Tender For Instrumentation Works For Gds Unit And Propylene Recovery Section For Epcm1 At Nrep; 1 Supply of following items Supply charges including charges for transportation, unloading at site, MTC, fasteners, accessories, material inspection at Vendor work shop including TPI charges , , MOCas per Modulating & ON/OFF Control and Isolation Valves-TP-1ZZZA-IC-SPE-0011 & TP-1ZZZA-IC-SPE-0012; For Hooter, Beacon & FireDetectors refer Specification-TP-1ZZZA-IC-SPE-0024_D1. 2 SOLENOID VALVES 3 AIR FILTER REGULATORS 4 BEACON & HOOTER 5 TERMINAL BLOCKS 6 DIN RAIL 7 Hand SWITCH STOP, RESET 8 Light Interface Unit with Patch Chord - 6 port 9 8-Port ethernet switch 10 RS-485 to MODBUS TCPIP converter- Industrial Grade of reputed make 11 Ethernet to FO converter - industrial grade of reputed make 12 Corrosion probe with Hand held indicator and retractable probe and mandatory spare. (Refer MR documentTK-1ZZZA-IC-SPE-0035 for details) 13 JUNCTION BOXES - SUPPLY 14 Supplycharges including handling, TPI charges, transportationto the installation location, required hardware’s/fasteners, plugging of spare entries, Tagging, box-up, suitable greasing forscrews/L key screws, tools & tackles, manpower,scaffoldingetc. (MOC of hardwares shall as pertkUIPL -India specificationand direction of Engineer-in-Charge. 15 WEATHERPROOF JUNCTION BOXES 16 30 Terminals 17 EX-ROOF/FLAME PROOF JUNCTION BOXES 18 20Terminals 19 12 Terminals 20 06 Terminals 21 40 Terminals 22 EX-PROOF/FLAME PROOF/WEATHER PROOF HAND SWITCHES/PUSH BOTTON - SUPPLY 23 PUSH BUTTON STATION / CONTROL / LOCAL PANELS 24 EMERGENCY STOP 25 VIBRATION RESET/ON-OFF VALVES RESET PB STATION 26 BEACON TEST AND RESET PB STATION 27 INSTRUMENT AIR MANIFOLDS- SUPPLY 28 Supply charges including handling, transportationto the installation location, hardware/fasteners, accessories installation, pneumatic testing, cleaning/flushing, require consumables, tools & tackles, manpower, etc. all complete as per specification all complete as per specification TP-1ZZZA-IC-SPE-0033_D1 Specification for Instrument Installation. and direction of Engineer-in-Charge. 29 10 WAY 30 TUBE AND TUBE FITTING- SUPPLY 31 Supply charges including handling, TPI charges, transportation to the workinglocation, fabrication, accessories installation (fittings, valves manifold, etc.), tools & tackles, manpower, scaffolding , Hydro/Pneumatic testing, dressing, clamping, tagging, etc. all completeas per specification TP-1ZZZA-IC-SPE-0033_D1 Specification for Instrument Installation 32 SS316 TUBE SIZE 33 12mm OD x 1.65mm WT, Seamless, SS316 34 10mm OD Copper Tube 35 FITTINGS- SS316 36 MALE CONNECTORS- SS316 (1/2 NPTM x 1/2 OD) 37 FEMALE CONNECTOR- SS316 (1/2 NPTF x 1/2 OD) 38 UNION TEE (1/2 OD x 1/2 OD x 1/2 OD) 39 TUBE UNION (1/2 OD x 1/2 OD) 40 TUBE CAP (1/2 OD) 41 NEEDLE VALVE 42 END BLIND CAP (NPT MALE) 43 ADAPTOR/REDUCER 44 GATE VALVE (1/2 NPTF x 1/2 NPTF) 45 CONDENSATE POT-SS316 (3 Pot with, 1/2NPT) 46 MALE CONNECTORS- SS316 (1/4 NPTM x 12mm OD) 47 FEMALE CONNECTOR- SS316 (1/4 NPTF x 12mm OD) 48 END BLIND CAP ( 12mm OD) FOR TUBE 49 2 VALVE MANIFOLD SS316 (1/2NPTFx1/2NPTF) 50 2 VALVE MANIFOLD SS316 (1/2NPTFx1/2NPTM) 51 CONDENSATE POT-SS316 (3 Pot with, 3/4NPT) 52 Instrument Tube support 53 CABLE GLANDING AND TERMINATION 54 Supply charges includingTPI charges, transportation to working location ,require hardware/fasteners, consumables, installation of hoods & adapters, tagging ,ferruling, lugging, supply of consumables( like lugs, sleeve for shield/drain, sealing compounds etc.) , making suitable holes for cable entries, tools & tackles, manpower, scaffolding etc. all complete as per specification and direction of Engineer-in-Charge. Glanding & termination is included in cable laying cost. Following is applicable if contractor to perform only glanding & termination and cables are layed by others. 55 SIGNAL,CONTROL,POWER CABLES 56 1/2 NPTDOUBLE COMPRESSIONSS304 with shrouds 57 1/4 NPTDOUBLE COMPRESSION SS304 with shrouds 58 1-1/2 NPTDOUBLE COMPRESSION SS304 with shrouds 59 1-1/4 NPTDOUBLE COMPRESSION SS304 with shrouds 60 1 NPT DOUBLE COMPRESSION SS304 with shrouds 61 1/2 NPTBLINF PLUG 62 1-1/2 NPTBLIND PLUG 63 CABLE GLANDS 1-1/2 ET, Weatherproof with Checknut (PANEL) 64 CABLE GLANDS 1 ET, Weatherproof with Checknut (PANEL) 65 CABLE GLANDS 1-1/4 ET, Weatherproof with Checknut (PANEL) 66 1 1/2NPT X 2NPT ADAPTER DOUBLE COMPRESSION CABLE GLAND 67 1 1/2NPT X1*1/4NPT (F) NPT Reducer DOUBLE COMPRESSION CABLE GLAND 68 1 1/2NPT X 1NPT ADAPTER DOUBLE COMPRESSION CABLE GLAND 69 1/2 NPT X 3/4NPT ADAPTER DOUBLE COMPRESSION CABLE GLAND 70 ADAPTORM32 (M) x M40 (F) 71 3/4 NPTDOUBLE COMPRESSION 72 FIBER OPTICAL; ARMOURED /UNARMOURED 73 Scope includes preparation of all fibres and splicing / patching ,Supply of adequate consumables for the execution of the work (such as fibre optic connectors suitable for the application), testing, tools & tackles, manpower, scaffolding etc. all complete as per specification REFER ASTP-1ZZZA-IC-SPE-0033_D1 Specification for Instrument Installation and direction of Engineer-in-Charge. 74 FIBER-OPTIC CABLES- Single Mode , 6 Fibre 75 CABLE TRAYS/DUCTSSUPPLY & INSTALLATION 76 Supply charges including transportation to working location, TPIcharges ,Fabrication, Clamping, accessories installation (including bends, elbows, reducers etc.), Tray identification, painting wherever require, consumables, tools & tackles, manpower, scaffolding etc. all completeas per tkUIPL -INDIA specificationand direction of Engineer-in-Charge. TP-1ZZZA-IC-SPE-0033_D1 Specification for Instrument Installation 77 PERFORATED TRAY WITH COVERS ANODISED ALUMINIUM (Upto 300mm Bends shall be site fabricated) 78 WIDTH 300 MM 79 WIDTH 150 MM 80 WIDTH 100 MM 81 WIDTH 50 MM 82 CONDUITS : 83 RIGID HDPE CONDUITS : HDPE conduit shall be as per IS-4984 or as per equivalent IEC code. The outer sheath colour of HDPE conduits shall be orange with black for the fittings throughout the fibre optic cable run.Installation charges including transportation from tkUIPL /Client material store to working location, fabrication like (making threads, bends, etc.), require hardware’s/fasteners (U clamps etc.), clamping/supporting, accessories installation(fittings), consumables, tools & tackles, manpower, scaffoldingetc. all complete as per tkUIPL -INDIA specification-REFER ASTP-1ZZZA-IC-SPE-0033_D1 Specification for Instrument Installation and direction of Engineer-in-Charge. 84 25 mm nominal dia 85 50 mm nominal dia 86 FLEXIBLE CONDUITS (SS304): Supply and Installation charges includingTPI charges, transportation to working location, fabrication like (making threads, bends, etc.), require hardware’s/fasteners (U clamps etc.), clamping/supporting, accessories installation(fittings), consumables, tools & tackles, manpower, scaffoldingetc. all complete as per tkUIPL -INDIA specification REFER ASTP-1ZZZA-IC-SPE-0033_D1 Specification for Instrument Installation and direction of Engineer-in-Charge. 87 25 mm nominal dia conduit 88 50 mm nominal diaconduit 89 CANOPY /SUNSHADEFRP - SUPPLY 90 Supplycharges including TPI charges ,transportationto working location, supporting wherever requireforinstruments, JBs , etc. (like integratedinline instruments, close couple mounted instruments, etc.), hardwares/fasteners, consumables etc. Fabrication, installation, tools & tackles, manpower, scaffolding etc. all complete as per tkUIPL -INDIA specification and direction of Engineer-in-Charge.TP-1ZZZA-IC-BOD-0001_D3 Engineering Design Basis for Instrumentation 91 PREFABRICATED. CANOPIES 92 SINGLE TRANSMITTER INCLUDING TEMP ELEMENT & GAS/ FIRE DETECTOR 93 TWOTRANSMITTERS/INSTRUMENTS 94 SINGLE JUNCTION BOXES 95 THREE JUNCTION BOXES 96 FOUR JUNCTION BOXES 97 HAND SWITCH/PUSH BUTTON 98 Multiple transmitters/instruments 99 Two Junction boxes 100 Six Junction boxes 101 Eight Junction boxes 102 Five Junction boxes 103 SEVEN JUNCTION BOX 104 STANCHIONS FOR INSTRUMENTS - SUPPLY 105 Supply charges including TPI charges, transportation to workinglocation,brication, surface cleaning, painting, suitable clamps with pipe line (for close couple hook-ups etc.), hardwares/fasteners, grouting, clamps, consumables, tools & tackles, manpower, scaffolding etc. all complete as per tkUIPL -INDIA specification-REFER AS PER DOCUMENT INSTRUMENT INSTALLATION SKETCHES and direction of Engineer-in-Charge.REFER AS PER DOCUMENT TP-1ZZZA-IC-STD-0001 INSTRUMENT INSTALLATION SKETCHES 106 FLOOR MOUNTING 107 PLATFORM MOUNTING 108 OUTSIDE HAINDRAIL 109 MULTIPLE TX ON PLATFORM MOUNTING 110 STRUCTURAL STEEL 111 Supply charges including TPI charges,transportation , fabrication, installation, surface cleaning, painting , consumables, tools & tackles, manpower, etc. all complete as per tkUIPL -INDIA specification.and direction of Engineer-in-Charge. 112 STRUCTURAL STEEL 113 NUT & BOLTS WITH WASHERS, M10x35mm, SS 114 ANCHOR FASTNER, M10x80mm, MS (CADMIUM) 115 BEAM CLAMP WITH SS BOLT & NUT , HEIGHT 40mm, MS/SS 116 PIPE CLASSB,IS=1239 PART-1 , 2, MS(PAINTED) 117 TYPE J HOOK BOLT & NUT , M10x100mm, MS 118 ANCHOR FASTNER, M10x100mm, MS HD.GALVANISED 119 ANCHOR FASTNER, M12x100mm, MS (CADMIUM) 120 STRUT CHANNEL (1-5/8) 121 MS GI ROD THREADED (1/2) 122 SQUARE WASHER (1/2)