Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 23-09-2025 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 30-09-2025 |
| 2 | 15-09-2025 | Revised BOQ | BOQ | 23-09-2025 |
| Sl. No. | Item Description |
| 1 | Taking down carefully Aluminium/ copper point wiring complete for light, fan, 5A/15A switches socket, 2 way points and bell point etc and also taking down boards with screw, holders, fixture and fittings such as switches, ceiling roses, lamp holder, bulk head fittings, tube light fittings regulators, sockets, light fitting, brackets, etc. any type of electrical fittings etc complete & making good to disturbed area, complete all as specified and directed by Engineer in Charge. |
| 2 | M&L for Concealed Point wiring complete with 1.5 Sq mm single core multi-stranded cables copper conductor PVC insulated and unsheathed cable 1100 volt grade drawn through and including non metallic rigid PVC conduit, medium grade minimum 25mm dia ISI marked and conduit accessories fixed concealed in wall/ ceiling/ roof etc with sunken type pressed steel/ welded MS terminal boxes made out of 1.6mm MS sheet, 3mm thick laminated sheath top cover for mounting of fittings switches, sockets outlets, regulators etc complete including provisioning of 1.5 sqmm PVC insulated unsheathed cable 1100 volt grade with mult stranded copper conductor to common earth and connected to earth dolly for the following, complete all as specified and directed by Engineer in Charge. |
| 3 | (a) All as above item No. 2 one light point, ceiling fan/Exhaust fan point controlled by one switch 6Amp, one way, complete all as specified and directed by Engineer in Charge. |
| 4 | (b) All as item No.2 above but Bell point controlled by one switch 6Amp one way, complete all as specified and directed by Engineer in Charge. |
| 5 | (c) All as item No.2 above but one 3 pin Socket 5/6 Amp on the same board, complete all as specified and directed by Engineer in Charge. |
| 6 | (d) All as item No.2 above but one 3 pin Socket 5/6 Amp on the independent board, complete all as specified and directed by Engineer in Charge. |
| 7 | All as per Srl No. 2 above here-in-before but point wiring with 2.5 Sqmm single core multi stranded copper conductor PVC insulated & unsheathed cable 1100 volt grade and 1.5 sqmm PVC insulated & unsheathed cable 1100 volt grade with multi stranded copper conductor for earth wire for 15/16 Amp multi purpose socket combination point on independent board, complete all as specified and directed by Engineer in Charge. |
| 8 | Dismantling/ Taking down existing unserviceable sub main wiring of size 4/6 Sqmm from batten/ conduit of any size all as directed, Removing the material from work site and making good the disturbed portion/ surface of wall/ floor/ ceiling etc by using cement mortar and colour/ white wash to match with the existing surface/ location, complete all as specified and directed by Engineer in Charge. |
| 9 | M&L for sub main surface wiring with PVC insulated unsheathed copper conductor cable FRLS of size 6 Sqmm single core through concealed rigid non-metallicPVC conduit of suitable size (Not less than25mm dia)inwall and surface of ceiling including 6 Sqmm PVC insulated unsheathed copper conductor cable for continuous earthing form main earth dolly includingmakinggoodthedisturbedpotionofwall, complete all as specified and directed by Engineer in Charge.Note:- Two run of 6 Sqmm copper cable one run of 6 Sqmm copper cable and PVC conduit will be measured as a single length. |
| 10 | M&L for sub main surface wiring with PVC insulated unsheathed copper conductor cable FRLS of size 4 Sqmm single core through concealed rigid non-metallicPVC conduit of suitable size (Not less than25 mm dia)inwall and surface of ceiling including 4 Sqmm PVC insulated unsheathed copper conductor cable for continuous earthing form main earth dolly includingmakinggoodof thedisturbedpotionofwall, complete all as specified and directed by Engineer in Charge.Note:- Two run of 4 Sqmm copper cable one run of 4 Sqmm copper cable and PVC conduit will be measured as a single length. |
| 11 | S&F in repairs modular switch piano flush type single pole 1 way 6 Amps 230 volts, AC one way, complete all as specified and directed by Engineer in Charge. |
| 12 | S&F in repair modular switch piano type 16 Amps flush button 230 volts AC one way, complete all as specified and directed by Engineer in Charge. |
| 13 | S&F in repair modular socket outlet 6 Amps 2/3 pin combined flush type multipurpose 2 module, complete all as specified and directed by Engineer in Charge. |
| 14 | S&F in repair modular socket outlet 6/16 Amps 2/3 pin combined flush type multipurpose 2 module, complete all as specified and directed by Engineer in Charge. |
| 15 | S&F in repair modular bell push flush type 230 volts 6Amps, 1 module, complete all as specified and directed by Engineer in Charge. |
| 16 | S&F in repair modular fan regulator electronic step type 2 module suitable for 1200/1400 mm sweep ceiling fan, complete all as specified and directed by Engineer in Charge. |
| 17 | S&F in replacement Celling fan 1200 mm sweep 3 blade energy saving 5 star rating including taking down existing un serviceable ceiling fan from the location and setting asidefor fixing/ depositing to MES E/M store yard, complete all as specified and directed by Engineer in Charge. |
| 18 | S&F in replacement exhaust fan, 250/300 mm sweep,230 Volts, single phase, with necessary grouting and fixing arrangements and provision of 3 core flexible copper conductor cable of size 1.5sqmm size from ceiling rose to connector of exhaust fan, complete all as specified and directed by Engineer in Charge. |
| 19 | S&F in repairs ceiling rose surface Bakelite 2/3mm terminal 65x50mm, suitable for 230 volts AC supply, complete all as specified and directed by Engineer in Charge. |
| 20 | S&F in repairs call bell, ding dong, 230 volts AC supply, complete all as specified and directed by Engineer in Charge. |
| 21 | S&F LED bed side light 2 watts grey/metal synthetic incl connection with suitable size copper wire & fixing the fitting on suitable size PVC/ wooden round block on wall, complete all as specified and directed by Engineer in Charge. |
| 22 | S&F in replacement Tube light fittings LED type 1x20 Watt4 ft long incl LED tube rod and incl 3 core flexible wire 0.75 Sqmm copper cable, complete all as specified and directed by Engineer in Charge. |
| 23 | S&F in replacement Tube light fittings LED type 1X10 Watt, 2 ft long incl LED tube rod and incl 3 core flexible wire 0.75 Sqmm copper cable, complete all as specified and directed by Engineer in Charge. |
| 24 | S&F in repairs LED bulk head luminaire with opal diffuser 10 watts 6000K IP 65 protection incl suitable size PVC/ sunmica wooden board of suitable size &white twin core flexible wire from celling rose to fitting, complete all as specified and directed by Engineer in Charge. |
| 25 | S&F Lamp holder, PVC/ Polycarbonate type with back plate suitable for batten fittings, complete all as specified and directed by Engineer in Charge. |
| 26 | S&F in repairs 12 watt LED bulb with base cap type, complete all as specified and directed by Engineer in Charge. |
| 27 | S&F LED street light fitting 60 Watt 230 V AC outdoor type 5700 K with high pressure die cast aluminium hosing along with prismatic polycarbonate modular secondary lens optics with IP 66ingress protection. 4KV in-built and 10 KV external surge protection with top opening driver cover for easy maintenance with efficacy not less than 120 lm/W heat resistant. The LED driver shall be of isolated type with Constant Current Constant Voltage topology to ensure optimum driving of LEDs. The LED streetlight shall have power factor more than 0.95. The optical compartment shall be covered with heat resistant toughened glass for safety. The LED Street light should be top maintainable for easy maintenance LED street light shall be of Integral type complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics, complete all as specified and directed by Engineer in Charge.Note :-(i)Driver and luminaire of LED fitting shall be of same manufacturer(ii) All T&P ie ladder, Tools, Safty glooves etc will be provided by the contractor without any extra costto height upto 25 mtr. (iii) If same capacity is not available next higher capacity shall be provided by the contractor without any extra cost. |
| 28 | M&L for down rods for ceiling fan, 0.9 m long, GI pipe of suitable size dulythreaded for check nut and holes drilled for spilt pin including mild steel bolts and nuts, double washers and rubber reel bush suitable for ceiling fans of 1200 mm sweep fixed in repairs, complete all as specified and directed by Engineer in Charge. |
| 29 | M&L for Rewinding of ceiling fan/exhaust fan motor of any size after disconnecting from roof without damage shifting to work shop, dismantling the motor assembly and removing the burnt out copper winding, rewinding the same itemswith suitable gauge super enamelled copper wire with insulating papers and insulation cloths, varnishing the winding along with 2.5/4 MFD capacitor and baking heatingfor achieving the required insulation resistance, re-assembling the motor and testing complete, incl transporting back to siteand fixing fan/exhaust motor to its original place, reconnecting electric cable etc testing and commissioning, complete all as specified and directed by Engineer in Charge. |
| 30 | S&F in repairs Capacitor 2.5 MFD, complete all as specified and directed by Engineer in Charge. |
| 31 | S&F in repairs Capacitor 4 MFD, complete all as specified and directed by Engineer in Charge. |
| 32 | S&F in repairs Sheet metal enclosure factory made of size 20CMx25CMx12.5CM deep box made out of 2mm thick MS sheet with double door with locking arrangement, epoxy powder coated holes drilled for cable entries suitable for accommodating electric energy meter including brick/ cement works as per site requirement including flushing the box in wall and making good the disturbed portion of wall/surface, complete all as specified and directed by Engineer in Charge. |
| 33 | S&F in repairs single pole and neutral enclosure, powder coated, with a two pin earth plug and socket complete, 20 Amps, 240V, including provision of one single pole MCB 20 Amps \"C\" curve type including taking down existing unserviceable enclosures, complete all as specified and directed by Engineer in Charge. |
| 34 | S&F in repairs including flushing in wall MCB DB vertical TPN 4 way, 415 volts AC double door type sheet metal phosphatised powder painted with bus bar neutral earth bar and including provision of MCB TPN, FP 100 Amp conforming to IP 43 as incomer, complete all as specified and directed by Engineer in Charge. |
| 35 | S&F in repairs single pole and neutral (SPN) 8 way MCB distribution box double door powder coated sheet metal enclose 240 volts including 200 Amps rated bus bar, complete all as specified and directed by Engineer in Charge. |
| 36 | S&F in repairs single pole and neutral (SPN) 4 way MCB distribution box double door powder coated sheet metal enclose 240 volts including 200 Amps rated bus bar, complete all as specified and directed by Engineer in Charge. |
| 37 | S&F in repairs or replacement of MCCB 100A, 4 pole, 415 volts with breaking capacity of 16 KA, complete all as specified and directed by Engineer in Charge. |
| 38 | S&F in repairs or replacement of MCB SP 240 volts of capacity 6 to 32 Amps \"C\" series, reputing capacity 10 KA, complete all as specified and directed by Engineer in Charge. |
| 39 | S&F in repairs or replacement of MCB SPN 240 volts of capacity 32/40 Amps \"C\" series, reputing capacity 10 KA, complete all as specified and directed by Engineer in Charge. |
| 40 | M&L for Earthing complete with GI earth plates electrode 600x600x6mm thick buried directly in ground earth pit not less than 2.25 mtr deep below ground level surrounded with adequate quantity of charcoal dust mixed with salts to a packet thickness of 15 cm all around the plate, using GI earth strip 32x6mm connected to earth plate by means of nut, bolts and washers as directed GI pipe light grade 50mm bore on water pipe from earth chamber to copper edge of earth plate, CI funnel with wire mesh fixed on water pipe and PCC 1:2:4 type B-1 using 20mm graded stone aggregate as in pit chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type B-1 dully reinforced with MS bars 6mm dia @150 c/c both ways with 10mm dia MS bar in lifting handle excavation earth work including laying of GI pipe in walls etcall as directed in electrical plateNo 3 ofSSR Part-I, complete all as specified and directed by Engineer in Charge. |
| 41 | S&F in replacement of storage type electric water heaters (vertical geysers) of 25 litres capacity, 5 star rating, 2000 Wattfixed to wall with suitable bolts and nuts duly grouted including re-connecting the electrical and water supply connection including taking down of Geyser, complete all as specified and directed by Engineer in Charge. |
| 42 | S&F in replacement of heating element,240 volt AC ISI marked of 1500 watts Circular/ triangular shape rating as required at site including rubber washers, complete all as specified and directed by Engineer in Charge. |
| 43 | Supply and replace thermostat switch suitable for 25/35/50 litre geyser AC 230 volt adjustable range from 0-90 degree Celsius, complete all as specified and directed by Engineer in Charge. |
| 44 | S&F in replacement of multifunction safety valve i.e.. Pressure release, non return, drain, expansion, vacuum release valve. of size 15mm dia, for geysers of 25/50 litre, screwed with both ends, complete all as specified and directed by Engineer in Charge. |
| 45 | S&F in repairs indicator lamp square/ round/ rectangular type, green/ red, suitable for geysers, 25 litres capacity, complete all as specified and directed by Engineer in Charge. |
| 46 | M&L for PVC insulated and sheathedflexible multistranded copper conductor cable, 3 core x 4 sqmm size, 1100 volts grade, fixed in repairs, complete all as specified and directed by Engineer in Charge. |
| 47 | S&F in replacement of unserviceable PVC connection, ISI marked, 15 mm dia 600mm long with brass nuts suitable for hot/ cold water supply, complete all as specified and directed by Engineer in Charge. |
| 48 | S&F in replacement of existing unserviceable PVC connection, ISI marked, 15 mm dia 450mm long with brass nuts suitable for hot/ cold water supply, complete all as specified and directed by Engineer in Charge. |
| 49 | S&F for mild steel fastener bolts, nuts and washers, full threaded, dia of neck 05 to 10mm, length not exceeding 100mm, complete all as specified and directed by Engineer in Charge. |
| 50 | S&F in repairs stop valves, cast copper alloy, screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions, 15 mm bore, complete all as specified and directed by Engineer in Charge. |
| 51 | Dismantling/taking down and M&L for servicing and repairs ofWindow/split AC 1.5/2 Ton capacity for servicing complete, cleaning of evaporator coil, condenser, blower, base tray, drain hole, replacement of polypropylene pad, oiling of fan motor, checking of wiring connections, terminals capacitor, relay selector switches, drainage, rubber bushes bearing bushes etc and re-fixing the same in position and testing complete in full load, complete all as specified and directed by Engineer in Charge.Note : Split AC are installed at various floors in AF stn Abohar ie Ground floor to 3rd floor.Contractor shall arrange his own arrangement to access the repairs for split units. No tools and plants shall be supplied to the contractor from the department. |
| 52 | S&F running capacitor 40/45/50/55/60 MFD suitable for 1.5/2.0 Ton capacity of window type AC fixed in replacement, complete all as specified and directed by Engineer in Charge. |
| 53 | S&F in replacement fan blade for window/split AC of 1.5/2.0 Ton, ISI Mark or as per existing make and model, complete all as specified and directed by Engineer in Charge. |
| 54 | S&F in repair of blower motor single phase 230 volts, 50 Hz, 0.5 HP, 900 RPM suitable for window type AC of capacity 1.5/2.0 TR fixed in replacement, complete all as specified and directed by Engineer in Charge. |
| 55 | S&F condensing coil (copper coil) assembly complete suitable for window type/spilt type AC of capacity 1.5/2.0 TR etc complete and recharging the refrigerant R-22 and testing fixed in replacement, complete all as specified and directed by Engineer in Charge. |
| 56 | M&L for cleaning the gas system with anti corrosive solution and recharging the refrigerant R-22/ R-134a /R-410/ R-407 with anti moisture substance and replacement of filter along with rectification of leakage system in the window type AC/split type AC of capacity 1.5/2.0 Ton including installation at site and testing on full load, complete all as specified and directed by Engineer in Charge. |
| 57 | M&L for rewinding of blower motor of window type/split type AC 1.5 Ton capacity single phase 1/5HP, 900 RPM with super enamelled copper wire of existing gauge including replacement of bush and nut and bolts, washer etc, complete all as specified and directed by Engineer in Charge. |
| 58 | Taking down/dismantling of old unserviceable defective Rotary compressor of capacity 2/1.5 TR of split type/ window AC and replacement in new rotary compressor of cap 2/1.5 TR by soldering/ brazing of copper tube and replacement of foundation pads including nut &bolt and washers as required and charging with refrigerant R-22/ R-134A/ R-410 to its rated capacity and testing of leakage in the system if any and making good, testing on full load after reinstalling the same, complete all as specified and directed by Engineer in Charge. |
| 59 | Taking down unserviceable & S&F thermostat suitable for split/window AC refrigerator any capacity, complete all as specified and directed by Engineer in Charge. |
| 60 | S&F in replacement Oscillation motor with swing blade strip for indoor unit of split AC 1.5/2. TR capacity same specification/ make as per existing one, complete all as specified and directed by Engineer in Charge. |
| 61 | Supply in replacement of copper pipe line of size 1/4\" to 1/2\" for split/window type AC of any capacity, complete all as specified and directed by Engineer in Charge. |
| 62 | Supply in replacement of copper pipe line of size 3/8\" to 5/8\" for split/ window type AC of any capacity, complete all as specified and directed by Engineer in Charge. |
| 63 | Taking down unserviceable brass suction valve & supply & fix new brass discharge valve 3/8\" suitable for cassette/ split type, complete all as specified and directed by Engineer in Charge. |
| 64 | Taking down unserviceable brass discharge valve & supply & fix new brass discharge valve 3/8\" suitable for cassette/ split type, complete all as specified and directed by Engineer in Charge. |
| 65 | S&F in replacement of Brass flair nuts 1/2\" to 1/4\" for split/window type AC of any capacity, complete all as specified and directed by Engineer in Charge. |
| 66 | S&F in repairs fan motor for Outdoor unit of same specification as per existing one suitable for split type AC of capacity 1.5 Ton fixed in replacement, complete all as specified and directed by Engineer in Charge. |
| 67 | S&F in repairs indoor blower motor for split type AC as per existing one suitable for split type AC of capacity 1.5 Ton fixed in replacement, complete all as specified and directed by Engineer in Charge. |
| 68 | S&F in replacement of existing unserviceable/burnt with new PCB of invertor type split/window AC of 1.5/2.0 TR of same make by replacement its unsv parts make it fully functional and refixing the same on existing location, complete all as specified and directed by Engineer in Charge. |
| 69 | S&F in replacement of refrigerator double door, capacity 322 Litres, 3 star rated, electric driven single phase, 240 volt, 50 Hz, frost free smart inverter, complete all as specified and directed by Engineer in Charge. |
| 70 | Attending day to day complaint of detecting the fault in Refrigerator/ water cooler/ window AC/ split/ desert cooler/ voltage stabilizer/ electric supply in all eqpt like loose nut and bolts, leakage of tube, checking electrical connections, charging of refrigerant, fan motor, compressor, fault etc, complete all as specified and directed by Engineer in Charge.Note:- (a)Any defective part which are required to be replaced to make functional ACs shall be measured and paid separately.(b)The contractor should attend the complaint and rectify the defect within 2 days (Maximum), If contractor fail to rectify the complaint within 2 days, recovery shall be made from contractor @ Rs 500/- per day per AC (split/window 1.5/2.0TR) water cooler, refrigerator complaint from the RAR |
| 71 | S&F in replacement Blower drum assembly complete for split AC 1.5/2.0TR as per existing, complete all as specified and directed by Engineer in Charge. |
| 72 | M&L for complete maintenance and repairs of refrigerator of capacity 165 to 310 litres including servicing cleaning of refrigerator internal portion checking of compressor, condenser and replacement of overload relay, thermostat, capacitor, wiring, veg tray, chiller tray, strainer, freezer door and timer etc and testing, complete all as specified and directed by Engineer in Charge.Notes:-(i)Rates includes servicing of unit for one time and will be considered as one job. (ii)Rates are including for Spares required for replacement which is mentioned in servicing.(iii)Servicing shall be carried out in the presence of Engr-in-Charge or his representative necessary service report (complaint slip) is to be signed by the rep. of AGE E/M.(iv)Old spare parts retrieved after replacement will be the property of the contractor under schedule of credit and shall be removed by the contractor outside at his own cost. \" |
| 73 | Dismantling of defective compressor sealed unit of refrigerator from existing refrigerator by removing suction/ discharge line and providing new approved factory sealedcompressor of equal capacity given below (company re-oriented) flushing complete system with nitrogen gas pressure testing for leakages, vaccumisation of complete system and gas charging with F- 134/ R22/ 407A including connection suction/ discharge line 165 to 310 Ltrs capacity refrigerator ISI Mark or as per existing make and model, complete all as specified and directed by Engineer in Charge. |
| 74 | S&F in repair Thermostat switch with defrosting system suitable for refrigerator of capacity 165 to310 Ltrs, complete all as specified and directed by Engineer in Charge. |
| 75 | Dismantling of defective compressor sealed unit of water cooler from existing foundation by removing suction/ discharge line and providing new approved compressor of equal capacity given below (company re-oriented) flushing complete system with nitrogen gas pressure testing for leakages, vaccumisation of complete system and gas charging with F- 134, R22 or as existing including connection suction/ discharge line complete 40/80/60 Ltrs capacity water cooler, complete all as specified and directed by Engineer in Charge. |
| 76 | Taking down unserviceable starting relay and supply and fix starting relay for water cooler cap 40/ 80/60/ 120/ 150 ltrs, complete all as specified and directed by Engineer in Charge. |
| 77 | Taking down unserviceable push cock & supply and fix new push cock 15mm dia of brass chromium plated suitable for water cooler, complete all as specified and directed by Engineer in Charge. |
| 78 | Taking down carefully desert coolers from various buildings and floors (viz. ground floor, first floor, second floor and third floor) at AF Station, Abohar for repair and refixing after completion of necessary repairs, complete all as specified and directed by Engineer in Charge.Note:-(a) Contractor shall make his own arrangements to access various floors and to provide tools and plants for taking down and refixing of desert cooler.(b) The rate quoted shall be deemed to include all these arrangements all as required at site. |
| 79 | Dismantling of unserviceable wood wool pad and providing not less than 2.5 kg adequate dense newwood wool pad 03 Nos supported with suitable size GI wire & bamboo/ wood stick for supporting of wool pad inside complete includingfitted with bolts and nuts suitable for existingdesert cooler, complete all as specified and directed by Engineer in Charge. |
| 80 | M&L for Preparation of old painted surface and applying DUCCO paint by spray gun fully matched with its existing colour outside and two coat of black bituminous paint inside the water cooler base/ compressor compartment including removal of all dust and all foreign material with the help of sand paper and rubbing with cleaning compound and polishing on painted surface etc, complete all as specified and directed by Engineer in Charge. |
| 81 | Taking out of unserviceable transparent flexible PVC pipe of 15 mm dia and providing new PVCtransparentflexible pipe of 15 dia, 03 branch minimum length 0.8 mtr long including clamp and of same quality for water circulation pump to air cooler, complete all as specified and directed by Engineer in Charge. |
| 82 | Dismantling of unserviceable submersible water circulation pump assembly and providing of new submersible electric driven single phase 230 volts, 50 hz 20 watt water circulation pump, nut bolts, clamp, of head minimum1.6 Mtrfor desert cooler, complete all as specified and directed by Engineer in Charge. |
| 83 | M&L for rewinding of exhaust fan motor of desert cooler of size / capacity 4500 CFM Exhaust 1/6 HP 1250 rpm including replacement of nut bolts, clamps, complete all as specified and directed by Engineer in Charge.Note:- The cost shal be included taking down and re-fixing in existing location including clamp nut bolts etc. |
| 84 | Dismantling of unserviceable fan bladeand providing of new fan blade made out of aluminium casting suitable for existing desert cooler, complete all as specified and directed by Engineer in Charge. |
| 85 | Taking down unserviceable capacitor 4 MFD and S&F new capacitor 4 MFD, 220 Volts, complete all as specified and directed by Engineer in Charge. |
| 86 | S&F control piano switch, flush type, 5 Amps suitable for existing desert cooler including taking down the old unserviceable switch, complete all as specified and directed by Engineer in Charge. |
| 87 | S&F plug top, 3 pin, 5 Amps including taking down the old unserviceable plug top, complete all as specified and directed by Engineer in Charge. |
| 88 | S&F water tray of size 95 cm x 75 cm and height 20 cm, made of GI sheet 0.63 mm thick suitable for desert cooler including taking out old unserviceable tray, complete all as specified and directed by Engineer in Charge. |
| 89 | Taking down U/s desert cooler and supply, installation, testing, commissioning of desert cooler of capacity 4500 Cum per hour made out of 01 mm thick galvanised steel sheet with complete fully exhaust fan 450 mm sweep, 1400 rpm motorand suitablecapacity submersible pump and wood wool fitted in frame made from 25x25x3 mm angle iron and 25x25 mm size MS wire mesh net of 14swg dia fitted on both sides for supporting woodwool including suitable size top and bottom water tray made of 1.00 mm GIsheet 1000 watts speed control electronic regulator, suitable size connection cable 3 core with copper conductor with moulded plug top, fan blade and all fixingaccessories, complete all as specified and directed by Engineer in Charge. |
| 90 | Supply only refrigerant gas R-22/32 or existing gas, complete all as specified and directed by Engineer in Charge. |
| 91 | Supply only refrigerant gas R-410, complete all as specified and directed by Engineer in Charge. |
| 92 | Supply only refrigerant gas R-134A, complete all as specified and directed by Engineer in Charge. |
| 93 | M&L for block GI pipe upto 25mm from solar water heater (Top roof ) to ground floor bldge and cleaning with anti corrosive solution and pipe block rectification will be done in presence of JE (E/M)/AGE E/M, complete all as specified and directed by Engineer in Charge. |
| 94 | S&F in repair and replacement of voltage stabilizer electronic& digital suitable for single phase voltage working range 130-270 volts 50Hz AC supply with low voltage high voltage cut off & time delay arrangement of capacity 5 KVA, complete all as specified and directed by Engineer in Charge. |
| 95 | Taking down electric motor 5.0 HP, 415 volt, 50Hz coupled to pump after disconnecting theelectrical connection, and earth connections from its foundation and transportation to work shop , checking the serviceability of ball bearing both side of motor, greasing of bearing up to free rotation of shaft of motorcomplete, greasing on re-assembling the motor to re-installation on foundation, reconnecting back the cable and earth connections etc complete in all respect and starting the pump, complete all as specified and directed by Engineer in Charge. |
| 96 | M&L forReplacement ofU/S ball/ roller bearing of above motor bearing of existing makewith providing of high grade grease, complete all as specified and directed by Engineer in Charge. |
| 97 | M&L for opening pump set split case monoblock /Centrifugal pump type coupled to electric motor of capacity 5.0 HP, 415V, 50Hz from motor coupling after isolating the electric and earth lead connections opening the pump set for repair/ overhauling & proper alignment of shaft etc including replacing U/S items with new items given vide item 94 below but excluding replacement of minor parts like key for main shaft, check nut, water seal if reqd as the cost deemed to be included in quoted rate.Re-assembling the pump setgreasing, connecting, testing and commissioning complete including necessary Lathe works, complete all as specified and directed by Engineer in Charge. |
| 98 | Supply only spare parts for as above Item No 93 for replacing vide item above as follows:- |
| 99 | a) Supply only pump shaft sleeve made out of gun metal |
| 100 | b) Supply only pump Shaft |
| 101 | c) Supply ball/roller bearing complete |
| 102 | d) Impeller Cast iron |
| 103 | M&L for Rewinding of pump with motor of 5.0 HP, 415 Volt 3 phase, 50Hz after disconnecting electric cable and earth lead, suction and delivery pipes, from 09 mtre depth of sewage well or pump house or any location directed by JE E/M shifting to work shop, dismantling the motor assembly and removing the burnt out copper winding of motor and Rotar cleaning the motor slots and core assembly, rewinding to stator and rotar with suitable gauge super enamelled copper wire with insulating papers and insulation cloths, varnishing the winding and baking heatingfor achieving the required insulation resistance, re-assembling the motor and testing complete, incl transporting back to siteand fixing motor to its original place, reconnecting electric cable and earth leads etc testing and commissioning, complete all as specified and directed by Engineer in Charge for the Item No 95.1 to 95.2. |
| 104 | (a) 1 to 3 HP |
| 105 | (b) 4 to 5.5 HP |
| 106 | Taking up and down U/S of GI tubing existing pipe with all fittings of size 20,25,40 & 50mm bore, complete all as specified and directed by Engineer in Charge. |
| 107 | M&L of GI water tubing of size 50 mm bore medium grade ISI marked with all required fittings such as bends elbows, tees short pieces, connector check nuts& threading fixed complete to walls and ceilings or laid in floors/ trenches, complete all as specified and directed by Engineer in Charge. |
| 108 | All as described in item No. 97 but 40 mm bore GI tubes. |
| 109 | All as described in item No. 97 but 25 mm bore GI tubes. |
| 110 | All as described in item No. 97 but 20 mm bore GI tubes. |
| 111 | S&F in repair/replacement of Gun metal gate valves, cast copper alloy, butterfly handle, screwed both ends with iron pipe of size 25 mm dia/bore valve, complete all as specified and directed by Engineer in Charge. |
| 112 | All as described item Ser No. 98 but size of 40 mm dia/bore GM gate valve. |
| 113 | All as described item Ser No. 98 but size of 50 mm dia/bore GM gate valve |
| 114 | All as described item Ser No. 98 but size of 20 mm dia/bore GM gate valve |
| 115 | Taking up and down U/S of DI existing pipe with all fittings of size 80mm bore, complete all as specified and directed by Engineer in Charge. |
| 116 | Supply and Laying of Ductile Iron Pressure pipes with socketed & spigot ends centrifugally, class K-7 of size 80 mm bore conforming to IS: 8329/2000 marked suitable for Push -on -jointing in any length laid in trenches with including all fittings, complete all as specified and directed by Engineer in Charge. |
| 117 | Water testing for 44WEU(A) Abohar of water quality testing certificate for environmental health and safety research and development centre & Govt approved lab, complete all as specified and directed by Engineer in Charge. |
| 118 | S&Fin repair of CI body Sluice valve PN 1.6 conforming to ISof size 80 dia complete with nuts, bolts,rubber gaskets etc including, including jointing material such as rubber gasket, bolts, nuts, etc suitable for size 80 mm, complete all as specified and directed by Engineer in Charge. |
| 119 | S&Fin repair of CI body Sluice valve PN 1.6 conforming to ISof size 150 dia complete with nuts, bolts, rubber gaskets etc including, including jointing material such as rubber gasket, bolts, nuts, etc suitable for size 150 mm, complete all as specified and directed by Engineer in Charge. |
| 120 | S&F in repair of CI body NRV valveconforming to ISof size 80 dia complete with nuts, bolts, rubber gaskets etc including jointing material such as rubber gasket, bolts, nuts, etc suitable for size, complete all as specified and directed by Engineer in Charge. |
| 121 | S&F in repairs 80 mm bore foot valve, nitrite ball type, cast iron body, flanged type, conforming to relevant IS 4038 with rubber gaskets, MS nuts, bolts, washers, etc, as required and testing complete including taking down the existing unserviceable foot valve of any description, complete all as specified and directed by Engineer in Charge. |
| 122 | M&L for painting of Monoblock/ Centrifugal pumpswith motor along with 10 mtr pipe suction/ delivery of capacity 5.5 HP with two coats of synthetic enamel Paint, complete all as specified and directed by Engineer in Charge. |
| 123 | M&L for cleaning ofRCC Under ground tank reservoir up to 25000 gallon capacity by drain out the contaminated muddy water from bottom surfaces of the tank by using of pump and motor and cleaning the inside and bottom surfaces of walls with help of wire brush and using specified dosage of Potassium permanganate and cleaned water than drain out completely material to the entire satisfaction of Engr in Charge with and including writting letters 5 CM height capacity of Tank and date of Cleaning of tank, with synthetic enamel paint on the other surface of the tank, complete all as specified and directed by Engineer in Charge.Note: date & time will be decided by Engr-in-charge for cleaning of UG Tank |
| 124 | M&L for cleaning of overhead water reservoir 60000 gallon capacity on 25 metre staging bycleaning entire internal surface by removing dirt, sludge etc with wire brush by applying bleaching power and fresh water and clean entire surface repeatedly with fresh water and draining out soiled water includingLime washing inside the tank the capacity of sump and date of cleaning with white paint over black painted surface be written with 5CM height letter, complete all as specified and directed by Engineer in Charge.Note: date & time will be decided by Engr-in-charge for cleaning of UG Tank |
| 125 | M&L for run lead joints in repair for 80mm dia spigot and socketed CI pipe fittings including spun yarn etc, complete all as specified and directed by Engineer in Charge. |
| 126 | M&L for XLPEinsulated, armoured, heavy duty electric LT UG cable with multi-stranded aluminium conductor,1100 Volts grade, cross sectional area 16Sqmm x 4 core, laid in trenches/ passing through pipe/ duct or fixed to wall including provision of necessary lugs/ thimbles/ ferrules, connecting up, testing and commissioningcomplete including taking down existing unserviceable LT UG cables of any description and size and making good disturbed surfaces, complete all as specified and directed by Engineer in Charge.Note: Excavation, earth work,riddled earth cushioning, bricks/ GI pipe for protection shall be measured and paid separately under relevant items of this schedule. |
| 127 | Excavation in trenches not exceeding 1.5 Mtr wide and not exceeding 1.5 Mtr in deep for foundation of poles/stays/cables/ Pipe lines etc and getting out in soft/loose soil, complete all as specified and directed by Engineer in Charge. |
| 128 | Returning, filling in including spreading, leveling, watering and well ramming in layers each not exceeding 25 cm thickness, complete all as specified and directed by Engineer in Charge. |
| 129 | Removing surplus soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point, complete all as specified and directed by Engineer in Charge. |
| 130 | S&F Double wall corrugated high density polymer ethyl pipe of size 50mm outer diawith ISI marked (IS 14930- 2001), laid in trenches /floors & fixed on wall/ pole with & including necessary fittings such as bends, sockets & other connected accessories etc forlaying of electric cables, complete all as specified and directed by Engineer in Charge. |
| 131 | M&L for cuttingof road/ hard standing up to a size exceeding 0.45 cm widthand not exceeding 90cm in depth for laying ofpipe lines/ cable protection pipe including making good the disturbed road/hard standing/path etc with same specification to match the existing surface level, complete all as specified and directed by Engineer in Charge. |
| 132 | M&L transformer oil, low viscosity insulating oil for top up transformer of as per IS-335, complete all as specified and directed by Engineer in Charge.Note - The oil shall be supplied in sealed barrel only. |
| 133 | M&L for testing the dielectric strength of transformer oil of the transformers installed at various sub stn at/on floor/pole before dehydration and dehydrating and filtering the transformer oil with dehydration machine to achieve dielectric strength of the oil up to 50 KV at 2.5 mm gap as per IS standard, complete all as specified and directed by Engineer in Charge.Note : The transformer dehydration machine and dielectric strength testingmachine shall be arranged/ brought by contractor at site and no extra cost shall be paid to the contractor. |
| 134 | M&L in replacement of breather including deep sky blue colour silica gel capacity of 1.5Kg. Breathing assembly should be fasted at 0.35 kg/cm2 for 30 minutes and silica gel change of color blue to pink and absorption capacity of moisture 27% by his weight minimum, complete all as specified and directed by Engineer in Charge. |
| 135 | M&L for preparing old painted surface of transformer of outdoor/ indoor type of capacity 63 KVA to 200 KVA by cleaning dirt, oil, grease etc. removing the old paint, rust by scratching with wire brush/ emery paper etc, after disconnecting HT/LT electric connection from both primary and secondary side of transformer and apply two coat of synthetic enamel spray paint of existing colour on out side body of the transformer and writing of letter HT/LT and SM MES No etc. of 10 cm height and making all HT/LT electric connections and testing the same, complete all as specified and directed by Engineer in Charge.Note:-(a) The compressor and spray machine etc. shall be arranged/ brought by contractor at site and no extra cost shall be paid to the contractor. (b) Volt meter, Ammeter, relays etc. on panel / Transformer should be covered properly at the time of painting and after painting if any damage to the existing display or any item then the same will be replaced by contractor without any extra cost. |
| 136 | Disconnecting HT/LT connection of transformer capacity 200KVA, opening top cover, removing transformer oil, cleaning all parts like barrel, out side & inside chamber body, tap changer, breaker assy, explosive tube etc with emery paper and removing the transformer to approved workshop and rewinding the transformer, filling of transformer oil, reassembling the transformer on existing platform.Reconnection of LT/HT connection after proper dehydration , reconditioning and testing of transformer after reassembling complete on no load at work shop and on load testing at site, complete all as specified and directed by Engineer in Charge.Note:- (i) Gasket set, nuts and bolts, washers etc are included cost of above job (ii) After refixing of transformer, testing of transformer will be based on partial load and full load, incl entire painting of transformer with super enamelled paint, deemed in quoted rates by contractor (iii) Unsv transformer should be rewinding in workshop within a week time frame on reaching at the work shop, after failing a penalty will be imposed to contractor as per IAFW-2249 of contract agreements (iv) transportation of transformer upto workshop and back to site will be complete responsibility to the contractor, and no other charges will be paid to contractor for transportation (v) Dehydration and filtration of transformer deemed in quoted rates.(vi) Rewinding of transformer copper wire will be measured and paid separately. (vii)LT/HT bushes of transformer will be measured and paid separately. (viii)For uploading of transformer at workshop and unloading of transformer at AF Stn, Abohar, Yard with required manpower and T&P rates are included in above item. (ix)For transportation of transformer from workshop and insurance oftransformer rates are included in above items. (x) Contractor is fully responsible of any accident happens during works and no any extra payment will be paid by department. |
| 137 | S&F in replacementHV bushing with rod incl all accessories suitable for transformer of capacity 200 KVA with copper strip along with suitable gasket, complete all as specified and directed by Engineer in Charge. |
| 138 | S&F in replacement of LV bushing with rod incl all accessories, suitable for transformer of capacity 200 KVA with copper strip along with suitable gasket, complete all as specified and directed by Engineer in Charge. |
| 139 | M&L for replacement of winding of transformer/ voltage stabilizer with appropriate gauge super enamelled copper wire for transformer/voltage stabilizer 200 KVA, 11 KV, 3 phase, complete all as specified and directed by Engineer in Charge.Note: Guarantee of Winding of transformer will be one year from repairing date. |
| 140 | M&L for servicing of DG set 20 KVA to 62.5 KVA by draining out engine oil, removing oil filter, replace with new one and refill the engine oil, clean fuel feed pump, replace primary and secondary fuel filter along with Redi-wash \"O\"-Ring, replace paper type air filter and safety cartridge, replace air cleaner oil bath type, check alignment of exhaust system, check belt tension and tighten or loosen belt tension as per requirement, blow compressed air with the help of blower on radiator fan to clean it and descaling the radiator internally and externally by using chemical, including soldering the copper tubes and tank etc for arresting leakage, check all the clips and tighten if required, clean battery terminals with cotton cloth, apply acid proof grease or petroleum jelly on battery terminals, check electrolyte level of battery and top up distilled water if electrolyte level is low, check electrical connection of starter and tighten if required check belt tension on charging alternator and adjust if required. Check output voltage of charging alternator. Tighten all the foundation nuts and bolts if required, check LLOP and HWT with multimeter, check stopper and adjust tightness of link wire if required, check tightness of wiring connection and adjust accordingly, remove RWL clean it check with multimeter and refit it, clean body of generator from inside and outside properly and battery charger input & output properly and tightning of wiring if reqd, complete all as specified and directed by Engineer in Charge.Note:-1) Quoted rate include cost of oil filters, fuel pre-filters, fine filters and air filters.2) Quoted rate inclue labour and transport charges.3) Cleaning Clothes required is deemed to be included in quoted rates.4) Engine oil, distilled water, LLOP and HWT shall be measured separately. |
| 141 | M&L for calibration of wiring of engine safety control systems from control panel to engine control gadgets like high water temperature & low oil pressureand shut down valve, battery charger 12V, self starters etc for20 KVA to 62.5 KVA DG Set and repair all the safety features, complete all as specified and directed by Engineer in Charge. |
| 142 | M&L for repair and calibration of DG set governor mechanism as per calibration procedure and norms for 20 KVA to 62.5 KVA DG set installation and testing of the same after completion, complete all as specified and directed by Engineer in Charge. |
| 143 | M&L for repair and calibration of FIP, fuel injectors including replacement of barel plunger and cup \"O\" rings alongwith Plunger spring, Roller bearing, element, Delivery valve, Fuel injector nozzle element for 20 KVA to 62.5 KVA DG Setand testing of the same after completion, complete all as specified and directed by Engineer in Charge. |
| 144 | M&L for in replacement of auto voltage regulator complete with wire connection and connecting to existing field coil 12/24 Volt DC for cap of 20 KVA to 62.5 KVA, complete all as specified and directed by Engineer in Charge. |
| 145 | M&L for taking out radiator assemblyfrom existing DG set(20 KVA to 62.5 KVA)and repair to radiator tank, cleaning complete with anti corrosion chemical C-cleaner/ radiwash cleaner and fixing/making radiator leakage proof, complete all as specified and directed by Engineer in Charge. |
| 146 | Dismantling and taking out carefully defective water pump assembly 20 KVA to 62.5 KVA DG Setand opening into parts cleaning servicing and drying up the spares and sought out the damage/ defective parts and re-fixing the same after replacement of water pump repair kit and water seal unit including pump belt, complete all as specified and directed by Engineer in Charge. |
| 147 | S&F coupling complete (engine-alternator) in all respect with rubber flange as per existing shape/ size, with nut & boltsandsuitable for 20 KVA to 62.5 KVA DG Sets, complete all as specified and directed by Engineer in Charge. |
| 148 | M&L for repairs/ replacement of turbo charger including replacement of charger kit with all unserviceable parts and testing after completion for 20 KVA to 62.5 KVA capacity DG Sets, complete all as specified and directed by Engineer in Charge. |
| 149 | S&F in replacement of Self starter 24 volts DC engine, complete all as specified and directed by Engineer in Charge. |
| 150 | All as per Srl Item No 133 but 12 V DC, complete all as specified and directed by Engineer in Charge. |
| 151 | M&L for repair of worn out parts of self starter 24 volts DC including plunger, bush, armature, gear and pinion, field coil, coil of magnetic switch, complete all as specified and directed by Engineer in Charge.Note: (i) If replacement of any part of self starter is required than contractor has to replace without any extra cost. |
| 152 | All as per Srl Item No 135 but self starter 12V DC, complete all as specified and directed by Engineer in Charge. |
| 153 | S&F of Battery lead copper wire with thimble and terminal heavy duty made out of brass & 100 cm length of lead, complete all as specified and directed by Engineer in Charge. |
| 154 | M&L for Solenoid stopper coil 24 volts DC operated with lead and fixing clamps, complete all as specified and directed by Engineer in Charge. |
| 155 | M&L for Solenoid stopper coil 12 volts DC operated with lead and fixing clamps, complete all as specified and directed by Engineer in Charge. |
| 156 | Supply and filling coolant for radiator of any cap DG Set, complete all as specified and directed by Engineer in Charge. |
| 157 | Supply and fillingdistil water for batteries of DG set on site requirement, complete all as specified and directed by Engineer in Charge. |
| 158 | M&L for replacement of required broken MS Hinges and locks with keys with new one suitable for Canopy door for any type/capacity of DG Sets (as per sample)and make the DG set fully locked, complete all as specified and directed by Engineer in Charge. |
| 159 | S&F in replacement of low oil pressure switch 12/24V, 3.5 to 10 kg/Sq. cm, complete all as specified and directed by Engineer in Charge. |
| 160 | S&F in replacement of HWT switch 12/24V, complete all as specified and directed by Engineer in Charge. |
| 161 | Supply and filling the engine oil 20-40W by draining out old unserviceable engine oil, clean the the oil sump, complete all as specified and directed by Engineer in Charge. |
| 162 | S&F of Power contactor coil240/415 V AC Amp rating 115 to 225 A including taking down/out unserviceable one, complete all as specified and directed by Engineer in Charge. |
| 163 | S&F in replacement AMF Engine Controller with Operating Mode- Auto/ Semi Auto/Manual/ Test/ Off, Mains Protection-Single/ Three Phase, Under/Over Voltage, Under/Over Frequency, Over Current/ Short Circuit, Phase Reverse, Phase Unbalance, KW/ KWH, Run Time & Rest Time of DG, Sensor data selection ON/OFF, Single/ Three Phase Selection, 9 to 35 VDC including taking down/out old unserviceable ON/OFF Delay Timer Switch, Static battery charger all suitable for AMF Panels of 20 KVA to 62.5 KVA DG sets, complete all as specified and directed by Engineer in Charge. |
| 164 | M&L for replacement of sealed maintenance free generator starting systembattery 90 AH 12 Volt suitable to DG capacity 20 KVA to 62.5 KVAwith SMPS charger (self starting facility) including initial factory charging, complete all as specified and directed by Engineer in Charge. |
| 165 | M&L for calibration of AMF control wiring including opening disconnecting LT Cable connections with care from Auto-Main failure panel and checking throughly with Fault Detector Instrument at site suitable for 20 KVA to 62.5 KVA DG Set including replacement of Internal Wiring with Copper Conductor Cable lugs, thimble etc., complete all as specified and directed by Engineer in Charge. |
| 166 | S&F in replacement of Power Contactor 40 Amp to 100 Amp 4/3 Pole with 2NO + 2NC contacts on site requirement and coil Voltage 220/415 Volt including taking down unserviceable one, complete all as specified and directed by Engineer in Charge. |
| 167 | S&F in replacement of phase failure Relay suitable for AMF Panelany type including taking down unserviceable one, complete all as specified and directed by Engineer in Charge. |
| 168 | S&F in replacement of ON-Delay timer suitable for AMF Panel any type including taking down unserviceable one, complete all as specified and directed by Engineer in Charge. |
| 169 | S&F in replacementindicator lamps (Red/Green/Yellow) AC 230 V, LEDtype for the AMF panel boards, complete all as specified and directed by Engineer in Charge. |
| 170 | S&F in replacement Selector switch for volt meter/ ammeter, complete all as specified and directed by Engineer in Charge. |
| 171 | S&F in replacement Vibration pad front and back side suitable for 62.5KVA DG Set, complete all as specified and directed by Engineer in Charge. |
| 172 | S&F in replacement under/over voltage relay input voltage 110-220 V AC suitable for AMF panel, complete all as specified and directed by Engineer in Charge. |
| 173 | S&F in replacement engine starting relay DC 12V suitable forAMF panel, complete all as specified and directed by Engineer in Charge. |
| 174 | S&F in replacement 8 pin relay Base Socket voltage range DC voltage 12 V to 24 V and AC voltage 230 V to 440V suitable forAMF panel, complete all as specified and directed by Engineer in Charge. |
| 175 | S&F in replacement contact element NO-NCsuitable forAMF panel, complete all as specified and directed by Engineer in Charge. |
| 176 | S&F in replacement green and Red colour Actuator Push button with complete set suitable for AMF panel, complete all as specified and directed by Engineer in Charge. |
| 177 | S&F in replacement Automotive relay, 12 VDC, 50 Amp power relay quick connected with complete set suitable forAMF panel, complete all as specified and directed by Engineer in Charge. |
| 178 | S&F in replacementAmeter of range as requiredfor the Gen/ AMF panel, complete all as specified and directed by Engineer in Charge. |
| 179 | S&F in replacement Volt meter 0 to 600 V range suitable for the Gen/ AMF panel, complete all as specified and directed by Engineer in Charge. |
| 180 | S&F in replacement3 pole power contactor 55 A,type MNX 40, complete all as specified and directed by Engineer in Charge. |
| 181 | S&F Battery Charger of capacity 12V suitable for AMF Panel, complete all as specified and directed by Engineer in Charge. |
| 182 | S&F in replacementheavy duty battery terminals, heavy duty brass forged with nuts and bolts, complete all as specified and directed by Engineer in Charge. |
| 183 | S&F in replacement fuel pipe filter to FIPwire braided, complete all as specified and directed by Engineer in Charge. |
| 184 | S&F in replacement fuel pipeupto 15 mm size from fuel tank to the DG set & over flow return, complete all as specified and directed by Engineer in Charge. |
| 185 | S&F in replacement Solonoid valve of 62/20 KVA DG sets, complete all as specified and directed by Engineer in Charge. |
| 186 | Supply, installation & Testing Commissioning of Flame Proof Fuel Transfer pump, oil sealed, temp upto 300 degree Celsius, voltage 115V, AC 1.0 HP, seal material carbon housing, RPM 1725, Material Cast Iron, Heavy duty, positive displacement, Mechanical seal, self priming pump delivers from 18 GPM (114 LPM) and are combine above ground pumps with series 305 or 307 remote dispensers explosion proof UL/eUL listed motors systems are UL/eUL listed as well motor has sealed bearing heavy duty switch and thermal overload protection built in junction box integral check valve, pressure relief valve and strainer with suitable foundation nut bolt, rubber packing etc, complete all as specified and directed by Engineer in Charge.Note:-(i) foundation of above pump set should be above 1 Feet from ground level.(ii)Foundation cost is included in above quoted rate. |
| 187 | Supply and laying 25 mm bores of tubes heavy grade SS 304 material with all fittings such as elbow, union, TEE, socket, reducer, welding work any fitting required to laying of pipe for supply of fuel purpose to fixed complete laid in trenches/wall/ceiling, complete all as specified and directed by Engineer in Charge. |
| 188 | S&F ofGun-metal, globe or gate valves 25 mm dia with iron wheel head, screwed both ends for iron pipe, complete all as specified and directed by Engineer in Charge. |
| 189 | S&F single phase DOL starter with incorporating single phase pump starter -economical model and SS enclosure incorporating 2 pole definite purpose contactor, single pole MCB, Ammeter, ON/OFF push buttong, motor ON indicatorwith dry run protection, Having capacity 1.5 KW Capacitor rating50 MFD, MCB Range 32 Amp, MCB C Curve, complete all as specified and directed by Engineer in Charge. |
| 190 | S&F in replacement of new star delta starter with auxiliary contracts for remote auto starter, 4 pole contactor type TCI-DX, overload relay type LR3D/LR1D, auto start switch, 3 position selector switch for SPP auto/SPP/Manual on/off rocket switch voltmeter with selector switch, suppressed scale ammeter, motor ON/OFF trip indicator starting suitable for operating fire pump up to 10 HP jockey fire pump. Note:- The starter suitable to incorporate in existing enclosure, and contractor shall visit the site before quoting of tender. The contractor shall bound to bring star delta starter as existing model, if contractor fail to arrange to provide the same model then contractor will be provide a separate enclosure near existing panel and making all electrical and control wiring arrange free of cost, complete in all as specified and directed by Engineer in Charge.Model No. BE3SPSDX254322RS or existing make and model |
| 191 | S&F in replacement of MCCB 100A, 4pole 25KA with thermal magnetic settings by dismantling old one from panel/ feeder pillar box, complete in all as specified and directed by Engineer in Charge. |
| 192 | S&F in replacement of MCCB 200A, 4pole 25KA with thermal magnetic settings by dismantling old one from panel/ feeder pillar box, complete in all as specified and directed by Engineer in Charge. |
| 193 | S&F in replacement of MCCB 250A, 4pole 25KA with thermal magnetic settings by dismantling old one from panel/ feeder pillar box, complete in all as specified and directed by Engineer in Charge. |
| 194 | S&F in replacement of MCCB 63A, 3pole 25KA with thermal magnetic settings by dismantling old one from panel/ feeder pillar box, complete in all as specified and directed by Engineer in Charge. |
| 195 | S&F in replacement of Change over 100A, 4pole 25KA with thermal magnetic settings by dismantling old one from panel/feeder pillar box, complete in all as specified and directed by Engineer in Charge. |
| 196 | M&L for preparation of old steel surfaces and applying two coat of synthetic enamel white paint to steel tubular pole height 11 mtr from ground level alternative in and 1 mtr height from ground level yellow and black strips of 30 CM height each including numbering of Pole No with black paint, complete in all as specified and directed by Engineer in Charge. |
| 197 | S&F LED street light fitting 150 Watt 230 V AC outdoor type 5700 K with high pressure die cast aluminium hosing along with prismatic polycarbonate modular secondary lens optics with IP 66ingress protection. 4KV in-built and 10 KV external surge protection with top opening driver cover for easy maintenance with efficacy not less than 120 lm/W heat resistant. The LED driver shall be of isolated type with Constant Current Constant Voltage topology to ensure optimum driving of LEDs. The LED streetlight shall have power factor more than 0.95. The optical compartment shall be covered with heat resistant toughened glass for safety. The LED Street light should be top maintainable for easy maintenance LED street light shall be of Integral type complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete all as specified and directed by Engineer-in-charge.Make :- Bajaj Cat part No. ENXT P54L WH CR PC SD or equivalent to Havells or PhillipsNote :-(i)Driver and luminaire of LED fitting shall be of same manufacturer(ii) All T&P ie ladder, Tools, Safty glooves etc will be provided by the contractor without any extra costto height upto 25 mtr. (iii) If same capacity is not available next higher capacity shall be provided by the contractor without any extra cost. |
| 198 | S&F Flood light luminaire 150 watt 230 V AC outdoor type with poly carbonate optics die-cast housing, IP66 ingress protection, 4KV in -built and 10 KV external surge protection, Efficacy 110 Im/W complete suitable for input voltage140 Volt to 280 Volt, The LED flood light shall have power factor more than 0.95, 50000 L70,CRI>70,CCT 5665K ± 355K, THD <10%, IP 66,IK 07, Operating Temperature-10 degree Celsius to 50 degree Celsius, Beam Angle 70degree complete all as specified and directed by Engineer-in-charge.Bajaj Cat part No. GLATT MT 480L WH PO PC SD or Havells or PhillipsNote:-(i)Driver and luminaire of LED fitting shall be of same manufacturer(ii) All T&P ie ladder,Tools,Safty glooves etc will be provided by the contractor without any extra costto height upto 25 mtr. (iii) If same capacity is not available next higher capacity shall be provided by the contractor without any extra cost. |
| 199 | NOTE FOR REWINDING ITEM(i) Fans handed over to contractor for repair will be issued to contractor on issue voucher and the same are required to be taken back on receipt voucher.(ii) MES members to be mentioned on issue voucher and at the time of receipt of fans MES numbers have to checked to avoid any descrepencies at last stage. |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail