Tender For Renovation Of Both The Damaged Ducts To Prevent Sewage Leakage In Upper Dalibagh Colony Block No. 8 Type-4, Breaking The Floor Of The Bathrooms Connected To The Duct And Replacing The Damaged Pipes, And Replacing Pvc/Cpvc Pipes In The Duct - Di, lucknow-Uttar Pradesh

Public Works Department has published Tender For Renovation Of Both The Damaged Ducts To Prevent Sewage Leakage In Upper Dalibagh Colony Block No. 8 Type-4, Breaking The Floor Of The Bathrooms Connected To The Duct And Replacing The Damaged Pipes, And Replacing Pvc/Cpvc Pipes In The Duct - Di. Submission Date for this Tender is 06-09-2025. Duct Supply Tenders in lucknow Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

50974492
Tender For Renovation Of Both The Damaged Ducts To Prevent Sewage Leakage In Upper Dalibagh Colony Block No. 8 Type-4, Breaking The Floor Of The Bathrooms Connected To The Duct And Replacing The Damaged Pipes, And Replacing Pvc/Cpvc Pipes In The Duct - Di
Tender
Indian
Uttar Pradesh
Lucknow
06-09-2025

Tender Details

Renovation of both the damaged ducts to prevent sewage leakage in Upper Dalibagh Colony Block No. 8 Type-4, breaking the floor of the bathrooms connected to the duct and replacing the damaged pipes, and replacing PVC/CPVC pipes in the duct. - Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead DAR 15.56 2 Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. In cement mortar DAR 15.7.4 3 Dismantling tiles work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. For thickness of tiles 10 mm to 25mm. DAR 15.23.1 4 Dismantling 15 to 40 mm dia G.I. pipe including stacking of dismantled pipes (within 50 metres lead) as per direction of Engineer-in-Charge. (a) Internal Work- Exposed on wall DAR 14.84 5 Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. DAR 18.77 6 Providing and fixing on Wall Face Unplasticised Rigid PVC rain water Pipes conforming to IS:13592 Type A, including Jointing with Seal ring conforming to IS:5382, Leaving 10mm Gap for thermal expansion, all fittings like two nos bend, one mo Coupler or any other accessories and P/F PVC pipe clips fixed by means of 50X50X50mm hard wood plug, Secrewed with MS Screws of required lenght in wall face including cutting brick work and fixing in cement mortar 1:4 (i) Single Socketed pipes 110mm dia meter. 7 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 20 mm nominal dia Pipes 18.9.2 8 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 25 mm nominal dia Pipes 18.9.3 9 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 32 mm nominal dia Pipes 18.9.4 10 Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying: (a) after surface preparation, first layer of slurry of cement @ 0.488 kg/ sqm mixed with water proofing cement compound @ 0.253 kg/sqm. (b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. (c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. (d) fourth and final layer of brick tiling with cement mortar (which will be paid for separately. For the purpose of measurement the entire treated surface will be measured. DSR 22.6 11 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:4 (1 cement : 4 coarse sand) DAR 6.4.1 12 15 mm cement plaster on rough side of single or half brick wall of mix: 1:4 (1 cement: 4 coarse sand) DAR 13.5.1 13 15 mm cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall. DAR 13.10 14 Finishing wall with Premium Acrylic Smooth exterior Paint with Silicone Additives of required Shade New work. (Two or More Coats applied @1.43 ltr/10 sqm) Over and Including Priming Coat of Exterior Primer applied @ 2.20kg /10 sqm) (Apex Ultima, Weather Coat All guard asian, Berger. (Ch-15/DSR N0-13.47.1, ) 15 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-iii) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) DAR 4.1.3 16 Providing and laying rectified Glazed ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer) of 1st quality conforming to IS: 15622 of approved make in colours White, lovry GreyFume Red Brown laid on 20 mm thick cement mortar 1:4 (1 cement :4 Coarse sand) jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joints with white cement and matching pigments etc complete. 11.39 17 Providing and fixing white vitreous china water closet squatting pan (Indian type) :Orissa pattern W.C. pan of size 580x440 mm DAR 17.13.2 18 P/F white vitreous china pedestal type (European type /wash down type) water closet pan.17.15. 19 Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete. 10 litre capacity - White DAR 17.18.1 20 Providing and fixing of 100 mm Pvc plain bend of required degree including cost of labour T&P etc complete 21 Providing and fixing PVC P trap of self cleansing design with screwed down complete, including cost of cutting and making good the walls and floors: 100 mm inlet size 22 Providing and fixing pvc Nahani trap 100x75 mm of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors: 100 mm inlet and 75 mm outlet including cost of labour T&P etc complete 23 Structual Steel work riveted bolted or welded in built up section, trusses, Builds up gates,framed work lncluding cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. Sl.N0-10.2, 24 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) nondecorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws DAR 9.21.1 25 Disposal of moorum/building rubbish/ malba/ similar unserviceable, dismantled or waste material by mechanical transport including loading, transporting, unloading to approved municipal dumping ground for lead upto 10 km for all lifts, complete as per directions of Engineer-in-charge. Note - item to be applicable in urban areas having directions for restricted hours for movement/plying of load carrying motor vehicle of 3.5 cum or more. DAR-1.1.18,

Key Value

Document Fees
INR 860 /-
EMD
INR 107200.0 /-
Tender Value
INR 10.72 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail