Tender For Repair/Maintenance Of Lt Oh Line/ Ug Cable, Lt Panels, Gen Servicing Of Standby Gen Set At Em Installations And Other Connected Works At Abohar And Fazilka Mil Station.; 1 Supply and fix in replacement Hot moulded (FRP) junction box of size 280mm x 200mm for street light pole with locking arrangementwith 32 Amps, 4 way heavy duty terminal block suitable connection for three phase incoming cable three phase outgoing cable and single phase connection for light fittings including MCB SP 10 Amps 01 Nos enclosed in thermoplastic box in closed shock proof safe IP 65, weather, vermin proof, dust and water proof complete with two number cable entryglandof standard size with suitable size mild steel clamps to fix on pole complete all as specified and directed by Engineer-in-Charge. 2 Excavation in trenches, not exc 1.5 m wide and n. exc 1.5 m depth for foundations of poles, struts, stays etc. or layingunderground cable etc.in soft/loose soil,& getting out complete all as specified and directed by Engineer-in-Charge. 3 Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25cm thick complete all as specified and directed by Engineer-in-Charge 4 Removal of excavated surplus material to a distance n. exc. 50 mtr away in layer n. exc. 25cm from the starting point all as direcet by Engr-in-Charge. 5 Supplying and laying un-reinforced precast concrete cable cover, class LV, type -III with peak, size 450 mm x 180mm x 40mm complete all as directed by Engr - in charge 6 Supplying and laying un-reinforced precast concrete cable cover, class LV, type -II,flatPeak, size 300 mm x 180mm x 40mm complete all as directed by Engr - in charge 7 Supplying and laying un-reinforced precast concrete cable cover, class LV, type -I,flatpeak, size 250 mm x 150mm x 40mm complete all as directed by Engr - in charge 8 M & L Sand cushioning, with dry and clean tibba sand (for under ground cable) 8 cm before laying cable and 15 cm after laying and punned to 18 cm after laying of cablecomplete all as specified and as directed.Note:- (i) Punned thickness shall be considered for payment purpose (ii) Approved sand free from vegetations, grass and other deleterious substances shall be used. Note :- For the purpose of payment only punned thickness will be measured 9 Supply and laying double wall corrugated pipe DWC pipe of dia 50/38mm, Non-metallic, resistance to compression : type 450, resistance to impact; normal, resistance to bending: pliable, resistance to external influence; ingress protection: IP 67, resistance against corrosion: without protection, resistance to flame propagation: non flame propagating,conforming to IS-16205 (part-24) 2017 including necessary jointing material i.e snap fit coupler with rubber ring, sealing plug, tees, bend, angel bend etc for passing electrical cable complete all as specified anddirected by Engr - in charge 10 All as per Srl item No. 09 here-in-before but DWC pipe dia 77/63 complete all as specified and directed by Engineer-in-Charge. 11 All as per Srl item No. 09 here-in-before but DWC Pipe dia 90/76 complete all as specified and directed by Engineer-in-Charge. 12 All as per Srl item No. 09 here-in-before but DWC Pipe dia 120/103 complete all as specified and directed by Engineer-in-Charge. 13 M & L for boring hole across the Road/plinth/hard standing by trench less technology method suitable for 100mm bore pipe for 0.4 mpa working pressure for cable passing without damaging Road / Plinth /Floor with 80mm GI pipe complete all as specified and directed by Engineer-in-Charge. 14 Labour and T&P for dismentling of existing pole any size and type, shifting of pole of any type from one place to another place of 5 KM, including providing of suitable vehicle for shifting, including taking down any type of street light with all fitting complete all as specified and directed by Engineer-in-Charge. 15 Supply and fixing bracket made out of GI tubing light grade 25mm dia, 1.5 metre long bent to shape at 120 degree angle at half metre from bottom, including two Nos clamps made out of MS Flat iron of size 25x4 mm with suitable nuts and bolts for holding/fixing of bracket on steel pole including painting to MS clamp and nut bolts with two coats of aluminium paint over a coat of red oxide primer, complete all as specified and directed by Engineer-in-Charge. 16 supply and install steel tabular swaged poles type 410 SP-31 (9.0 meter long) complete with MS base plate of size 300x300x6 mm thick at bottom, welded at centre through hole of 14 mm dia ,height of 14mm dia 300 mm above the coping including painting of poles with two coats of synthetic enamel paintover a coat of primer black and white/yellow strips 30 CM wide each (05 Nos) up to 1.5 meters height from cpoing and numbering of poles complete all as specified and directed by Engineer-in-Charge. 17 M& L for pre stressed concrete pole 9 mtr long 102mm x 172mm at top and 102 x279mm at bottom class 10, including painting of pole in alternate colour of yellow and black upto a height specified as per height specified as per IE rules and marking of pole number by using stencil complete all as directed by engineer-in-charge.Note:-1. Excavation and PCC will measured and paid separately.2. Fornt and letter size for marking of pole number will be as per direction of engineer in charge. 18 Taking out faulty underground LT cable and Relaying of LT cable from 10 sqmm to 400 sqmm 2/3.5/4 core in same or other trenches/wall surfaces/flooring/road and testing on completion including good all disturbed surfaces to match with existing complete all as specified and directed by Engineer-in-Charge.Note : Earth work viz excavation, sand cushioning will be measured and paid seprately. 19 Labour for disconnecting and taking out old unserviceable underground LT Cable of size 6 Sqmm 2 Core alongwith stone patti/ cable cover/bricks/interlocking tiles etc from trenches/ floor/ road /pipe /along poles complete all as specified and directed by Engineer-in-Charge. Note :Excavation, earth workrequired for item shall be measured and paid separately under respective items of BOQ. 20 All as per Srl item No. 19 here-in-before but LT cable of size 6 Sqmm 4 core complete all as specified and directed by Engineer-in-Charge. 21 All as per Srl item No. 19 here-in-before but LT cable of size 10 Sqmm 4 core complete all as specified and directed by Engineer-in-Charge. 22 All as per Srl item No. 19 here-in-before but LT cable of size 16 sqmm 4 core complete all as specified and directed by Engineer-in-Charge. 23 All as per Srl item No. 19 here-in-before but LT cable of size 25 Sqmm 3.5/4 core complete all as specified and directed by Engineer-in-Charge. 24 All as per Srl item No. 19 here-in-before but LT cable of size 35 Sqmm 3.5/4 core complete all as specified and directed by Engineer-in-Charge. 25 All as per Srl item No. 19 here-in-before but LT cable of size 50 Sqmm 3.5 core complete all as specified and directed by Engineer-in-Charge. 26 All as per Srl item No. 19 here-in-before but LT cable of size 70 Sqmm 3.5 core complete all as specified and directed by Engineer-in-Charge. 27 All as per Srl item No. 19 here-in-before but LT cable of size 95 Sqmm 3.5 core complete all as specified and directed by Engineer-in-Charge. 28 All as per Srl item No. 19 here-in-before but LT cable of size 120 Sqmm 3.5 core complete all as specified and directed by Engineer-in-Charge. 29 All as per Srl item No. 19 here-in-before but LT cable of size 150 Sqmm 3.5 core complete all as specified and directed by Engineer-in-Charge. 30 All as per Srl item No. 19 here-in-before but LT cable of size 240 Sqmm 3.5 core complete all as specified and directed by Engineer-in-Charge. 31 Supply, laying, Jointing and testingin trenches or fixing to wall/pole or passing through pipe and and testing XLPE Cable of size 6 Sqmm 2 Core Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor including making good to all disturbed surfaces/flooring/tiling/road to match with existing specifications complete all as specified and directed by Engineer-in-Charge. 32 All as per Srl item No. 31 here-in-before butcable of size 6 Sqmm 4 core complete all as specified and directed by Engineer-in-Charge. 33 All as per Srl item No. 31 here-in-before butcable of size 10 Sqmm 4 core complete all as specified and directed by Engineer-in-Charge. 34 All as per Srl item No. 31 here-in-before butcable of size 16 Sqmm 4 core complete all as specified and directed by Engineer-in-Charge. 35 All as per Srl item No. 31 here-in-before butcable of size 25 Sqmm 4 core complete all as specified and directed by Engineer-in-Charge. 36 All as per Srl item No. 31 here-in-before butcable of size 35 Sqmm 3.5 core complete all as specified and directed by Engineer-in-Charge. 37 All as per Srl item No. 31 here-in-before butcable of size 50 Sqmm 3.5 core complete all as specified and directed by Engineer-in-Charge. 38 All as per Srl item No. 31 here-in-before butcable of size 70 Sqmm 3.5 core complete all as specified and directed by Engineer-in-Charge. 39 All as per Srl item No. 31 here-in-before butcable of size 95 Sqmm 3.5 core complete all as specified and directed by Engineer-in-Charge. 40 All as per Srl item No. 31 here-in-before butcable of size 120 Sqmm 3.5 core complete all as specified and directed by Engineer-in-Charge. 41 All as per Srl item No. 31 here-in-before butcable of size 150 Sqmm 3.5 core complete all as specified and directed by Engineer-in-Charge. 42 All as per Srl item No. 31 here-in-before butcable of size 185 Sqmm 3.5 core complete all as specified and directed by Engineer-in-Charge. 43 All as per Srl item No. 31 here-in-before butcable of size 240 Sqmm 3.5 core complete all as specified and directed by Engineer-in-Charge. 44 All as per Srl item No. 31 here-in-before butcable of size 300 Sqmm 3.5 core complete all as specified and directed by Engineer-in-Charge. 45 Supply only fixing aluminium lugs of size 16 Sqmm complete all as specified and directed by Engineer-in-Charge. 46 All as per Srl item No. 45 here-in-before but lugs of size 25/30 Sqmm complete all as specified and directed by Engineer-in-Charge. 47 All as per Srl item No. 45 here-in-before but lugs of size 50/70 Sqmm complete all as specified and directed by Engineer-in-Charge. 48 All as per Srl item No. 45 here-in-before but lugs of size 95 Sqmm complete all as specified and directed by Engineer-in-Charge. 49 All as per Srl item No. 45 here-in-before but lugs of size 120 Sqmm complete all as specified and directed by Engineer-in-Charge. 50 All as per Srl item No. 45 here-in-before but lugs of size 150 Sqmm complete all as specified and directed by Engineer-in-Charge. 51 All as per Srl item No. 45 here-in-before but lugs of size 240 Sqmm complete all as specified and directed by Engineer-in-Charge. 52 All as per Srl item No. 45 here-in-before but lugs of size 300 Sqmm complete all as specified and directed by Engineer-in-Charge. 53 All as per Srl item No. 45 here-in-before but lugs of size 400 Sqmm complete all as specified and directed by Engineer-in-Charge. 54 Taking down defective LED street light or Flood light or High mask light or Post top lantern LED Light of any capacity viz 10W/20W/25W/30W/60W/ 200W,fitting of any type from their existing position i.e. poles or bldg or pillers or gardens and re-fixing the same after carried out repairs i.e. replacement of LED driver,SPD , PVC wire and any other necessary connecting item and making suitable for lightning purpose, all as specified and directed by Engineer-in-Charge. Note : (i) LED driver, and SPD , 3 core cable will be measured and paid separately under respective items of BOQ.(ii) Cost of nut, bolts & washers for fixing new items is deemed to be included in quoted rate. 55 Supply only LED driver of 25/30/36 watt for LED Street light fitting of type make/model as per sample complete all as specified and directed by Engineer-in-Charge. 56 All as per Srl item No. 55 here-in-before but of size 60W complete all as specified and directed by Engineer-in-Charge. 57 All as per Srl item No. 55 here-in-before but of size 120W complete all as specified and directed by Engineer-in-Charge. 58 All as per Srl item No. 55 here-in-before but of size 200W complete all as specified and directed by Engineer-in-Charge. 59 Repair/ maint of High Mast including servicing of taking up and down mechanism checking of gear & pulley, rope, motor winding, greasing, starter, fitting etc assembly for proper functing and greasing of high light fitting all as directed by Engineer in Charge. 60 Supply and fixing PVC insulated armoured multi strand copper conductor cable 1100 volts grade of size 2.5 Sqmm 10 core alongwith High Mast all as directed by Engineer in charge. 61 S&F cable jointing kit for 1100 V (Earthed) grade cable for outdoor end termination heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 35 sqmm to 50 sqmm complete all as specified and directed by Engineer-in-Charge. 62 S&F cable jointing kit for 1100 V (Earthed) grade cable for outdoor end termination heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 70 sqmm to 95 sqmm complete all as specified and directed by Engineer-in-Charge. 63 S&F cable jointing kit for 1100 V (Earthed) grade cable for outdoor end termination heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 120 sqmm to 300 sqmm complete all as specified and directed by Engineer-in-Charge. 64 S&F cable jointing kit for 1100 V (Earthed) grade cable for straight throughheat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 35 sqmm to 50 sqmm complete all as specified and directed by Engineer-in-Charge. 65 S&F cable jointing kit for 1100 V (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 70 sqmm to 95 sqmm complete all as specified and directed by Engineer-in-Charge. 66 S&F cable jointing kit for 1100 V (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 120 sqmm to 300 sqmm complete all as specified and directed by Engineer-in-Charge. 67 M&L for cutting, trimming of branches along 2 pole/4 pole structure , OH Conductor of LT/HT line within 2 mts distance along both sides of structure /line complete all as directed by Engr-in-Charge. 68 Removal of bushes/plants/shrubs and taking out unsv cable or cover it properly by using cable cover or soil around the water supply or electric supply installation or near LT Panels , inside valve pits and surface excavation not exceeding 15 cm depth levelling the ground, removing excavated material outside the army cantt area complete all as specified and directed by Engr-in-Charge. 69 M&L for preparationold painted surfaces with synthetic enemel paint to LT steel tubbular pole 8.5/9 mtr long including clamps,brackets,chanel,cross arms,bracing support pipe for cable and swan neck etc, including zebra painting at bottom up to 1.5 mtr above from the PCC couping and writing pole No with white paint complete etc complete all as specified and as directed by Engr-In-Charge. Note: Pole number shall be marked with white enamel paint over a base of size 20cmx20cm on prepared with two coats of black enamel paint on pole surfaces. 70 Supply and fix in replacement of GI pipe 40 mm bore light grade for protection of cable including provision of MS clamps, nut, bolts etcrequired for fixing pipe along pole / wall / laid under the road / laid under the floor or in trenches complete all as specified and directred by Engineer-in-Charge. Note: (i) Excavation & earth work shall be measured and paid separately under respectiveitem of this Schedule. 71 M & L for preparation ofold painted surfaces of LT panel size (up to 2.0x1.5mx0.8m) and applying spray painting with two coats of synethetic enamel paint over a coat of red oxide primer of existing color for outdoor/indoor panel board, outer & inner side and scraping out the old paint surfaces of existing panel boards including white wash to panel foundation/PCC basecomplete all as specified and directed by Engr-In-Charge . 72 Supply and fix in replacement of digital Ammeter 0 - 100 Amps complete all as specified and directed by Engineer-in-Charge. 73 Supply and fix in replacement digital Voltmeter 0 - 500 Volts complete all as specified and directed by Engineer-in-Charge. 74 Supply and fix in replacement neon indicating lamp (Red, Yellow, Blue) complete all as specified and directed by Engineer-in-Charge. 75 M & L for MS work as in doors or gates or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering in doors or gates etc. to be prepared for hanging or sliding with and including hooks and hinges or steel hanging door fittings and hanging , fastening and fixing complete as in compound guards of transformers, four pole/two pole structures in sub stations or doors and gates of Panles or DBs incuding painting of two coats of enamel paint over one coat of zinc coatingprimer complete all as specified and directed by Engineer-in-Charge. Note :- Disconnection of cables/wires, repair of broken doors/gates of panels and DBs by necessary welding with painting deemed to be included in rate quoted by contractor. 76 S&F GI strip 32x6 mm with saddles and fixing screws etc. for roof conductors and down conductors above ground or fixed on structure fixed with screws and bend to any shape as required for site complete all as specified and directed by Engineer-in-charge. 77 Earthing complete with galvanised steel earth plate electroe 60 cmx60cm6mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connectedto and including galvanized earth lead GI Strip of size 32x6mm by means of GI bolt/snuts/washers, protected by 40mm bore GI light grade pipe from earth plate & upto 3m long pole fixed with 2 clamp made from mild steel flat iron 32x6mm bolts, nuts, washer etc. earth plate shall be surrounded by alternate layer of charcoal or coke and common salt 15cm thick all around buttom and top of earth plate 20mm dia GI Medium grade pipe for watering and including funnel, wire mesh, RCC cover & frame PCC 1:3:6 type C1 using 20mm graded stone aggregate as in earthing pit including necessary excavation & earth work all as specified & shown on electrical plate No. 3 of SSR Part-I, Note: (i) PCC chamber shall be constructed at least 1.5 mtr away from the earth electrode and pipe for watering shall be provided in slanting manner (ii) earthing for Lightning protection is also included in the above item) 78 Supply and fixing of automatic steet light switch using INFRARED SENSOR based on NATURE SWITCH for automatic switch of street lights nature switch operation should be based on natural light lux level. Required illuminance level for switchning ON is <30 lux and for switching OFF>10 lux. The sensor should also have part night operation facility of minimum 4 hours to maximum 12 hours. The sensor alongwith suitable power contactors, incoming-outing MCBs, Auto-manual (Sensor By Pass) selection option should be enclosed in a pole/ wall mountable enclosure made of rust proof, electric shock proo, termite proof and FR grade SMC junction Box confirming to IP-54 Single phase load of 5KW with contactor 63 Amps, incomingrating 32-40 Amps and circuit wiring minimum 16 Sqmm copper conductor cable complete all as specified and directed by Engineer-in-Charge. 79 Supply and fixing of automatic steet light switch using INFRARED SENSOR based on NATURE SWITCH for automatic switch of street lights nature switch operation should be based on natural light lux level. Required illuminance level for switchning ON is <30 lux and for switching OFF>10 lux. The sensor should also have part night operation facility of minimum 4 hours to maximum 12 hours. The sensor alongwith suitable power contactors, incoming-outing MCBs, Auto-manual (Sensor By Pass) selection option should be enclosed in a pole/ wall mountable enclosure made of rust proof, electric shock proo, termite proof and FR grade SMC junction Box confirming to IP-54 three phase load of 12KW with contactor 75-80 Amps, incomingrating 32-40 Amps and circuit wiring minimum 25 Sqmm copper conductor cable complete all as specified and directed by Engineer-in-Charge. 80 M&L for shifting of pole of any type from one place to another place of 2.5KM, and installation of pole including providing of suitable vehicle for shiftingcomplete all as specified and directed by Engineer-in-Charge.Note : Earth work and PCC to be measured and paid separately under respective items of BOQ. 81 Excavation in trenches in any type of soilexceeding 1.5 mtr deep and notexceeding 3.0 mtr deep and not exceeding 1.5 mtrwide for laying of cables, RCC/Steel tubular poles/staysand struts etc getting outincluding trimmingsides and forming bottom surface complete all as specified and directed by Engineer-in-Charge. 82 M&L for plain cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate in foundation of PCC poles/struts as specified including necessary form work complete all as specified and directed by Engineer-in-Charge. 83 M&L for plain cement concrete 1:3:6 type C-2 using 40mm graded stone aggregate in foundation of stay assembly etc including necessary form work, complete all as specified and directed by Engineer-in-Charge. 84 M&L for plain cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate for coping around poles , including necessary form work finishing even and smooth without using extra cement , complete all as specified and directed by Engineer-in-Charge. 85 Note for BOQ Srl item No. 85 to 92(i) Contractor has to mobilise skilled electrician alongwith helper within 30 minutes of receipt of the complaint to the site for resolving the issue within 2 hrs. If contractor fails to resolve the issue within 2 hrs then penalty of Rs. 1000/- per delay hour will be imposed. Time taken beyond 2 hrs will be counted as delay hrs.(ii) Minor item such as lugs / spreader (copper / aluminium), electrician insulation tap, but bolts, indicator lamp for R Y B phase, electrical wire of single core from size 0.5 sqmm to 10 sqmm upto a length of 01 metre for each job), mounting arrangement of MCCBs / MCBs / Panel meters and other minor misc items for iron / hardware work in case of uneven fitings deemed to be included in quoted rates, in case of any dispute for the same, Garrison Engineer will decide the characterisctics of minor items and his / her decision will be final and binding.(iii) Contractor will arrange necessary tools and plants i.e. ladder, vehicle, electrician tool kit, measuring instruments etc, safety equipments, first aid box with all essential medicines.Labour only for attending the complaints/Job for interruption/defect in LT overhead line / LT UG cable continuity of electric supply in electrical switchgears, LT Panels, feeder pillers, busbars, main switches etcand labour for checking / fixing ACB of any Capacity complete all as specified and directed by Engineer-in-Charge. 86 All as per Srl item No. 85 here-in-before but Labour for checking / fixing of MCCB of any capacity complete all as specified and directed by Engineer-in-Charge. 87 All as per Srl item No. 85 here-in-before but Labour for checking / fixing of MCB of any capacity complete all as specified and directed by Engineer-in-Charge. 88 All as per Srl item No. 85 here-in-before but Labour for checking / fixing of Panel meter/LT Over Head/LT UG Cable of any type & capacity complete all as specified and directed by Engineer-in-Charge. 89 All as per Srl item No. 85 here-in-before but Labour for Rewiring of LT panel, dressing/insulating exposed busbars & wiring, tightning of all nut bolts of bus bars connecting point etc except incoming and outgoing LT cable complete all as specified and directed by Engineer-in-Charge. 90 All as per Srl item No. 85 here-in-before but Labour for Internal cleaning for dust/spider web complete all as specified and directed by Engineer-in-Charge. 91 All as per Srl item No. 85 here-in-before but Labour for dressing and insulating of exposed parts of incoming/outgoing LT cable end terminating joint 3.5/4 core of any capacity/type including reconnecting the same to circuit and making of incoming/outgoing feeder detail on cable byusing appropriate stencil and colour complete all as specified and directed by Engineer-in-Charge. 92 All as per Srl item No. 85 here-in-before but Labour for Welding/bazing for door/hinges/lock etc. complete all as specified and directed by Engineer-in-Charge. 93 Taking downcare fully existingout door/indoor type Old PCC floor mounted LT panel board of size(moe than 1.0m,x1.0mx0.5m to 2.0x1.5mx0.8m) after disconnecting all type of incoming and out going cables, removing carefully switch gears and measuring instruments for reuse/refixing of serviceable items and repair/maint and servicing of existing panel by replacing hinges,switch gear compartments with rubber sheal,locks, nuts,bolts and washers and provn of danger notice boards, indicators of three nos with colour coding and three phase digital voltmeter 0-500V, Ammeter 0-800A with suitable CT,s and selector switch and tape insulation sleeves the three phases and neautral with colour coading and painted with two coats powder coating primer and also reconnecting all cables in same position with suitable glands,gland plates,aluminium lugs, nut bolts and washers.Refixing serviciable switchgears obtained from the panel. Note: Supply and fix of Switch gears against unserviceable will be measured and paid separately with relevent items of this schedule. 94 Supply and fix , in repair Solar Charger Controller withLED driver, Battery charging-operating voltage 10.9-14.4 V,Solar panel voltage 18 V,Power max 100wp battery voltage 12.8V, Charging current 10Amp,battery type LiFe Po4, Charging efficiency 90% Constant Current Driver I/P Voltage (vdc) -12.8,V I/P Current -2.34A,I/P Power 30W, O/P Volatage (vdc) 17.5V , O/P Current -1.54A, O/P Power -27.6W, Efficiency 90% ,IP 65, Product Code : CGSAMC12V10-30complete all as specified and directed by Engineer-in-Charge. 95 Supply and fix , in repair Hybrid Solar Smart Switch , IP-65, HYSS12V-10A, LIEP1UC26complete all as specified and directed by Engineer-in-Charge. 96 S & F Integral LED aviation light comprising of aluminium housing with polycarbonate enclosure complete all as specified and directed by Engineer-in-Charge. 97 S&F in replacement of pin type,porcelain,vitreous,white,brown or green insulator including one galvanised mild steel spindle,two galvanised iron washers and one galvanised iron nut, 100 mm height,65 mm dia for 1100 volts grade complete all as specified and directed by Engineer-in-Charge. 98 S&F in replacement of shackle type,porcelain,vitreous,white,brown or green insulator 1100 Volts LT of size 100 mm high and 115 mm dia including galvanised mild steel straps of size 31x5 mm,washers,insulator bolts 14 mm dia,washers and nuts etc complete all as specified and directed by Engineer-in-Charge. 99 S&F in repair loop type insulator, vitrous porcelain, white brown or green small size with overall dimensions 65x90 mm clearance of hole 16 mm dia complete all as specified and directed by Engineer-in-charge. 100 Supply and fix inreplacement of cradles,hexagonal/rectangular,fabricated with Galvanised steel wire 3.15 mm or 4 mm dia, for LT/HT guard wire and craddles of required size or span complete all as specified and directed by Engineer-in-charge. 101 Suuply and fixing on load change over switches 4 pole,3 ph,50 HZ, 415 Vin sheet steel enclosure of 160 amps complete all as specified and directed by Engineer-in-Charge. 102 Suuply and fixing on load change over switches 4 pole,3 ph,50 HZ, 415 Vin sheet steel enclosure of 200 amps complete all as specified and directed by Engineer-in-Charge. 103 Suuply and fixing on load change over switches 4 pole,3 ph,50 HZ, 415 Vin sheet steel enclosure of 250 amps complete all as specified and directed by Engineer-in-Charge. 104 Suuply and fixing on load change over switches 4 pole,3 ph,50 HZ, 415 Vin sheet steel enclosure of 400 amps complete all as specified and directed by Engineer-in-Charge. 105 Supply,install, testing andcommissioning of CPRI approved, factory made, LT panel board cubical, outdoor, type, floor mounted double door, 3 phase, 4 wire 50 Hz, 415 volts . The panel board size 1.2 X 1.2 X 0.6 mtr shall be made 3.15 mm thick CRCAsheet load bearing members and 16 SWG (1.6 mm thick) for door covers and internal portionsshall be powder coted both sides. Base frame of the panel shall be made of ICMC channel of size 50X50X6 mm, duly grouted onplateform made of brick work in CM (1:2:4), 15 mm thick plastering in CM (1:6) having minimum height 600 mm. The panel shall be provided with separate compartment of each switch gears with hinged door, includinginter locking with switch gears. The panle board shall be suitable for AC, 415 volts, 50Hz, 3 Phase, 4 Wire supply completed with epoxy coated (400 Amp) rated high conductivity Aluminium bus bar ( double set -08 NOs ie one set for Main supply incomming only , another set for change over incomming)supported with DMC/ AMC barriers and colour coated heat shirnkable sleve and F class insulator pre-wired with copper cable, 1100 volts of danger notice board on front of the panel and degree of protection is IP 54. The panel shall be complete with illustraction such as LED phase indicating lamps and CTs including external aluminium strip of rating of incommer (200 AMP,incl 02 Nos change over switch each 250A) and outgoing as per rating of MCCBs including aluminium legs to connected the cable etc. Note:- 1. Design/ drawing / bom of the panel board showing the dimension incl accessories is to beobtained from panel board manufacturer / supplied and same is to be got approved from GE before placing final order to the manufacturer / suppliers. 2. Anything missing out in the technical specification but technically required for efficient working is deemed to be included in qouted rates. 106 Supply,install, testing andcommissioning of CPRI approved, factory made, LT panel board cubical, outdoor, type, floor mounted double door, 3 phase, 4 wire 50 Hz, 415 volts . The panel board size 1.2 X 1.2 X 0.6 mtr shall be made 3.15 mm thick CRCAsheet load bearing members and 16 SWG (1.6 mm thick) for door covers and internal portionsshall be powder coted both sides. Base frame of the panel shall be made of ICMC channel of size 50X50X6 mm, duly grouted onplateform made of brick work in CM (1:2:4), 15 mm thick plastering in CM (1:6) having minimum height 600 mm. The panel shall be provided with separate compartment of each switch gears with hinged door, includinginter locking with switch gears. The panle board shall be suitable for AC, 415 volts, 50Hz, 3 Phase, 4 Wire supply completed with epoxy coated (400 Amp) rated high conductivity Aluminium bus bar ( double set -08 NOs ie one set for Main supply incomming only , another set for change over incomming)supported with DMC/ AMC barriers and colour coated heat shirnkable sleve and F class insulator pre-wired with copper cable, 1100 volts of danger notice board on front of the panel and degree of protection is IP 54. The panel shall be complete with illustraction such as LED phase indicating lamps and CTs including external aluminium strip of rating of incommer (200 AMP,incl 02 Nos change over switch each 250A) and outgoing as per rating of MCCBs including aluminium legs to connected the cable etc. Note:- 1. Design/ drawing / bom of the panel board showing the dimension incl accessories is to beobtained from panel board manufacturer / supplied and same is to be got approved from GE before placing final order to the manufacturer / suppliers. 2. Anything missing out in the technical specification but technically required for efficient working is deemed to be included in qouted rates. 107 M&L for monthly Check Inspection of DG sets of capacity 320 KVA (Make : Mahindra) including alternator, electric panel board connection to DG set etc for smooth functioning and carrying out maintanance as required at site and directed by Engr-in Charge. Note: Items/ Spares required shall be measured and paid separately under respective item of BoQi) Checking engine oil level and topping up as and when required. ii) Checking and adjusting the belt for tension and replacement of belt if required.iii Checking of oil bath air cleaner level.iv) Checking of exhaust system for leakagev) Draining of sediment from fuel filter and fuel tankvi) Cleaning of air cleaner elementsvii) Checking engine alternator coupling, mounting bolts and alignmentviii) Tighting all nuts, bolts, in altenator terminal blockix) Checking of alternator carbon brushes and connections in alternator.x) Checking and tightening of all connection in DC control wiring.xi) Checking of all radiator rubber hoses for leakage and replacement if required.xii) Checking and recording oil pressure, water and oil temperarute for smooth functioning.xii) Checking anti vibration mounting pads for any deformation.xiii) Checking throttle linkage for smooth operation.xiv) Checking battery for cell test, electrolyte level, gravity and topping up to required levelxv) Routine check / repair work of panel, switches, MCCBs, main switch, all contactors, engine control unit etc.xvi) Checking of AMF panel, all electrical connections etc.xvii) Checking of earthing resistancexviii) Cleaning of vegitation around the DG set up to 1.5 mtr area.monthly Check Service shall be carried out as described 108 All as per Srl item No. 107 here-in-before but DG Set Capacity 200 KVA, Make : Crompton Greaves / Kirloskar complete all as specified and directed by Engineer-in-Charge. 109 All as per Srl item No. 107 here-in-before but DG Set Capacity 160 KVA, Make : Kirloskar complete all as specified and directed by Engineer-in-Charge. 110 All as per Srl item No. 107 here-in-before but DG Set Capacity 125 KVA, Make : Ashok Leyland/ Mahindra complete all as specified and directed by Engineer-in-Charge. 111 All as per Srl item No. 107 here-in-before but DG Set Capacity 100 KVA, Make : Kirloskarcomplete all as specified and directed by Engineer-in-Charge. 112 All as per Srl item No. 107 here-in-before but DG Set Capacity 75 KVA, Make : Kirloskar complete all as specified and directed by Engineer-in-Charge. 113 All as per Srl item No. 107 here-in-before but DG Set Capacity 63 KVA, Make : Kirloskar & CG complete all as specified and directed by Engineer-in-Charge. 114 All as per Srl item No. 107 here-in-before but DG Set Capacity 40 KVA, Make : Ashok Leyland complete all as specified and directed by Engineer-in-Charge. 115 All as per Srl item No. 107 here-in-before but DG Set Capacity 30 KVA, Make : Ashok Leyland & Kirloskar complete all as specified and directed by Engineer-in-Charge. 116 All as per Srl item No. 107 here-in-before but DG Set Capacity 20/25 KVA, Make : Ashok Leyland & Kirloskar complete all as specified and directed by Engineer-in-Charge. 117 All as per Srl item No. 107 here-in-before but DG Set Capacity 15 KVA, Make : Kirloskar & Ashok Leyland complete all as specified and directed by Engineer-in-Charge. 118 All as per Srl item No. 107 here-in-before but DG Set Capacity 05 KVA, Make : CG complete all as specified and directed by Engineer-in-Charge. 119 M&L for B Check once in Six month OR 250 Hrs running whichever is earlier for DG sets of capacity 320 KVA (Make : Mahindra). Inspection, maintenance and serviceing including alternator, electric panel board connection to DG set etc for smooth functioning and carrying out maintenance as per OEM instructions and as directed by Engr-in-Charge. Note:Items/ Spares including B Check kit, coolent, lubricating oilrequired shall be measured and paid separately under respective item of BoQi) Repeat the activities of Á Check servicesii) Replacment of lubricant oil. iii) Replacing lubricant oil filters element with O ringsvi) Replacing fuel filters element with O ringsv) Replacing air filter elements with O ringsvi) Replacing coolant.B Check Service shall be carried out as described 120 All as per Srl item No. 119 here-in-before but DG Set Capacity 200 KVA, (Make : Crompton Greaves) complete all as specified and directed by Engineer-in-Charge. 121 All as per Srl item No. 119 here-in-before but DG Set Capacity 160 KVA, (Make : Kirloskar) complete all as specified and directed by Engineer-in-Charge. 122 All as per Srl item No. 119 here-in-before but DG Set Capacity 125 KVA, (Make : Ashok Leyland) complete all as specified and directed by Engineer-in-Charge. 123 All as per Srl item No. 119 here-in-before but DG Set Capacity 100 KVA, (Make : Kirloskar) complete all as specified and directed by Engineer-in-Charge. 124 All as per Srl item No. 119 here-in-before but DG Set Capacity 75 KVA, (Make : Kirloskar) complete all as specified and directed by Engineer-in-Charge. 125 All as per Srl item No. 119 here-in-before but DG Set Capacity 63 KVA, (Make : Kirloskar & CG) complete all as specified and directed by Engineer-in-Charge. 126 All as per Srl item No. 119 here-in-before but DG Set Capacity 40 KVA, (Make : Ashok Leyland) complete all as specified and directed by Engineer-in-Charge. 127 All as per Srl item No. 119 here-in-before but DG Set Capacity 30 KVA, (Make : Ashok Leyland & Kirloskar) complete all as specified and directed by Engineer-in-Charge. 128 All as per Srl item No. 119 here-in-before but DG Set Capacity 20/25 KVA, (Make : Ashok Leyland & Kirloskar) complete all as specified and directed by Engineer-in-Charge. 129 All as per Srl item No. 119 here-in-before but DG Set Capacity 15 KVA, (Make : Kirloskar & Ashok Leyland) complete all as specified and directed by Engineer-in-Charge. 130 All as per Srl item No. 119 here-in-before but DG Set Capacity 05 KVA, (Make : CG) complete all as specified and directed by Engineer-in-Charge. 131 Supply only B check kit for DG set of capacity 320 KVA, (Make : Mahindra). Note : It includes oil filters, Diesel filters and Air filters inner and outer as recommended by OEM complete all as specified and directed by Engineer-in-Charge. 132 All as per Srl item No. 131 here-in-before but DG Set Capacity 200 KVA, (Make : Crompton Greaves) 133 All as per Srl item No. 131 here-in-before but DG Set Capacity 160 KVA, (Make : Kirloskar) 134 All as per Srl item No. 131 here-in-before but DG Set Capacity 131 KVA, (Make : Ashok Leyland) 135 All as per Srl item No. 131 here-in-before but DG Set Capacity 63 KVA, (Make : Kirloskar & CG) 136 All as per Srl item No. 131 here-in-before but DG Set Capacity 40 KVA, (Make : Ashok Leyland) 137 All as per Srl item No. 131 here-in-before but DG Set Capacity 30 KVA, (Make : Ashok Leyland & Kirloskar) 138 All as per Srl item No. 131 here-in-before but DG Set Capacity 15 KVA, (Make : Kirloskar & Ashok Leyland) 139 All as per Srl item No. 131 here-in-before but DG Set Capacity 05 KVA, (Make : CG) 140 Supply only fuel flexible pipe 1, 1/4 to 3/8 PVC best quality complete as per existing make and model complete all as specified and directed by Engineer-in-Charge. 141 Supply only coolant anti freeze for diesel engine generator complete all as specified and directed by Engineer-in-Charge. 142 Supply only Battery distilled water with electrolyte mix complete all as specified and directed by Engineer-in-Charge. 143 Supply only Engine oil 15W-40 for diesel engine generator complete all as specified and directed by Engineer-in-Charge. 144 Supply only radiator hose pipe set with clamps suitable for DG set of capacity 5 to 15 KVA complete all as specified and directed by Engineer-in-Charge. 145 Supply only radiator hose pipe set with clamps suitable for DG set of capacity 30to 63 KVA complete all as specified and directed by Engineer-in-Charge. 146 Supply only radiator hose pipe set with clamps suitable for DG set of capacity 100 to 200 KVA complete all as specified and directed by Engineer-in-Charge. 147 Supply only radiator hose pipe set with clamps suitable for DG set of capacity 320 KVA complete all as specified and directed by Engineer-in-Charge. 148 Supply only fan belt set suitable for 5 to 15 KVA DG Set complete all as specified and directed by Engineer-in-Charge.. 149 Supply only fan belt set suitable for 30 to 63 KVA DG Set complete all as specified and directed by Engineer-in-Charge. 150 Supply only fan belt set suitable for 100 to 200 KVA DG Set complete all as specified and directed by Engineer-in-Charge. 151 Supply only fan belt set suitable for 320 KVA DG Set complete all as specified and directed by Engineer-in-Charge. 152 Supply and fixing in replacement of battery lead with Negative & Positive brass terminals of suitable size and length of each lead complete all as specified and directed by Engineer-in-Charge. 153 Servicing & Repair to self starter of DG set of 05 KVA to 100 KVA 12 volt system incl replacement of parts such as Armature winding, washer, nut, bolts, bush, solonoid, rotor etc. assembling and testing complete all as directed by Engr-in-Charge. 154 Servicing & Repair to self starter of DG set of 125 KVA to 320 KVA 12/24 volt system incl replacement of parts such as armature winding, washer, nut, bolts, bush, solonoid, rotor etc. assembling and testing complete all as directed by Engr-in-Charge. 155 Supply & Fix in replacement of battery 12 V, 80 AH, maintenance free battery, 12 Volt initially charged with suitable size of copper leads and brass terminals complete as directed by Engr-in-Charge. 156 M & L for complete checking of AMF panel, finding the fault, servicing complete including replacement of unserviceable spares with necessary wiring and testing complete for manual & Auto operations all as directed.Note:- Items required for replacement will be measured & paid seperately under respective item of BoQ 157 Supply only in replacement of AMF panel under/over voltage timing relay/ timer relay/ relay card 12 V DC as per existing type, make and capacity complete all as specified and directed by Engineer-in-Charge. 158 M&L for replacement of unserviceable contactor 220 V AC supply, 4 pole suitable for DG Set of 320 KVA AMF panel complete all as specified and directed by Engineer-in-Charge. 159 All as per Srl item No. 158 here-in-before but DG set 200 KVA complete all as specified and directed by Engineer-in-Charge. 160 All as per Srl item No. 158 here-in-before but DG set 125 KVA complete all as specified and directed by Engineer-in-Charge. 161 All as per Srl item No. 158 here-in-before but DG set 100 KVA complete all as specified and directed by Engineer-in-Charge. 162 All as per Srl item No. 158 here-in-before but DG set 75/63/40 KVA complete all as specified and directed by Engineer-in-Charge. 163 All as per Srl item No. 158 here-in-before but DG set 30 KVA complete all as specified and directed by Engineer-in-Charge. 164 All as per Srl item No. 158 here-in-before but DG set 15/5 KVA complete all as specified and directed by Engineer-in-Charge. 165 M&L in replacement of selector switch with elements for controlling Auto/ Manual position of AMF panel of any make and capacity complete all as specified and directed by Engineer-in-Charge. 166 M&L in replacement of Start/ Stop switch with elements of AMF panel of any make and capacity complete all as specified and directed by Engineer-in-Charge. 167 M&L in replacement of Volt meter digital type of range 0-500 volts of AMF panelcomplete all as specified and directed by Engineer-in-Charge. 168 M&L in replacement of Amp meter digital type of existing make, model and capacity of AMF panel complete all as specified and directed by Engineer-in-Charge. 169 M&L in replacement of battery charger 12 V DC SMPS 10 Amp for AMF panel complete all as specified and directed by Engineer-in-Charge. 170 M&L in replacement of battery charger 24 V DC SMPS 10 Amp for AMF panelcomplete all as specified and directed by Engineer-in-Charge. 171 M&L in replacement of AMF panel control unit (Micro processor based AMF module) incorporating controller of supply and restoring times, automatic start/stop/logic & fails to start locknut, mains/gen voltage, Fz sensing as per existing type, make and capacity complete all as specified and directed by Engineer-in-Charge. 172 M & L for repair and replacement of broken conopy door hinges of DG set ofany capacity and make. Setting of conopy door, properly locking arrengement complete all as directed by Engr-in Charge 173 Labour only for attending complaint in case of shutdown/Emergency situation of DG set with AMF Panel carried out by manufactures authorised mechanic without any delay to check the DG set and findout the defect and rectifying it for smooth functiong as directed by Engr-in-Charge.Note: (i) Penality of Rs 1000/- per delay hour will be imposed in case of delay in attending complaint. Time taken beyond 3 hrs will be counted as delay hrs. (ii) Material/ spares required during attending complaint will be measured and paid separetly. 174 M&L for providing Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not lessthan 1.5 metres below normal ground level, connected to galvanised earth strip 25X4 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point including GI pipe 40mm dia for protrction of earth lead, necessary excavation/earth work in any type of soil with wire mesh and watering pipe 20mm dia, PCC pit with Cover complete including testing on completion. 175 S&F ON load changeover switches(Outdoor type) 4 pole 415 Volts of capacity 63 Amps complete taking down old u/s and making necessary connection including all provision for fixing in wall/panel as existing complete all as specified and directed by Engineer-in-Charge. 176 All as per item no. 175 but for 125 Amps capacity complete all as specified and directed by Engineer-in-Charge. 177 All as per item no. 175 but for 160 Amps capacity complete all as specified and directed by Engineer-in-Charge. 178 All as per item no. 175 but for 160 Amps capacity complete all as specified and directed by Engineer-in-Charge. 179 M & L for aluminium overhead conductor steel reinforcedcomplete all as specified and directed by Engineer-in-Charge.