Purchase And Installation Of Generator , 1 Part I- Electrification-( Materials Used For The Work Shall Be As Per List Of Materials Approved By The District Level Technical Committees And Attached As Separate Document) , Od106946/2025-2026:Supply, Loading, Conveyance, Unloading, Erection, Testing And Commissioning Of 20 Kva 3 Phase Dg Set[ Bs6 ] With Acoustic Enclosure As Per Cpcb Norms And As Detailed Below -1. Engine -. Make Of Engine -Koel / Kirloskargreen/Cummins Alternator Make Kirloskar Krilosker /Crompton/Stamford B. Type Of Engine - Diesel Engine. C. No Of Cylinders - As Per Manufactures Standards. D. Method Of Cooling - Water Cooled With Radiator. E. Aspiration - Naturally Aspirated. F. Design- Suitable For Generating Set Operation. G. Output - Suitable For Generating Set Operation. 2. Standard Accessories With Diesel Engine A. Fly Wheel. B. Close Coupled. C. Air Cleaner. D. Radiator With Fan Provided With Fan Guarded. Fuel Pumps. Mechanical Governor. G. Fuel Filter. H. Lubricating Oil Filter. I. Residential Type Exhaust Silencer. J. Battery Charger And Generator 3. Engine Instrument Panel With The Following Items. Starting Switch With Key Or Button, Lubricating Oil Pressure Gauge, Water Temperature Gauge, Rpm Indicator With Hour Meter, Battery Charging Ammeter. 4. Safety Controls For Engine- Battery Control (Trip)For Low Lubricating Oil Pressure, Battery Control (Trip) For High Water Temperature. 5. Brushless Alternator Make - Kirloskar/ Kel/Crompton/Integrated Electric Ltd, Type - Self Exited And And Self Regulated, Capacity - 20 Kva @ 0.8Pf, System Of Voltage - 3Phase, 415V, 4Wire System, Speed - 1500Rpm, Frequency - 50Hz, Insulation - Class F/H. The Alternator Should Confirm To Is 4722/Is13365.Operation And Service Manual Shall Be Provided. Fuel Tank- Suitable Size Fitted (Built In Type) Inside The Acoustic Enclosure. Battery & Inbult Battery Charger-Suitable Size Fully Charged Battery With Leads And Terminals Of Appropriate Ah Capacity As Per Manufactures Required. Standard Control Panel 32A Fpmcb, 1No Multifunction Meter Suitable For Display Of Current, Voltage , Frequency, Power Factor, Kva, Kw Etc. 1No Separate Kwh Meter, Necessary Measuring Cts Of Appropriate Ratio And Burdon For The Required Meter, Instrument Fuse/Mcb , Metallic Dnb - 1No, Solid State Phase Indication Lamp For Supply On/Of With Fuse /Mcb Protection. 3 Years Warranty For Dg.. Lub Oil & Diesel- First Full Fill Of Lube Oil And Diesel, Etc. As Required., Capacity - 20 Kva @ 0.8Pf, System Of Voltage - 3Phase, 415V, 4Wire System, Speed - 1500Rpm, Frequency - 50Hz, Insulation - Class F/H. The Alternator Should Confirm To Is 4722/Is13365.Operation And Service Manual Shall Be Provided. Fuel Tank- Suitable Size Fitted (Built In Type)Inside The Acoustic Enclosure .Battery & Inbuilt Battery Charger-Suitable Size Fully Charged Battery With Leads And Terminals Of Appropriate Ah Capacity As Per Manufactures Required. Standard Control Panel-32A Fpmcb, 1No Multifunction Meter Suitable For Display Of Current, Voltage , Frequency, Power Factor, Kva, Kw Etc. 1No Separate Kwh Meter, Necessary Measuring Cts Of Appropriate Ratio And Burden For The Required Meter, Instrument Fuse/Mcb, Metallic Dnb - 1No, Solid State Phase Indication Lamp For Supply On/Of With Fuse / Mcb Protection. 3 Years Warranty For Dg.. Lube Oil & Diesel- First Full Fill Of Lub Oil And Diesel, Etc. As Required. , 90.12.7.41:Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armoured Aluminium Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages , Colour Washing Etc. As Required.4 Core 16 Sq Mm With Factory Made Clamp , 90.12.5.41:Supply & Laying Of One Number Pvc Insulated And Pvc Sheathed Armoured Aluminium Power Cable Of 1.1Kv Grade Of The Following Sizes In The Existing Rcc/ Hume / Stone Ware/ Gi/ Dwc Pipe As Required.4 Core 16 Sq Mm , 90.12.7.40:Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armoured Aluminium Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages , Colour Washing Etc. As Required.4 Core 10 Sq Mm With Factory Made Clamp , Od538615/2024-2025:Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armoured Copper Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages , Colour Washing Etc. As Required.4 Core 2.5 Sq Mm With Factory Made Clamp , 90.12.7.2:Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armoured Aluminium Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages , Colour Washing Etc. As Required.2 Core 6 Sq Mm With Factory Made Clamp , 90.12.10.3:Supply & Laying Of Dwc Pipe In Ordinary Soil 0.75M Below Ground Level Including Excavation63/50 Mm Or Nearest Size , 9.1.1:Supplying And Making End Termination With Brass Compression Gland And Aluminium Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade As Required.2 X 6 Sq. Mm (19Mm) , 9.1.32:Supplying And Making End Termination With Brass Compression Gland And Aluminium Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade As Required.4 X 10 Sq. Mm (25Mm) , 9.1.33:Supplying And Making End Termination With Brass Compression Gland And Aluminium Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade As Required.4 X 16 Sq. Mm (28Mm) , 90.6.10.1:Supply And Fixing Of Following Sizes Of Light Gauge Pvc Conduit Along With Accessories In Surface/ Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required20 Mm , 90.6.10.2:Supply And Fixing Of Following Sizes Of Light Gauge Pvc Conduit Along With Accessories In Surface/ Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required25 Mm , 1.17.5:Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel/ Pvc Conduit As Required.5 X 1.5 Sq. Mm , 1.17.22:Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel/ Pvc Conduit As Required.4 X 4 Sq. Mm , 1.22.3:Supplying And Fixing Metal Box Of Following Sizes (Nominal Size) On Surface Or In Recess With Suitable Size Of Phenolic Laminated Sheet Cover In Front Including Painting Etc As Required.150 Mm X 75 Mm X 60 Mm Deep , Od538500/2024-2025:S & F Led Phase Indicators For All Voltage Ranges - Red,Yellow & Blue Colour , 14.1:Excavation For Foundation In Soft Soil Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 Metres. , Od538497/2024-2025:Steel Reinforcement For R.C.C Work Including Straightening, Cutting, Bending, Placing In Position, And Binding All Complete Up To Plinth Levelthermos - Mechanically Treated Bars Of Grade Fe-500D Or More(Data 5.22.6 From Civil Work) , 14.8:Providing And Laying In Position Cement Concrete 1 :3:6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size) In Foundation Of Pump, Dg Set Etc. Including Form Work Etc. As Required. , 14.10:Providing And Laying In Position Reinforced Cement Concrete 1 :2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size) In Foundation Of Pump, Dg Set Etc. Including Form Work Etc. As Required (Excluding Reinforcement). , 14.12:Providing 15Mm Thick Cement Plaster Of Mix 1:4(1 Cement: 4 Fine Sand) At All Levels , 90.14.5:Supply And Fabrication Conveyance And Installation Of Angle Iron Frame Work For Wall Mounting Panel Board , Od538489/2024-2025:Supply And Providing 65Mm Or Nearest Size C Class Ms Pipe Conforming To Relevant Is Specifications Completewith The Heavy Gauge Specials Such As Bends, Flanges, Etc, Welded And Fixed At Appropriate Locations ,Providing Cork Sheet In Between The Flanges At The Joints , Bolting The Flanges Together, Painting The Pipe , Flange Etc With 2 Coats Heat Resistant Paint Suitable For Outdoor Applications , Fixing The Pipe Firmly With Fabricated Structure, Wall / Any Other Mechanical Support Etc As Required. , Od538490/2024-2025:Supply And Installation Of63 A, 415 V, 50 Hz, Ac 23 A Duty, 4 Pole On-Load Change Over Switch In Sheet Steel Enclosure Complete With Handle Assembly, Door Interlock And Pad Locking Arrangementon Existing Angle Iron Frame Work Or Directly To Wall Using Necessary Bolts & Nuts, Fixing The Unit To Wall, Making Good The Damages, Colour Washing Etc. Including Giving Necessary Connections As Required. , 90.11.1.14:Supply And Installation Ofsheet Steel, Phosphatised And Painted, Dust And Vermin Proof Enclosure Of Mcb Db Including Copper /Brass Bus Bar, Neutral Link, Earth Bus And Din Rail Suitable For Fixing Mcb/Isolator Etc. Fixed On Wall Using Suitable Anchor Bolts Or Fixed In Recess Including Cutting Hole On The Wall , Making Good The Damages, Colour Washing Etc. As Required4 Way (8+12) - Double Cover Tpn Vertical Db With Provision For Fixing 4P Mcb / Isolator/ Rccb/ Rcbo As Incomer And Sp/ Tp Mcb As Outgoing (Ip 42/43) , 2.13.2:Supplying And Fixing Following Rating, Four Pole, 415 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.63 Amps , 2.15.3:Supplying And Fixing Following Rating, Four Pole, (Three Phase And Neutral), 415 Volts, Residual Current Circuit Breaker (Rccb), Having A Sensitivity Current Upto 300 Milliamperes In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.63 Amps , 2.10.4:Supplying And Fixing 5 Amps To 32 Amps Rating, 240/415 Volts, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.Triple Pole , 2.10.1:Supplying And Fixing 5 Amps To 32 Amps Rating, 240/415 Volts, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.Single Pole , Od539272/2024-2025:Supplying And Fixing 40A, Double Pole, 240 Volts, Center Off Cos In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. , Od106966/2025-2026:Earthing With G.I.Earth Plate 600Mmx600mmx6mm Thick With Watering Pipe 1.7 Metre Long And Test Joint Using 2 Nos,25X3mm Gi Strip With Sufficient Drilled Holes Minium Size 25 Cm Suitably Shaped And Tightly Clamped To The Watering Pipe Using 25X6 Mm Steel Bolts Nut And Washer And Providing 2 Nos,20X3mm Gi Strip From Tet Joint To Earth Plate Bottom Level Clamped At 2 Locations On The Plate And On The Test Joint Bolted With Steel Bolts,Nuts Etc.Provid.Ing Gi Funnel Welded With The Watering Pipe And Making Masonry Chamber Built With Bricks And Duly Plastered And Providing Cast Iron Cover Plate Etc Complete. , 90.16.2.1:Supply And Laying Of The Following Sizes Of B Class Gipipe Laid 0.6 M Below Ground Level Including Excavating Trench Of Suitable Size And Refilling Etc, As Required.15.Mm Dia. G.I Pipe ( Medium Class) , 90.16.3.8:Supply And Clamping The Following Size Of Strips On Surface Of Wall/ Parapet/ Existing Cable Tray Using Clamps Fabricated From 20 X 3 Mm Gi Flat Duly Painted Or Heavy Duty Gi Spacer Saddles Spacing Of Clamps Not Exceeding 1 M, Making Good The Damages, Colour Washing Etc. As Required ( For Horizontal Run)20 X 3 Mm Copper Strip , 90.16.1.2:Supply And Drawing Bare Earthing Conductors Of The Following Sizes Along With Wiring/ Cables And Giving Connection As Required2.65 Mm Copper Conductor (12 Swg) , 90.16.1.3:Supply And Drawing Bare Earthing Conductors Of The Following Sizes Along With Wiring/ Cables And Giving Connection As Required3.15 Mm Copper Conductor ( 10 Swg) , 90.16.5.2:Supply Of Superior Quality Copper Earth Socket For The Following Size Of Earth Conductor Including Crimping Etc. As Required.2.65 Mm (12 Swg) , 90.16.5.3:Supply Of Superior Quality Copper Earth Socket For The Following Size Of Earth Conductor Including Crimping Etc. As Required.3.15 Mm (10 Swg) , Od538491/2024-2025:Supply And Providing 12X3 Mm Brass Bolt And Nut With Washers On The Existing Ms Box / Earth Bus Etc. As Required Including Drilling Necessary Holes As Required , Od538498/2024-2025:Supply And Providing 25X6 Mm Brass Bolt And Nut With Washers On The Existing Ms Box / Earth Bus Etc. As Required Including Drilling Necessary Holes As Required , Od538487/2024-2025:Preparation Of Drawing Including Schematic Circuit Diagram For Necessary Approval From The Electrical Inspectorate , Od538493/2024-2025:Charges Towards The Electrical Inspectorate For Approval Of Necessary Plan, Scheme And Other Related Papers , Od538499/2024-2025:Supply And Providing 2Mm Thick Elastomeric Fire Retardent Insulating Mat As Per Is 15652/2006 To Withstand 3.3 Kv Dielectric Strength. , Od538495/2024-2025:Supply And Providing 9 Litre Capacity Gi Fire Bucket Painted In Post Office Red With Primer Coat Of Red Oxide And Written With White Paint 'Fire' Mounted On Ms Angle Frame Work/ Wall Bracket Filled With Fine Sand, Painting The Bracket/ Floor Stand Including Making Good The Damages, Colour Washing Etc. As Required. , Od538488/2024-2025:Aluminium Anodised Danger Notice Board Of Size 200 X 150 Mm. With Inscriptions ( Both In English And Malayalam) Andconventional Skull And Bone In Red Colour. , Od539355/2024-2025:Supply And Installation Of Fire Extinguisher Dry Chemical Powder(Abc) Stored Pressure Type 6Kg As Per Is:15683 With Isi Mark And With Initial Charger And Installation Brackets. , Od539354/2024-2025:Painting Letters Or Figures Of The Following Sizes With Enamel Paint As Identification Mark To Sb, Db, Panel Board Etc As Required. 2.5Cm, 4Cm,5Cm Height