}

Tender For Repair /Replacement Of All Type Of Dg Set And Amf Panel And Misc Repairs And Other Connected Works At New Drde Area And Repair /Replacement Of 250 Kva And 160 Kva Dg Set And Amf Panel And Misc Repairs And Other Connected Works At Old Drde Gwali, gwalior-Madhya Pradesh

Military Engineer Services has published Tender For Repair /Replacement Of All Type Of Dg Set And Amf Panel And Misc Repairs And Other Connected Works At New Drde Area And Repair /Replacement Of 250 Kva And 160 Kva Dg Set And Amf Panel And Misc Repairs And Other Connected Works At Old Drde Gwali. Submission Date for this Tender is 20-09-2025. Mechanical engineering Service Tenders in gwalior Madhya Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

50951960
Tender For Repair /Replacement Of All Type Of Dg Set And Amf Panel And Misc Repairs And Other Connected Works At New Drde Area And Repair /Replacement Of 250 Kva And 160 Kva Dg Set And Amf Panel And Misc Repairs And Other Connected Works At Old Drde Gwali
Tender
Indian
Madhya Pradesh
Gwalior
20-09-2025

Tender Details

REPAIR /REPLACEMENT OF ALL TYPE OF DG SET AND AMF PANEL AND MISC REPAIRS AND OTHER CONNECTED WORKS AT NEW DRDE AREA AND REPAIR /REPLACEMENT OF 250 KVA AND 160 KVA DG SET AND AMF PANEL AND MISC REPAIRS AND OTHER CONNECTED WORKS AT OLD DRDE GWALIOR UNDER GE (I) R&D DELHI; 1 M&L for top overhaul of 160 KVA DG Set complete with dismantling of cylinder heads from the engine, dismantling of inlet/outlet valves complete with taking the cylinder heads to shop floor for replacement of valve sheets, fitment of new valve sheets and lapping with new inlet/outlet valves,replacement of valve springs etc including decarbonisation of cylinder heads and piston heads, taking the cylinder heads back and refixing in position conplete with tappet setting and proving and testing complete all as specified and directed.Note: - Spare parts for top overhaul will be measured and paid separately as part of BOQ. 2 Supply only inlet valves 3 Supply only inlet valve sheet 4 Supply only outlet valves 5 Supply only outlet valve sheet 6 Supply only inlet valve spring set 7 Supply only outlet valve spring set 8 Cylinder head gasket set complete 9 Injector nozzles 10 HP fuel pipes 11 M&L for servicing /preventive maintenance of DG set of capacity 160KVA and 320 KVA at site comprising of the following checks & readjust valve tapped clearence in cold conditions, drain out used engine oil by opening the oil chamber, cleaning the chamber throughly, refixing the chamber cover with new gasket ,pouring the new engine oil, replacement of diesel filters ,oil filter, air filter,cleaning the diesel tank, clean radiator fins & air to air after cooler & AVM pads , check rubber sealand hose pipes replace if found defective, check coupling disc on injection pump, check speed governer for proper functioning and lubricate all leakage, check and clean air cleaner element, check functioning of engine protection units, replace the sensors if required and carry out resetting of cut outs, repair of instruments panel etc.and replacement of small minor items such as nut, bolts, washers, etc are included in quoted rates of sch Acomplete all as specified and directed.Note: Engine oil and filters shall be measured & paid separately under respective items. 12 Supply only Fuel Filters for 160 KVA DG set 13 Supply only Fuel Filter for 320 KVA DG Set 14 Supply only bypass filter 320 KVA 15 Supply only Air filter element primary for 320 KVA 16 Supply only Air filter element secondaryfor 320 KVA 17 Supply only Oil Filter Assy 160 KVA DG Set 18 Supply only Oil Filter Assy 320 KVA 19 Supply only Set of rubber ‘O’ ring 160 KVA to 320 KVA 20 Supply only Pipe air cleaner to turbocharger 160 KVA DG Set 21 Supply only Hose pipes & Flexible pipesfor DG set 160 KVA 22 Supply only Hose pipes & Flexible pipesfor DG set 320 KVA 23 Supply only Fan belt for water pump/radiator fan for DG set 160 KVA(make-Fenner/Poly-F/ Roulunos). 24 Supply only Fan belt for water pump/radiator fan for DG set 320 KVA(make-Fenner/Poly-F/ Roulunos). 25 Supply only Fan belt for alternator dynamofor 320 KVA (make-Fenner/ Poly-F/Roulunos). 26 Supply and filling in replacement ofengine oil 20 W 40 and as type required at site .Make- servo & equivelent 27 Supply and filling of coolent for radiator DAFC 30 %.Make- servo 28 Supply only the following items/spares: - 29 Fuel Filter 25 KVA DG Set 30 Oil Filter 25KVA DG Set 31 Air filter( primary/secondary) set 25 KVA DG Set 32 Fuel Filter 75 KVA DG Set 33 Oil Filter 75 KVA DG Set 34 Air filter (primary/secondary) set 75 KVA DG Set 35 Fuel Filter 125 KVA DG Set 36 Oil Filter 125 KVA DG Set 37 Air filter set(primary/secondary)125 KVA DG Set 38 Fuel Filter 160 KVA DG Set 39 Oil Filter 160 KVA DG Set 40 Air filter set (primary/secondary)160 KVA DG Set 41 Fuel Filter 250 KVA DG Set 42 Oil Filter 250 KVA DG Set 43 Air filter set(primary/secondary) 250 KVA DG Set 44 DEF (Diesel Exhaust Fluid), Technical grade DEF solution suitable for Diesel Generator Set complete all as specified and directed. 45 Dismantling and computerised calliberation of fuel injection pump ofDG Set of 160 KVA cap including replacement of barrel, plunger, anti dribble device, seal kits includingrefixing and testing complete all as specified and directed. 46 Supply and fixing in replacement of water pump assyof 160 KVA DG Set complete all as specified and directed. 47 Supply and fixing in replacement of water pump assyof 320 KVA DG Set complete all as specified and directed. 48 Dismantling and taking down the dynamo alternator assembly from the engine and carry out servicing and maint of alternator of cap 160/320 KVA including opening of alternator and rewinding of armature and field windings if required, replace commutator and carbon brushesif required, replace worn out bearings/bushes and repair shaft if necessary, lubricate all moving parts, reassembling and refixing the alternator in position complete with testing and proving, complete all as specified and directed. 49 Supply only carbon brushes for capacity 160 KVA to 320 KVA. 50 Supply only petrolium jelly 51 Cleaning and scraping of old painted surface of 320 KVA DG set including removing of oily substances for painting of complete DG Set (such as Engine, alternator, base frame, inlet/out let pipes, fuel tank cylinderical/ square type with stand, LT control panel board, by using first quality automotive paint as per MES colour codes including canopy and letterwritting of SM/MES No and out going feeder names on LT panel complete all as specfied and directed. 52 Cleaning and scraping of old painted surface of 160 KVA DG set including removing of oily substances for painting of complete DG Set (such as Engine, alternator, base frame, inlet/out let pipes, fuel tank cylinderical/ square type with stand, LT control panel board, by using first quality automotive paint as per MES colour codes and letterwritting of SM/MES No and out going feeder names on LT panel complete all as specfied and directed. 53 Supply and fixing sensing / controlcard for digital control panel for capacity 160 to 320 KVADG set complete all as specified and directed. 54 Supply and fix in repair servo controller governor suitable for 320 KVA Cummins DG set complete all as specified and directed. 55 Dismantling and taking down the self starter assembly from the engine and carry out servicing and maint of of the starter of cap 160 KVA including opening and rewinding of armature and field windings if required, replace solenoid coil, replace worn out bearings/bushes and repair shaft if necessary, replace vendix drive, lubricate all moving parts, reassembling and refixing the self starter in position complete with testing and proving, complete all as specified and directed. 56 Dismantling and taking down the self starter assembly from the engine and carry out servicing and maint of of the starter of cap 320 KVA including opening and rewinding of armature and field windings if required, replace solenoid coil, replace worn out bearings/bushes and repair shaft if necessary, replace vendix drive, lubricate all moving parts, reassembling and refixing the self starter in position complete with testing and proving, 57 Dismantling of 320 KVA DG Set alternator from engine complete with dismantling of armature, cleaning of armature and field windings, replace the windings if required including varnishing, replacment of worn out bearings, replacement of unserviceable ACVR, cooling fan etc including lubrication of all moving parts complete with reassembling and fixing back in position, testing and proving complete all as specified and directed.Note: - Winding of alternator is deemed to be included in the quoted rate, 58 Supply only AVR suitable for 320 KVAcapacity DG set complete. Make- National equivalent as approved by GE. 59 Supply only bearings of suitable size 60 Supply only carbon brushes 61 Cooling fan 62 Grease 63 M&L for dismantling of 160 KVA DG Set alternator from engine complete with dismantling of armature, cleaning of armature and field windings, replace the windings if required including varnishing, replacment of worn out bearings, replacement of unserviceable ACVR, cooling fan etc including lubrication of all moving parts complete with reassembling and fixing back in position, testing and proving complete all as specified and directed.Note: - Winding of alternator is deemed to be included in the quoted rate, 64 Supply only AVR suitable for 160 KVAcapacity DG set complete. Make- National equivalent 65 Supply only bearings of suitable size 66 Supply only carbon brushes 67 Cooling fan 68 Grease 69 S&F in replacement of maintenance free battery 12 volts,180 AH nake :- Exide Express,or equilent in Amaron as approved by GE. 70 S&F in replacement of battery charger auto type 24 volts x 10 amps complete with all accessories. Make :- Hira/Luxmi as approved by GE. 71 S&F in replacement ofbattery charger auto type 12 volts x 8 amps complete with all accessories. Make :- Hira/Luxmi as approved by GE. 72 Dismantling and opening of turbo charger assembly of 160 KVA DG Setand decarbonising, repair/overhauling and replacement of turbo charger kit including refixing, testing complete as directed by Engineer in Charge. 73 Dismantling and opening of turbo charger assembly of320 KVA DG Setand decrabonising,repair/overhauling and replacement of turbo charger kit including refixing, testing complete as directed by Engineer in Charge. 74 Supply only distiiled water packed in containers all as specified and directed. 75 Supply only acid Mixture electrolite (gravity 1200-1220) packed in 1 ltr bottle packing all as specified and directed. 76 M&L for battery lead heavy duty multi strands copper of size 25 sq mm 4 feet long in red and black colour all as required complete all as specfied and directed. 77 M&L for replacement of heavy duty brass terminals suitable for 24 volts /12 volts batteries complete all as specfied and directed. 78 S& F of flywheel ring for320 KVA capacity DG Set all as per specified and directed. 79 Repair/servicingof radiator assembly of160 KVA DG Set (Greaves/Kirloskar/Cummins) after dismantling and removing cooling fans, guard plates and lowering the same from engine after draining out water from radiator and scrapping / removing sludge / scale inside tank with acid including replacement MS tank (bottom portion) at rusted portion by cutting/ welding / brazing with 2mm thick copper plate including painting remounting the same at its original position and replacement of pre-mixed coolent and testing complete all as directed by Enginer-in-Charge.(Note- Pre mixed coolent shall be measured and paid separately under relevant item of schedule) 80 Repair/servicingof radiator assembly of320 KVA DG Set (Greaves/Kirloskar/Cummins) after dismantling and removing cooling fans, guard plates and lowering the same from engine after draining out water from radiator and scrapping / removing sludge / scale inside tank with acid including replacement MS tank (bottom portion) at rusted portion by cutting/ welding / brazing with 2mm thick copper plate including painting remounting the same at its original position and replacement of pre-mixed coolent and testing complete all as directed by Enginer-in-Charge.(Note- Pre mixed coolent shall be measured and paid separately under relevant item of schedule) 81 S&Fin replacement of HRC fuse DIN type breaking cap 100 to 200 Amp with fuse base for DIN type HRC fuse links.Make- L&T/ C&S/ Legrand 82 S&Fin replacement of HRC fuse DIN type breaking cap 220 to 380 Amp with fuse base for DIN type HRC fuse links.Make- L&T/ C&S/ Legrand 83 S&Fin replacement of HRC fuse DIN type breaking cap 400 to 600 Amp with fuse base for DIN type HRC fuse links.Make- L&T/ C&S/ Legrand 84 Supply and fixing in replacement of automatic digital control unit with display of DG set parameters. Make-Kirloskar/Procom or as approved by GE. 85 S&F in replacement of MCCB ,four pole 100 Amp current rating and ultimate breaking capacity ICS=100 % Icu 16 KA with thermal magenetic realese and adjustable overload setting having type DPX3 confirming to IS 13947 & IEC- 60947 complete all as specified and directed. 86 S&F in replacement of MCCB ,four pole 160 Amp current rating and ultimate breaking capacity ICS=100 % Icu 25 KA with thermal magenetic realese and adjustable overload setting having type DPX3 confirming to IS 13947 & IEC- 60947 complete all as specified and directed. 87 S&F in replacement of MCCB ,four pole 250 Amp current rating and ultimate breaking capacity ICS=100 % Icu 36KA with thermal magenetic realese and adjustable overload setting having type DPX3 confirming to IS 13947 & IEC- 60947 complete all as specified and directed. 88 S&F in replacement of off load change over switch 4 pole 415 volts 200 Amp rating advance neutral, open execution handle assembly having door interlock and padlocking arrangement complete all as directed by engr In charge .Make :- Hager, cat part No. : H 14541 or equivalent inC&Selectric/Schneider 89 S&F in replacement of off load change over switch 4 pole 415 volts 400 Amp rating advance neutral, open execution handle assembly having door interlock and padlocking arrangement complete all as directed by engr. In charge. 90 S&F in replacement of digital voltmeter (0.5) 3 phase 0 to 500 volts mains opetated having 2.5 digit LED/LCD/FND display mounting type for measuring phase volts all as per specified. 91 S&F digital ammeter (0.5) 3 phase digital meter range 0-300 Amp along with suitable size CTs having 3.5 digit LED/LCD/FND display mounting type for measuring phase volts all as per specified. Mke;- schnider cat part no. METSEDM 3110 or AE/Rishab 92 S&F in replacement of digital frequency meter (0.2)havingLED/LCD/FND display mounting type for 50-60 hzall as per specified. Mke;- schnider cat part no. METSEDM 1310 or AE/Rishab 93 S&F in replacement of self sequentional starting relay unit 24 voltsDC with dual interlocking timer for self on ,(3 sec-15 sec) adiacent independently with another timer for set fails to starety alarm all specified. Make ;- BCH/procom or equivalent as approved by GE. 94 S&F in replacement of LED illuminating flush push buttons 22.5 mm dia in three coloures as red ,yellow & blue without contact block and carrier all as specified. Make:- BCH/C&S/ Rishab 95 S&F in replacement of LED pilot lamp head 22.5 mm dia in three colours as red, yellow. And blue without contact block and carriers all as specified . Make :- BCH/C&S/rishab 96 S&F in replacement of plug in relay universal type 11 pin contact rating 10 amps 24 volts DC and mechanical indicator with manual testing /latching lever complete all as specified. Make :- BCH cat no. ARPU2 24 D or equilent in C&S/rishab 97 S&F in replacement of plug in relay universal type 11 pin contact rating 10 amps 12 volts DC and mechanical indicator with manual testing /latching lever complete all as specified. Make :- BCH cat no. ARPU2 230 D or equilent in C&S/rishab 98 Disconnecting and taking out of unservicable control wiring indicators, meters, fuses, selector switch, contactors ,timer,relays,CTs MCCBs etc of AMF panel of any description of 160 KVA to 320 KVA capacity DG Set. Opening of AMF panel, checking AC/DC citcuits and replacement of unservicable control wiring with 1.5 sqmm ,single core, copper counductor ,flexible,PVC insulated,unsheated cable suitable upto 1100 volts confirming to IS-694: taking out, ,removing and replacement of unserviceable parts /spare/items,re-assembling control the panel & shape in either side by increasing or decreasing strip up/down to required length by mean of soldering /brazing/welding or cutting including copper nuts,bolts & washers to fix the contactor assembly/MCCB etc in panel. testing the AMF panel on full load after completion of repair etc complete all as specified and directed by engr in charge . Note:- The Quoted rates of the contractor shall deemed to be included for fixing the servicable parts in position . The new replaced parts shall be measured and paid for seperately under appropriate items of sch Á but quoted rates are inclusive of replacement of small / minor parts such as nut ,bolts, washers / lugs / gaskets etc. 99 S&F in replacement of 3 pole AC control power contactor,415 volts, . Phase 50 Hz rated operational current 70 to 100 amp. & AC 3 rating confirming to IEC-60947 in AMF Panel as directed .Make :- Schneider reference to cat part No. LCIE 95 or equivalent in legrand/ABB/L &T 100 S & F in replacement of 3 pole AC control power contactor,415 volts, . Phase 50 Hz rated operational current 200amp. & AC 3 rating confirming to IEC-60947 in AMF Panel as directed .Make :- Schneider reference to cat part No. LCIE 160 or equivalent in legrand/ABB/ L &T 101 S & F in replacement of 3 pole AC control power contactor,415 volts, . Phase 50 Hz rated operational current 260 AMP to 300 amp. & AC 3 rating confirming to IEC-60947 in AMF Panel as directed .Make :- Schneider reference to cat part No. LCIE 300 or equivalent in legrand/ABB /L &T 102 S & F in replacement of 3 pole AC control power contactor,415 volts, . Phase 50 Hz rated operational current 400 amp. & AC 3 rating confirming to IEC-60947 in AMF Panel as directed .Make :- Schneider reference to cat part No. LCIE 400 or equivalent in legrand/ABB/L&T 103 S & F in replacement of 3 pole AC control power contactor,415 volts, . Phase 50 Hz rated operational current 630 amp. & AC 3 rating confirming to IEC-60947 in AMF Panel as directed .Make :- Schneider reference to cat part No. LCIE 630 or equivalent in legrand/ABB/L&T 104 S & F in replacement of contactor coil MNX-140 Make- L &T/BCH or equivalent as approved by GE. 105 M&L for Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including(earth pit not less than 2.25 mtr below normal ground level) with top edge of earth plate not less than 1.5 mtr below normal ground level connected to GI earth lead 25x5mm as earth lead a by means of bolts, nuts, check nuts and galvanised iron or steel including earth work in any type of soil, GI funnel with GI mesh charcoal salt 15cm alternate layer and around the earth plate, 20 mm dia watering pipe medium grade 1.70 mtr long GI protection pipe light grade 40mm dia from earth pit to main board and providing masonry enclosure with cover plate having locking arrangement, necessary pit 1:3:6 type C1 with cover of RCC 1:2:4 type B1 re-inforced with 6mm dia MS bars 75mm centre to centre, 10mm dia handle, and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 106 M&L for earth continuity conductor providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia GI pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. 107 Supply & Fixing in replacement, retro reflective installation board made out of acrylic sheet, size 1.2 x 1.0 Mtr.Writing with computer graphic marking, size of letter not more than 50 mm in length with approved white letter writing on blue back and border of 10mm all around including necessary grouting the installation board with PCC 1:2:4 with 20mm graded stone aggregate upto the depth of not exc. 50mm from ground level and to the ground with angle iron of size 40x40x6mm complete with necessary frame work, welding, bending etccomplete all as specified and as directed by the Engr-in-Charge. 108 Supply, Installation, testing and commissioning of indoor type 320 KVA AMF Panel, CPRI tested (IP-65, conforming to IS /IEC 61439 -1&2, with 65 KA 1 sec,) made out of sheet 2mm sheet, front and back openable, with proper locking arrangement, Panel size 1500 X 700 X 550 mm, Aluminum bus bar 600 Amps, 4 Pole, (Cross section area 1 sq mm=1 amp.) duly insulated with color coated heat shrinkable sleeves and shall be mounted on suitable size/rating of epoxy resin insulator. Provision of aluminum earthing strip, size: 25 X 5 mm throughout the panel at bottom, Angle base frame 50x50x5mm of height 45 cm above from ground. Panel shall be suitable for 3 phase 4 wire 415 volts AC supply, 50 HZ, dust weather and vermin proof. Panel shal be powder coated siemens grey shade No. 7032. The panel shall consist of following components(a) AMF Relay microprocessor ( Procon make ) - 01 No(b) Suitable Control material - Lots(c) Contactors MNX-650 Amp. (L&T) -02 Nos 109 Supply of indoor type 160 KVA AMF Panel, CPRI tested (|P-65, conforming to IS I IEC 61439 -1&2, with 65 KA 1 sec,) made out of sheet 2mm sheet, front and back openable, with proper locking arrangement, Panel size 1500 X 700 X 550 mm, Aluminum bus bar 400 Amps, 4 Pole, (Cross section area 1 sq mm=1 amp.) duly insulated with color coated heat shrinkable sleeves and shall be mounted on suitable sizelrating of epoxy resin insulator. Provision of aluminum earthing strip, size: 25 X5 mm throughout the panel at bottom, Angle base frame 50x50x5mm of height 45 cm above from ground. Panel shall be suitable for 3 phase 4 wire 415 volts AC supply, 50 HZ, dust weather and vermin proof. Panel shall be powder coated siemens grey shade No. 7032. The panel shall consist of following components(a) AMF Relay microprocessor ( Procon make ) - 01 No(b) Suitable Control material - Lots(c) Contactors MNX-300 Amp. (L&T) -02 Nos 110 S&F in replacement MCB SP 6 to 32 Amps 10 KA C Series,240 V all as specified. 111 S&F in replacement MCB SPN 20-32 Amps 10 KA C Series,240 V all as specified. 112 S&F MCB SPN 40 to 63 Amps 10 KA , C Series 240 V all as specified . 113 S&F MCB TPN 63 to 100 Amps 10 KA C Series 415 Volts all as specified . 114 Taking down unserviceable Sub main wiring and M & L for wiring with two single core PVC FRLSinsulated cable 4 sqmm (Nominal dia) copper conductor multistrand and drawing in and including S&F PVC concealed conduit 20 mm dia ISI marked, 1X4 sqmm multistrand copper conductor PVC FRLS green unsheathed cable for earth continuitycomplete all as specified and directed. 115 Taking down unserviceable Sub main wiring and M & L for wiring with two single core PVC FRLSinsulated cable 6 sqmm (Nominal dia) copper conductor multistrand and drawing in and including S&F PVC casing caping 25 mm width ISI marked, 1X6 sqmm multistrand copper conductor PVC FRLS green unsheathed cable for earth continuitycomplete all as specified and directed. 116 Taking down old unserviceable cable and supply & lay / passing through pipes cable FR PVC insulated & PVC unsheathed 650 / 1100 Volt Grade As per IS 694 multistranded copper conductor of size 3 core 1.5 Sq mm. for interconnection of cable looping box to street light fitting/post top lantern / security light etc in and including PVC conduit 19 mm internal dia. all as directed. 117 Taking down old unserviceable cable and supply & lay / passing through pipes cable Heat Resistant Flame Retardant HRFR PVC Insulated Industrial Cables Havells Single Core HRFR PVC Insulated Industrial Grade Copper Conductor (Unsheathed)Flexible Cables, 1100 Volts Conforming to IS: 694 1.5 Sq mm all as directed. 118 Taking down old unserviceable cable and supply & lay / passing through pipes cable Heat Resistant Flame Retardant HRFR PVC Insulated Industrial Cables Havells Single Core HRFR PVC Insulated Industrial Grade Copper Conductor (Unsheathed)Flexible Cables, 1100 Volts Conforming to IS: 694 2.5 Sq mm all as directed. 119 S & F installation , testing and commissioning in repair of pressure die-cast aluminiumhousing with high power LED bldg security light fitting with IP-66 , 1x 30 Watt , fixed in position with and including 40 mm dia light grade GI Pipe made to shape not less then 1.2 Mtr long for mounting fitting with and including suitable size duly painted MS FI 40 x6mm clamps with nut and bolts , washers making electrical connection with and including three core 16/0.20 mm copper conductor flexible cable from connector to fitting complete all as specified and directed 120 Supply, laying, jointing and testing XLPE/ P.V.C insulated, armoured, heavy duty, aluminum conductor cable 1100 volts grade of any description and any make laid in trenches/ducts, floors, fixed to wallsincluding taking out old unservicable cable etc. complete all as specified and directed by the Engineer-in-charge for the following sizes:- 121 16 Sqmm 4core 122 25 Sqmm 4core 123 35 Sqmm 3.5core 124 50 Sqmm 3.5core 125 70 Sqmm 3.5core 126 95 Sqmm 3.5core 127 150 Sqmm 3.5 core 128 Excavation in trenches in soft & loose soil not exceeding 1.5 metre deep and not exceeding 1.5 mtr width and getting out soil including forming bottom surface to required slope/gradient forlaying cables/pipes etc.all as specified and directed by Engineer-in-Charge including removing cable protection PCC covers/ bricks & stacking serviceable covers / bricks for reuse and disposal of unserviceable covers within 50 m all as specified and directed.Note : Excavation shall be made carefully in order to avoid damage of existing cables and protection covers. 129 Returning, filling in including spreading, leveling, watering and well ramming in layers of25 cm thickafter the cables etc. are laid, jointed & tested complete all as specified and directed 130 Removal of surplus excavated soilexc. 50 mtr butn. exc. 250 mtr distance and depositing where directed by Engineer-in-Charge at a level not exceeding 1.5 M above the starting point etc complete all as directed. 131 M & L for sand filling with clean dry fine sand unwashed including gently punning around cables in trenches for cable protection complete all as specified and directed .NOTE: - Punned thickness shall be measurement & paid. 132 Supplying & Laying Sub Class `B’ bricks old size with axis of the bricks perpendicular to the axis of the cable as in cable protection all as specified and directed 133 Supply and fix in replacement of3 Pole MCCB,100 Amp, 50 Hz, 415 V with rupturing capacity 16 KA complete all as specified and as directed. 134 All as per item No 91.00 above but MCCB of cap 3 Pole 160 Amp, 25 KA 135 All as per item No 91.00 above but MCCB of cap 3 Pole 200 Amp, 25 KA 136 All as per item No 91.00 above but MCCB of cap 3 Pole 250 Amp, 25 KA 137 All as per item No 91.00 above but MCCB of cap 4 Pole 400 Amp, 36 KA 138 Supply and fix in replacement of FIP assy for DG set of cap 160 KVA to 320 KVA all as specified and directed by Eng-in-charge. Make- Crompton/Kirloskar 139 Dismantling and calliberation of fuel pump ofDG Set of any capacity including replacement of seal and kit includingrefixing and testing complete. 140 Supply and fixing in replacement of water pump assy complete all as directed. 141 Dismantling and taking down alternator assembly from existing engineand carry out servicing / maintenance of alternator unit of capacity 160/320 KVA DG set as per the phase work :- (a) Opening of Alternator and cleaning / removing dust from armature and field coil. (b) Cleaning of used / old lubricated substances drive/non drive end bearings.(c)Cleaning end checking of AVR unit (d) Checking and tightening of coupling bolts and replacement of rubber gasket. (e) M&L for carrying out heat varnishing for field and armature coil and kept in heating chamber for 48 hours for drying properly.(f)Replacement of Bearings as per existing size. (g) Reassembling complete unit and carrying out testing at workshop and transportation to installation and coupling with DG Set including necessary alignment, cable connections all as specified and directed by Engr - in Charge 142 S&F in replacement of of self starter 24 volts type Suitable for DG set 320 KVAmake :-lukas/boscop or equivalent as approved by GE. 143 S&F in replacement ofself starter 12 volts Suitable for DG set 160 KVA make :-lukas/boscop or equivalent as approved by GE. 144 M&L for repair to 24 volts self starter assembly by taking out from DG Set of any make and size including transporting the same to work shop in market for repair and replacement of new items like armature, field coil with enameledcopper conductorof existinggauge including insulating material and heat varnish ,DE bearing bush, CE bush armature, carbon brush including petrol wash all as specified. Refixing the same after repair and testing on full loadcomplete all as specified and directed. 145 All as per item no. 102.00 above but for 12 volts self starter assembly all as specified. 146 S&F in replacement of AVR suitable for 160 KVAcapacity DG set complete all as specified and directed. Make- National or equivalent. 147 S&F AVR suitable for 320 KVAcapacity DG set complete. Make- National or requivalent as approved by GE. 148 S&F in replacement of existing voltage relay 415 volt 3 phase . Make- Teknika/procom/ milinec 149 S&F in replacement of multi controlrelay as per existing sample. Make- Teknika/procom/ milinec 150 Supply, laying, jointing and testing XLPE/ P.V.C insulated, armoured, heavy duty, aluminum conductor cable 1100 volts grade of any description and any make laid in trenches/ducts, floors, fixed to walls etc. complete all as specified and directed by the Engineer-in-charge for the following sizes 151 10 Sqmm 2core 152 10 Sqmm 4core 153 16 Sqmm 4core 154 25 Sqmm 4core

Key Value

Document Fees
INR 500 /-
Tender Value
INR 49 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail