}

Tender For Repair /Maintenance Of Water Supply Installation Including Pumps, Starter, Panel Distribution At Icgs Kakinada, Malkapuram, Jetty Complex And Fire Alarm System And Fire Fighting System Including Allied Works At Icgs Malkapuram Under Ge(I)(, visakhapatnam-Andhra Pradesh

Military Engineer Services has published Tender For Repair /Maintenance Of Water Supply Installation Including Pumps, Starter, Panel Distribution At Icgs Kakinada, Malkapuram, Jetty Complex And Fire Alarm System And Fire Fighting System Including Allied Works At Icgs Malkapuram Under Ge(I)(. Submission Date for this Tender is 23-09-2025. Water Supply Tenders in visakhapatnam Andhra Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

50974938
Tender For Repair /Maintenance Of Water Supply Installation Including Pumps, Starter, Panel Distribution At Icgs Kakinada, Malkapuram, Jetty Complex And Fire Alarm System And Fire Fighting System Including Allied Works At Icgs Malkapuram Under Ge(I)(
Tender
Indian
Andhra Pradesh
Visakhapatnam
23-09-2025

Tender Details

Repair /Maintenance Of Water Supply Installation Including Pumps, Starter, Panel Distribution At Icgs Kakinada, Malkapuram, Jetty Complex And Fire Alarm System And Fire Fighting System Including Allied Works At Icgs Malkapuram Under Ge(I)(Cg)Vizag; 1 Excavating in trenches, n exc 1.5 m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, in cable tench etc. n exc 10 sqm on plan and getting out soft / loose soil complete all as directed. 2 Returning, filling in incl spreading, leveling, watering and well ramming in layers n exc 25 cm complete all as specified & directed. 3 Removing excavated material to a distance n exc 50 mtr and depositing where directed at a level n exc 1.50 mtr above the starting point complete all as specified & directed. 4 M & L for sand cushioning under trenches as in cable protection complete all as specified and directe.(Note: Punned thickness shall measured for payment purpose) 5 Supplying and laying reinforced precastconcrete cable cover, Class LV, Type I,flat,size 250mm x 150mm x 40mm complete all as specified & directed. 6 Taking up or down 20 mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and directed. 7 Taking up or down 25 mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and directed. 8 Taking up or down 40 mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and directed. 9 Taking up or down 50 mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and directed. 10 Taking up or down 80 mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and directed. 11 Taking up or down 100 mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and directed. 12 S&F 20mm bore steel water tubing medium grade galvanized with all fitting, laid in trenches complete all as specified and directed. 13 S&F 25mm bore steel water tubing medium grade galvanized with all fitting, laid in trenches complete all as specified and directed. 14 S&F 40mm bore steel water tubing medium grade galvanized with all fitting, laid in trenches complete all as specified and directed. 15 S&F 50mm bore steel water tubing medium grade galvanized with all fitting, laid in trenches complete all as specified and directed. 16 S&F 80mm bore steel water tubing medium grade galvanized with all fitting, laid in trenches complete all as specified and directed. 17 S&F 100mm bore steel water tubing medium grade galvanized with all fitting, laid in trenches complete all as specified and directed. 18 S&F90 mm outer dia 3-layer PP-R (Polypropylene random copolymer) concealed pipesSDR 7.4 (PN16) UVstabilized andantimicrobial fusionwelded havingthermal stability forhot & cold watersupply includingall PP-R plain &brass threadedpolypropylenerandom fittingslaid in trenches including taking down old unserviceable pipe complete all as specified and directed. 19 S&F110 mm outer dia 3-layer PP-R (Polypropylene random copolymer) concealed pipesSDR 7.4 (PN16) UVstabilized andantimicrobial fusionwelded havingthermal stability forhot & cold watersupply includingall PP-R plain &brass threadedpolypropylenerandom fittingslaid in trenches including taking down old unserviceable pipe complete all as specified and directed. 20 S&F50 mm outer dia 3-layer PP-R (Polypropylene random copolymer) concealed pipesSDR 7.4 (PN16) UVstabilized andantimicrobial fusionwelded havingthermal stability forhot & cold watersupply includingall PP-R plain &brass threadedpolypropylenerandom fittingslaid in trenches including taking down old unserviceable pipe complete all as specified and directed. 21 S&F40 mm outer dia 3-layer PP-R (Polypropylene random copolymer) concealed pipesSDR 7.4 (PN16) UVstabilized andantimicrobial fusionwelded havingthermal stability forhot & cold watersupply includingall PP-R plain &brass threadedpolypropylenerandom fittingslaid in trenches including taking down old unserviceable pipe complete all as specified and directed. 22 S&F25 mm outer dia 3-layer PP-R (Polypropylene random copolymer) concealed pipesSDR 7.4 (PN16) UVstabilized andantimicrobial fusionwelded havingthermal stability forhot & cold watersupply includingall PP-R plain &brass threadedpolypropylenerandom fittingslaid in trenches including taking down old unserviceable pipe complete all as specified and directed. 23 S&F 32 mm outer dia CPVC pipes SDR 11 & plain SDR 11 including all fittings onwalls(conceled) & ceiling or laid in floors for internal water supply including taking down old unserviceable pipe complete all as specified and directed. 24 S&F 40 mm outer dia CPVC pipes SDR 11 & plain SDR 11 including all fittings onwalls(conceled) & ceiling or laid in floors for internal water supply including taking down old unserviceable pipe complete all as specified and directed. 25 S&F 50 mm outer dia CPVC pipes SDR 11 & plain SDR 11 including all fittings onwalls(conceled) & ceiling or laid in floors for internal water supply including taking down old unserviceable pipe complete all as specified and directed. 26 Supply and laying in repair 32mm bore dia High density polyethylene pipes (HDPE) of pressure rating 6 kgf/cm2 fixed complete to walls, ceilings or in floors etc complete including necessary accessaries complete all as specified and directed. 27 Supply and laying in repair 40mm bore dia High density poly ethylene pipes (HDPE) of pressure rating 6 kgf/cm2 fixed complete to walls, ceilings or in floors etc complete including necessary accessaries complete all as specified and directed. 28 Supply and laying in repair 50mm bore dia High density poly ethylene pipes (HDPE) of pressure rating 6 kgf/cm2 fixed complete to walls, ceilings or in floors etc complete including necessary accessaries complete all as specified and directed. 29 Supply, laying and testing of XLPE Insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16.00 sq mm 4 core shall be laid under trench or pipe or loop or shall be fixed on wall / pole including taking out old unserviceable cable complete all as specified and directed.(Note: Earthwork , excavation, sand coushioning, GI pipe etc. shall be measured and paid separately uinder relevant item) 30 Supply, laying and testing of XLPE Insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25.00 sq mm 3.5 core shall be laid under trench or pipe or loop or shall be fixed on wall / pole including taking out old unserviceable cable complete all as specified and directed.(Note: Earthwork , excavation, sand coushioning, GI pipe etc. shall be measured and paid separately uinder relevant item) 31 S&F high quality PVC flexible pipe of 20mm dia complete all as specified and directed. 32 S&F in repair cast iron Non Return valve 150 mm dia, heavy duty, confirming to IS 5312-(Part I) - 1984 complete all as specified & directed 33 S&F in repair cast iron Non Return valve 100 mm dia, heavy duty, confirming to IS 5312-(Part I) - 1984 complete all as specified & directed 34 S&F in repair cast iron Non Return valve 80 mm dia, heavy duty, confirming to IS 5312-(Part I) - 1984 complete all as specified & directed 35 S&F in repair cast iron Non Return valve 25 mm dia, heavy duty, confirming to IS 5312-(Part I) - 1984 complete all as specified & directed 36 S&F in repair cast iron Foot valve of 80 mm dia confirming to IS 4038 1986 complete all as specified & directed 37 S&F in repair cast iron Foot valve of 100 mm dia confirming to IS 4038 1986 complete all as specified & directed 38 S&F in repairs 25 mm bore dia ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed. 39 S&F in repairs 20 mm bore dia ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed. 40 S&F in repairs Disc Filter (Plastic Body) for garden sprinkler system made of durable non-corrosive polymer suitable for water filtration as exisitng complete all as specified and directed. 41 Supply and laying and testing submersible flat, PVC insulated,heavy duty, copper electric cable 6 Sqmm 3 core screened pvc bedded, 1100 Voltgrade laidin borewell complete from starter to submersible pump including taking out old unserviceable/burnt cable complete all as specified and directed 42 Supply and laying and testing submersible flat, PVC insulated,heavy duty, copper electric cable 4 Sqmm 3 core screened pvc bedded, 1100 Voltgrade laidin borewell complete from starter to submersible pump including taking out old unserviceable/burnt cable complete all as specified and directed 43 Taking down carefully Exhaust fan of Squirrel cage induction motortype 300mm Sweep from existing location carrying out rewinding with super enamelled copper wire, replacement bearing, painting, cleaning and servicing and refixing in existing / new location including making electric connection with PVC insulated copper conductor cable from fan to ceiling rose complete all as specified and directed. 44 M & L for preparation of surface of pump/ motor upto 50 HP including removal of dust, rust, grease, and old paint using appropriate tools and solvents and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed. 45 M & L for preparation of surface of pump/ motor upto 10 HP including removal of dust, rust, grease, and old paint using appropriate tools and solvents and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed. 46 M & L for preparation of surface of pump/ motor upto 05 HP including removal of dust, rust, grease, and old paint using appropriate tools and solvents and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed. 47 Supply and fix in repairs 150 mm dia cast iron Sluice Valve, Class PN 1.6, confirming to IS14846 of 2000 with iron wheel head complete all as specified and directed. 48 Supply and fix in repairs 100 mm dia cast iron Sluice Valve, Class PN 1.6, confirming to IS14846 of 2000 with iron wheel head complete all as specified and directed. 49 S&F in repair 80 mm dia cast iron Sluice Valve, Class PN 1.6, confirming to IS14846 of 2000 with iron wheel head complete all as specified and directed. 50 S & F in repairs50 mm dia Gun Metal, globe or Gate Valve with Iron wheel head Screwed both ends for Iron Pipe and fixed complete all as specified and directed. 51 S & F in repairs40 mm dia Gun Metal, globe or Gate Valve with Iron wheel head Screwed both ends for Iron Pipe and fixed complete all as specified and directed. 52 S & F in repairs25 mm dia Gun Metal, globe or Gate Valve with Iron wheel head Screwed both ends for Iron Pipe and fixed complete all as specified and directed. 53 S & F in repairs20 mm dia Gun Metal, globe or Gate Valve with Iron wheel head Screwed both ends for Iron Pipe and fixed complete all as specified and directed. 54 S & F in repairs15 mm dia Gun Metal, globe or Gate Valve with Iron wheel head Screwed both ends for Iron Pipe and fixed complete all as specified and directed. 55 M & L for Disconnecting of a mono-block / submercible pump of capacity up to 5 HP from all electric and water supply connection, lifting from existing position as required, transportation to the workshop, rewinding of the motor with appropriate gauge super enamelled copper wire, thoroughly insulation testing, reassembling, and refixing the pump to the same location with proper alignment and electrical connections complete all as specified and directed. 56 M & L for Disconnecting of a mono-block / submercible pump pump of capacity up to 10 HP from all electric and water supply connection, lifting from existing position as required,transportation to the workshop, rewinding of the motor with appropriate gauge super enamelled copper wire, thoroughly insulation testing, reassembling, and refixing the pump to the same location with proper alignment and electrical connections complete all as specified and directed. 57 M & L for Disconnecting of a mono-block / submercible pump of capacity up to 50 HP from all electric and water supply connection, lifting from existing position as required, transportation to the workshop, rewinding of the motor with appropriate gauge super enamelled copper wire, thoroughly insulation testing, reassembling, and refixing the pump to the same location with proper alignment and electrical connections complete all as specified and directed. 58 S & F in repair Direct-On-Line (DOL) starter, Single phase for submersible pump control complete as specified and directed. 59 S&F in repair Direct-On-Line (DOL) starter, Three phase for submersible pump control complete as specified and directed. 60 S&F in repair Star Delta starter for Motor Pump for up to 5 HP Capacity including 3 phase prventer complete all as specified and as directed . 61 Dismantling damage and broken valve chamber of size 1200x1200x900mm, internal dimension, including U/S rusted MS cover complete without disturbing the existing pipe lines valves and providing valve chamber including necessary excavation and earth work in any type of soil, returning filling, removal of surplus soil n.exc. 50m distance, 100 mm thickPCC 1:4:8 type D2 (using 40mm graded stone aggregate) with 100 mm projection all around, full brick thick brick work in CM (1:6), 10mm thick internal plastering and 15mm thick external plastering upto 150 mm below ground level in CM (1:4), 50 mm thick PCC 1:2:4 type B-1 coping shall be laid over the masonary wall, 6mm thick MS sheet cover with hinges and locking arrangements fixed to angle iron frame made out of 50 x50x6mm MS angle iron with 2 coat of synthatic enameled paint over a coat of red oxied on all exposed steel surface and 2 coats of white washing on plastered surface of valve chamber complete all as specified and as directed . 62 Dismantling damage and broken valve chamber of size 900x900x900mm, internal dimension, including U/S rusted MS cover complete without disturbing the existing pipe lines valves and providing valve chamber including necessary excavation and earth work in any type of soil, returning filling, removal of surplus soil n.exc. 50m distance, 100 mm thickPCC 1:4:8 type D2 (using 40mm graded stone aggregate) with 100 mm projection all around, full brick thick brick work in CM (1:6), 10mm thick internal plastering and 15mm thick external plastering upto 150 mm below ground level in CM (1:4), 50 mm thick PCC 1:2:4 type B-1 coping shall be laid over the masonary wall,6mm thick MS sheet cover with hinges and locking arrangements fixed to angle iron frame made out of 50 x50x6mm MS angle iron with 2 coat of synthatic enameled paint over a coat of red oxied on all exposed steel surface and 2 coats of white washing on plastered surface of valve chamber complete all as specified and as directed . 63 Dismantling damage and broken valve chamber of size 750x750x750mm, internal dimension, including U/S rusted MS cover complete without disturbing the existing pipe lines valves and providing valve chamber including necessary excavation and earth work in any type of soil, returning filling, removal of surplus soil n.exc. 50m distance, 100 mm thickPCC 1:4:8 type D2 (using 40mm graded stone aggregate) with 100 mm projection all around, full brick thick brick work in CM (1:6), 10mm thick internal plastering and 15mm thick external plastering upto 150 mm below ground level in CM (1:4), 50 mm thick PCC 1:2:4 type B-1 coping shall be laid over the masonary wall,6mm thick MS sheet cover with hinges and locking arrangements fixed to angle iron frame made out of 50 x50x6mm MS angle iron with 2 coat of synthatic enameled paint over a coat of red oxied on all exposed steel surface and 2 coats of white washing on plastered surface of valve chamber complete all as specified and as directed . 64 Dismantling damage and broken valve chamber of size 450x450x450mm, internal dimension, including U/S rusted MS cover complete without disturbing the existing pipe lines valves and providing valve chamber including necessary excavation and earth work in any type of soil, returning filling, removal of surplus soil n.exc. 50m distance, 100 mm thickPCC 1:4:8 type D2 (using 40mm graded stone aggregate) with 100 mm projection all around, full brick thick brick work in CM (1:6), 10mm thick internal plastering and 15mm thick external plastering upto 150 mm below ground level in CM (1:4), 50 mm thick PCC 1:2:4 type B-1 coping shall be laid over the masonary wall,6mm thick MS sheet cover with hinges and locking arrangements fixed to angle iron frame made out of 50 x50x6mm MS angle iron with 2 coat of synthatic enameled paint over a coat of red oxied on all exposed steel surface and 2 coats of white washing on plastered surface of valve chamber complete all as specified and as directed . 65 M & L for cleaning of UG Sump capacity upto 20KL at CG Enclave kakinada by pumping out the accumulated water at the bottom and removing the complete silt from the sump and depositing and levelling as directed andcleaning the sump with bleaching powder and wire bursh after scrapping the walls and bottom of the sump completely without disturbing the water supply to the area inlcuding writing the details such as sump capacity, date of cleaning on the sump wall with synthetic enamel paint complete all as specified and directed .Note: Necessary Pump for removing water from sumpand any other material/ equipment required shall be arranged by contractor. Cost of the same shall deemed to be in quoted rate. 66 M & L for cleaning of UG Sump capacity upto 225KL at CG Enclave Visakhapatnam by pumping out the accumulated water at the bottom and removing the complete silt from the sump and depositing and levelling as directed andcleaning the sump with bleaching powder and wire bursh after scrapping the walls and bottom of the sump completely without disturbing the water supply to the area inlcuding writing the details such as sump capacity, date of cleaning on the sump wall with synthetic enamel paint complete all as specified and directed .Note: Necessary Pump for removing water from sumpand any other material/ equipment required shall be arranged by contractor. Cost of the same shall deemed to be in quoted rate. 67 M & L for cleaning of UG Sump capacity upto 100KL at CG Enclave Visakhapatnam by pumping out the accumulated water at the bottom and removing the complete silt from the sump and depositing and levelling as directed andcleaning the sump with bleaching powder and wire bursh after scrapping the walls and bottom of the sump completely without disturbing the water supply to the area inlcuding writing the details such as sump capacity, date of cleaning on the sump wall with synthetic enamel paint complete all as specified and directed .Note: Necessary Pump for removing water from sumpand any other material/ equipment required shall be arranged by contractor. Cost of the same shall deemed to be in quoted rate. 68 M & L for cleaning of UG Sump capacity upto 50KL at CG Enclave Visakhapatnam by pumping out the accumulated water at the bottom and removing the complete silt from the sump and depositing and levelling as directed andcleaning the sump with bleaching powder and wire bursh after scrapping the walls and bottom of the sump completely without disturbing the water supply to the area inlcuding writing the details such as sump capacity, date of cleaning on the sump wall with synthetic enamel paint complete all as specified and directed .Note: Necessary Pump for removing water from sumpand any other material/ equipment required shall be arranged by contractor. Cost of the same shall deemed to be in quoted rate. 69 S&F in repairs MCCB 200 Amp capacity, 4 Pole, 415 Volt grade, rupturing capacity 36kA, including making incoming and outgoing connections using thimbles / lugs of appropriate size, complete all as specified and directed. 70 S&F in repairs MCCB 100 Amp capacity, 4 Pole, 415 Volt grade, rupturing capacity 16kA, including making incoming and outgoing connections using thimbles / lugs of appropriate size, complete all as specified and directed. 71 S&F in repairs MCCB 63 Amp capacity, 4 Pole, 415 Volt grade, rupturing capacity 16kA, including making incoming and outgoing connections using thimbles / lugs of appropriate size, complete all as specified and directed. 72 Material and labour for taking sample of water in sterlised bottles from UG Sump for Analysis of water for the following parameters and obtaining sample test report from Govt Recognized Laboratories:(i) Physio Chemical Analysis of Water (Colour , odour , pH Total solids, Dissolved Solids, Permanent hardness, temporary Hardness, Ammonia feree and salinbe, Ammonia Albuminoidal, Nitrites, Nitreates, Oxygen absorption at 15 Min, Iron , Fluoride)(ii) Microbiological Analysis ( Totral Choliforms , Eschirrchea Coli) Note : 1. A certificate of approval / certification of Lab by Govt Of India / State Govt shall be submitted by the contractor to the deptt. 2. Sample shall be submitted to the Labortory within 24 Hrs of collection of sample 73 M&L for earthing complete with galvanized steel earth plate electrode 600 mm X 600 mm X 6 mm thick buried directly in ground (earth pit not less than 2.25 Mtr deep below normal ground level with top edge of plate not less than 1.5 Mtr below normal ground level connected to galvanised earth strip of 25 x 4 mm size upto 7.50 m bymeans of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No-3 SSR Part -1 2009 connected to earthing test point including earth wire protection pipe of dia 40 mm (light grage), excavation and earth work, disposal of surplus spoil, provn of RCC cover 50 mm thick, reinforced with 8mm dia TMT bars @100 mm /C/C both ways with one handle for lifting made out of 10 mm dia TMT bar embedded in precast cover slab and PCC (1:3:6) type C-1 concrete pit, funnel with watering pipe 20 mm bore (medium grade) testing on completion complete all as specified and directed. [Note : (a)Proper earthing pit should be provided with pit cover. (b) Excavation/earthwork is deemed to be included in the quoted rate.] 74 M&L in repair of solar type kitchen chimany after dismentaling from existing location of building , checking of motor, servicing/overhauling of motor, replacement of warn out parts like filters, motors, light bulbs, switches, ducts and cowls, reinstallation of solar chimany and refixing in same position after completion of work and testing completeall as specified and directed. 75 M & L for repairing of broken earthing pits chamber with PCC (1:3:6) type C-1with RCC cover (1:2:4) type B0, 40 mm thick reinforced with 6 mm dia bar, 3 Nos. both way, funnel with wire mesh for watering pipeincluding Painting with White cement colour (Red/Green/Yellow) ofearthingpitsof diffirent colour as per Earthing type (Chemical/LighteningProtection and Conventional ) complete all as specified and directed. 76 M & L for repairing of Broken Foundations of Monolock Pumps and LT Panel Board including raising of heights of panels as possible at site with PCC (1:3:6) type C-1 and painting the foundations with cement base paint or as per existing pattern complete all as specified and directed. 77 Material and labour for repairing of water supply starter panel board internally, detecting fault in control wiring, contractor, relay, time delay and connecting block including replacement of worn out spare parts with new items as per existing make and specification, Testing and commissioning with entire satisfaction of Engr-in-charge including its rewiring and replacement of defective appliances with new parts and testing complete all as specified and directed. (Notes : Spare partsshall be Measured & Paid separately under relevant supply only items) 78 Supply only Contactor ML-3 / ML-4, 450 Volts complete all as specified and directed. 79 Supply only Indicating lamp (set of 3) complete all as specified and directed. 80 Supply onlySingle phase preventor complete all as specified and directed. 81 Supply only Ameter 0-100Amps with suitable CTs complete all as specified and directed. 82 Supply onlyVoltmeter 0-500 volts with suitable PTs complete all as specified and directed. 83 Supply only Relay 30-40 Amp complete all as specified and directed. 84 Supply only Timer for starter complete all as specified and directed. 85 Supply only Selector switch RYB complete all as specified and directed. 86 Supply only Copper conductor flexible wire 40/0.0076 complete all as specified and directed. 87 Supply only Frequency meter 50Hz complete all as specified and directed. 88 Supply only Phase reverse preventor complete all as specified and directed. 89 Supply only MCCB 250 Amps 4 Pole 36 KA adjustable type for earth fault and overload current complete all as specified and directed. 90 M & L for repair and calibration of the mechanical water level indicator installed on the underground (UG) sump including inspection, servicing, replacement of damaged components such as dial mechanism, float, pulley system, wire rope, and realignment as necessary to ensure accurate and smooth functioning and applying two coats of synthetic enamel paint complete all as specified and directed. 91 Supply and laying of ductile iron pipe of size 100mm dia with spigot and socket end, centrifugaly cast, pressure class K-9 laid in trenches on surface / over masonary pillar and connection to old or new positionincluding taking up / down existing unserviceable pipe complete all as specified and directed. 92 Supply and fixing DI specials fittings of any type, radius and angle complete all as specified and directed 93 Supply and fixing in repair UPVCball valve of size 50 mm dia complete all as specified 94 Supply, install, testing (as per IEC 61439-I) and commisioning of LT feeder piller box of suitable size as per relevant IS, CPRI approved, cubical floor mounted Indoor type, factory made, totally enclosed, dust and vermin proof made out of 2.0mm thick MS sheet duly powder coated both side in and out, having suitable locking arrangments both at front and rear sides, duly drilled holes for connections and mounted on epoxy based post insulators for 3 phase, 4 wire, 500V, 50Hz AC supply, including hibling, cable entry boxes, cable gland, suitable angle iron framed support (bottom portion of the panel), grouted in foundation in PCC 1:2:4 type B1 using 20mm graded stone aggregates including taking down old unserviceable panel complete all as specified and as directed housing and with the following switchgears(for Pump House)Incomming:-(a) MCCB4Pole, 415V, 63 Amps, 25KA - 01NosOutgoing: (a) MCB, TP, 415V, 32 Amps, 10KA - 01 Nos(b) MCB, TP, 415V, 20 Amps, 10KA - 01 Nos(c) MCB, SPN, 415V, 20 Amps, 10 KA - 02 Nos(d) 7.5HP, 3Ph star-delta Motor starter with Main, Star & Delta Contactor, Thermal Over load relay, Star-delta timer(electronic adjectable), Control Transformer, Dry run protection, Phase failure relay , star/stop push botton - 01 Set(e) 10HP, 3Ph star-delta Motor starter with Main, Star & Delta Contactor, Thermal Over load relay, Star-delta timer(electronic adjectable), Control Transformer, Dry run protection, Phase failure relay , star/stop push botton - 01 (f) Digital volt meter & ammeter -02 Set(g) Phase indicator lamps (RYB) set of 3- 02set 95 Comprehensive maintenance and repair of addressable/conventional networked fire alarm systems installed at CGC OTM, Sports Complex, Pandya, Kalinga, Multi-level parking, C1, C2, B9/C3, B10 & B11 buildings within ICGS Complex, Malkapuram. The scope includes routine, preventive, and breakdown maintenance, testing, inspection, cleaning, and calibration of all system components to ensure safe and efficient operation. Thorough checking of fire alarm panel with control units, loop controllers, and power supply modules and connected items as per OEM guidelines shall be done. Replacement of spare parts is included in quoted rates. Minor spares must be provided by the contractor at no extra cost, and major parts shall be measured and paid for separately under respective item of BOQ. A checklist for the fire alarm system shall be prepared for each building and submitted for records complete all as specified and directed. Note :(i)Contractor shall visit the site before quoting the rate. (ii)A supervised fire drill shall be carried out as per user requirement. (iii)A Service Engineer will report to site, within 4 – 8 working hours, from the Time of Complaint Logging.(iv)Training to the User Team will be given Half –Yearly based on Client requirement. 96 Comprehensive maintenance and repair of fire fighting systems consisting of main pump (diesel/electric), jockey pump, control panels, fire hydrants, landing valves, gate valves, NRVs, instrumentation, and associated piping and cabling networks, fire panel installed at CGC OTM Sub-Station, Pandya Bldg, 96Qtrs Pump House & Main Pump House within ICGS Complex, Malkapuram. The scope includes routine, preventive, and breakdown maintenance, testing, inspection, cleaning, and calibration of all system components & panels to ensure safe and efficient operation. Thorough checking of pump performance, controller settings, suction/discharge lines, and valve operations as per OEM guidelines shall be carried out. Replacement of spare parts is included in quoted rates. Minor spares must be provided by the contractor at no extra cost, and major parts shall be measured and paid for separately under respective items of BOQ. A checklist/logbook for the fire fighting system shall be prepared for each building and submitted monthly for records, complete all as specified and directed.Note :(i) The contractor shall visit the site and inspect the fire fighting system before quoting the rate.(ii) A supervised fire drill and hydrant test shall be conducted as per user requirement and recorded.(iii) A Service Engineer shall report to the site within 4–8 working hours from the time of complaint logging.(iv) User training on fire pump operation, valve systems, and emergency procedures shall be provided half-yearly, based on client requirement.(v) The entire system shall be checked and kept in Auto mode with required pressure levels as per OEM standards, wherever applicable. 97 M & L for preparation of exposed steel surface of existing priming tank / LT Panel /pipeincluding removal of dust, rust, grease, and old paint using appropriate tools and solvents and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed. 98 Supply only MS ERW pipe of 150 mm dia, 5.4 mm thickness complete all as specified and directed. 99 Supply only MS ERW pipe of 100 mm dia, 5.4 mm thickness complete all as specified and directed. 100 Supply only MS ERW pipe of 80 mm dia, 4.84 mm thickness complete all as specified and directed. 101 Supply and fixing in repair of damaged/defective/unserviceable fire brigade inlet connection 4 way complete all as specified and directed. 102 Supply and fixing in repair of damaged/defective/unserviceable fire brigade inlet connection 2 waycomplete all as specified and directed. 103 Supply and fixing in repair fire hydrant landing valve GM type A single outletof 63 mm dia withnew hydrant confirming to IS 5290 with PVC blank cap and MS or GI chaincomplete all as specified and directed. 104 Supply and fixing in repair fire hydrant landing valve GM type B ( Double head outlet) of 63 mm dia withnew hydrant confirming to IS 5290 with PVC blank cap and MS or GI chaincomplete all as specified and directed. 105 S&F in repair damaged /defective/unserviceable ABS plastic 3/4 shut off nozzle suitable for 19/20 mm hosecomplete all as specified and directed. 106 S&F in repair presure gauge glycerine filled with 15 mm inlet connection dial size 100 mm of pressure range 0 to 14Kg/cm2 with 15mm isolation valve with G.I. nipplecomplete all as specified and directed. 107 S&F in repair presure gauge glycerine filled with 15mm inlet connection dial size 200 mm of pressure range 0to 21Kg/cm2 with 15mm isolation valve with G.I. nipple complete all as specified and directed. 108 Repair/Servicing of fire hydrant landing valve type A/B of 63 mm dia, including spindle thread machine, washers replacementmnt, checkout, packing serving complete to arrest leakage and proper function of valvecomplete all as specified and directed. 109 S&F in repair CP hose reel 15 m complete all as specified and directed. 110 S&F in repair fire fighting RRL hose pipe of 63mm, ISI marked, IS 63 (type A),15m long fitted with male and female gun metal coupling ISI marked, IS 903 complete all as specified and directed. 111 S&F in repair gunmetal branch pipe with long nozzle suitable for 63 mm dia RRL hose pipe, ISI marked, complete all as specied and directed. 112 Supply and Fix in repair outside hose box cabinet made out of 18 gauge MH sheet of size as per site reqirement but not less than 800mm X 600mm X 250mm with double leafed glazed shutters (glazed with 4mm thick transperent fiber sheet) and door frame made out of 16 guage MS sheet painted fire red outside and brilliant white inside complete all as specied and directed for housing two number RRL hose each 15m long, one number branch pipe with nozzle , first aid hose and single outlet hydrantvalve etc and must have the legend FIRE HOSE painted prominently in graphic style complete all as specified and directed. 113 S&F in repair 4 mm thick sheet glass for fire hose boxes of size 0.20 x 0.20 m complete all as specified and directed. 114 S&F in repairhose reel drum of 20 mm dia and 30 mtr length hose pipe conformingto IS-5132 including gun metal nozzle suitable valve complete all as specified and directed. 115 Supply, install, testing and commissioning of pressure switch with set point up to 7.5 Bar, suitable for use in fire fighting and water supply systems. The pressure switch shall be compact, robust, and enclosed in a weatherproof IP65-rated housing, equipped with SPDT contacts rated for standard control circuits. The unit shall be suitable for vertical or horizontal mounting and compatible with water and air media. It shall include necessary accessories for secure installation and shall be calibrated and tested for reliable cut-in and cut-out pressure control including taking down old unserviceable switch complete all as specified and directed. Make: Danfoss or equivalent approved by GE. 116 Repair and maintenance of fire service main pump, multi-stage, horizontal split casing type, with a capacity of up to 100 HP and a head of 90 metres, operating at 1450 RPM, and coupled with a diesel engine of up to 100 HP. The work includes complete servicing of the pump by replacing unserviceable components such as gland packing, bearings, and charging lubricants to ensure smooth operation. It also includes servicing of the diesel engine by replacing filters, lubricant oil, and other defective parts including coupling, oil and air filters, servicing of radiator, replacement of exhaust gasket, and replacement of diesel supply and return pipes from the tank to the engine. Battery leads shall be replaced as required and the charging circuit shall be checked and made fully functional. The complete pump set, including base frame and associated pipelines inside the pump room, shall be cleaned, surface-prepared, and two coats painted with an approved shade of synthetic enamel paint complete all as specified and directed.Note: Pipelines and pump shall be painted in standard red colour as per Fire Fighting Manual and relevant IS codes, using synthetic enamel paint after proper surface preparation. 117 Repair and maintenance of multi-stage fire service main pump of horizontal split casing type, rated up to 100 HP and delivering a head of 90 metres, operating at 1450 RPM and coupled with an AC induction motor up to 100 HP capacity. The work includes complete servicing of the pump set by replacing worn-out/unserviceable components such as gland packing, bearings, gaskets, nuts, and bolts. Lubricants shall be charged as required to ensure smooth operation. The entire pump set, including base frame and associated pipeline network inside the pump room, shall be thoroughly cleaned, surface-prepared, and painted with two coats of approved shade synthetic enamel paint. Final testing and trial run shall be carried out to confirm smooth and leak-free performance complete all as specified and directed by Engineer-in-Charge.Note: Pipelines and pump shall be painted in standard red colour as per Fire Fighting Manual and relevant IS codes, using synthetic enamel paint after proper surface preparation. 118 Repair and maintenance of fire service jockey pump, multi-stage, horizontal split casing type, with a discharge capacity of up to 180 LPM at 90 metres head, operating at 2900 RPM and coupled with an AC induction motor of up to 5.5 HP. The work includes complete servicing of the pump by replacing unserviceable components such as gland packing, bearings, gaskets, nuts, and bolts, and charging of lubricants to ensure smooth and efficient operation. The entire pump set, including base frame and associated pipeline network inside the pump room, shall be cleaned, surface-prepared, and painted with two coates of synthetic enamel paint of standard fire-fighting red colour over one coat of primer, as per fire safety norms and relevant IS codes complete all as specified and directed. 119 Repair and maintenance of fire service terrace/booster/priming pump, multi-stage, horizontal split casing type, with a discharge capacity of 900 LPM at 36 metres head, operating at 2900 RPM and coupled with an AC induction motor. The work includes complete servicing of the pump by replacing unserviceable components such as gland packing, bearings, gaskets, nuts, and bolts, and charging lubricants to ensure smooth and efficient operation. The entire pump set, including base frame and associated pipelines within the pump room, shall be cleaned, surface-prepared, and painted with synthetic enamel paint of standard fire-fighting red colour, as per relevant fire safety norms and IS standards complete all as specified and directed. 120 S&F in repair ball valve with brass spindle of 25mm dia complete all as specified and directed. 121 S&F in repair ball valve with brass spindle of 50 mm dia complete all as specified and directed. 122 Supplying, installing, testing and commissioning of 150mm CI butterfly valve conforming to IS:13095, suitable for waterworks application and hydrostatically tested to a minimum pressure of 20 kg/cm². The body shall be of high-strength cast iron (as per IS:210), circular in shape, designed to withstand a minimum working pressure of 10 kg/cm². The disc shall be heavy-duty cast iron with anti-corrosive epoxy or nickel coating. Valve seat shall be made of high-grade elastomer/nitrile rubber ensuring full 360° sealing in closed position. Shaft shall be of EN-8 grade carbon steel. The valve shall be designed for installation between two pipe flanges with extended rubber edges to ensure leak-proof sealing including taking down old unserviceable valve complete all as specified and directed. (Makes: Audco/Kirloskar/Honeywell) 123 Supplying, installing, testing and commissioning of 100mm CI butterfly valve conforming to IS:13095, suitable for waterworks application and hydrostatically tested to a minimum pressure of 20 kg/cm². The body shall be of high-strength cast iron (as per IS:210), circular in shape, designed to withstand a minimum working pressure of 10 kg/cm². The disc shall be heavy-duty cast iron with anti-corrosive epoxy or nickel coating. Valve seat shall be made of high-grade elastomer/nitrile rubber ensuring full 360° sealing in closed position. Shaft shall be of EN-8 grade carbon steel. The valve shall be designed for installation between two pipe flanges with extended rubber edges to ensure leak-proof sealing including taking down old unserviceable valve complete all as specified and directed. Approved makes: Audco/Kirloskar/Honeywell. 124 Supplying, installing, testing and commissioning of 80mm CI butterfly valve conforming to IS:13095, suitable for waterworks application and hydrostatically tested to a minimum pressure of 20 kg/cm². The body shall be of high-strength cast iron (as per IS:210), circular in shape, designed to withstand a minimum working pressure of 10 kg/cm². The disc shall be heavy-duty cast iron with anti-corrosive epoxy or nickel coating. Valve seat shall be made of high-grade elastomer/nitrile rubber ensuring full 360° sealing in closed position. Shaft shall be of EN-8 grade carbon steel. The valve shall be designed for installation between two pipe flanges with extended rubber edges to ensure leak-proof sealing including taking down old unserviceable valve complete all as specified and directed. Approved makes: Audco/Kirloskar/Honeywell. 125 Supply and fixing in repair approved quartezoid bulb 15 mm dia sprinkler pendent type , IS 15106 chrome plated crossette plate, with temperature rating 68 degree with universal deflector as approved by T.A.C complete with all necessary connections complete all as specified and directed. 126 Supply Only analogue addressable multisensor detector (Photo + Thermal) with base with galvanised steel, back box and all mounting accessories complete all as specified and directed. 127 Supply Only analogue smoke detector with all mounting accessories complete all as specified and directed. 128 Supply only addressable Dual Action Manual Pull staions inside for providing MS box of suitable size for concealing the manual call point in the wall and with mounting accessoriescomplete all as specified and directed. 129 Supply onlyaddressable Riser Modules with mounting accessoriescomplete all as specified and directed. 130 Supply onlyaddressable control relayModulewith 230 V 2 A where required in a junction box with mounting accessoriescomplete all as specified and directed. 131 Supply onlyaddressable riserModulefor Hooter in ajunction box with mounting accessoriescomplete all as specified and directed. 132 Supply onlyElectronic Hooterinclude provide MS box suitable size for concealing the hooter in the wall mounting accessories complete all as specified and directed. 133 Supply only Conventional Dual Action Manual Pull staions inside for providing MS box of suitable size for concealing the manual call point in the wall and with mounting accessoriescomplete all as specified and directed. 134 Supply onlyElectronic Hooterinclude provide PVC box suitable size for concealing the hooter in the wall mounting accessories complete all as specified and directed. 135 Supply only EST network card for addressable fire alarm control panel complete all as specified and directed. 136 Supply only EST make, power supply unit for EST 3 addressable fire alarm control panel complete all as specified and directed. 137 Supply and fixing of micro processed based upto 16 zone conventional fire alarm control panel with standards NFPA 72 can operate up to 30 detectors per zone, Board should consist of RS 485 ,2 programmable relay, support port for class B style input devices with networkable ability the above price includes two batteries, installations, commissioning, and networking with main integration network including taking down old unserviceable panel complete all as specified and directed. 138 S&F in repair of manual call point glass/fibre flip cover transparent typefixed to surface mounted MCP complete all as specified and directed.

Key Value

Document Fees
INR 500 /-
EMD
INR 94300.0 /-
Tender Value
INR 47.51 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail