| Sl. No. | Item Description |
| 1 | Taking down aluminium point wiring for light, fan, bell socket, power socket etc complete including fittings and fixtures removing from site and making good disturbed surfaces of walls, floors, etc complete all as directed by Engineer-in-Charge. |
| 2 | Material and labour for point wiring using approved colour coding as per IS, with multi stranded copper conductor 1.5 sqmm (Nominal area). Single core, FRLSH, PVC insulated and unsheathed stranded cable drawn through, PVC casing caping of size not less than 20 mm including all tees, bell mouth pieces and fixing accessories such as couplers, saddlers, hooks etc, PVC Junction boxes ISI marked with GI flush boxes / sunken boxes made out of 1.2 mm thick of any module from 2 to 18 moudule with earth dolly including modular cover plates with frame i.e inner and outer plate extended upto 25 mm over sunken box for housing the modular switches outlets, fan regulators etc with brass screws and brass washers and making good the disturbed surfaces as per existing for one light / fan / bell point controlled by one switch including 1.5 sqmm single core PVC insulated and unsheathed FRLSH copper cable, 1100 volt grade with multi stranded copper conductor green colour as earth continuity conductor upto common earth and connecting to common earth dolly with suitable size of lugs for one light switch complete all as specified and as directed.NOTES:-(i) Point wiring & earth wire shall be connected to each & every flush / sunken box.(ii) All screws, fasteners, bolts, nuts & washer shall be cadmium plated & the cost of which is deemed to be included in the quoted unit rates.(a)One light / Fan / Ex FEan / Bell / Point controlled by one, one way switch / bell push. |
| 3 | All as per Srl Item No 2 above butwith but One socket outlet 3 or 5 Pin, 6 Amp on on same board all as specifeid and as directed. |
| 4 | All as per Srl Item No 2 above butwith 2.5 Sqmm copper cable for One socket outlet 3 or 5 Pin, 6 Amp on independent board all as specifeid and as directed. |
| 5 | All as per Ser item No 2 above but with 2.5 sqmm copper cablefor socket outlet 5/6 pin 15 Amps all as specified and as directed. |
| 6 | All as per Ser item No 2 above but with 4.00 sqmm copper cable for Ac Socketall as specifed and as directed. |
| 7 | Material and labour for concealed point wiring using approved colour coding as per IS, with multi stranded copper conductor 1.5 sqmm (Nominal area), single core, FRLSH, PVC insulated and unsheathed stranded cable drawn through and including non metallic, heavy duty PVC concealed conduit not less than 20mm dia and its fittings including all tees, bell mouth pieces and fixing accessories such as couplers, saddlers, pipe hooks etc, PVC junction boxes ISI marked with GI flush boxes / sunken boxes made out of 1.2mm thick of any module from 2 to 18module confirming to IS-5139(pt-I) of 1969 and IS:14772-2000 with earth dolly including modular cover plates with frame i.e. inner and outer plate extended upto 25 mm over sunken box for housing the modular switches, socket outlets, fan regulators etc with brass screws and brass washers and making good the disturbedsurfaces as per existing for one light / fan / bell point contorlled by one switch including 1.5 sqmm single core PVC insulated and unsheathed FRLSH copper cable, 1100 volt grade with multi stranded copper conductor green colour as earth continuity conductor upto common earth and connecting to common earth dollywith suitable size of lugs for one light point/ fan point/bell point controlled by one switch complete all as specified and as directed.NOTES : - (i) The quoted rates shall be deemed to be inclusive for cutting chases by chase cutter in wall/pillars/columns etc. of any description for concealing the conduits to required depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface to match with the existing surface. The portion of point wiring at ceiling shall be in surface conduit of suitable size fixed on ceiling surface with using necessary accessories/fittings. (ii) Point wiring & earth wire shall be connected to each & every flush/sunken box. (iii) All screws, fasteners, bolts, nuts & washer shall be cadmium plated & the cost of which is deemed to be included in the quoted unit rates.One light /Fan /Ex Fan/Bell point controlled by one, one way switch |
| 8 | All as per Srl Item No 7 above butOne socket outlet 3 or 5 Pin, 6 Amp on same board all as specified and as directe. |
| 9 | All as per Srl Item No 7 above butwith 2.5 Sqmm copper cable for One socket outlet 3 or 5 Pin, 6 Amp on independent board all as specified and as directe. |
| 10 | All as per Ser item No 7 above but with 2.5 sqmm copper cable for socket outlet 3 or 6 pin 15 Amps all as specified and as directed. |
| 11 | All as per Ser item No 7 above but with 4.00 sqmm copper cable for Ac Socketall as specifed and as directed. |
| 12 | S&F modular switch 6 Amp one way 230 V AC complete all as specified and directed by Engineer-in-charge. |
| 13 | S&F modular bell push, 6 Amps, 1 module single pole complete all as specified and directed. |
| 14 | S&F modular switch 16 Amp one way 230 V AC complete all as specified and directed by Engineer-in-charge. |
| 15 | S&F modular socket outlet 6Amp intel multi socket for all pins 230 V AC complete all as specified and directed by Engineer-in-charge. |
| 16 | S&F modular socket outlet 16Amp and 6/16 Amp heavy duty 230 V AC complete all as specified and directed by Engineer-in-charge. |
| 17 | S&F modular type fan step regulator up to 120W - 2 module complete all as specified and directed. |
| 18 | S&F for switch paino flush type/bell push 6 Amps single pole one way 230 volts AC circuit as fixed in repairs complete all as specified and directed. |
| 19 | S&F switch socket combination 2 in 1 3/5 pin 6 Amps 240 volts flush type multipurpose as fixed in repairs complete all as specified and as directed. |
| 20 | S&F switch socket combination 2 in 1 5/6 pin, 16 Amps flush type 240 Volts universal as fixed in repairs complete all as specified and as directed. |
| 21 | S&F Electronicfan regulator 230 volts, step type, flushtype,ISI Marked, as fixed in repairs complete all as specified and as directed. |
| 22 | M&L for ceiling rose, surface bakelite three terminals PVC/Polycarbonate, isolated body (ISI Marked) |
| 23 | S&F call bell AC 230 Volts single pole complete with all accessories internally pre-wired and fixed to walls/ceiling on PVC Box with screw, all as specified and directed. |
| 24 | S&F PVC/polycarbonate Lamp Holder insulated body with back plate angle type suitable for batten complete all as specified and directed by Engr-in-charge . |
| 25 | S&F LED Lamp 9 watt Selfballasted type with PBT body shell and DC Diffuser as fixed in repairs complete all as specified and directed. |
| 26 | Supply and fixing of Inverter LED tube light fitting 1x20 Watt with minimum 04 hours battery back up integratedbatten with diffuser and including 20 Watt LED hight efficient , AC 220-240 V, 50 Hz and connecting with copper conductor flexible cable of size 0.50 Sqmm from ceiling rose to connectorof the light including disconnecting and taking down old existing light fitting of any description and in any position complete all as specified and directed. |
| 27 | Fixing only serviceable LED Tube lights fitting 1 x 18/20 Watt, 4 feet ,220V AC obtained from item No 1.00 above. |
| 28 | Supply and fixing of LED light fitting 1x20W, 220V, AC, batten type with driver , holder including 20W LED tube light for connecting up withflexiable copper conductor cable of suitablae size from celing rose to connector including disconnecting and taking down old existing light fitting of any description and in any position complete all as specified and directed. |
| 29 | Supply and fixing of batten type withsurface mounted LED tube light fitting with high efficient diffuser mirror light, aluminium housingin CRCA body suitable and including 10 watt LED tube rod high efficient, AC 220-240 volts, 50 Hz and connecting with copper conductor flexible cable of size 0.50 Sqmm from ceiling rose to connector of the light including disconnecting and taking down old existing light fitting of any description and in any position complete all as specified and directed. |
| 30 | S&F LED Bulk head fitting 10 watt in engineering plastic housing with clear prismatic diffuser complete with all accessories internally pre-wired and fixed to walls/ceilingwith screw including connecting up with twin coreflexible copper conductor cable with suitable size, including taking down old unsv fitting complete all as specified and directed. |
| 31 | S&F Aesthetically designed recessed mounted panel 1x1 Feet LED light 18/24 Wattflatround/square type for surface/ceiling mounting which provides soft-light and glare free symmetrical illumination including suitable size flexible copper cable and taking down old unsv light fitting all as specified and directed. |
| 32 | S&F Aesthetically designed recessed mounted panel 2x2 Feet LED light 30/36 Wattflat square type for surface/ceiling mounting which provides soft-light and glare free symmetrical illumination including suitable size flexible copper cable and taking down old unsv light fitting all as specified and directed. |
| 33 | Supply and fixing of LED security light luminaire 30/35 watt , pressure die cast aluminum housing, toughened heat resistant glass, IP66 protection, better optics for uniform distribution with multiplte LEDshaving optical grade polycarbonate lens with all accessories internally pre wired and including connecting up with two core 1.5 sq mmcopper conductor cable from connector to ceiling rose to connection of light including disconnecting and taking down oldunserviceable security light fitting of any description and in any positioncomplete all as specified and directed. |
| 34 | M&L for providing sub main wiring with two single core 6.00 Sqmm (nominal area) PVC Insulated FRLSH unsheathed multi stranded copper conductor cable 1100 volts grade drawing through PVC casing-capping/ PVC Conduit complete as per direction/site rquirement including 6.00 Sqmm PVC insulated unsheathed multi stranded FRLSH single core copper conductor cable for earth wire including taking down/removing old one and making good distrubed surfaces of walls, floors, etc complete all as specified and directed. Note : (i) Three runs of single core 6.00 Sqmm multi stranded copper cableand one run of casing caping/conduit shall be measured as one run length (ii) Extra length of cable required for connection to DBs/MCBs shall deem to be included in unit rate quoted by contractor against the item (iii) Earth wire run inside the casing capping/conduit. |
| 35 | All as per Ser item No 34 above but with 4.00 sqmm copper cable (nominal area) |
| 36 | S&F single pole and neutral enclosure with a two pin and earth plug and socket complete with one number single pole MCB 20 Amps , 240 Voltscomplete all as specified and as directed. |
| 37 | Supply, installation, testingofSPN distibution board 8 way,double door , IP 43, as per IS 8623including 100 Amps fully insulated copper bus bar, insulated neutral bar, earth bar, door earthing, reversible doors, PAN assembly for easy installation and also incoming and outgoing connections with suitable size of lugs/thimbles/glands including taking down existing unserviciable MCB/DBs including MCBs complete all as specified and directed. |
| 38 | Supply, installation, testingofSPN distibution board 4 way,double door , IP 43, as per IS 8623including 100 Amps fully insulated copper bus bar, insulated neutral bar, earth bar, door earthing, reversible doors, PAN assembly for easy installation and also incoming and outgoing connections with suitable size of lugs/thimbles/glands including taking down existing unserviciable MCB/DBs including MCBs complete all as specified and directed. |
| 39 | S&F MCB 25 to 32 Amp SP&N, 240 volts 10 KA \"C\" series with all incoming/outgoing connections with proper size lugs including taking down old unserviceable one complete all as specified and directed. |
| 40 | S&F MCB 6 to 32 Amp SP, 240 voltss 10 KA \"C\" series with all incoming/outgoing connection with proper size lugs including taking down old unserviceable complete all as specified and directed. |
| 41 | S&F in repair PVC rigid rectangular blocks, with back plate complete of sizes 10x10x5 cm as fixed in repair complete all as specified and as directed. |
| 42 | All as per item No 41 here-in-before but size 17.5x10x5 cm as fixed in repair complete all as specified and as directed. |
| 43 | Material and labour for taking out old unserviceable burnt out electric monoblock motor with pump from the foundation of pump capacity 10 HP, 440 Volts, 50 Hz by opening/disconnecting all mechanical and electrical connections and transporting to nearest work shop and rewinding the same by using approved make super enamelled insulation copper wire of suitable insulation class of approriate size after pulling out burnt out copper wires from the slots of startor including replacement of minor accessories like mica paper, sleeves, glass fibre, bamboo pieces etc. including varnishing/heating at heat chamber suitably and opening the monoblock pump assembly for replacement of unserviceable parts, servicing by grease , maintenance and reassembling all as per existing complete and taking back the whole pump sets to its original location and fixed or placed suitably including making the electrical and pipe connections including testing to get satisfactory result complete all as specified and as directed.Note: (i) Parts if required for pump shall be measured and paid separately here-in-after under another item as \"supply only\".(ii) Work for rethreading/grinding/metal surfacing and fabrication works to pump or rotor shaft shall be measured & paid separately under separate items here-in-after. |
| 44 | All as per item No. 43 here-in-before but Pump set of capacity 20 HP. |
| 45 | Material and labour for opening or pulling the worn out rotor shaft of electric motor/pump of capacity 10 HP from the pump set by removing all connected nuts, bolts, bearing covers, cooling fan and bearing etc. and same is brought to nearby metalling shop for remetalling of surface/re-threading/grinding and fabrication job on shaft and servicing of monoblock pump by providing gland packing and grease of approved grade suitably and re-fitting properly to their original location as per direction of Engr-in-charge complete all as specifed and directed.Note:- Spare partsshall be measured and paid separately under relevant items. |
| 46 | All as per item No. 45 here-in-above but for pump set of capacity 20 HP. |
| 47 | Supply only single metal impeller for 10 HP monoblock pump set of model KDS-1040+ as per existingcomplete all as specified and directed. |
| 48 | Supply only single metal impeller for 20 HP monoblock pump set of model KDS-2050+as per existingcomplete all as specified and directed. |
| 49 | Supply only double metal impeller for 20 HP monoblock pump set of model KDT-2070+as per existingcomplete all as specified and directed. |
| 50 | Supply only ball bearing of 6308 including taking out/dismantling old unserviceable one at pump housecomplete all as specified and directed. |
| 51 | Supply only ball bearing of 6307 including taking out/dismantling old unserviceable one at pump house complete all as specified and directed. |
| 52 | Supply only pump shaft of 10 HP as per existing modelcomplete all as specified anddirected. |
| 53 | Supply only pump shaft of 20 HP as per existing modelcomplete all as specified anddirected. |
| 54 | Supply only cooling fanof model M 132 for 10 - 20HP as per existing modelcomplete all as specified anddirected. |
| 55 | Supply only mounting casingfor Model KDS-1040+ of 10 HP monoblock pump as per existing modelcomplete all as specified anddirected. |
| 56 | Supply only mounting casingfor Model KDS-2050+/KDT-2070+ of 15/20 HP monoblock pump as per existing modelcomplete all as specified anddirected. |
| 57 | M&L for Taking up electric driven submersible motor & pump set of capacity 7.5to 15 HP from bore well complete with column pipe upto submersible depth by using chain pulley and allied T&P required and taking to the work shop for repair and lowering the same after repair in the existing bore well, making all the electrical connections including commissioning, testing complete on full load to the entire satisfaction of Engr-in-charge. |
| 58 | Dismantling all the parts of submersible pumps set complete with submersible motor, 3 phase 50 hz, 415 volts AC, of capacity 15 HP capacity, checking all parts, segragating the serviceable parts for reuse, removing the defective parts and repair the same (as describe below)including re-assembling, connections and testing complete all as specified and directed by Engr-in-charge.(a)Cutting the burnt out winding and cleaning of moving parts properly using petrol/suitable solvent and re-winding the complete stator winding with approved identical gauge and length of PVC insulated copper wire suitable for submersible motor rewinding including connected works complete to the entire satisfaction of Engr-in-charge.(b) Repair the motor shaft assembly by welding, cutting, grinding and polishing etc complete all as specified and directed.Note: (Spare required shall be measured and paid as \"supply only\" rate under relevant items of this schedule). |
| 59 | All as per item No. 58 here-in-before but Submersible Pump set of capacity 7.5 HP. |
| 60 | Supply only thrust bearing complete all as specified and as directed. |
| 61 | Supply only thrust plate complete all as specified and as directed |
| 62 | Supply only stainless steel sand guard for 7.5 / 15 HP submersible pump complete all as specified and as directed. |
| 63 | Supply onlymotorbush complete all as specified and as directed. |
| 64 | Supply only shaft sleeve set complete all as specified and as directed. |
| 65 | Material and labour for taking out old unserviceable burnt out electric horizontal split casing motor from the foundation of capacity 40 HP, 440 Volts, 50 Hz by opening/disconnecting all mechanical and electrical connections and transporting to nearest work shop and rewinding the same by using approved make super enamelled insulation copper wire of suitable insulation class of approriate size after pulling out burnt out copper wires from the slots of startor including replacement of minor accessories etc.including varnishing/heating at heat chamber suitably and opening the assembly for replacement of unserviceable parts, servicing by grease , maintenance and reassembling all as per existing complete and taking back the whole pump sets to its original location and fixed or placed suitably including making the electrical and pipe connections including testing to get satisfactory result complete all as specified and as directed. |
| 66 | Material and labour for taking out old unserviceable burnt out electric monoblock motor with pump from the foundation of pump capacity 2 HP, 440 Volts, 50 Hz by opening/disconnecting all mechanical and electrical connections and transporting to nearest work shop and rewinding the same by using approved make super enamelled insulation copper wire of suitable insulation class of approriate size after pulling out burnt out copper wires from the slots of startor including replacement of minor accessories etc.including varnishing/heating at heat chamber suitably and opening the monoblock pump assembly for replacement of unserviceable parts, servicing by grease , maintenance and reassembling all as per existing complete and taking back the whole pump sets to its original location and fixed or placed suitably including making the electrical and pipe connections including testing to get satisfactory result complete all as specified and as directed. |
| 67 | All as per item No. 66 here-in-before but for 0.5 HP / 0.37 KW motor. |
| 68 | Supply & fix cheminject chemical dozing pump model RC-11 electromagnetic type with accessories like anti siphon valve, suction / discharge tubing capable to deliver 6 LPH @ 4 Kg / sqcm back pressure incuding takin down old u/s complete all as specified and as directed. |
| 69 | supply and laying MS pipe heavy grade with all fittings laid in floor or fixed to the walls/staging or celling of size 150 mm bore including taking down of old u/s pipe from any position all as specified and as directed by Engr-in-charge. |
| 70 | supply and laying MS pipe heavy grade with all fittings laid in floor or fixed to the walls/staging or celling of size 100 mm bore including taking down of old u/s pipe from any position all as specified and as directed by Engr-in-charge. |
| 71 | supply and laying MS pipe heavy grade with all fittings laid in floor or fixed to the walls/staging or celling of size 80 mm bore including taking down of old u/s pipe from any position all as specified and as directed by Engr-in-charge. |
| 72 | Material and labour in replacement MS fittings for double ended flanged MS pipe such as bends (any type, any radius) tapers any type, Tee, pieces, collars, caps plugs etc.including leakproof jointing by welding/threading wk etc. to existing MS / GI pipe line system from 80mm to 150mm bore complete all as specified and as directed by Engr-in-charge. |
| 73 | Material and labour in replacement MS flange heavy duty 150mm through welding job with MS pipe / fittings of size 150mm bore alongwith nut / bolts / gland packing etc. for making it leakproof complete all as specified and as directed by Engr-in-charge. |
| 74 | All as per above item No. 73 but for MS flange heavy duty 100 mm. |
| 75 | All as per above item No. 73 but for MS flange heavy duty 80 mm. |
| 76 | Material and labour for preparation of old painted or plastered surfaces of walls / columns etc. of Over head RCC water tank (15 mtr to 18 mtr height) by washing, rubbing down, stopping of distempered and painted surfaces and applying two coat of cement base paint complete all as specified and as directed by Engr-in-charge. |
| 77 | Supply and fixing water pressure gauge 4\" dial 0 TO 14 Kg/Sq cm including clamps, nuts, bolts & washers complete all as specified and as directed.. |
| 78 | Dismantling existing foundation for concrete in ground floor pavement etc., not exc 115 cm thick but above ground level, complete all as specified and as directed by Engr-in-charge. |
| 79 | Material and Labour Cement concrete (1:2:4) type B-2 (using 40mm graded crushed stone aggregate)for foundation complete all as specified and directed. |
| 80 | Dismantling and taking down existing pressed steel bottom plates of size 1.22 mtr x 1.22 mtrx 6mm or side plates of size 1.22mtrx1.22 mtrx5mm thick as directed from 9600 gallons capasity steel Overhead tanks on 12 metre high stagging carefully without damaging other members after unscrewing bolts, nuts,washers etc and separating serviceable plates and keep in safe custody for reuse at site complete all as specified and as directed. |
| 81 | Supply, erection, hoisting and fixing of new pressed steel bottom plates of size 1.22mx 1.22mx 6mm thick made to required shape, drilling necessary holes for fixing bolts and nuts including provision ofproper arrangement of lead joint in between platesas require at site to existing water tank at 12 mtr high stagging complete all as specified and directed. |
| 82 | Supply, erection, hoisting and fixing of new pressed steel side plates of size 1.22mx 1.22mx 5mm thick(with necessary jointing materials) made to required shape, making necessary holes through drilling for fixing of bolts and nuts including provision ofproper arrangement of lead joint in between platesas require at site to existing water tank at 12 mtr high stagging complete all as specified and directed. |
| 83 | Fixing only old serviceable and repaired pressed steel side plates of size 1.22mx1.22mx5mm & bottom plates 1.22mx1.22mx6mm thick(with necessary jointing materials) made to required shape, making necessary holes through drilling for fixing of bolts and nuts including provision ofproper arrangement of lead joint in between platesas require at site to existing water tank at 12 mtr high stagging complete all as specified and directed. |
| 84 | Repairs to damaged portion of pressed steel tank plates for9600 Gallons PS Overhead Tank of existing gauge and size by means of welding over the hole upto 20mm dia with new Mild Steel plate of size 15 cm x 15 cmx6mm thick on the inner side of PS tank and testing complete all as specified and as directed. |
| 85 | Dismantling of rusted angle iron bracing and tie bar / I-section etc. from Pressed Steel overhead Tank on 12 meter high staging by unscrewing nuts, bolts and washers etc complete all as specified and as directed. |
| 86 | Material and labour for mild steel Fe 410 -W (Gde- E- 250) quality- A Fe angle iron as in tie bar, cross arm, bracing, I-section etc. as required and directedincluding making necessary holes through drilling for fixing of bolts and nuts to existing pressed steel tank on 12m high stagingand paintingwith two coats of aluminium painting over a coat of red oxide zinc chrome primer complete all as specified and as directed. |
| 87 | Supply, erection, hoisting and fixing of mild steel top plate/roof sheet 3.15 mm thick made to required shape by making necessary holes through drilling for fixing of nuts, bolts and fixed to existing pressed steel water tank on 12 metre high staging including dismantling/taking down existing unserviceable sheet complete all as specified and as directed. |
| 88 | Fixing only serviceable nuts, bolts and washers of appropriate length and of dia 16 to 20 mm required for fixing of steel plate, tie bars and bracing, I-section etc. etc complete all as specified and directed. |
| 89 | Supply and fixing mild steel machine made nuts, bolts and washers etc dia of 16 to 20 mmas required for fixing of steel plate, tie bars and bracing, I-section etc. etc complete all as specified and directed. |
| 90 | Material and labour for preparinginternal surfaces of PS over head tank, 12 mtrs high stagging of 9600 gallons capacity, over 10 cm width or girth, and applying with two coats of black bituminous paint ( suitable for drinking water purpose) complete all as specified and as directed. |
| 91 | Material and labour for preparing external surfaces of PS over head tank, 12 mtrs high stagging over 10 cm width or girth, scraping with steel wire brushes and applying two coats of aluminium paint (over surface of PS tank ,stagging, etc) over a coat of red oxide zinc chrome primer, complete all as specified and as directed. |
| 92 | Material and Labour for replacement of foundation channel of various size as per site requirement for alignment of pump set including suitable size nut & bolts etc. complete all as specified and as directed. |
| 93 | M&L for MCCB 4 pole, 415 volt,adjustable type 200 amps operated with breaking capacity of 36KA of make L&T D-sine complete all as specified and as directed. |
| 94 | M&L for MCCB 4 pole, 415 volt,adjustable type 400 amps operated with breaking capacity of 36KA of make L&T D-sine complete all as specified and as directed. |
| 95 | M&L for MCCB 4 pole, 415 volt, fixed type 63 amps front/knob operated with breaking capacity of 16KA complete all as specified and as directed. |
| 96 | Supply & Fixing of fully automatic star delta starter sheet metal enclosureof make L&T type MN-25F or equivalent suitable for 10 HP motor , 440 volt, 3 Ph Elect Motor with Single Phase Protection and motor protection relay feature conforming to IS -60947 after taking down old unserviceable one and fixed to the same location by making electrical connection properly complete all as specified and as directed. |
| 97 | Dismantling and removing burnt out contactor and Supply and fixing Contactor 3-Pole with AC Coil, 415 Volt, 50 Hz, Type- MNX 18/ MNX 25 of makeas per existing sample, complete all as specified and as directed. |
| 98 | Dismantling and removing burnt out contactor and Supply and fixing Contactor 3-Pole with AC Coil, 415 Volt, 50 Hz, Type- MNX 32 of makeas per existing sample, complete all as specified and as directed. |
| 99 | Material and labour for disconnecting of unserviceable submersible cable, and replace with new 6 Sqmm Flat Three Core PVC Insulated & PVC Sheathed Industrial Cable for Submersible Pump Motors, 1100 Volts Conforming to IS: 694 including lugs/washer at location as and when directed by Engr-in-charge after dismantling old unserviceable one complete all as specified and directed. |
| 100 | Material and labour for cleaning and removing all scales,silts,mud and dust, dirts etc.from RCC service water tankmanually and cleaning, scraping inner surfaces of tank by means of wire brush and then washing with cleanwater and cleaning of mouths of circulating pipes etc. and thoroughly washed with clean water of capacity of tank exceeding 500 litres but not exceeding 1000 litres including writing date of cleaning on outer body of the tank with 100mm high by synthetic enamel paint (white/black colour) complete all as specified and directed. |
| 101 | All as per Serial item No. 100 here-in-before but capacity of RCC water tank exceeding 1000 litres but not exceeding 2000 litres. |
| 102 | Material and labour for cleaning and removing all scales,silts,mud and dust, dirts etc.from PVC service water tankmanually and cleaning, scraping inner surfaces of tank by means of soft brush and then washing with cleanwater and cleaning of mouths of circulating pipes etc.of capacity of tank exceeding 500 litres but not exceeding 1000 litres including writing date of cleaning on outer body of the tank with 100mm high by synthetic enamel paint (white/black colour) complete all as specified and directed. |
| 103 | All as per Serial item No. 102 here-in-before but capacity of PVC water tank exceeding 250 litres but not exceeding 500 litres, complete all as specified and as directed. |
| 104 | Collecting water sample in clean bottle from location as directed for testing of Physical test, Chemical test & Bacteriological test as per IS-10500-2012 (second revision)from NEIST JORHAT / PHED Dibrugarh or any government recognized institute and submitting test report complete all as specified and as directed.(Note : Test will be conducted at the interval of 3 month) |
| 105 | Material & Labour for cleaning/washing Lamella Clarifier tank of capacity 17000 Gallons alongwith Flocculation tank by using a high-pressure cleaner, spray the lamella surfaces with pressurized water while the decanter is still filled & ensuring the pressure not eceeded by 5 bar & continue spraying while the clarifier empties while keeping the scraper operating and sludge purge pumping and other relavant arrangement for taking out deposited sludge, soil etc., from the bottom including cleaning inside walls of Flocculation tank with steel wire brush, gunny bags, etc and washing/cleaning and removing sludge, soils etc to a distance not exceeding 50 metre from the pump house campus area, and deposited where directed complete including writting the words \"Date Cleaned on\" on the Front/Road side face complete all as specified and as directed. |
| 106 | Material & Labour for cleaning/washing of Ground level storage sump of 20000 gallons capacity after complete pumping out of water from the static tank (Pumpset is own arrangement of thecontractor) and removing all dirts/sludge by scraping with steel wire brush/ gunny bags cleaning/ washing thoroughly floor and inner walls with bleaching powder solution and removing sludge/soils etc., to a distance not exceeding 50 metre from pumphouse campus, including writting the words \"Date Cleaned on\" on the Front/Road side face complete all as specified and as directed. |
| 107 | Material & Labour for cleaning/washing of Ground level storage sump of 25000 gallons capacity after complete pumping out of water from the static tank (Pumpset is own arrangement of thecontractor) and removing all dirts/sludge by scraping with steel wire brush/ gunny bags cleaning/ washing thoroughly floor and inner walls with bleaching powder solution and removing sludge/soils etc., to a distance not exceeding 50 metre from pumphouse campus, including writting the words \"Date Cleaned on\" on the Front/Road side face complete all as specified and as directed. |
| 108 | Material & Labour for cleaning/washing pressed steel Overhead Tank 9600 gallons capacity, 12.00 meter high staging after complete dewatering and removal of all dirts/ sludge by scraping with steel wire brush/ gunny bags, washing thoroughly floor and inner walls and draining/ washed out before fresh water filled including writting the words \"Date Cleaned on\" on the Front/Road side face of pressed steel OH Tank including necessary scaffolding works complete all as specified and as directed. |
| 109 | Material & Labour for cleaning/washing of RCC Overhead Tank 50000 Gallon capacity, 50 feet high staging after complete dewatering and removal of all dirts/sludge by scraping with steel wire brush/gunny bags, cleaning/washing thoroughly floor and inner walls with bleaching powder solution and drained/washed outincluding necessary scaffolding works including writting the words \"Date Cleaned on\" on the Front/Road side face complete all as specified and as directed. |
| 110 | Material & Labour for cleaning/washing of Ground level storage sump of 50000 gallons capacity after complete pumping out of water from the static tank (Pumpset is own arrangement of thecontractor) and removing all dirts/sludge by scraping with steel wire brush/ gunny bags cleaning/ washing thoroughly floor and inner walls with bleaching powder solution and removing sludge/soils etc., to a distance not exceeding 50 metre from pumphouse campus, including writting the words \"Date Cleaned on\" on the Front/Road side face complete all as specified and as directed. Note:- For Item Nos : 104 to 110 (a)Materials and sundries items etc. required for cleaning shall be arranged by the contractor from his own sources and cost for the same shall deem to be included in the unit rate.(b)Cleaning shall be carried out as required and directed with all arrangments as requered so as to complete the work in time to avoid disturbance in water pumping system. |
| 111 | Taking out from trenches or taking down from wall GI steel tubing and connections, 20 mm bore, setting aside andcleaning the serviceable pipe for re-laying/ re-fixing or removal of unserviceable pipe from site of work complete all as directed. |
| 112 | Re-fixing/ Re-laying of old serviceable GI pipes 20 mm bore , obtained from taking out here-in-before, with all new fittings and laid in trenches/wall complete all as specified and as directed |
| 113 | Supply and fixing of20 mm bore GI tubing, medium grade with allnew fittings as required complete fixed to walls and ceilings or laid in floors/trenchesincluding testing complete all as specified and directed. |
| 114 | Taking out from trenches or taking down from wall GI steel tubing and connections, 25 mm bore, setting aside andcleaning the serviceable pipe for re-laying/ re-fixing or removal of unserviceable pipe from site of work complete all as specified and as directed |
| 115 | Re-fixing/ Re-laying of old serviceable GI pipes 25 mm bore , obtained from taking out here-in-before, with all new fittings and laid in trenches/wall complete all as specified and as directed |
| 116 | Supply and fixing of25 mm bore GI tubing, medium grade with allnew fittings as required complete fixed to walls and ceilings or laid in floors/trenchesincluding testing complete all as specified and directed. |
| 117 | Supply & Fixing Gun metal, gate valves, with iron wheel head, suitable for 20mm bore dia of pipes,Screwed both ends for iron pipe or for unionincluding taking out old one complete all as specified and as directed. |
| 118 | Supply & Fixing Gun metal, gate valves, with iron wheel head, suitable for 25mm bore dia of pipes,Screwed both ends for iron pipe or for unionincluding taking out old one complete all as specified and as directed. |
| 119 | Supply & Fixing Gun metal, gate valves, with iron wheel head, suitable for 15 mm bore dia of pipes,Screwed both ends for iron pipe or for unionincluding taking out old one complete all as specified and as directed. |
| 120 | S&F in Repair to water level indicator ofOH Reservoirby replacement of PVC float ball, mild steel pulley and flexible steel wire rope fromfloat ball to measuring key and painting to indicator with 2 coat of synthetic enamelpaint and marking number with red/black reflective type colour complete all as specified and as directed. |
| 121 | S&F of 3 Phase Dgitial Panel voltmeter Meter Flush Mounting 96x96mm, Accuracy Class -1 , Input Voltage measurement range 50-520V AC including taking down existing unserviceable one complete all as specified and as directed. |
| 122 | S&F of 3 Phase, 5A, Dgitial Panel Ammeter Flush Mounting 96x96mm, Accuracy Class -1 ,CT/PTSiteprogrammable including taking down existing unserviceable one complete all as specified and as directed. |
| 123 | S&F3 Phase indicator lamp including taking down existing set complete all as specified and as directed by Engr in Charge. |
| 124 | S&FGlow sign board on iron frame with all side 300 GSM GI sheet covering including LED tube light fittings back and front side of backlit banner of size approximately 15 feet x 3 feet with all necessary arrangement for fixing it on pump house installation entrance complete all as specified and directed by Engr-in-Charge |
| 125 | S&Fin repairsingle phase preventor relaySPPR type SDz5, SPPR with Timer 360V in Fully automatic star delta starter by expert Electrician in sheet metal enclosure for 10HP/15HP/20HP motor, complete all as specified and directed by Engr-in-Charge |
| 126 | S & F in repairsMotor protection relayThernmal OL range 0.78-5.2 A for detection of Earth fault, single phase, lock rotor ,over load with selectable trip suitable for and upto 0.37 Kw , 415 V, 3 Phase Motor Starter or as per existing sizecomplete all as specified and as directed. |
| 127 | S & Fas in repairsMotor protection relayThernmal OL range 8-22 A for detection of Earth fault, single phase, lock rotor ,over load with selectable trip suitable for 10 to 20HP, 415 V, 3 Phase Motor Starter or as per existing sizecomplete all as specified and as directed. |
| 128 | S & F 80mm dia mettallic cast iron foot valve at the end of GI pipe/PVC pipe with complete fixing accessories under jackwell/river completeall as specified and directed. |
| 129 | Supply in replacement of gland packing for monoblock motor or sluice valvefor any capacity all as directed by Engr-in-Charge |
| 130 | Supply & Fixing in replacement 20mm bore, ball valves highpressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixedcomplete all as specified and directed. |