| 1 | S&F, connecting and testing in repair of 100mm Cast Iron non return (Reflux) valves flanged ends in swing type design IS-5312 part-I, K517, PN-1.6 both ends flanged etc including jointing materials of following sizes complete all as specified and directed by Engineer-in-Charge. |
| 2 | S&F connecting and testing in repair of 100mm Cast Iron foot Valves flanged ends swing type operation with rubber seat as per IS : 4038 single disc with all standard accessories and tested including replacement of nuts, bolts, washers, gaskets, packings etc complete all as specified and directed by Engineer-in-Charge. |
| 3 | S&F in repair XLPE insulated water proof multi stranded copper conductor cable 1 core 16Sqmm 1100 Volts grade ISI marked from LT Panel to Centrifugal pump motor set in borewell all as specified and directed by Engineer-in-charge |
| 4 | M&L Off load change over switch 200 Amps capacity suitable for 3 phase, 4 pole, 415 Volts with sheet steel enclosurein repairs complete all as specified and directed by Engineer-in-Charge. |
| 5 | Disconnecting, dismantling and taking aside the Pump set of 40 to 75 HP capacity for replacement of existing base frame with new one from the installed position and dismantling of existing PCC / RCC foundation and refixing the same motor by preparing sufficient PCC foundation and base frame reqiured for 40 to 75 HP pump including connecting items like nuts, bolts and setting the alignemnt of motor and pump settesting and commissioningall as specified and directed.Note: The quoted rate will be inclusive of required replacement of baseframe/MS channel and PCC / RCC for foundation. |
| 6 | All as per Item No. 05 above but for pump and motor of capacity 05 to 40 HP all as specified and directed by Engineer-in-charge |
| 7 | Supply and replace suction pipe galvanized flanged type, \"Heavy class\"\" including fittings (long socket, 90 DEGREE BEND ) 80mm dia infrom motor to UH Sump including necessary flange, cutting of thread, TAKING OUT AND REFIXING OF OLD FOOT VALVEcomplete all as specified and directed |
| 8 | All as per Item No. 07 above but for size 100mm dia all as specified and directed by Engineer-in-charge |
| 9 | S&F for power contactor with coil voltage of 240 volts, 50 cycle confirming to IS, 100 Amps, 3 pole, type MNX-70 with necessary inter connections suitable for 50 to 75 HP electric motor, testing and commissioning including removing the old existing one complete all as specified and directed. |
| 10 | All as per Item No. 09 above but confirming to IS, 85 Amps, 3 pole, 240v type MNX-50 suitable for 50 to 75 HP electric motor complete all as specified and directed. |
| 11 | S&F for spare contact kit of voltage of 440 volts, 50 cycle conforming to IS, 3 pole, type ML-2 with kit necessary inter connections suitable electric motor, testing and commissioning including removing the old existing one complete all as specified and directed. |
| 12 | All as per item No. 11 above but type ML-3, suitable for electric motor. |
| 13 | All as per item No. 11 above but type ML-4, suitable for electric motor. |
| 14 | S&F for spare coil for power contactor of 440 volts, 50 cycle confirming to IS, suitable for 40 HP to 75 HP electric motor, type ML-2/3,testing and commissioning including removing the old existing one complete all as specified and directed. |
| 15 | All as per Item No. 14 above but for ML-4 all as specified and directed by Engineer-in-charge. |
| 16 | Dismantling and strip opening the centrifugal pump including disconnecting the suction, delivery, vaccum pipe lines and coupling for repairs to pump and refixing the same after repairs including overhauling the pump set, renewal of gasket to pump suction and delivery lines, gland packing, greasing nuts, bolts and washers, Metal Sleeves, painting, replacement of bearing, etc as required for arresting any kind of water leakages including testing and commissioning complete all as specified and directed for the Pump of capacity 3.0 to 7.5 HP |
| 17 | All as per Item No. 16 above bur for Pump of capacity 12.5 to 20.0 HP. |
| 18 | All as per Item No. 16 above bur for Pump of capacity 40 HP. |
| 19 | All as per Item No. 16 above bur for Pump of capacity 50 HP |
| 20 | All as per Item No. 16 above bur for Pump of capacity 75 HP |
| 21 | S&F Non drive end bearing of suitable capacity of Pumps 75 HP |
| 22 | All as per Item No. 21 above but for Pump capacity 50 HP |
| 23 | All as per Item No. 21 above but for Pump capacity 40 HP |
| 24 | All as per Item No. 21 above but for Pump capacity 12.5 to 20 HP |
| 25 | S&F Drive end bearing of suitable capacity of Pumps 75 HP |
| 26 | All as per Item No. 25 above but for Pump capacity 50 HP |
| 27 | All as per Item No. 25 above but for Pump capacity 40 HP |
| 28 | All as per Item No. 25 above but for Pump capacity 12.5 to 20 HP |
| 29 | Taking out by disconnecting of electric and water connection of burnt monoblock / centrifugal pump motorfor rewinding with PVC insulated, super enamelled copper conductor with ‘F’ class heavy grade insulation weight and turns to achieve its full efficiency inclduing tying the winding and connecting the coils and brining the connections as that of exisitng one including applying insulating varnish, heating and backing the windings thoroughlyincluding taking down old old existing existing copper winding complete including refixing the same on its old position and testing all as specified and directed for monoblock / centrifugal pump motor of Monoblock pump motor upto 3 HP capacity( Note: Quoted rates inclusive ofof all necessary arrangement including transportaion required for the above) |
| 30 | All as per Item No. 29 above but for Monoblock pump motor 5 HP to 7.5 HP capacity |
| 31 | All as per Item No. 29 above but for Monoblock pump motor 12.5 to 20 HP capacity |
| 32 | All as per Item No. 29 above but for Centrifugal pump motor of capacity 40 to 50 HP |
| 33 | All as per Item No. 29 above but for Centrifugal pump motor of capacity 75 HP |
| 34 | Complete removal of existing treatment including preparation of old painted surfaces by washing, rubbing down and stopping of painted surfaces, painting with one coat of synthetic enamel paint of approved colour on centrifugal pump set of 40 HP to 75 HP capacity including inlet, outlet mains, couplings, sluice valve, non return valve, base plate, pulley with safe gaurd, vacuum pipe line, LT panel board and writting the MES / SM number with black paint ofsuitable size of letters complete all as specified and directed. |
| 35 | All as per item No. 34 above but for up to 20 HP centrifugal pump set. |
| 36 | Supply and fix in replacement of Copper cable lugs of following sizes complete all as specified and directed for 10 to 16 Sq mm |
| 37 | All as per Item No. 36 above but for size 20 to 50 Sq mm |
| 38 | S&F Electronic timer for suitable of 40 to 75HP Motors. |
| 39 | S&F Star Delta Starter fully automatic suitable for electric motor of capacity 20HP in Sheet-Steel Enclosure Type MN / ML for motor AC-3 Duty, 415V, 50Hz, 3-Ph comprising of main star delta starter with \"D\" range contactor & electric star delta timer complete all as specified and directed by Engineer-in-Charge. |
| 40 | All as per Item No. 39 but for motor of capacity 30HP. |
| 41 | M&L for flushingof existing borewells of any sizeupto 200 Mtrs depth with drilling compressor mounted on truckincluding surging and flushing the bore at a pressure of 7 Kg / Sqcm with compressed air andflushing the sand, mud including flushing out tree roots etc from the bore well till discharge of the fresh watercomplete all as specified and directed . |
| 42 | Disconnecting and removing the water and electric connections carefully from the existing submersible pump and motor sets of capacity 5.0 HP to 30.0 HP and taking out the pump and motor set alongwith pipes and fittings upto 1000 feet depth of bore and repair the pump / motor set and strip opening the pump and motor set for repairs / replacement of worn out spares, refixing of serviceable spares, assembling the pump set completely, testing of pump set, lowering the pump set inside the bore well after repairs, including connecting back the water and electric connections, commissioning of pump set for satisfactory operation on its full load complete all as specified and directed.Note : The spares required for repair the pump sets and rewinding of motors will be measured and paid seperately. |
| 43 | M&L for rewinding the electric motor starter or rotorwith PVC insulated,super enamelled copper conductor with ‘F’ class heavy grade insulation weight and turns to achieve its full efficiency inclduing tying the winding and connecting the coils and brining the connections as that of exisitng one including applying insulating varnish, heating and backing the windings thoroughlyincluding taking down old old existing existing copper winding complete all as specified and directed of Submersible Motor 10.0 HP |
| 44 | Supply and replace suction pipe galvanized flanged type, \"Heavy class\"\" including fittings (long socket, 90 degree bend) 65mm dia infrom motor to UH Sump including necessary flange, cutting of thread, taking out and refiing of old foot valve complete all as specified and directed |
| 45 | All as per Item No. 44 above but for size 50mm dia all as specified and directed by Engineer-in-charge |
| 46 | M&L for cleaning of under mentioned RCC over head reservoir of any height of staging by using mechanical means and scientific cleaningby carrying for cleaning process for disinfection of surfaces of Over Head Reservoir capacity 30000 Gallon to 50000 Gallon all as specified and directed by Engineer-in-Charge. |
| 47 | All as per Item No. 53 above but for Under Ground Sump capacity 20000 to 50000 Gallon |
| 48 | All as per Item No. 53 above but for Under Ground Sump capacity 100000 to 300000 Gallon. |
| 49 | Site clearance including clearing away all grass vegetation, saplings, shrubs, brushwood, undergrowth, roots, and trees not exceeding 30cm grith and removing rubbish outside the periphery of the area under clearance for hard and dense soil complete all as specified & directed by Engineer-in-charge. |