Tender For Supply And Installation Work Of Two Elevators In Gorakhpur Development Authority Office Building. - SITC of 10 Passenger Lift/ 680Kgs /1.25 M/s Speed/4 Floors/4 Stops/Stainless Steel Car Cabin .Detail specification as under :- 2 I -PRODUCT DETAILS 3 Building Type - Commercial Building 4 Lift Type - Passenger Lift 5 Rated Capacity Persons / Kgs / Class of Loading-10 Persons / 680 Kgs / P - Passengers 6 Rated Speed - 1.25 m/sec 7 Number of stops / openings - Four 8 Floor Designation-(B+G+2) 9 Access Sides Inline/Thru Type-1 (One), In Front Only 10 Floor Display Character (Entrance Position)-1(F),0(F),1(F),2(F) 11 II MACHINE AND CONTROLLER DETAILS 12 Machine Location / Type - Machine Roomless - Gearless 13 Drive System - Micro Processor Based VVVF - Closed Loop 14 Control system - Microprocessor Based Simplex Selective Collective Control With / Without Attendent 15 Main Power Supply - AC 3 Phase, 50 Cycles, 415 Volts ±10% 16 Light Power Supply - 220 Volts 50Hz LNE 17 III SHAFT DETAILS 18 Shaft Type-RCCRB - Reinforced Cement Concrete With Red Brick 19 Shaft Width mm X Shaft Depth mm - 2100 X 1650 20 Overhead mm - 7800.00 21 Pit Depth mm - 1600.00 22 Travel Height (in Meters) - 10.00 23 Shaft Reduction Channel 24 Pit Ladder 25 IV CABIN DETAILS 26 A) SIZES 27 Car Width mm X Car Depth mm - 1350 X 1300 28 Car Clear Height mm - 2200 29 Car Door Type Centre Opening Sliding Door 30 No Of Door Panels - 2 Panel 31 Type of Door Drive - Linear Door Drive System 32 Car Door (W X H) mm - 800 X 2000 33 B) FINISHES - 34 Design Of Lift Cabin- Stainless Steel 35 Lift Cabin Finish - Hairline Finish 36 Car Door - Stainless Steel 37 Car Door Finish - Hairline Finish 38 Ceiling Finish - SS Hairline Finish 39 Ceiling Type - Sleek Small Circular-J 40 Ceiling Light - Led Lights 41 Fan-Cross Flow Fan 42 Flooring Type - Pvc 43 Handrail Type - SS Round Handrail 44 Handrail Location - All 3 Sides 45 Car Door Sill - Aluminum 46 V LANDING DOORS DETAILS 47 A) SIZES 48 Door Type - Centre Opening Sliding Door 49 Door Size (W x H) mm - 800 X 2000 50 Door Sill - Aluminum 51 B) FINISHES 52 Landing Door Finish - 1-4-Stainless Steel - Hairline Finish 53 Landing Door Frame / Finish*-1-4-Stainless Steel - Hairline Finish 54 Main Landing Floor - 0 55 Other Landing Floors - 1,1,2 56 Jamb Type - Slim Frame 57 VI SIGNALIZATION / FIXTURES DETAILS 58 A) CABIN OPERATING PANEL 59 Car Operating Panel Type-Car Operating Panel - JLCP01 60 Number of Car Operating Panel - 1 61 COP Faceplate Finish-Stainless Steel - Hairline Finish 62 Button Model-1s4 - Bas128 63 Car Display - Orange Square Dot-Matrix Scrolling Display-Vertical 64 Car Display Location - Car Operating Panel 65 Handicaped Requirements 66 Call Register Signal 67 Floor Annunciator 68 B) LANDINGS INDICATORS 69 Landing Operating Panel type-Landing Operating Panel - JLLP01 70 LOP Location-Landing Display On Wall 71 LOP Mounting Type - Grouting 72 LOP Faceplate Material-Stainless Steel - Hairline Finish 73 Landing Display - 1-4-O SDM-V 74 Landing Display Location -1-4-LOP 75 Call Register Signal 76 Stainless Steel Braille Button 77 VII SAFETY DETAILS 78 Over Speed Governor 79 Door Protection - Infra Red Door Screen 80 Counterweight Screen - Inbuilt 81 Over Load Indicator 82 Fireman Switch 83 Automatic Rescue Device - 84 Battery Operated Emg Alarm Light - 85 Two Way Intercom with Press & Speak in COP - 86 DOOR OPEN AND DOOR CLOSE BUTTON 87 AUTO LIGHT & FAN SWITCH OFF (POD) 88 DOOR NUDGING / DOOR HOLD OPERATION 89 FIRE RATING OF LANDING DOORS - ONE HOUR 90 SCAFFOLDING 91 FREE SERVICE FOR ONE YEAR 92 MINOR BUILDERS WORK 93 PROVISION FOR CCTV CAMERA - IP (Cat6 flat travelling cable) 94 LIFT LICENSE ARRANGEMENT BY CONTRACTOR - DOCUMENTS & FEES BY CLIENT 95 Electric sefty Certificte provid by the contractor 96 Part-B- Electrical work 97 Supply & Erracetion of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreis Electrical control panel with TPN MCCBs (Four Pole 36 KA with thermal magnatic release)Switches Complete and instrument chamber etc.complete in all respects. The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters(KVA,P.F,KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel ard shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above istulated with heat shrink leeving and mounted on non hygroscopic supports such as CMC/BMC upport with deteachable side covers and shall be suitable for extension on the sides. The MCCBs shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. 98 The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubicle type switch board shall be of cat A & B Only.SI.NO-20.1.1/SOR-2024 99 Incoming 100 100 Amp MCCB -1 No 101 Outgoning 102 32 Amp. MCCB-3 Nos. 103 Cat. B. Pannel Cubicle Type 104 S/L of AL conductor PVC insulated armoured served sheathed cable 1100 V grade at a depth of 750mm below G.L. with 75mm thick fine send andprotected with brick on side and top surface the cable run shall be fixed by clamp of following size. SOR-2024 105 (i) 16mm2X4 Core (i)(20a1.9) 106 (ii) 50mm2x31/2 Core (k) (20a1.12) 107 Supply and burring of Safe EarthingElectrode T-19,(Hot Dip Galvanized), Length up to 3000mm, outer pipe48.4 mmx3.2mm inner pipe 26mmx2.6, terminal Dia 12mm coating 80-100 micron filled with crystalling conductivemixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of reataining capacity along with 30 cm square C.I. frame with hinged cover & masonry housing. (From electrode terminal to switch board, cost of 25x3 G.I. Strip will be extra)Make: AS approved in U.P. P.W.D., & C.P.R.I. Certified. (P.W.D 725B/18) 108 Wiring point for light with 1.5 sq. mm.FRLSH PVC insulated multistrand single core copper conductor cable insulated multistrand single core copper conductor cable in heavy guage PVC conduit pipe on surface, complete with 14 SWG copper earth continuity wire,GP Box ,piano type switch and ceiling rose/angle/ batten holder on 3 mm. thick phenolic laminated backelite sheet etc. complete in all respect, as directed . S.NO 121 C/SOR-2018 109 S/F of10 W– 6000 K Bulkhead LED Light (Mak-Poly CAB PLT0101316) PSR. 110 Part-C- Civil work 111 Dismentaling reinforced cement concrete or reinforced brick work, including stacking of dismentaled materials as directed by Engineer-in-charge within a distance of 60m. 112 Dismentaling ofbrick work including stacking of dismental material etc. S.I 692 113 Concrete with 4.00cm (1½) gauge approved stone ballast, approved coarse sand and cement in the proportion of 8:4:1 including supply of materials, labour T&P etc. required for the proper completion of the work. (UPPWD SOR SI-281/2020) 114 R.C.C. work with cement approved coarse sand and 2.0cm (3/4) gauge approved stone grit in the proportion of 1:1½:3 in slabs excluding supply of reinforcement and its binding butincluding its fixing and binding the same with 24 B.W.G.G.I. binding wire and including necessary centering and shuttering etc. and alsoincluding supply of all material, labour and T&P etc. required for proper completion of the work. binding wire cost being included in the item. (UPPWD SOR S.I.No-284A) Slab 115 M-150 class brick work in 1:4 cement and coarse sand mortar in in supper strutur for 9 thick wall including supply of all materials, labour and T&P etc. required for proper completion of the work. (S.I.No-305+309+310) 116 Steel reinforcement for R.C.C.work including straightening ,cutting,bending ,placing in position and binding all complete upto plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more DSR-5.22.6(2023) Beam, Ring,raft. 117 R.C.C. work with cement approved coarse sand and 2 cm (3/4) gauge approved stone grit in the proportion of 1:2:4 in lintels of doors and windows excluding supply of reinforcement and its binding but including its fixing and binding the same with 24 B.W.G.G.I. binding wire and including Necessary centering and shuttering etc.and also including supply of all materials, labour and T&P etc. required for proper completion of the work. Binding wire cost being included in the item. As in item (283) above but in R.C.C. T-beam and slab roofs and R.C.C. columns. S.I-288. beam 118 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite stone slab all colour and texture except black, Cherry/Ruby red (D.S.R 8.2.3/2023) Area of slab over 0.50 sqm (D.S.R 8.2.3.2/2023) 119 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.(D.S.R. - 13.80/2023) 120 Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.(D.S.R. - 10.1/2023)