}

Tender For Construction Of Bphu At Sitai Rh Under Sitai Block In The District Of Cooch Behar. Sl2, Coochbehar-West Bengal

Zilla Parishad has published Tender For Construction Of Bphu At Sitai Rh Under Sitai Block In The District Of Cooch Behar. Sl2. Submission Date for this Tender is 15-09-2025. Septic Tank Tenders in Coochbehar West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

50980696
Tender For Construction Of Bphu At Sitai Rh Under Sitai Block In The District Of Cooch Behar. Sl2
Tender
Indian
West Bengal
Coochbehar
15-09-2025

Tender Details

Tender For Construction Of Bphu At Sitai Rh Under Sitai Block In The District Of Cooch Behar. Sl2- 1 Surface Dressing of the ground in any kind of soil including removing vegetation inequalities not exceeding 15 cm depth and disposal of the rubbish within a lead upto 75 m as directed. 2 Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. a) Depth of excavation not exceeding 1,500 mm. 3 Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work). a) With earth obtained from excavation of foundation. 4 A) Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity) 5 Supplying and laying Polythene Sheet (150gm / sq.m.) over damp proof course or below flooring or roof terracing or in foundation or in foundation trenches. 6 Pre-Constructional Anti-termite measures: Anti termite treatment to the top surface of the consolidated earth within plinth walls with chemical emulsion by admixing chloropyrofos emulsifiable concentrates (1% concentration) with water by weight at the rate of 5 Litres per sq. m. of the surface before sand bed or sub-grade is laid. Holes upto 50 mm. to 75 mm. deep at 150 mm. centre to centre both ways shall be made with 12 mm, diameter mild steel rod on the surface to facilitate saturation of the soil with the chemical emulsion. The work shall be carried out as per specification described in para 6.4 of code IS- 6313 (part -II) 1981. ( Mode of measurment will be per Sq.m of plan area of plinth treated.) 7 Treatment to the back filling of R.C.C. foundation with chemical emulsion by admixing chloropyrofos emulsifiable concentrate (1% concentration) with water by weight at the rate of 7.5 ltr. per sq.m. of the vertical surface of the substructure of each side of the foundation. The work shall be carried out as per specification as described in para 6.3.1 of code IS- 6313 (part-II) 1981 (Mode of measurement will be per sq.m. of vertical area of foundation treated). 8 25mm. thick damp proof course with cement concrete with stone chips (1:1.5:3) [with graded stone aggregate 10 mm nominal size] and admixture of water proofing compound as per manufacturers specification followed by two coat of polymer based paint, (1st coat after 4 to 5 days of concrete laying and 2 nd coat just before brick masonry work) as directed (cost of water proofing compound & polymer based paint to be paid separately).( Chequering not required over concrete or painted surface).[Note: - Waterproofing as per item 9, polymer based paint as per item 8 (a) of subhead C of Section (C). 9 Single brick flat soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with powdered earth or local sand. 10 Cement concrete with 30 mm down graded shingles1:3:6 proportion. North Bengal Variety. In Ground floor 11 Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes. North Bengal variety. In ground floor and foundation. 12 In first floor 13 In second floor 14 Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction.TATA/SAIL/RINL.In foundation & ground floor 15 In first floor 16 In second floor 17 Hire and labour charges for shuttering with centreing and necessary staging upto 4 m. using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, lintels curved or straight including fitting, fixing and striking out after completion of works.Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete work.In foundation & ground floor. 18 In 1st floor 19 In 2dfloor 20 Brick work with 1st classBricks with cement morter (1:6).In foundation and plinth. 21 (b) In superstructure, ground floor 22 (c) In 1st floor 23 (d) In 2dfloor 24 125 mm. thick brick work with 1st class bricks in cement mortar (4:1). In ground floor. 25 In 1st floor 26 In 2nd floor 27 Labour for Chipping of concrete surface before taking up Plastering work. 28 Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints or rougening of concrete surface, including throating, nosing and drip course where necessary. 20 mm. thick plaster (6:1). In ground floor. 29 In first floor 30 In second floor 31 15 mm. thick plaster (6:1). In ground floor 32 In first floor 33 In second floor 34 10 mm. thick plaster (4:1). In ground floor. 35 In first floor 36 In second floor 37 Neat cement punning about 1.5mm thick in wall, dado, window sill, floor etc. NOTE:Cement 0.152 cu.m per100 sq.m. 38 Artificial stone in floor, dado, staircase etc with cement concrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (1:2) including smooth finishing and rounding off corners including raking out joints or roughening of concrete surface and application of cement slurry before flooring works using cement @ 1.75kg/sq.m all complete including all materials and labour.In ground floor. 3 mm. thick topping (High polishing grinding on this item is not permitted with ordinary cement).Using grey cement.25 mm. thick. In ground floor. 39 In second floor 40 Extra cost of labour over grey artificial stone for Chequering 41 Extra rate for using water proofing and plasticising admixture @ 0.2% by weight of cement (or at manufacturers specified rate) for concrete of variousgrades. 42 Supplying and laying true to line and level vitrified tiles of approved brand (size not less than 600 mm X 600 mm X 10 mm thick) in floor, skirting etc. set in 20 mm sand cement mortar (1:4) and 2 mm thick cement slurry back side of tiles using cement @ 2.91Kg./Sqm or using polymerised adhesive(6 mm thick layer applied directly over finished artificial stone floor/Mosaic etc without any backing course) laid after application slurry using 1.75 Kg of cement per Sqm below mortar only, joints grouted with admixture of white cement and colouring pigment to match with colour of tiles / epoxy grout materials of approved make as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials, labour and all other incidental charges complete true to the manufacturers specification and direction of Engineer-in-Charge. (White cement, synthetic adhesive and grout material to be supplied by the contrractor.] With application slurry @1.75 kg/ Sq.m, 20 mm sand cement mortar (1:4) & 2 mm thick cement slurry at back side of tiles, 0.2 kg/ Sq.m white cement for joint filling with pigment. Light Colour. Ground floor. 43 18 mm. to 22 mm. thick, kota stone slab set in 20 mm thick (avg) cement mortar (1:4) in floor, stair & lobby including pointing in cement slurry with admixture of pigment matching the stone shade, including grinding & polishing as per direction of Engineer - in - charge to match with the existing work. [Slurry for bedding @ 4.4 kg/Sq.m and pointing @2.0kg/Sq.m]. Floor. Ground floor 44 Supplying,fitting & fixing granite slab 15mm to 18mm thick in floor, lobby, stair, landing and treads etc. over 20mm (avg) thick base of cement morter (1:2) laid with white cement slurry @ 4.40Kg per Square meter before placing of granite and jointed with white cement slurry @ 2.0 Kg per square meter with necessary pigments and complete as per direction of Engineer-in-charge including cost of all materials, labours, curing and roughening of concrete surface complete.In ground floor. Area of each Granite slab above 1.00 Square meter. 45 In First Floor 46 Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc.Floor. With Sand Cement Mortar (1:4) 20 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @0.20kg /Sq.m. Area of each tile upto 0.09 Sq.m. Other than Coloured decorative including white 47 Wall - With Sand Cement Mortar (1:3) 15 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m. Area of each tile upto 0.09 Sq.m. Other than Coloured decorative including white 48 Rendering the surface of walls and ceiling with white cement based wall putty (thickness not less than 1.5 mm.). Interior surface. In Ground 49 Acrylic Distemper to interior wall, ceiling with a coat of solvent based interior grade acrylic primer (as per manufacturers specification) including cleaning and smoothning of surface. Two coats 50 Applying Exterior grade Acrylic primer of approved quality and brand on plastered or concrete surface old or new surface to receive decorative textured( matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturers specification and as per direction of the EIC.Two coats.In ground floor. 51 In first floor 52 In second floor 53 Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturers specification and as per direction of EIC to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. Two coats. Super Protective 100% Acrylic Emulsion.In ground floor. 54 In first floor 55 In second floor 56 Supplying, fitting and fixing fibre reinforced polymer (FRP) Composite door frame as per approved section with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) to safisfy IS: 4020 door testing performance criteria (i) 66mm x 90mm 57 Supplying, fitting & fixing fibre reinforced polymer (FRP) Composite door shutters as per approved design with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) to satisfy IS:4020 door testing performance criteria.25 mm thick.In ground floor. 58 In first floor 59 Collapsible gate with 40mm x 40mm x 6mm Tee as top and bottom guide rail, 20mm x 10mm x 2mm vertical channels 100mm apart in fully stretched position 20mm x 5mm M.S. flats as collapsible bracings properly rivetted and washered including 38mm steel rollers including locking arrangements, fitted and fixed in position with lugs set in cement concrete and including cutting necessary holes, chasing etc. in walls, floors etc. and making good damages complete. In ground floor. 60 M.S. gate of Jail type as per approved design made of strong M.S. frame work, intermediate stiffeners and round / square bars or angles. M.S. sheet (not less than 14 gauge) gussets, cleats etc. including necessary riveting, bolting, welding, locking and hanging arrangements, fitting and fixing complete as per direction of the Engineer-in -charge.In Second floor. 61 M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs .Grill weighing above 10 Kg./sq.mtr and up to 16 Kg./sq. mtr.In ground floor. 62 In first floor. 63 Supplying, fitting and fixing Stainless Steel railing consist of 38mm dia and 900mm height vertical balustrade at every two alternative steps, 50mm dia top rail, 3 (three) nos 19mm dia horizontal Strainless steel pipe and base/cover plate with Strainless Steel GRADE 304 containing 7.5% nickle (Interior Grade) Brushed/Mat finish, complete as per direction of the Engineer-in-charge. Weight of Strainless Steel railing per metre 6.5 Kg (approx). 64 Priming one coat on steel or other metal surface with synthetic enamel/ oil bound primer of approved quality including smooth ening surfaces by sand papering etc. 65 Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary with super gloss (hi-gloss) - On steel or other metal surface : Two coats (with any shade except white). 66 Supplying,fitting & fixing of 2-Track / 3-Track Aluminium sliding Window of all Aluminium sections viz. window frame (top,bottom & side frame), shutter (top, bottom, side & interlock member) made of aluminium alloy extrusions conforming to IS 733-1983 & IS 1285-1975, annodised conforming to IS 1868-1983, fitted with all other accessories viz. PVC roller, EPDM gasket, maruti lock, screws etc. including labour charges for fixing of glass (excluding cost of glass) all complete as per architectural fitting & fixing of aluminium 2-track/3-track sliding window with drawings and direction of Engineer-in-charge. 10-12 Micron thickness Annodizing film. Natural White. 2-track sliding window + b) 3-track sliding window. 67 Supplying, fitting & fixing of partly glazed partly panelled or fully glazed single leaf Aluminium swing door of all aluminium sections viz door frame ( top and side frame), shutter( top rail, bottom rail, lock rail, door vertical),glazing clip made of Aluminium Alloy Extrusions conforming to IS: 733-1983 and IS: 1285-1975, annodized conforming to IS:1868-1983, fitted with all other accessories viz. EPDM gusket,cleat, angle screws etc. including labour charges for fitting and fixing of aluminium door with door spring,/aluminium hinges, glass / Panel board all complete as per architectural drawings and direction of Engineer-incharge. ( Excluding cost of glass/ panel board, door spring/ Al hinges, door closer, door stoper, handle, tower bolt and locking arrangment etc) 10-12 Micron thickness Annodizing film Natural white 68 Supplying profiles of required section made of Aluminium Alloy Extrusions conforming to IS: 732-1983 and IS: 1285- 1975; Annodized (with required film thickness and specified colour / natural) matt finished conforming to IS: 1868-1983 for fabrication of composit door, sliding & casement windows, partitions, formed of basic sections of any ISI embossed / certified make and brand as per direction of Engineer - In-Charge. (Payment will be made on finished length of the work). 10-12 Micron thickness annodizing film. Natural White. Louvered window. Top, bottom and sidemember 69 Louvered Section. 70 Cleat angle ( Non-annodized) 71 Fixed Glazing - Top, bottom and side member. 72 Mullion. 73 Glazing clip. 74 Anodised aluminium butt hinges of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 205/66) and fitted and fixed with cadmium plated screws: (vii) 100 x 75 x 4.00 mm 75 Supplying 4 lever mortice lock of any approved make and brand as per direction of the Engineer-in-Charge. 100 mm. 76 Labour charges for fabrication and installation of composite door, window, partitions made from annodized extruded alloy aluminium sections for the following units. fixed glazing 77 Louvered window 78 Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987. 4 mm thick clear glass. 79 8 mm thick coloured / tinted / smoke glass. 80 Providing, fitting and fixing in position, medium density fibre board conforming to IS: 12406-1988 for plain and IS: 14587-1998 for prelaminated made of wood fibre bonded with Urea formaldehyde for interior grade and Phenol Formaldehyde for exterior grade conforming to per IS:848-1974 as per approved make and brand as per direction of Engineer-in-Charge.Both side decorative lamination. Interior Grade. 12mm. In Ground Floor. 81 In First Floor 82 Anodised aliminium D-type handle of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 230/72) fitted and fixed complete: With continuous plate base (Hexagonal/ Round rod). 125 mm grip x 10 mm dia rod. 83 Anodized aluminum barrel / tower / socket bolt (full covered) of approved manufactured from extruded section conforming to I.S. 204/74 fitted and fixed with cadmium plated screws: 225 mm long x 10 mm dia. Bolt. 84 150 mm long x 10 mm dia. bolt. 85 Iron hasp bolt of approved quality fitted and fixed complete (oxidised) with 16 mm dia rod with centre bolt and round fitting.250 mm long. 86 Supplying, fitting & fixing UPVC pipes A- Type and fittings conforming to IS:13592-1992 with all necessary clamps nails, including making holes in walls, floor etc. cutting trenches in any soil through masonry concrete structures etc if necessary and mending good damages including joining with jointing materails (Spun Yarn, Valamoid/Bitumen/M-Seal etc) complete.UPVC Pipes:110 mm. Dia. 87 Plain Tee: 110 mm. Dia. 88 Plain Y: 110 mm. Dia. 89 Bend 87.5 degree: 110 mm. Dia. 90 Shoe: 110 mm. Dia. 91 Providing and fixing exterior quality Aluminium Composite Panel (ACP) wall cladding on existing Al. /MS frame work with GI brackets, ACP fixed on the existing frame work by folding the edges of ACP anel (Engraving the rear surface of ACP sheet) with CP angles, cleats and strainless Steel screws forming groves at the periphery of ACP panel. Such grooves filled with foam and silicon sealant etc. complete with all materials (but including the cost of silicon sealant), labour, scaffolding and all other incidental charges complete in all respect as per specification and direction of Engineer-in-charge. (Mode of payment is on finished surface area of ACP). 3mm thick (0.25mm Al.+2.5mm LDPE +0.25mm Al. PVDF coating 92 SANITARY & PLUMBING WORKS Supplying, fitting and fixing PVC pipes of approved make of Schedule 80(medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew,reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc.complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately.For Exposed Work. PVC Pipes. 40 mm 93 For Concealed Work. PVC Pipes. 15 mm 94 20 mm 95 25 mm 96 Supplying ,fitting and fixing peets valve fullway gunmetal standard pattern best quality of approved brand bearing isi markings with fittings (tested to 21 kg per sq.cm). 15 mm dia 97 viii) 20mm 98 (vii) 25 mm dia 99 Supplying, fitting and fixing CPVC (Chlorinated Polyvinyl Chloride) pipes of approved make conforming to IS-15778: 2007 . with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longs crew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, fitting, fixing etc. complete in all respect including cost of all necessary fittings as required, jointing materials in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials.For Concealed Work CPVC Pipes Class-1,SDR-11. 15 mm 100 Supplying, fitting and fixing bib cock or stop cock. Chromium platedbib cock short body (equivalent to code no. 511 & model- tropical./ sumthing special of ESSCO or similar brand) 101 Chromium plated angular stop cock with wall flange (equivalent to code no. 5053 & model- Florentine of Jaquar or similar brand) 102 Supplying P.V.C water storage tank of approved quality with closed top with lid(black)-Multilayer. 2000 litre capacity. 103 Labour for hoisting plastic water storage tank. 104 Supplying fitting & fixing 10 ltr. PVC low down cistern conforming to I.S specification with PVC fittings complete C.I brackets including two coats of painting to bracket etc. 105 Labour for punching hole in plastic water storage tank up to 50 mm dia. 106 Supplying, fitting and fixing white vitreous china best quality approved make wash basin with C.I. brackets on 75 mm X 75 mm wooden blocks, C.P. waste fittings of 32 mm dia., one approved quality brass C.P. pillar cock of 15 mm dia., C.P. chain with rubber plug of 30 mm dia., approved quality P.V.C. waste pipe with C.P. nut 32 mm dia., 900 mm long approved quality P.V.C. connection pipe with heavy brass C.P. nut including mending good all damages and painting the brackets with two coats of approved paint. 550 mm X 400 mm size. 107 Supplying, fitting and fixing White Vitreous China Sink in position on C.I. brackets including two coats of painting of brackets. Laboratory sink with rim and overflow. 450 mm X 300 mm X 150 mm 108 Supplying,fitting and fixing approved brand P.V.C. CONNECTOR white flexible, with both ends coupling with heavy brass C.P.nut,15 mm dia. 450mm long. 109 Suppling fitting & fixingapproved brand 32mm dia PVC waste pipe with PVC coupling at one end fitted with necessary clamps. 900 mm long 110 Suppling fitting & fixing15 mm swan neck tap with left & right hand operating knob with aerator. 111 Supplying, fitting and fixing pillar cock of approved make. CP Pillar Cock - 15 mm. (Equivalent to Code No. 507 & Model - Tropical / Sumthing Special of ESSCO or similar brand). 112 Suppling fitting & fixing with cement jointing (3:1) salt glazed stoneware pipe including excavation of earth upto 1.50 m depth in all sorts of soil both mixed or un mixed and refilling (but excluding concerting at bottam and sides). 150 mm. 113 Suppling fitting & fixing with cement jointing (3:1)with jute gasket soaked in cement mortar. Stoneware bend. 150 mm 114 Stoneware single T & Y junction. 150 mm 115 Suppling fitting & fixing CI round grating.100 mm 116 Supply of UPVC pipes (B type )& fitting conforming to IS 13592-1992. Single socketed 3 Mtr. length -- 110 mm. 117 Labour for fitting and fixing U.P.V.C. pipes for above ground work including cost of jointing materials etc. fitting and fixing all necessary cutting pipes, cutting holes in walls or R.C. floor where necessary and mending good all damages excluding the cost of masonry or concrete work, if necessary, but including the cost and fitting and fixing holder bat clamps (any floor) or for underground work including cutting trenches upto 1.5 metre and refilling the same complete as per direction of the Engineer-in-charge. (Payment will be made on centre line measurement of the total pipeline including specials. Above ground. 110 mm dia. 118 Under ground. 110 mm dia. 119 FITTINGS Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992. Double Y with Door. 110 mm. 120 Door bend ( T.S.).110 mm. 121 Vent cowl- 110mm 122 Pipe clip ---(b) 110 mm 123 Plain Tee---(b) 110 mm 124 Suppling fitting & fixing E.W.C in white glazed vitreous china ware of approved make supplied fittied complete in position with necessary bolts nuts.etc. with P trap. 125 Supplying fitting & fixing closet seat of approved make with lid & C.P hinges,rubber beffer & brush screw complete. E.W.C. Plastic (hallow type) white 126 Supplying fitting & fixing 32 mm. dia. flush pipe of approved make with necessary fixing materials & clam complete.Polythene flush pipe. 127 Supplying, fitting and fixing liquid soap container.Fibre glass. 128 Supplying fitting & fixing best quality indian make mirror 5.5 mm thk. With silvering as per I.S.I specification supported on fibre glass frame of any colour,frame size 550mm x 400mm 129 Supplying fitting & fixing towel rail with two brackets.C.P over brush-25 mm dia,450 mm long. 130 Constructing inspection pit of inside measurement 600mm x600mm x upto 600mm (depth) with 250mm th. 1st. Class brick work in cement mortar(1:4) on all sides bottom of the pit consisting of 100 mm th. Cement concrete (1:3:6) with stone chips over a layer of jhama brick fklat soling, 15 mm thk. (4:1) cement plaster to bottom of the pit providing necessary invert with cement concrete (1:3:6) with stone chips as per direction ,neat cement finishing to entire internal surface top of the pit convered with 100 mmth. R.CC slab (1:1.5:3) with stone chips and necessary reinforcement upto 1% and shuttering including 6mm thk.cement plaster (1:4) in all external surfaces of the slab and one 560 mm dia .R.C.C manhole cover of approved make supplied ,fitted and fixed in the slab with necessary fittings, necessary earthwork in excavation in all sorts of soil, filling sides of the pit with earth removing spoils after work complete in all respect with all costs of labour and materials.i) With North Bengal variety (SAIL/TATA/RINL) 131 Construction of circular soak well 2.5 m deep inall types of sandy soils with dry brick work upto 1:6 m from the bottom having 150mm intermediate cement brick work(1:4) band all round and cement brick work (1:4) upto .90m from top with 20mm thk. Cement plastering (4:1) to inside face upto the depth of cement brick work, 15 mm th.cement plaster (1:4)on outer face from top of the well upto G.L and 6mm thk. cement plaster (1:4) on top of the R.C.C cover slab including filling bottom 1.0m of inside of the well with brick metal (501mm to 63mm size) including R.CCcover slab of designed thk. with cement concrete b(1:1.5:3) with stone chips with necessary. reinforcement and shuttering including one 560 mmdia .R.CC manhole cover(heavy type) of approved make supplied ,fittings making necessary arrangements for pipe connections ,excavation of well including shoring, dewatering and removing the exess earth from the premises as per direction complete in all respect with all costs of labour and materials.With 250mm thk.dry brick work and 250 mm thk. cement brick work (6:1) and 1.00 m inside dia. For-SAIL/TATA/RINL 132 Construction of septic tank of different capacities as per approved drawing with 1st class brick work in cement mortar (1:4) including two 560 mm dia. R.C.C. manhole cover(heavy type)of approved make supplied, fitted and fixed in the 100mm thick R.C.C (1:1.5:3) top slab with necessary fittings, 20mm thick cement plaster (4 : 1) with neat cement finish to the internal surfaces and 15 mm thick cement plaster (4 : 1) to outside wall upto 200 mm below G.L floor finished with 25 mm thick grey artificial stone over 100 mm thick R.C.C.For 20 users.With North Bengal Variety (SAIL/TATA/RINL) 133 Cement concrete with 30 mm down graded shingles in ground floor North Bengal Variety. 1:3:6 Poportion. 134 Supply fitting and fixing Fire Exyinguisher Conforming to ISI marked ( IS 15683:2006) ABC type fire extinguisher stored pressure type of 6 kgs. Capacity , with initial filling in brand new cylinder with poder coated finish , fitted with gun metal union , discharge hose , wall mounting bracket and suitable sinage etc. complete ( Make: Fire Shield / New age / De Flame / Andex or equivalent ). A level should be pasted on the body of the Extinguisher duly signed & stamped by the Agency stating 1. Date of Installation 2. Date of Expiry/ Date of next refilling.( warranty card need to be submitted ) 135 DGSET DOUNDATION Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. Depth of excavation not exceeding 1,500 mm. 136 Single brick flat soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with powdered earth or local sand. 137 Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity). 138 Cement concrete with 30 mm down graded shingles excluding shuttering. 1:3:6 Proportion. In Ground Floor. North Bengal Variety. 139 Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS code. River Bazree.In ground floor. 140 Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. In foundation & ground floor. TATA/SAIL/RINL. 141 Hire and labour charges for shuttering with centreing and necessary staging upto 4 m. using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, lintels curved or straight including fitting, fixing and striking out after completion of works. 25 mm to 30 mm thick wooden shuttering as per decision & direction of Engineer-In-Charge. In Ground floor 142 Brick work with 1st classBricks with cement morter (1:6). In foundation and plinth. 143 Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints or rougening of concrete surface, including throating, nosing and drip course where necessary. With 1:6 cement morter15 mm thick plaster. In ground floor. 144 Neat cement punning about 1.5mm thick in wall, dado, window sill, floor etc. NOTE:Cement 0.152 cu.m per100 sq.m. 145 ELECTRICAL WORKSDistn. wiring in 22/0.3 (1.5 sqmm) single core stranded FR PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to light/fan/call bell points with Piano key type switch (Anchor make) fixed on sheet metal (16 SWG) switch board with bakelite/perspex (wall matching colour) top cover (3 mm thick) flushed in wall incl. mending good damages to original finish.2x22/0.3 (Ph. & N) and 1x22/0.3 as ECC ,Average run 6 mtr 146 Average run 7 mtr 147 Average run 8 mtr 148 Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded FR PVC insulated & unsheathed copper wire (Brand approved by EIC) in suitable size PVC casing-capping (Precision make) with 1x22/0.3 (1.5 sqmm) single core stranded FR PVC insulated & unsheathed copper wire for ECC, incl. necy. PVC clips, fittings etc. to light point with 2 no. 2 way piano key type switch fixed on sheet steel fabricated switch board with Perspex/bakelite top cover on wall incl. necy. connections and making earthing attachment and mending good damages to building works [PVC casingcapping on surface and Switch board concealed]Average run 9 mtr 149 Supplying and Drawing 1.1 KV single core stranded FR PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required 2 x 22/0.3 (1.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC 150 2x36/0.3 (2.5 sqmm) + 1x22/0.3 (1.5 sqmm) as ECC [power& 20A board] 151 2x56/0.3 (4 sqmm) + 1x36/0.3 (2.5 sqmm) as ECC [6+20A Power Board] 152 2x84/0.3 (6 sqmm) + 1x56/0.3 (4 sqmm) as ECC [HTPN DB TO SPN DB] 153 4x80/0.4 (10 sqmm) + 2x84/0.3 (6 sqmm) as ECC [UPS] 154 3x126/0.4 (16 sqmm) + 2x80/0.4 (10 sqmm) as Neutral, ECC [FUSE BASE to LT Panel] 155 Supplying and fixing polythene pipe complete with fittings as necy.. under ceiling/beam, bound with 22 SWG GI binding wire incl. supplying and drawing 1x18 SWG GI Wire as fish wire inside the pipes and fittings and providing 50 mm dia disc of MS sheet (20 SWG) having colour paint at one face fastened at the load point end of the polythene pipe with fish wire (synchronizing with roof/beam casting work of building construction).19mm dia 3mm thick Polythene Pipe 156 25mm dia 3mm thick Polythene Pipe 157 Cutting channel of 31mm x 31 mm size on masonry wall incl. S&F heavy gauge polythene pipe dia as stated below, by means of iron hooks and supplying and drawing 18 SWG GI Wire as fish wire incl. mending good damages to building works19 mm dia 3 mm thick polythene pipe without earthcontinuity wire 158 Cutting channel of 43 mm x 43 mm size on masonry wall incl. S&F heavy gauge polythene pipe dia as stated below, by means of iron hooks and supplying and drawing 18 SWG GI Wire as fish wire incl. mending good damages to building works.25 mm dia 3 mm thick polythene pipe without earth continuity wire 159 Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.2.5 sqmm 160 4 sqmm 161 6 sqmm 162 16 sqmm 163 Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded FR PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to 240 V 5A 3 pin plug point incl. S&F 240 V 5A 3 pin flush type plug socket & piano key type switch (Anchor make) incl. S&F earth continuity wire, fixed on sheet metal (16 SWG) switch board with bakelite/perspex (wall matching colour) top cover (3 mm thick) flushed in wall incl. mending good damages to original finish.2x22/0.3 (Ph. & N) and 1x22/0.3 as ECCOn Board 164 Average run 6 mtr 165 Supply & Fixing 240 V, 20A, plug socket with separate 20 A Piano key type switch (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 150x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required [Separate 20A Switch Board] 166 Supply & Fixing 240 V, 4 nos. 6A, plug socket with separate 4 nos. 6 A Piano key type switch, indicator & 16A switch type SP MCB (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 240x200x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessaryconnections as required [CPU Board] 167 Supply & Fixing 240 V, 2 nos. 6A, & 2 nos. 20A plug socket with separate 2 nos. 6 A & 2 nos. 20A Piano key type switch, indicator & 20A switch type SP MCB (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 240x200x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required [Power Point] 168 Supply & Fixing 240 V, 25A Modular type socket, 25 A, Modular type starter (Havells/Legrand/L&T-Brand approved by EIC) with 25A Modular switch type DP MCB (C-Curve) and 6 Module GI Modular type switch board with 6 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. [AC Board] 169 Main LT Panel :- Supply, delivery, installation, testing & commissioning of Indoor Cubical type L.T. Distribution panel board of required size, wall/stand mounted compartmentalized with maple arrangement having rigid & self supporting structure with cable alley fabricated from 2 mm thick CRCA sheet steel and 35x35x5 mm M.S. angle frame for panel mounting support and making necessary grouting arrangements with neet cementing finish as per direction of EIC. [Dim. - 1600mm x 1450mm x 350mm]. The panel board consisting of the following item:- 415V, 200A electrolyte grade tinned copper BBC (Raw power Busbar & D.G. Busbar) with vertical section of 25X6mm sizefor neutral & Phases. Bus-bars shall be fixed with FRP insulator chair & seperator & the entire bars are insulated with PVC heat Sinkable sleeve of suitable size & color as per direction of E.I.C. [equal bar for each i.e. 4-bar]and interconnections for:- 125A FP MCCB and all inter-connecting links should be made with suitable size copper strip/copper wire.A) Incomming Arrangement: a) 415V 125A FP MCCB Breaking Capacity:- 25kA/35kA with fixed thermal & fixed magnetic/adjustable thermal & fixed magnetic setting, panel mounting cubicle type conform to IS :13947, Make- Legrand/Havells/L&T/BCH-01 no.B) Bus Section:415V, 200A electrolyte grade tinned copper bus bar, with vertical section of size 25x6mm for Phase RYB, neutral bars of each. A bus bar shall be fixed with FRP chair & the entire bars are insulated with PVC heat Sinkable sleeve of suitable size & color as per direction of E.I.C. - 02 nos.C) Outgoing Arrangement:a) 415V 125A FP MCCB Breaking Capacity:- 25kA/35kA with fixed thermal & fixed magnetic/adjustable thermal & fixed magnetic setting, panel mounting cubicle type conform to IS :13947, Make- Legrand/Havells/L&T/BCH -03 nos.b) 415V 125A TPN On load Changeover switch, front operated Changeover switch in open execution type, Make- Legrand/Havells/L&T/BCH 01 no.c)Triple Pole 63A MCB (Legrand/Havells/L&T/BCH) -03 nos.d)Triple Pole 40A MCB (Legrand/Havells/L&T/BCH) -01 no.e)Double Pole 32A MCB (Legrand/Havells/L&T/BCH) -04 nos.f) Single Pole 6-32A MCB (Legrand/Havells/BCH) -08 nos.D) Metering Panel:a) S&F 3-ph digital single function panel meter, Voltmeter (L&T)- 02 nos.b) S&F 3-ph digital single function panel meter, Ammeter (L&T) - 02 nos.c) S&F 200/5A 15VA Class-1 C.T. (KAPPA) - 06 nos. d) S&F Gen next LED phase R-Y-B indicator-Make-L&T 06 nos. e) S&F 6A SP MCB (c-curve)-Make-Legrand/Havells/L&T/BCH06 nos.f) S&F 08X06 Danger Board02 nos.E) Cable Alley:Cable entry arrangement will be provided in the cubicle panel in vertical position of size 1450mm x 350mm x 350mm with suitable capacity 4 way AC/DC connector indicating phase & neutral for each outgoing main switches & gland plate must be placed at the bottom of the panel with detachable type as per direction of E.I.C. 170 Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment (Legrand / Havells / Siemens/L&T). 6 way [Enclosure (LTTD06N)] [EDB-1, Gr. Fl., EDB-2, NDB-2, 1st Fl.] 171 8 way [Enclosure (LTTD08N)] [NDB-1, Gr. Fl.] 172 8 way HTPN DB 173 Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment.(Legrand / Havells / Siemens/L&T)(2+16 Way) Enclosure [ELDB1-Gr. Fl., ELDB 2-1st Fl.] [Enclosure (607713)] 174 (2+12 Way) Enclosure [LDB 1Gr. Fl., LDB 2-1st Fl.] [Enclosure (607712)] 175 Supplying and fixing MCB SS enclosure with IP-20/30 protection, powder coated provision for two/four pole MCB, concealed in wall after cutting the wall & mendinggood the damages to original finish incl. painting, connection & provision for earthing attachment. 4 Way [UPS: I/C & O/G] 176 Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection. [Make - Legrand/Havells/L&T/Siemens] Single pole 6-32A MCB [NDB 1,2, EDB 1,2, ELDB 1,2, LDB 1,2 O/G] 177 Single pole 32A MCB [EDB 1,2 O/G - ELDB 1,2] 178 Single pole 40A MCB [NDB 1,2 O/G - LDB 1,2] 179 Four pole 63A MCB Isolator [NDB 1,2 I/C] 180 Four pole 40A MCB Isolator [EDB 1,2 I/C] 181 Four pole 40A MCB [UPS 4 WAY I/C & O/G] 182 Double Pole 40A MCB Isolator [UPS O/G, LDB 1,2 I/C] 183 Double Pole 32A MCB Isolator [ELDB 1,2 I/C] Make-Legrand 184 Supply of 2 mm thick wooden ply board of size 3 ftx2 ft and fixing the same in wall by necessary nuts, bolts etc. Incl. Supply and fixing of 3 nos. 100A, 415V, Porcelain Fuse carried and base (Havells make, cat no: IHKKRN4100) and neutral bar at wooden board. 185 Supply & Fixing Socket type fan regulator (Steptype) (Brand approved by EIC) on existing sheet metal switch board with bakelite/perspex top cover by screw after making housing for regulator knob by cutting bakelite/perspex top cover incl. making necy. connections etc. 186 Supplying & Fixing of Box type fan clamp of 150mm dia & 80mm depth made of 16 SWG CRCA sheet with one end duly sealed by cover, properly welded, incl. S&F 12mm dia 600mm long MS rod duly bent by heat treatment at the centre position of rod to grip fan bobbin properly, incl. binding the rod and fan box with reinforcement by 22 SWG steel binding wire, incl. supplying & covering the box with alkathene sheet, placed in order to prevent concrete from entering the box. 187 Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessaryconnection as required by 2x1.5 sqmm flexible copper wire. 188 Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter:30 cm (12) 189 Supply & Fixing louver shutter on wall with necy.. bolts & nuts (6 mm dia x 62 mm long) FOR AL: 30 cm Exhaust fan (12) 190 Supplying & Fixing 240 V AC Buzzer (Ancho) on HW board incl. S&F HW board 191 Fixing only cabin fan on wall/ceiling by S&F rag bolts, nuts & washers (6 mm dia x 62 mm long) or as reqd. incl. S&F 24/0.20 PVC insulated flexible copper wire 0.5 mt. length 192 Supply & delivery of Sweep:- 48 (1200mm) AC ceiling fan, 50-70 Watts, Speed:->=350 RPM, Air delivery:->=220 CMM, make: (Orient PSPO NEWBREEZE or SUMMERCOOL / equivalent of EPC or USHA STRIKER PLUS or CROMPTON [Approved by EIC] 193 Supply & delivery of Sweep:-36 (900mm) AC ceiling fan, 50-70 Watts, Speed:->=380 RPM, Air delivery:->=145 CMM, make: (Orient PSPO NEWBREEZE or SUMMERCOOL / equivalent of EPC or USHA or CROMPTON or HAVELLS [Approved by EIC] 194 Supply & delivery of heavy duty Exhaust Fan of Sweep:-12 (300mm), 240 volt, 50 Hz, AC , 50-60 Watts, Speed >900 RPM, Air delivery >=1145 CMM suitable for . [Make - Orient (Model:Power Flow) /EPC/Havells/Crompton Greaves][Approved by EIC] 195 Laying of cable from 3/3½ core 35 sqmm to 50 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making holes etc. as necy., mending good damages and painting 196 Laying of one No. cable above 35 sqmm and upto 185 sqmm in underground trench 460mm wide x 760mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per Mtr. including filling the space between the bricks and cable and also the trenchwith shifted soil, leveling up and restoringsurface duly rammed. 197 Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below : For 4 core upto 50 sqmm 198 for 4 core upto 35 sqmm 199 Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required. 65 mm dia ISI 200 Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials.4 core 50 sqmm cable 201 4 core 35 sqmm cable 202 Supplying of 1.1 KV. Grade LT power cable, XLPE insulated, cores laid up, PVC inner sheathed aluminium armoured conductor of the following specificaion:- (make: Polycab/Gloster/Havells)50 sqmm 4 core (A2XWY/A2XFY) 203 Supplying of 1.1 KV. Grade LT power cable, XLPE insulated, cores laid up, PVC inner sheathed aluminium armoured conductor of the following specificaion:- (make: Polycab/Gloster/Havells)35 sqmm 4 core (A2XWY/A2XFY) 204 Excavation of soil for installation of Earth Electrode and filling & ramming. For Morrum Soil 205 Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below:By TATA-Medium GI pipe [D.G. Body:2, D.G. Neutral: 2, LT PANEL:2, UPS: 2] 206 Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe 207 Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required. 208 Connecting the equipments body to earth busbar including S&F 20 mm x 3 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc. 209 Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages. Solid GI wire , No. 6 SWG 210 Supply & fixing of unipolar hexagonal flat mounting insulator for busbar support for fixing of neutral earth busbar at the side of D.G. foundation & location of UPS of the following specification:-i). Polyester without halogenii) UL94 VO self-extinguishing.iii) Colour red RAL 3002.iv) Operating temperature from -40 to +130°C.v) Deformation under load temperature (ASTM D643): > 200°C.vi) Dielectric constant (ASTM D150): 4/5.vii) Arc resistance (ASTM D495): > 180 s.viii) Water absorption (ASTM D570): < 0.3%. 211 Supply & Fixing RJ45 sitable for CAT6 cable (Brand approved by EIC) with PVC board and top cover plate on wall and making necessary connections & testing as required 212 Supply & Fixing Telephone socket (RJ11) Modular type (Brand approved by EIC) with PVC board and top cover plate on wall and making necessary connections & testing as required. 213 Supplying & Drawing 2-pair Telephone cables with high density polyethylene insulated solid annealed high conductivity bare copper of dia 0.5mm in prelaid PVC rigid conduit / in polythene pipe embeded in wall. 214 Supplying & Drawing LAN cable (CAT6) (Brand approved by EIC) in prelaid PVC rigid conduit/ in polythene pipe embeded in wall. 215 Supplying and fixing PVC casing-capping [Precision Make] on wall or ceiling, incl. necy. PVC fittings etc. and mending good damages to building works. 20 x 10 mm size 216 Supply & delivery of single 4ft Batten type LED tube light fitting,1200 mm, Efficacy>= 100 lm/W, THD<10%, complete with all accessories. (Havells: LED Pride Plus NXT Batten 22 W 6500 K) or equivalent of Philips, Crompton etc. [Approved by EIC] 217 Supplying & Fixing Out door type CFL/LED luminaire (Havells make-LHRC4185099 or equivalent) with deep drawn aluminium housing anodised inside & clear acrylic cover and accessories incl. for 85 watts CFL lamp / 20 watt LEDincl. S&F 32mm dia GI pipe bracket, clamp, nut & bolts etc. 218 Supply & Delivery at site 9 watt LED Bulb,Efficacy>=90 lm/W, Base Cap:-B22 [Make-Havells, LED DEKOR BULB 9 W B22 CDL] or equivalent of Crompton, Philips etc. [Approved by EIC] 219 Fixing only single /twin fluorescent light fitting complete with all accessories directly on wall/ceiling/HW round block and suitable size of MS fastener 220 Fixing only single/twin fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length. 221 Fixing only lamp

Key Value

Document Fees
Refer document
EMD
INR 107841.0 /-
Tender Value
INR 53.92 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail