari Thazham padashekharam (choorakkattukara)under Avanur DivisionApproximate duty point head 8m,Minimum discharge at Duty point head: 65 lps,Power allocation: 10hp, Minimum Overall Efficiency in % : 60%The supply should include Flexible suction pipe 10m with diameter suitable for proposed pump inlet and a PVC delivery pipe delivery pipe length 10m with diameter suitable to the proposed pump outlet. The suction pipe shall be fitted with a PVC foot valve suitable to the proposed suction pipe. The pump must have minimum 4 star rating. 7 For Varavatoor punarjiniunder Avanur DivisionApproximate duty point head 42m,Minimum discharge at Duty point Head: 12 lps,Power allocation: 10hp. Minimum Overall Efficiency in % : 60%The supply should include Flexible suction pipe 20m with diameter suitable for proposed pump inlet and a GI delivery pipe length15m with diameter suitable to the proposed pump outlet. The suction pipe shall be fitted with a PVC foot valve suied to site Also provide NRV and vacuum pump 1 HP with all fittings suited to site.The pump must have minimum 4 star rating. 8 For Menchira kole Kayampilly Thazham under Adatt DivisionApproximate duty point head 8m,Minimum discharge at Duty point Head: 65 lps,Power allocation: 10hp. Minimum Overall Efficiency in % : 60%The supply should include Flexible suction pipe 10m with diameter suitable for proposed pump inlet and a flexible delivery pipe length 15m with diameter suitable to the proposed pump outlet. The suction pipe shall be fitted with a PVC foot valve suitable to the proposed suction pipe.The pump must have minimum 4 star rating. 9 For Chalippuram padashekharam under Allur DivisionApproximate duty point head 8m,Minimum discharge at Duty point Head: 65 lps,Power allocation: 10hp.Minimum Overall Efficiency in % : 60%The supply should include Flexible suction pipe length 10m with diameter suitable for proposed pump inlet and a flexible delivery pipe length 5m with diameter suitable to the proposed pump outlet. The suction pipe shall be fitted with a PVC foot valve suitable to the proposed suction pipe.The pump must have minimum 4 star rating. 10 For Kalappurackal Ekkatti Lift irrigation project (Kadukuty GP)under Koratty divisionApproximate duty point head 30m,Minimum discharge at Duty point Head: 25lps,Power allocation: 15hp, Minimum Overall Efficiency in % : 60 % head range -10-35,flow rate 39 -18 lps,rpm 2900 aproxThe supply should include Flexible suction pipe length 10m with diameter suitable for proposed pump inlet and PVCdelivery pipe length 15m with diameter suitable to the proposed pump outlet. The suction pipe shall be fitted with a PVC foot valve suitable to the proposed suction pipe. The supply should includeIsolation Gate valve- 2 nos,NRV and Ball valve - 3 Nos suited to theproposed delivery pipe size, vaccum pump 1 HP with all fittings. All items to comply with BIS standards 11 For Karyampadam Lift irrigation project UnderAmballur DivisionApproximate duty point head 50m,Minimum discharge at Duty point Head: 30lps,Power allocation: 30hp, Minimum Overall Efficiency in % : 60%, rpm 2900 approxThe supply should include GI suction pipe 10m with diameter suitable for proposed pump inlet and GI delivery pipe length 15m with diameter suitable to the proposed pump outlet. The suction pipe shall be fitted with a cast Iron foot valve foot valve suitable to the proposed suction pipe.The supply should includeIsolation Gate valve- 2 nos,NRV suited to the proposed delivery pipe size,Vacuum pump 3 HP with all fittings . All items to comply with BIS standards 12 Supply ofcentrifugal pump with following duty criteria, coupled with suitable electric motor TEFC (the motor should be able to dismatle seperately in rainy season) , fitted on abase frame, with necessary fittings and couplings. The material of construction of impeller shall be Cast Iron/ Carbon Steel/ Bronze, and that of pump body is Cast Iron Alloy, pump shaft /shaft sleeve carbon steel /SS410.The quote should include a Panel board with suitable starter forclose coupled pump, Voltmeter, Ammeter, MCCB, ELCB, Single phase preventer, dry run preventer, star delta timer, RYB indication lamp etc. The quote should be inclusive of all petty civil works, electrical connections, and drawings and all required paper work required for the connection from KSEB duly signed by a registered electrical wireman/supervisor. All installation should meet the KSEB / Electrical inspectorate requirement.The supply should include all accessories fittings such as bend, priming facility,Base frame ,coupling,coupling guard,flanges, necessary cables and wiring , suited for the pump in the location .All items to comply with BIS standards.The pumps must be of reputed brands . 13 For Cherukad Padashekharam under Vallathol Nagar DivisionApproximate duty point head 22m,Minimum discharge at Duty point Head: 47lps, Head range (12m to 25m), Flow range ( 85lps to 40lps)Power allocation: 20hp, Minimum Overall Efficiency in % : 60% The supply should include allGI suction and delivery pipeslength 12m with diameter suitable for proposed pump inlet and outlet fittingexisting delivery pipe shall be connected to the new pump with all required fittings. The suction pipe shall be fitted with a cast Iron foot valve foot valve suitable to the proposed suction pipe.The supply should includeIsolation Gate valve, flanges, NRV suited to the propsoed delivery pipe size, Vacuum pump 3 HP with all fittings. 14 For Pallur North under Vallathol Nagar DivisionApproximate duty point head 22m,Minimum discharge at Duty point Head: 140lps, Head range (12m to 25m), Flow range ( 260ps to 125lps)Power allocation: 60hp, Minimum Overall Efficiency in % : 60 %The supply should include allrequired GI pipe fittings , GI pipes suitable for connection to existing GI suction pipe (OD -350mm)and GI delivery pipe( OD-300mm dia ) for smooth functionng of the system. The suction pipe shall be fitted with a cast Iron foot valve foot valve suitable to the proposed suction pipe.The supply should includeIsolation Gate valve,NRV suited to the propsoed delivery pipe size, Vacuum pump 3 HP with all fittings.