| 1 | Supplying and Fixing of 3Phase 7.5HP,5.5 KW DOL type submersible pump controllerhaving technical specifications : - Max operating current- 14.27Amp,OLR - 13.2-20Amp,Contactor AC3 (a) - 20Amp 415 volt Including connection etc as required as per direction of engineer incharge.Make-Crompton/KSB/Kirlosakr/CRI/Lubi/Havells(IHSDOAL1*A) or ISI approved make |
| 2 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc.with charcoal/ coke and salt as required. |
| 3 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 4 | Supplying of 3.5CX25Sqmm Aluminium armoured,XLPE Insulated,650/1100V grade IS7098(Part1)1988 etc as reuired as per direction of engineer incharge. Make-Polycab/Havelles/Finolex |
| 5 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size direct in ground including excavation and refilling the trench etc. as required,but excluding sand cushioning and protective covering.Upto 35 sq.mm |
| 6 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)6 way, Double door |
| 7 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole |
| 8 | Supplying and fixing of 40Amp, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 9 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductorsingle core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulatedcopper conductor single core cable etc. as requiredGroup A |
| 10 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVCinsulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 11 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 12 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 13 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings) |
| 14 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required |
| 15 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle) |
| 16 | Supply,Installation, testing and commissioning of energy saving ceiling fan having specification :- Size-1200mm,Air delivery - 220 mm3,colour- Ivoury including wiring the down rods of standardlength (upto 30 cm) with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable etc. as required.Make -Usha/Havells/Crompton |
| 17 | Providing and fixing of prewired 20/22 watt box type LED batten having 6000K/4000K CCT, extruded thermoplastic body with PC diffuser in unique square shape & 240 degree wide distribution directly on ceiling/ wall, including connection with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable and earthing completeas required.Make- Havells/Phillips/Crompton/Panasonic/Bajajetc.as per direction of Engineer-In-charge. |
| 18 | SITC 45/48Watt LED street light I/P voltage 220V AC, with suitable electronic driver and high power LED as light source,with secondary optics made in pressure die cast housing with toughned glass IP66 protection on existng GI pipe bracket i/c connection etc as required.Make- - Havells/Crompton/Bajaj/SYSKA |
| 19 | P/F of 40/43mm Dia 1.5Mtr long GI Pipe (Medium class) bracket on the existing wall with suitable MS clamp 2Nos and Nut & bolt for mounting of LED fitting i/c painting etc as required as per direction of engineer incharge. |
| 20 | SITC of outdoor double door joint box having dust and vermin proof compartmentalized panel made out of CRCA sheet required hardware duly treated for degusting in 7 tank process with dephosphating and with powder coating on both side of panel in desired shade. The panel having PU/Neoprene rubber gasket of not less than 3 mm thickness. Separate detachable gland plate suitable MS base channel/angle iron, hinged door(Both side) with locking arrangement for equipment /switchgear thickness of sheet shall not be less than 1.6 mm up to 600 mm length/width of any compartment and be of 2.0 mm above 600 mm. Load bearing structure shall be of 2.0 mm thick sheet supported stand made byby angle iron (50x50x6mm) size (0.600x0.600)x0.300)Mtr . Both side openable wall compartment having bolted type door with / without detachable extension type structure (Only outer area on all sides shall be measured & panel to be fabricated from CPRI approved fabricator) outdoor joint box having 1.6mm thick CRCA sheet &800amp,415Volt capacity 4 strip Aluminum bus barby means of SMC / DMC type insulator, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves Aluminum bus bar installed on insulatoretc as required as per direction of engineer incharge. Panel Size:- (0.600X0.600)x0.300Mtr |