Tender For Repair/ Maintenance Of Geysers, Solar Water Heater, Summer Appliances, Dg Set, Amf Panel, Electrical Infrastructure, Periodical Servicing/ Inspection Of Various Earthing System & Certain Misc E/M Works At Aftc, 2 Dc Area, Cqae (We) & Afs East West Jalahalli; 1 Inspection, checking adjustments and minor repairs of storage water heater 25/50 ltr capacity of any type any make vertical/ horizontal type which includes the following :-(a) Inspection, taking out of drain plug & dewatering and re-fixing the same complete all as directed .(b) Checking water tightness of storage tank . (c) Checking stop cocks with outlet/inlet pipe of geysers, pressure reducing valves etc to ensure free movement of water and easy functioning of parts.(d) Inspecting over flow vent pipe connections to ensure water-tightness and proper flow.(e) Checking and correct earth continuity of electrical items.(f)Checking functioning of heating elementand correct setting adjustment of thermostat.(g) Adjustment of reducing valves, checking of dead weight type high pressure release valve and visual check of fusible plug for its intactness.(h) Replacement of defective spares shall be measured and paid under relevant items mentioned below separately as supply and fix. 2 Note : The following deemed to be inclusive in quoted rate :- 3 The above job shall be carried out by a trained electrician having ITI in electrical, documentary proof of the education of tradesman shall be produced to the Engr-in-Charge before commencement of work. 4 In case of major defects, entire job shall be completed within 15 days from the date of registration of complaint, failing which penalty charges @100/- per day shall be recovered. 5 In case of minor defects, entire job shall be completed with in 12 hrs from the time of registration of complaint, failing which penalty charges @ 50/- per job shall be recovered. 6 The entire job will be carried out in entire area of Air Force stn Jalahalli 7 All types of T&P, PVC insulation tape, minor nuts, bolts, washers etc required for maintaining the services shall be provided by contractor without any extra cost to the department. 8 Supply and fixingHeating element1.5 KW 230 volts (ISI marked) suitable for 25/50 ltrs geysers any type and any make including taking down old one including washer/ packing suitable complete all as specified and as directed. 9 Supply and fixingPVC connection for hot/ cold water made of double layer nylon braided and fabric at a pressure of 6kg/sq cm at both ends, 450 mm long, heavy duty with CP brass adopters, washers, suitable for 15 mm bore pipe including taking down existing one complete all as specified and as directed. 10 Supply and fixingin replacement pressure relieving valve CP brass confirming to relevant IS with washer suitable for 15mm bore GI pipe suitable for 25/50 ltrs geysers complete all as specified and as directed. 11 Material and labour forCutting and screwing existing steel water tubing 15/20/25 mm bore for addition /alteration required for connections to geysers etc including taking down existing one complete all as specified and directed. 12 Supply and fixingin replacement thermostat switch range of 30-80 degree celsiussuitablefor geysers of 25/50 ltrs capacity (ISI marked) complete all as specified and as directed. 13 Supply and fixingin replacement brass non return valves, screwed down, high pressure, screwed both ends for 15mm bore iron pipe or for union, ISI marked, complete all as specified and as directed. 14 Supply and fixingOuter body of MS sheet not less than 20 gauge suitable for 25 ltr geyser with white synthetic enamelled paint including taking down existing one complete all as specified and as directed. 15 Material and labour for Grouting 4 Nos of M12 X100mm bolt in stone /brick masonry wall with 1:4 CM suitable for hanging geysers complete all as specified and as directed. 16 Supply and fixing Indicator lamp for geyser 25/50 ltr capacity ofcolour green & red complete all as specified and as directed. 17 Supply and fixingHeating element2.0 KW 230 volts, ISI marked suitable for 25/50 ltrs geysers of any capacity ,any type and any make including taking down old one including washer/ packing suitable complete all as specified and as directed. 18 Supply and fixingin replacement bottom cover of MS sheet 20 gauge suitable for 25 ltrs capacity geysers and providing a coat of red oxide to inner surface and applying one coat of synthetic enamel paint by spray painting to outer surface complete all as specified and as directed. 19 Material and labourfor painting of outer surface of 50 ltrs storage type water geysers after cleaning of dust & other organic/inorganic materials if any and applying one coat of synthetic enamel white paint by spray painting and writing MES No. on the geyser complete all as specified and as directed. 20 Taking down carefully storage water heater (geyser) 25 ltr capacity of any type, any make from the location by removing the electric & water supply connection and shifted to work shop/MES store yard for repair and re-installation at any location including Supply and fixingin repair of heavy duty pin type fastener 4 long and making necessary inlet/outlet electric & water supply connection from existing source to geyser complete all as specified and as directed.Note :- Adjustment of reducing valves, checking of dead weight type high pressure release valve and visual check of fusible plug for its intactness. 21 Supply and installwater heater storage type (Geyser) vertical of capacity 25 Ltr, suitable for high pressure up to 8 barpowder coated metal body, temperature indicating dial , glass line coated tank, magnesium anode,efficient long life copper heating element, wattage 2 KW electrically operated, AC 230 Volt, BEE5 Star Rated with complete fittings/partsand accessories for fixing on wall/surfaceall as per site requirement andspecified anddirected Make:- Bajaj / Racold / Havells 22 Material and labourfor painting of outer surface of 25 ltrs storage type water geysers after cleaning of dust & other organic/inorganic materials if any and applying one coat of synthetic enamel white paint by spray painting and writing MES No on the geyser complete all as specified and as directed. 23 Taking down carefully storage water heater (geyser) 50 ltr capacity of any type, any make from the location by removing the electric & water supply connection and shifted to work shop/MES store yard for repair and re-installation at any location including Supply and fixingin repair of heavy duty pin type fastener 4 long and making necessary inlet/outlet electric & water supply connection from existing source to geyser complete all as specified and as directed.Note :- Adjustment of reducing valves, checking of dead weight type high pressure release valve and visual check of fusible plug for its intactness. 24 Dismantling carefully solar storage water heating system of 100/200/300 Ltr capacity any type for following works withtestingand refixing the same in original position making all water/ electric connection to entire satisfaction of Engineer-in-charge after repair as under :-(a) Inspection, opening, of all parts,descaling, washing of inner tankwith chemical solution and cleaning ofouter cover storage tank.(b) Checking water tightness of storage tank after cleaning.(c) Checking and correcting earth continuity of electrical items.(d) Adjustment of reducing valves, checking of dead weight type high pressure release valve and visual check of fusible plug for its intactness. (e) Replacement of damaged solar cells(f)Necessary T&P such as ladder, helper shall be contractor responsibility. 25 Note : The following deemed to be inclusive in quoted rate :- 26 The above job shall be carried out by a trained electrician having ITI in electrical, documentary proof of the education of tradesman shall be produced to the Engr-in-Charge, before commencement of work. 27 In case of major defects, entire job shall be completed within 15 days from the date of registration of complaint, failing which penalty charges @ Rs. 500/- per day shall be recovered. 28 In case of minor defects, entire job shall be completed with 12 hrs from the time of registration of complaint, failing which penalty charges @ Rs. 100/- per job shall be recovered. 29 The entire job will be carried out in entire area of Air Force stn Jalahalli 30 Necessary T&P such as ladder, helper shall be contractor responsibility. 31 All types of T&P, PVC insulation tape, minor nuts, bolts, washers etc required for maintaining the services shall be provided by contractor without any cost to the department. 32 Supply and replacement of solar tube as per existing type complete all as specified and directed. 33 Supply and fixingin replacement thermostat switch suitable for solar water heater of any make and size complete all as specified and as directed. 34 Supply only solar cells to replace the damaged cells in thesolar panel for solar water heater 200 Ltr capacitycomplete all as specified and directed. 35 Gasket setfor solar water heater panel suitable for 100Ltr capacity complete all as specified and directed. 36 Supply and fixingin replacement bib taps, cast copper alloy, with crutch or butterfly handle, chromium plated, fancy type, screwed down, screwed for 15mm bore iron pipe, ISI marked, complete all as specified and as directed. 37 Supply and Fix in replacement of solar water heater tank 100 ltr capacity tank should be 1.60 mm thickness low carbon steel with porcelain coating, outer tank should be 0.4 mm thickness stainless steel 202 grade Non Magnetic grade, insulation in PUF 50mm including provn for suitable solar tubes complete all as specified and directed.Note :- Solar tubes shall be measured and paid separately 38 Supply and replace solar panel glass suitable for 100 ltrs capacity solar water heater with gasket complete all as specified and directed. 39 Supply and fixing Stop valves, 15 mm bore of pipe fancy type, chromium plated , high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed. 40 Supply only solar cells to replace the damaged cells in thesolar panel for solar water heater 100 Ltr capacity complete all as specified and directed. 41 Supply and fix in replacementrotational moulded polyethylene water storage tank of 300 litres capacity three layered HDPE water storage tanks cylindrical vertical with closed top as per IS 12701-1996 hoisted and fixed in position, including provn of inlet pipe, over flow pipe, washout pipe etc complete all as specified and directed. 42 Material and labourforStaging / steel frame work for Solar water tanks using standard mild steel sections like angle iron / MS pipe / flat iron / sheets etc using steel of Fe 410-W (Gde E-250) quality - A including necessary welding suitable to keep 300 ltrs PVC water tank in repairs complete all as specified and directed. 43 M&L for Preparing new steel surfaces of any description over 10cm in width or girth , not otherwise described and applying two coats of Synthetic enamel Paint over a coat of red oxideprimer complete all as specified and directed. 44 Supply and fixing 15mm bore galvanized steel water tubing, medium grade with all fittings and fixed complete to walls and ceiling or laid in floors including taking up or down old steel tubing and connection complete all as specified and directed.. 45 Supply and fixingin repair 20 mm dia Chlorinated PVC (CPVC) Pipes of pressure rating 10kgf/cm2including fittings like socket / union / Tee / Reducer / Nipple etc complete fixed to wall/ceilings/ in floors etc, complete all as specified and directed. 46 Supply and fixingin repair Chlorinated PVC (CPVC) Gate Valve of size 20 mm dia, (ISI marked) complete all as specified and as directed. 47 Supply and fixingin repair 25 mm dia Chlorinated PVC (CPVC) Pipes of pressure rating 10kgf/cm2including fittings like socket / union / Tee / Reducer / Nipple etc complete fixed to wall/ceilings/ in floors etc, complete all as specified and directed. 48 Supply and fixingin repair Chlorinated PVC (CPVC) Gate Valve of size 25 mm dia,( ISI marked) complete all as specified and as directed. 49 Supply and fixingin repair 32 mm dia Chlorinated PVC (CPVC) Pipes of pressure rating 10kgf/cm2including fittings like socket / union / Tee / Reducer / Nipple etc complete fixed to wall/ceilings/ in floors etc, complete all as specified and directed. 50 Supply and fixingin repair Chlorinated PVC (CPVC) Gate Valve of size 32 mm dia,( ISI marked) complete all as specified and as directed. 51 Supply and fixingin repair 40 mm dia Chlorinated PVC (CPVC) Pipes of pressure rating 10kgf/cm2including fittings like socket / union / Tee / Reducer / Nipple etc complete fixed to wall/ceilings/ in floors etc, complete all as specified and directed. 52 Supply and fixingin repair Chlorinated PVC (CPVC) Gate Valve of size 40 mm dia,( ISI marked) complete all as specified and as directed. 53 S&F in repair PVC insulated and FRLS PVC Round Sheathed, Copper Conductor (flexible) industrial cable, 1100 Volt, 2.5 Sqmm 3 core,complete all as spcified and directed. Make : Havells/ Polycab/ Plaza 54 Taking down ofexhaust fan any size/capacity after disconnecting cable connection, and refixing same in original position after necessary repair/over hauling including replacement of parts of minor nature such as screws, lugs, insulation tape, nuts, bolts, washers etc after cleaning the metal surface, greasing/lubricant etc to make it functional andmaking connection by replacing PVC insulated unsheathed cable of copper conductor of size 1.5 Sqmm from ceiling rose/ connector fan (minimum 0.50 Mtr length) aredeemed to be inclusive in quoted rate all as specified and as directed. Note:- (a)Rewinding, and materials to be replaced are measured separately.) 55 (b)The above job shall be carried out by a trained electrician having qualified in ITI ( electrician Trade), documentary proof of the education of tradesman shall be produced to Engr-in-Charge before commencement of work. 56 (c)Defective unserviceable part like fan bush,bearing etc. will be paid under respective item here-in-after as supply only through proper documentation. 57 (d)The entire job will be carried out inAir Force stn Jalahalli 58 (e) Necessary T&P such as ladder, helper shall be contractor responsibility. 59 (f)All types of T&P, PVC insulation tape, minor nuts, bolts, washers etc required for maintaining the services shall be provided by contractor without any extra cost to the department. 60 (g)Any fan found defective/not working shall be brought to AGE E/M store yard & re-fixed after repairing. 61 (j)In case of major defects, entire job shall be completed within 10 days from the date of registration of complaint, failing which penalty charges @100/- per day shall be recovered. 62 (k) In case of minor defects, entire job shall be completed with 12 hrs from the time of registration of complaint, failing which penalty charges @ 50/- per job shall be recovered. 63 Supply only 3.15 mfd capacity exhaust fan condenser complete all as specified and directed. 64 Supply only fan bush of suitable size for exhaust fan of the any sweep complete all as specified and directed. 65 Supply only fan bearing of suitable size for exhaust fan of 250mmsweepincluding greasing complete all as specified and directed. 66 Supply only metal louvers of suitable size for exhaust fan of the 250mmsweep complete all as specified and directed. 67 Supply only 2.5 mfd capacity ceiling /exhaust fan condensers complete all as specified and directed. 68 Supply only fan bearing of suitable size for exhaust fan of 300mmsweepincluding greasing complete all as specified and directed. 69 Supply only metal louvers of suitable size for exhaust fan of the 300 mmsweep complete all as specified and directed. 70 Supply only 4 mfd capacity ceiling /exhaust fan condensers complete all as specified and directed complete all as specified and directed. 71 Supply only fan bearing of suitable size for exhaust fan of 450mmsweepincluding greasing complete all as specified and directed. 72 Supply only metal louvers of suitable size for exhaust fan of the 450 mmsweep complete all as specified and directed. 73 M&L for cutting of hole through stone wall with the help of Core cutting machineincluding providing, fixing and removing shoring,cleaning,internal plastering and removing surplus hard core,rubbish not exceeding 50 mtrs including fixing of exhaust fan of size 250-450 mm all as specified and as directed. 74 Supply and fixingExhaust fan250 mm sweep 230/ 240 volt AC single phase PVC body1400 RPM including necessary nut, bolts / screws including taking down existing one writing MES No with synthetic enamel paint all specified and directed. Make-Havells /bajaj/ Crompton Greaves.Note:-Old Unserviceable Exhaust fan shall be deposited to MES store yard. 75 Material and labour for winding of Exhaust fan 250mm sweep of any make with super enamelled copper winding wire of existing gauge (wt of copper winding wire per fan 250 to 500 gms) including cutting and getting out old burnt winding, sleeve work, varnishing with E class insulation varnish, threading, connections with twin core copper flexible wire of size not less than0.75 mm of length not more than one meter with each fan complete all as specified and directed. Note :- (i)Old burnt wire shall be contractor’s property and necessary credit shall be recovered as per credit schedule. 76 M&L in repairfor stainless steel wire cloth 0.63 mm dia of wire and average width of aperture 1:40 mm for covering of exhaust fan hole in wall of size 450 mm X450 mm with PVC/woodenbeading fixed on wall including necessary fixing arrangement up to hight 11 mtrcomplete all as specified and directed.Note : All safety measures is the responsible of the contractor 77 Supply and fixingExhaust fan 300 mm sweep 230/ 240 volt AC single phase PVC body 1400 RPM including necessary nut, bolts / screws including taking down existing one writing MES No with synthetic enamel paint all specified and directed. Make-Havells /bajaj/ Crompton Greaves.Note:-Old Unserviceable Exhaust fan shall be deposited to MES store yard. 78 Material and labour for winding of Exhaust fan 300mm sweep of any make with super enamelled copper winding wire of existing gauge (wt of copper winding wire per fan 250 to 500 gms) including cutting and getting out old burnt winding, sleeve work, varnishing with E class insulation varnish, threading, connections with twin core copper flexible wire of size not less than0.75 mm of length not more than one meter with each fan complete all as specified and directed. Note :- (i)Old burnt wire shall be contractor’s property and necessary credit shall be recovered as per credit schedule. 79 M&L for cutting of hole through brick wall with the help of Core cutting machineincluding providing, fixing and removing shoring,cleaning,internal plastering and removing surplus hard core,rubbish not exceeding 50 mtrs including fixing of exhaust fan of size 250-450 mm all as specified and as directed. 80 Supply and fixingExhaust Fan 300 mm sweep, 230/240 volt AC single phase, heavy duty,1400 RPM, corrosion less mild steel body of motor, suitable hold fast with necessary nut, bolts / screws with louver including taking down existing one,writing MES No. with synthetic enamel paint all specified and directed. Make- Havells /Bajaj/ Almonard.Note:-Old Unserviceable domestic exhaust fan shall be deposited to MES store yard. 81 M&L for repair louver made of galvanised steel suitable for 300 mm size exhaust fan, fixed on wall including necessary fixing arrengement up to height 11 mtrcomplete all as specified and directed.Note : All safety measures shall be the responsible of the contractor. 82 Supply and fixingExhaust Fan 450 mm sweep, 230/240 volt AC single phase, heavy duty,1400 RPM, corrosion less mild steel body of motor, suitable hold fast with necessary nut, bolts / screws with louver including taking down existing one,writing MES No. with synthetic enamel paint all specified and directed. Make- Havells /Bajaj/ Almonard.Note:-Old Unserviceable domestic exhaust fan shall be deposited to MES store yard. 83 Material and labour for winding of Exhaust fan 450mm sweep of any make with super enamelled copper winding wire of existing gauge (wt of copper winding wire per fan 250 to 500 gms) including cutting and getting out old burnt winding, sleeve work, varnishing with E class insulation varnish, threading, connections with twin core copper flexible wire of size 0.0076mm of length not more than one meter with each fan complete all as specified and directed. Note :- (i)Old burnt wire shall be contractor’s property and necessary credit shall be recovered as per credit schedule. 84 Taking down ofwall mounted/Pedastal fanof size 400/450mm after disconnecting cable connection, and refixing same in original position after necessary repair/over hauling .(Note:- Repair, rewinding, over hauling and materials to be replaced are measured separately.) 85 Supply only fan bush of suitable size for wall mounted/Pedastalfan of the any sweep complete all as specified and directed. 86 Supply only fan bearing of suitable size for wall mounted/Pedastal fan of 400 mmsweep complete all as specified and directed. 87 Material and labour for winding of wall mounted fan400mm sweep of any make with super enamelled copper winding wire of existing gauge (wt of copper winding wire per fan 350 to 500 gms) including cutting and getting out old burnt winding, sleeve work, varnishing with E class insulation varnish, threading, connections with twin core copper flexible wire of sizenot less than0.75 mm of length not more than one meter with each fan complete all as specified and directed. Note :- (i) Old burnt wire shall be contractor’s property and necessary credit shall be recovered as per credit schedule. 88 Material and labour for winding of wall mounted/Pedastal fan450mm sweep of any make with super enamelled copper winding wire of existing gauge (wt of copper winding wire per fan 350 to 500 gms) including cutting and getting out old burnt winding, sleeve work, varnishing with E class insulation varnish, threading, connections with twin core copper flexible wire of size not less than0.75 mm of length not more than one meter with each fan complete all as specified and directed. Note :- (i) Old burnt wire shall be contractor’s property and necessary credit shall be recovered as per credit schedule. 89 Removing the window/ split type AC of 1.5/ 2 ton capacity of any make from any location for carrying out servicing complete as and when directed and installing back at original location, testing and commissioning complete all as specified and directed.Note :- The rate of following deemed to be included in quoted rate :-a) Cleaning the body, evaporator and condenser with detergent, combing the pins and flushing with air blowerb) Checking electrical connection, cleaning, Greasing, oiling, fan/blower motor, cleaning of air filter with blowerc) Wrapping suction and discharge pipe with foam insulation and white roll ,changing drainage pipe when necessary d)The unit rate quoted by the tenderer inclusive for Removing, servicing,installation, commissioning and testing of all equipment’s,tools and plants, and back in on final position complete (e) The work shall be done by a specialized team of Engineer/Technicians of OEM.(f) Spares will be measured and paid separately.(g) Refrigerant gas will be measured & paid separately. 90 Supply and fixing Blower of indoor unit suitable for 1.5 Ton / 2 Ton splitAC including taking down existing unserviceable one at any location complete all as specified and directed. 91 Supply and fixing Filter (in replacement) suitable for split type Air Conditioner of any make upto 2 TR capacity, including taking down existing one complete all as specified and directed. 92 Supply and fix Over load relay (in replacement) suitable for split type Air Conditioner of any make up to 2.0 TR capacity, including taking down existing one complete all as specified and directed. 93 Supply and fixingHermetic sealed/Rotory new compressor for 1.5 TR split type AC capacity including disconnecting the electrical and refrigerant connection of defective sealed unit ofsplit type ACof capacity 1.5 Ton and connection of all pipe line & charging of refrigerant and testing complete including taking down existing one complete all as specified and directed. 94 Supply and fix polyurethane foam insulation indoor to outdoor unit suitable for 1.5 Ton to 2 Ton split type A/C of any type and at any locationincluding taking down existing one complete all as specified and directed. 95 Supply and fix discharge valve suitable for 1.5 Ton/2 Ton of split type AC including taking down existing one complete all as specified and directed. 96 Supply and fixing Condenser Fan motor (in replacement) suitable for window type Air Conditioner of any make up to and including 1.5/2.0 TR capacity,including taking down existing one and complete all as specified and directed. 97 Supply and fix Suction valve suitable for 1.5 Ton/2 Ton of split type AC of existing make complete all as specified and directed. 98 Supply and fixing Blower motor (in replacement) suitable for split type Air Conditioner of any make up to 2 TR capacity including taking down existing unserviceable one, complete all as specified and directed. 99 Supply and fixing as in repair offlexible PVC pipe of suitable size for indoor unit drain water of split AC suitable for any type and any capacity complete all as specified and directed. 100 Supply and fixas in repair dummy nut of dia 3/8 suitable for 1.5 Ton/2 Ton of split type AC complete all as specified and directed. 101 Supply and fix dummynut of dia 1/4 suitable for 1.5 Ton/2 Ton of split type AC complete all as specified and directed. 102 Supply and fix as in repair dummy nut of dia 5/8 suitable for 1.5 Ton/2 Ton of split type AC complete all as specified and directed. 103 Supply and fix as in repair dummy nut of dia 1/2 suitable for 1.5 Ton/2 Ton of split type AC complete all as specified and directed. 104 Supply and fixing Remote assembly corded/cordless (in replacement) for any type and size of split type ACs, upto 2.0 TRincluding taking down existing one complete all as specified and directed. 105 Supply and fixingCondenser coil (in replacement) after disconnecting the refrigerant connection of defective condenser coil unit of split type ACupto 2.0 TRand replacing the condenser coil unit connectingthe same unit withrefrigerant connections complete including taking down existing one complete all as specified and directed. 106 Supply and fixing Front grill (in replacement) suitable for split type Air Conditioner of any make up to 2 TR capacity, including taking down existing one all as specified and directed. 107 Supply and fix MS wall bracketsuitable for fixing of out door unit of split type Air Conditioner with necessary nuts, bolts & washers and removing old unserviceable items and making good disturbed surfaces to match with the existing complete all as specified and directed. 108 Supply and fixingHermetic sealed/Rotory new compressor for 2 TR split type AC capacity including disconnecting the electrical and refrigerant connection of defective sealed unit ofsplit type ACof capacity 2 Ton and connection of all pipe line & charging of refrigerant and testing complete including taking down existing one complete all as specified and directed. 109 Supply and fix Condenser coil (in replacement) after disconnecting the refrigerant connection of defective condenser coil unit of split type ACupto 1.5 TRand replacing the condenser coil unit connectingthe same unit withrefrigerant connections complete including taking down existing one all as specified and directed. 110 Supply and fix as in repair PVCinsulated multi stranded copper conductor 3 core 2.5 sq.mm, including connecting up and taking down existing unserviceable cable of any description and size complete all as specified and directed. 111 Supply and fixing Remote sensing unit (in replacement) for upto 2.0 TR split type AC including taking down existing unserviceable one complete all as specified and directed. 112 Supply and fixindoor unit including blower fan , PCB board and all accessories capacity 1.5/2.0 Ton split type A/C including taking down existing unserviceable one any type complete all as specified and directed. 113 Material and labourfor shifting of Air Conditioner, Split type capacity up to 2 TR from existing location to new location as per user requirement and installing, toping up of gas, replacement of copper tubing connecting up, commissioning and testing complete all as specified and as directed.Note :- The rate for following works deemed to be included in quoted rate :-(a)Transportation of air conditioner any type any capacity from one to other location. (b) Fixing only base plate with necessary fixing material on stone / brick walls and as directed (c) Fixing only outdoor and indoor units as required and directed (d) Connecting indoor / outdoors units of split ACs with copper tubes, flairs nuts, warping suction and discharge lines with inclucating materials with necessary fixing arrangements such as bolts, nuts washers and clamps etc. on walls (e) fixing PVC pipes 50mm dia for outlet of outdoor units to drain out dew water with necessary clamps. (f) Fixing of wall mounting voltage stabilizer of 3 KVA to 5 KVA capacity on the wall with necessary fixing arrangements such as bolts, nuts washers and clamps etc on wall. (g) Fixing PVC hose/ PVC pipes of 15mm sizes as reqd at site with necessary junction boxes, PVC bends etc. including two length of PVC copper cables of 4 sqmm size for electrical connection of ACs. (h) No additional payment shall be made for leakage of gas occurring during shifting of Air Conditioner and topping up of required gas.(j)Fixing of copper tubing of qty of required size. 114 Supply and fixing as in repair ofCopper tubing of size 1/2 flare size conforming to relevant IScomplete all as specified and directed. 115 Supply and fixing as in repair ofCopper tubing of size 1/4 flare size conforming to relevant IS complete all as specified and directed. 116 Supply and fixing as in repairof Copper tubing of size 5/8 flare size conforming to relevant IS complete all as specified and directed. 117 Supply and fixing as in repair of Copper tubing of size 3/8 flare size conforming to relevant IScomplete all as specified and directed. 118 Supply and fix PCB board of any make for indoor unit of split AC 1.5 Ton/ 2 Tonincluding taking down existing one complete all as specified and directed. 119 Removing old unserviceablesplit type air conditioner outdoor unit frameand Supply and fixoutdoor unit frame ofthesplit type air conditioner 1.5/2 TR capacity, complete with refixing with all accessories such as hermetically sealedcompressor andcondenser unit, capacitors, relays, fan motor, duly prewired and including connecting of existing refrigerant gas piping, electrical connections and testing etccomplete all as specified and directed. 120 Supply and fix 3 pin metal clad plug top 20 Amps, AC 230 volts for any type of AC including taking down existing unserviceable one complete all as specified and as directed. 121 Supply and fix single phase single pole contactor suitable for 1.5/ 2.0 split type AC complete all as specified and as directed. 122 Supply & fix metal clad switch socket single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20A concealed in walls complete all as specified and as directed.Make : Havells/ Indo asian/ Legrand 123 Supply and fix flair nut of dia 5/8 suitable for 1.5 Ton/2 Ton of split type AC complete all as specified and as directed. 124 Supply and fix flair nut of dia 1/2 suitable for 1.5 Ton/2 Ton of split type AC complete all as specified and as directed. 125 Supply and fix flair nut of dia 3/8 suitable for 1.5 Ton/2 Ton of split type AC complete all as specified and as directed. 126 Supply and fix flair nut of dia 1/4 suitable for 1.5 Ton/2 Ton of split type AC complete all as specified and as directed. 127 Supply and fix flair nut of dia 1/16 suitable for 1.5 Ton/2 Ton of split type AC complete all as specified and as directed. 128 M&L core cutting ofof size 50 mm dia in stonewall with the help of machineand preparing surface to make goodmatching with existing surface coloured complete all as specified and directed. 129 Supply and fix overload protector forsplit AC 1.5/2 Ton TR capacity including taking down existing unserviceable one complete all as specified anddirected. 130 M&L core cutting ofof size 50 mm dia in bricks wall with the help of machineand preparing surface to make goodmatching with existing surface coloured complete all as specified and directed. 131 Material and labour for pressure testing and rectifying the leakages found in the system of window/ split type ACs up to 2 Ton capacity including vacumizing, charging and checking the gas pressure to desire level complete for satisfactory functioning complete all as specified and directed.Note: Toping up of gas shall be measured and paid separately 132 Repair and maintenance of inverter type splitAC of any capacity / any Make from any location including attending breakdown calls, routine maintenance and servicing ,testing and commissioning all as specified and directed here under :-a) Cleaning the body, evaporator and condenser with detergent, combing the pins and flushing with air blower.b) Checking electrical connection, cleaning, Greasing, oiling, fan motor, cleaning of air filter with blower.(c) Testing all copper tube ,joints, leads for any leaking and Top up with the refrigerant gas if necessary.(d)The work shall be done by a specialized team of Engineer/Technicians of OEM. 133 Supply and fix DC blower fan motor for inverter split AC of 1.5 Ton to 2 Ton capacity and including taking down existing unserviceable one of any capacity and at any location complete all as specified and directed. 134 Supply and fixingPCB board of inverter type split type ACfor 1.5 Ton/2 Ton capacity including taking down existing unserviceable one at any location complete all as specified and directed. 135 Taking out, inspection, checking adjustment and minor repair of unserviceable refrigerator 165/175/180/185/190/260/277/286/290/308/310/315/350/360/375 ltr capacity of any type any make for repair/ replacement of defective parts such as condenser, PVC pipe, loose electrical connection etc., cleaning, condenser unit of foreign particle and descaling with carbon di oxide gas to ensure smooth flow of refrigerating gas, reassembling the appliance, testing and placing in original position complete all as specified and as directed .Note :- Repair/ replacement of unserviceable parts shall be measured and paid separately complete all as specified and as directed . 136 Supply and fixingEvaporator coil, suitable for refrigerator of 260 to 308 ltrs any make size and type (in replacement)complete all as specified and as directed. 137 Supply and fixingChiller tray (in replacement) suitable for Refrigerator of any make, 260 to 308 litres capacity,complete all as specified anddirected. 138 Material and labour for Freezer compartment including door and accessories suitable for refrigerator 260, 286,308, 315 and 350 ltrs capacity refrigerator and including taking existing unserviceable one complete all as specified and as directed. 139 Supply and fixinghermetically sealed new compressor (in replacement) for 260 to 308 Ltrcapacity of refrigeratorincluding filling of refrigerant suitable and testing complete by disconnecting the electrical and refrigerant connection of defective sealed unit of Refrigerator compressor of capacity 260 to 308 litres complete all as specified and directed. 140 Supply and fixingVegetable tray (in replacement) suitable for Refrigerator of any make, 260 to 308 litres capacity,complete all as specified and as directed. 141 Supply and fixingin replacement condensing coil for refrigerator of capacity 260 to 308 Ltr complete all as specified and directed. 142 Material and labourfor pressure testing and rectifying the leakage found in the system of refrigerator of capacity 260 to 308 litres including vacuuming and charging the refrigerant gas to the desired pressure and filling new compressor oil etc. complete for satisfactory functioning complete all as specified and as directed.Note:Topping up of gas shall be measured and paid separately 143 Supply and fixingPVC shelf transparent type of tough plastic suitable for refrigerator of capacity 260 to 308 ltrs complete including taking down existing unserviceable one complete all as specified and directed. 144 Supply and fixing superior quality plastic/PVC Ice cube tray for refrigerator of capacity 260 Ltrs to 308 ltrs complete all as specified and directed. 145 Supply and fix in repair electric bulb 20 watt 230v threaded type for refrigerator of Capacity 260 ltrs to 308 ltrs complete all as specified and directed. 146 Material and labourfor pressure testing and rectifying the leakage found in the system of refrigerator of capacity 165 to 260 litres including vacuuming and charging the refrigerantgas to the desired pressure and filling new compressor oil etc. complete for satisfactory functioning complete all as specified and directed.Note:Topping up of gas shall be measured and paid separately 147 Supply and fix in repair magnetic beading for refrigerator of cap 165 ltrs to 335 ltrs complete all as specified and directed. 148 Supply and fixingEvaporator coil, suitable for refrigerator of 165 to 260 ltrs any make size and type (in replacement) complete all as specified and directed. 149 Material and labour for preparing the old painted surface of refrigeratorof capacity 165 litres to 350 litres and spray painting with synthetic enamel paint of approved colour complete all as specified and directed. 150 Supply and fixinghermetically sealed new compressor (in replacement) for 165to 260 Ltrcapacity of refrigeratorincluding filling of refrigerant suitable and testing complete by disconnecting the electrical and refrigerant connection of defective sealed unit of Refrigerator compressor of capacity 165 to 260 litres complete all as specified and directed. 151 Supply and fixingRelay, box type, suitable for refrigerator of any make 165 to 335 litres capacity (in replacement) fixed in repairs, complete all as specified and directed. 152 Supply and fixingChiller tray (in replacement) suitable for Refrigerator of any make, 165 to 260 litres capacity,all as specified and directed. 153 Supply and fixing Freezer compartment including door and accessories suitable for refrigerator 165/175 ltrs capacity refrigerator and including taking down existing one complete all as specified anddirected. 154 Supply and fixingin replacement condensing coil for refrigerator of capacity 165 to 260 Ltr complete all as specified and directed. 155 Supply and fixingin replacement Gasket, suitable for door of Refrigerator of any make, 165 to 350 litres capacity, fixed in repairs all as specified and directed. 156 Supply and fixingMulti capacitors 2 µfd for cooling appliances including taking down existing unserviceable one complete all as specified and as directed. 157 Supply and fixingVegetable tray (in replacement) suitable for Refrigerator of any make, 165 to 260 litres capacity,complete all as specified and directed. 158 Supply and fixingTimer and sensor of Refrigerator including taking down existing unserviceable one complete all as specified and as directed . 159 Supply and fixingCopper capillary tubesuitable forrefrigeratorincluding taking down existing unserviceable one, any description complete all as specified and directed. 160 Supply and fixingFilter of refrigerator including taking down existing unserviceable one complete all as specified and as directed. 161 Supply and fixingThermostat, suitable for refrigerator of any make 165 to 350 litres capacity (in replacement) all as specified and directed. 162 Supply and fixingin replacement condensing coil for refrigerator of capacity 308 to 350 Ltr complete all as specified and directed. 163 Supply and fixinghermetically sealed new compressor (in replacement) for 308 to 350 Ltrcapacity of refrigeratorincluding filling of refrigerant suitable and testing complete by disconnecting the electrical and refrigerant connection of defective sealed unit of Refrigerator compressor of capacity 308 to 350 litres complete all as specified and as directed. 164 Supply and fixingEvaporator coil, suitable for refrigerator of 308 to 350 ltrs any make size and type (in replacement)complete all as specified anddirected. 165 Servicing theVoltage Stabilizer 0.5 KVA to 2 KVA single phaseafter replacing transformer, PCB,u/s electronic parts, setting/testing of buck/boost relay, assembleback & fixing in its original position including testing for proper functioningcomplete all as specified and as directed. 166 Supply and fixingOver load protector for refrigerator including taking down existing unserviceable one any description complete all as specified and as directed.. 167 Supply and fixingStarting relay suitable for refrigerator including taking down existing unserviceable one complete all as specified and as directed 168 Supply and fixingMulti capacitors 2.5 µfd for cooling appliances including taking down existing unserviceable one complete all as specified and as directed. 169 Material and labourfor pressure testing and rectifying the leakage found in the system of refrigerator of capacity 308 to 350 litres including vacuuming and charging the refrigerantgas to the desired pressure and filling new compressor oil etc. complete for satisfactory functioning complete all as specified and directed.Note: Topping up of gas shall be measured and paid separately 170 Servicing theVoltage Stabilizer 4 KVA to 5 KVA single phaseafter replacing transformer, PCB,u/s electronic parts, setting/testing of buck/boost relay, assembleback & fixing in its original position including testing for proper functioningcomplete all as specified and as directed. 171 Supply and fixingMulti capacitors 4 µfd for cooling appliances including taking down existing unserviceable one all as specified and as directed. 172 Taking out, inspection, checking adjustment and minor repair of unserviceable water cooler 40/80/60/120/150/180 ltr capacity of any type any make for repair/ replacement of defective parts such as condenser, PVC pipe, loose water tap, float valve, loose electrical connection etc., cleaning condenser unit of foreign particle and descaling with carbon di oxide gas to ensure smooth flow of water cooler gas, reassembling the appliance, testing and placing in original position complete all as specified and as directed .Note :- Repair/ replacement of unserviceable parts shall be measured and paid separately complete all as specified and as directed . 173 Supply and fixingElectric condenser Fan motor, AC 230 volt, single phase with recommended RPM etc. (in replacement) suitable for water coolerof any make of 150/180 litres capacity, complete all as specified and directed. 174 Taking down corroded bottom portion of water cooler of 150 litres capacity and provision of 14 gauge MS sheet with suitable size angle iron frame work duly welded to the body of the water coolerincluding two coats of synthetic enamel painting over a coat of red oxide primer to match the existing colour all as specified and directed. 175 Supply and fix Stainless steel tray (in replacement) suitable for water cooler of160 to 180 Litres capacity complete all as specified and directed. 176 Supply and fixingDoor gasket (in replacement) suitable for lid of water cooler up to 150 litres capacity, complete all as specified and directed. 177 Supply and fixinghermetic sealed new compressor (in replacement) for water cooler 150 litre/Hr cooling capacityincluding disconnecting the electrical and refrigerant connection of defective sealed unit of storage type water cooler of capacity 150 litres and connection of all pipe line & charging of refrigerant and testing complete including taking down existing one all as specified and directed. 178 Supply and fixingPVC drain out pipe 32 mm dia bore (in replacement) as per existing including providing necessary GI clamps, nut bolt etc.all as specified and directed 179 Supply and fixingSelf closing push type Bib tap 15mm diamade out of cast copper alloy chromium plated (in replacement) suitable for water cooler conforming to ISI mark, including testing and leak proof etc. complete all as specified and directed. 180 Supply and fixingball brass valve high pressure 15mm dia complete fitting such as PVC polythene ball, layer check nut washer etc for water cooler of any capacity including taking down existing one all directed. 181 Supply and fix in replacement of gun metal gate valve 15mm dia including GI nipple including taking down existing one all as specified and as directed 182 Material and labourfor preparing the old painted surface of the water coolers of capacity cap 150 Litres and spray painting with synthetic enamel paint over one coat of red oxide primer including replacement of worn out nut, bolt, washer, screw and writing MES No and capacity all as specified and directed. 183 Material and labourfor pressure testing and rectifying the leakages found in the system of water cooler of capacity 150 litres and vacuuming and charging refrigerant gas and filling new compressor oil etc. complete for satisfactory functioning all as specified and directed.Note:Topping up of gas shall be measured and paid separately 184 Supply and fixingElectric condenser Fan motor, AC 230 volt, single phase with recommended RPM etc. (in replacement) suitable for water coolerof any make of 60/120 litres capacity, including taking down existing one all as specified and directed. 185 Supply and fixinghermetic sealed new compressor (in replacement) for water cooler 60/120 ltr/Hr cooling capacityincluding disconnecting the electrical and refrigerant connection of defective sealed unit of storage type water cooler of capacity 60/120 litres and connection of all pipe line & charging of refrigerant and testing complete all as specified and directed. 186 Material and labourfor pressure testing and rectifying the leakages found in the system of water cooler of capacity 60/120 litres and vacuuming and charging refrigerant gasand filling new compressor oil etc. complete for satisfactory functioning all as specified and directed.Note: Topping up of gas shall be measured and paid separately 187 Taking down corroded bottom portion of water cooler of 40/80 litres capacity and provision of 14 gauge MS sheet with suitable size angle iron frame work duly welded to the body of the water coolerincluding two coats of synthetic enamel painting over a coat of red oxide primer to match the existing colour all as specified and directed. 188 Supply and fixingElectric condenser Fan motor, AC 230 volt, single phase with recommended RPM etc (in replacement) suitable for water coolerof any make of 40/80 litres capacity, complete all as specified and as directed. 189 Supply and fix Stainless steel tray (in replacement) suitable for water cooler of 40/ 80 litres capacity all as specified and directed. 190 Supply and fixingCondensing coil suitable for water cooler of capacity 40/80 ltr/hr cooling capacity (in replacement) complete all as specified and as directed. 191 Supply and fixingEvaporator coil suitable for water cooler of capacity 40/80 ltr/hr cooling capacity (in replacement) complete all as specified directed. 192 Supply and fixinghermetic sealed new compressor (in replacement) for water cooler 40/80 ltr/Hr cooling capacityincluding disconnecting the electrical and refrigerant connection of defective sealed unit of storage type water cooler of capacity 40/80 litres and connection of all pipe line & charging of refrigerant and testing complete all as specified and directed. 193 Material and labourfor preparing the old painted surface of the water coolers of capacity of 40/80 Litres and spray painting with synthetic enamel paint over one coat of red oxide primer including replacement of worn out nut, bolt, washer, screw and writing MES No and capacity complete all as specified and as directed. 194 Material and labourfor pressure testing and rectifying the leakages found in the system of water cooler of capacity 40/ 80 litres and vacuuming and charging refrigerant gasand filling new compressor oil etc. complete for satisfactory functioning all as specified and directed.Note: Topping up of gas shall be measured and paid separately 195 Supply and fixingCarbon (filter) 12” size incl taking down old unsv complete all as specified and as directed. 196 Supply and fix in replacement of filter for water cooler of any size any make complete all as specified and as directed. 197 Supply and fixingMulti capacitors 4.5 µfd for cooling appliances including taking down existing unserviceable one complete all as specified and as directed. 198 Supply and charging of refrigerant gas R-134a to water cooler,refrigerator and deep freezer air conditioner of any type, make and capacity all as specified and directed.(i) Empty cylinder shall be returned to contractor.(ii) Payment shall be made for net weight of gas filled. 199 Material and labourfor repairing the leakage in the steel water tank of water cooler of any capacity by welding brazing/ soldering complete all as specified and directed. 200 Supply and fixingMulti capacitors 6 µfd for cooling appliances including taking down existing unserviceable one complete all as specified and as directed. 201 Material and labourfor taking down of ceiling fan of size 1200/1400mmsweep for safety checking by replacingdefective parts/painting/rewinding and re-fixing the ceiling fan after repairs, all as specified and as directed by Engr-in-charge. (Note:- The replacement of unserviceable items like capacitor, Bearings, Bush, Canopy, down rod etc. shall be made as directed which will be measured and paid separately under respective items as Supply only. However,parts of minor nature such as screws, lugs, insulation tape, nuts, bolts, washers etc after cleaning the metal surface, greasing/lubricant etc to make it functional andmaking connection by replacing PVC insulated unsheathed cable of copper conductor of size 1.5 Sqmm from ceiling rose/ connector fan (minimum 0.50 Mtr length) including cost of labour for above replacement aredeemed to be inclusive in quoted rate all as directed. 202 Note:- The following items shall be deemed to be inclusive in the unit rate quoted against Sl Item No 201(a) In each job, checking the functioning of fan including its connections, cleaning of fan, greasing of fan and mechanical check i.e. tightening of loose screw, nuts, bolts, etc are inclusive in unit quoted rate. 203 (b)The above job shall be carried out by a trained electrician having qualified in ITI ( electrician Trade), documentary proof of the education of tradesman shall be produced to the Engr-in- Charge, before commencement of work. 204 (c)Replacement of unserviceable parts like rubber bush, clamps, bolts, nuts, washers, safety pin, bearing etc shall be paid under respective item here-in-after as supply only through proper documentation. 205 (d)The entire job shall be carried out inAir Force stn Jalahalli 206 (e)Necessary T&P such as ladder, required manpower for taking down and refixing after repair shall be of contractors responsibility. 207 (f)All types of T&P, PVC insulation tape, minor nuts, bolts, washers etc required for maintaining the services shall be provided by contractor without any extra cost to the department. 208 (g)Any fan found defective/not working shall be brought to AGE E/M store yard & re-fixed after repairing. 209 (j)In case of major defects, entire job shall be completed within 10 days from the date of registration of complaint, failing which penalty charges @100/- per day shall be recovered. 210 (k) In case of minor defects, entire job shall be completed within12 hrs from the time of registration of complaint, failing which penalty charges @ 50/- per job shall be recovered. 211 Supply onlyfan bearing suitable forceiling fan 1200mm /1400 mm sweep (bearing with 8 balls shall be used ) Make:- NBC/TATA/SKF 212 Supply only rotor of ceiling fan of any size complete all as specified and directed. 213 Supply onlygun metalbush of suitable size for ceiling fan 1200mm /1400 mm sweep complete all as specified and directed. 214 Supply only fan canopies for ceiling fan size of 1200mm/1400mm sweep complete all as specified and directed. 215 Supply onlydown rod for ceiling fan with 15mm dia (of length not less than 45cm and not more than 60cm) with hanging clamps for ceiling fan complete all as specified and directed. 216 Supply only Rubber reel bushes for ceiling fan of size 1200/1400mm sweep complete all as specified and directed. 217 Supply only steel screw (for fixing of fan blade) as per site requirement for any make of ceiling fan complete all as specified and directed. 218 Supply onlyouter body of ceiling fan of any size complete all as specified and directed. 219 Supply onlydown rod for ceiling fan with 15mm dia (of length not less than 180cm and not more than 210cm) with hanging clamps for ceiling fan complete all as specified and directed. 220 Supply only U clamp for hanging ceiling fan with all nuts, bolts and washers complete all as specified and directed. 221 Supply onlydown rod for ceiling fan with 15mm dia (of length not less than 90cm and not more than 120cm) with hanging clamps for ceiling fan complete all as specified and directed. 222 Supply onlyblades (made of aluminium) suitable for 1200mm sweep ceiling fan of any make with set of screws complete all as specifiedand directed . 223 Supply only safety cotter pins 40mm to 50mm longwith nuts and bolt with washers for ceiling fan of size 1200/1400mm sweep complete all as specified and directed. 224 Supply onlyblades (made of aluminium) suitable for 1400mm sweep ceiling fan of any make with set of screws complete all as specifiedand directed. 225 Supply and fixing in replacement of unserviceableceiling fan 1200mm sweep, energy efficient BLDCISI mark withstar rating 230 Volts AC 50 Hz, single phase including provision of fixing arrangement, nut and bolt andflexible copper cable 3 core of size 1.5 sqmm not less than 0.5 m long complete including taking down existing one, writing MES No with synthetic enamel paint all as specified and as directed. Make : Havells/Bajaj/ Orient.Note:-(a)Old Unserviceable ceiling fan shall be deposited to MES store yard. 226 Material and labour for winding of ceiling fan motor 1200 mm sweep of any make with super enamelled copper winding wire of existing gauge (wt of copper winding wire per fan 350 to 500 gms) including cutting and getting out old burnt winding, sleeve work, varnishing with E class insulation varnish, threading, connections with twin core copper flexible wire of size not less than0.75 m of length not more than one meter with each fan complete all as specified and directed. (i) Old burnt wire shall be contractor’s property and necessary credit shall be recovered as per credit schedule. (ii) taking down of fan, and re hanging measured under item No. 201 separately. 227 Material and labour for winding of ceiling fan motor 1400 mm sweep of any make with super enamelled copper winding wire of existing gauge (wt of copper winding wire per fan 350 to 500 gms) including cutting and getting out old burnt winding, sleeve work, varnishing with E class insulation varnish, threading, connections with twin core copper flexible wire of size not less than0.75 m of length not more than one meter with each fan complete all as specified and directed. (i) Old burnt wire shall be contractor’s property and necessary credit shall be recovered as per credit schedule. (ii) taking down of fan, and re hanging measured under item No. 201separately. 228 Taking down aluminium/copper point wiring & including hard wood battens, surface conduit and board/ blocks etc or through conduits for light, socket or power point, fan point complete and making good the disturbed plaster surfaces of wall, floor, ceilingand painting 2 coat of white wash/distamber to match the existing surface, complete all as specified and directed. 229 M & L for Point wiring with PVC insulated FRLS 1.5 sq mm multi stranded copper conductor cable 1100 Volts grade drawn through and including surface PVC conduit/existing concealed conduit/PVC casing-caping etc as per site requirement onwalls / roofs / floors / ceiling etc and including provision of 1.5 sqmm copper cable as earth continuity conductor and connected to common earth dolly with all fitting and fixing accessories including sunk in cast iron / pressed steel terminal boxes (duly painted with two coats of anti corrosive paint out side and two coats of aluminium paint inside ) with 3.0 mm thick hylum brand laminated white bakelite sheet cover for mounting switches, sockets, fans regulators etccomplete for the following :-Make of wire: Polycab/Plaza/HavellsNote: (a) Switches, sockets outlets, Light fittngs, fans, bells & regulators shall be measured and paid for separetely). 230 All as per item No. 229here in before but forOne light point/fan point controlled by one way 5 Amp switch. 231 All as per item No. 229here in before but forOne light point controlled by two way 5 Amp switch. 232 All as per item No. 229here in before but for one bell point controlled by one way bell push. 233 All as per item No. 229here in before but forOne 3 pin socket out let 5 Ampon the same board 234 All as per item No. 229 here in before but for one switch socket outlet 3 pin 5 Amps on independent board 235 All as per item No. 229here in before but for Wiring with 2.5 Sqmm copper multistranded unsheathed cable and2.5 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently complete all as specified and directed. 236 All as per item No. 229here in before but for Wiring with 4 Sqmm copper multistranded unsheathed cable and4 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently complete all as specified and directed. 237 Supply and Fix switch piano flush type 5 Amps240 volts single pole one way, complete all as specified and directed. Make : Anchor/Havells/L&T/Indoasian 238 Supply and Fix switch piano flush type 5 Amps240 volts single pole two way, complete all as specified and directed. Make : Anchor/Havells/L&T/Indoasian 239 Supply and Fix switch piano flush type 5 Amps240 volts bell push, complete all as specified and directed. Make : Anchor/Havells/L&T/Indoasian 240 Supply and Fix shuttered socket outlet 3 pin 5 Amps, flush type, complete all as specified and directed. Make : Anchor/Havells/L&T/Indoasian 241 Supply and Fix shuttered switch socket outlet 3 pin 5 Amps, flush type, complete all as specified and directed. Make : Anchor/Havells/L&T/Indoasian 242 Supply and Fix shuttered switch socket outlet 2 in 1, 3 pin, 5 and15 Amps, complete all as specified and directed.Make : Anchor/Havells/L&T/Indoasian 243 S & F ceiling rose surface bakelight two to three terminal complete all as specified and directedMake : Anchor/Havells/L&T/Indoasian 244 S & F in repairfan regulator 120W,for ceiling fan complete all as specified and directed Make : Anchor/Havells/L&T/Indoasian 245 S & F2.5 mfd condensor for ceiling fan, complete all as specified and directed. Make : Epcos/ Asian/ Tyton 246 S & Felectric bell, AC 230 volt, single pole Ding Dong type complete all as specified and directed. Make :Anchor/Havells/L&T 247 M&L for sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 4 Sqmm drawn through in and incl suitable size surface PVC casing caping/PVC Conduit and all accessories fixed to wall/floors along with 4 Sqmm surface PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size.Note: (a)2 runs of 4 Sqmm cable along with one run of 4 Sqmm cable for earth conductor shall be measured as one lengthMake:- Havells/ Polycab/ Plaza. 248 S&F in replacementfactory madepowder coated distribution board VTPN, 4 way double doorMCCB DB includingbus bar, Neutral bar, standard DIN rail, earth bar complete including taking down unserviceable DBcomplete all as directedMake : Indoasian/ Havells/ Legrand. 249 S&F in replacement distribution board MCCB four pole, 100 Amp ultimate breaking capacity 16 KAconforming to IEC -61439-1, complete all as specified and directed. Make : Legrand/ L&T/ Indo Asian 250 Supply and Fixing in repairs of 4 feet surface mounted batten type luminaire , lumen output of 2000 lumens, high efficiency long life LED package in integral module with lumen efficacy of >100 lm/w, viewing angle not less than 120° to ensure better uniformity with an operating voltage range from 140V-270V. The luminaire shall have a white extrusion housing with a poly carbonate diffuser to provide uniform light and sleek design with width not more than 22 mm. The luminaire shall have a CRI >80, Color temperature 6500K, THD <10% and PF >0.95,SDCM<5, IP20, IK02, Operating Temperature: -10 TO + 45 DEG.C; Input Supply Voltage Range:140-270 V, Frequency :50-55 HZ. The luminaire shall have flicker content<5% and shall have high and low cut off with auto restart feature.Driver Safety requirement stds: IS 15885-2-13. The luminaire shall be EMI/ EMC compliant and shall have a internal surge protection of 4 KV. The luminaire shall have Class-1 Electrical insulation, Class-B serviceability .The luminaire and driver shall be BIS approved, complete all as specified and directed.Make : Philips/ Bajaj / CG/Havells. 251 Supply and Fixin replacement ofsurface mounted Square/Roundfor LED 18W Watt downlights made of extruded Aluminium housing and high power LED light source withDriver clear diffuser with separate electronic driver with complete accessories all as specified and directed.Make : Philips/ Bajaj/ CG/Havells. 252 S&F in replacement factory madepowder coated distribution board SPN 12 way double door,includingbus bar, Neutral bar, standard DIN rail, earth bar complete including taking down unserviceable DB conforming to IS: 8623, all as specified and directed. Make : Legrand/ L&T/ Indo Asian 253 S&F in replacement distribution board MCCB four pole, 63 Amp ultimate breaking capacity 16 KAconforming to IEC -61439-1, complete all as specified and directed. Make : Legrand/ L&T/ Indo Asian 254 S&F in repairs 35/36 W (WH) LED Surface type2x2 ft luminaire with classic design & glare free soft illumination. housing with white high reflection powder coated (RAL9016) CRCA sheet. Glare free, Opal diffuser for symmetrical light distribution fixed in separate CRCA sheet frame held in with housing by screws for easy maintenance. High efficiency long life LED package in integral module with lumen efficacy of >100 lm/w, viewing angle of 100° to ensure better uniformity. Powered by an independent Isolated, SELF Output electronic LED driver (SMPS based constant current supply) efficiency of 85% with built-in Surge protection 3Kv. System Lumen Output of 3000 lumens.Make : Philips/ Bajaj/CG/Havells. 255 S&F in repairs LED bed side light /wall light/study lightenvironmentel friendly energy effcient of capacity3 W warm whiteetc,inbuilt drivercomplete with all accessories internally pre-wired swing type and including connecting up towith twin core twisted flexible copper conductor cable with suitable size complete all as directed . Make : Bajaj/ Philips / Wipro/CG 256 Supply & Fixing in replacement of electronic LED driver 2/3 W suitable for bed side light fitting as per site requirement complete all as specified and directed . 257 M & L for Point wiring with PVC insulated FRLS 1.5 sq mm multi stranded copper conductor cable 1100 Volts grade drawn into and including concealedrigid non mettalic PVC conduit/casing caping medium grade not less than 19/20 mm ( ISI marked ) with all fitting and fixing accessories including sunk in pressed steel chromium plated terminal boxes, concealed in wall/surface/roofs/floor/ceiling etc as per site requirement and making & matching the existing surface) white bakelite sheet cover for mounting switches, Sockets, Fan regulators etc or modular cover plate with frame including sunken boxes suitableto fix modular cover plate with frame, concealed in wall or 1.5 sq mm multi stranded copper conductor cable as continuous earth wire drawn with wiring and connected to common earth dolly complete all as specified and directed for the following :- Make of wire: Polycab/Plaza/HavellsNote:Blanking plate,Modular cover plate ,Switches, sockets outlets, Light fittngs, fans, bells & regulators shall be measured and paid for separetely). 258 All as per item No. 257 here in before but for one light point/fan/bell point controlled by one wayswitch. 259 All as per item No. 257here in before but for one light point controlled by twowayswitch. 260 All as per item No. 257here in before but for one bell point controlled by one bell push. 261 All as per item No. 257 here in before but for one 3 pin socket out 5 Ampon the same board 262 All as per item No. 257 here in before but for one switch socket outlet 3 pin 5 Amps on independent board 263 All as per Sl No 257 above but Wiring with 2.5 Sqmm copper multistranded unsheathed cable and 2.5 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently etc complete all as specified and directed. 264 All as per Sl No. 257 above but Wiring with 4 Sqmm copper multistranded unsheathed cable and 4 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently complete all as specified and directed. 265 Supply and Fixmodular switch1 way 6 Amp.1 module, complete all as specified and directed.Make : Legrand/ Crabtree/ Anchor/Indoasian 266 Supply and Fixmodular switch2 way 6 Amp.1 module, complete all as specified and directed.Make : Legrand/ Crabtree/ Anchor /Indoasian 267 Supply and Fixmodular switchbell push .1 module, complete all as specified and directed.Make : Legrand/ Crabtree/ Anchor /Indoasian 268 Supply and Fixmodular Socket, 6A - 2/3 pin combined 2 module, complete all as specified and directed.Make : Legrand/ Crabtree/ Anchor/Indoasian 269 Supply and Fixmodular switch1 way 16 Amp.1 module, complete all as specified and directed. Make :Legrand/ Crabtree/ Anchor /Indoasian 270 Supply and Fix modular Socket, 16A - 2/3 pin combined 2 module, complete all as specified and directed. Make : Legrand/ Crabtree/ Anchor/Indoasian 271 Supply and fix White cover plate with frame,2/3 module 272 Supply and fix White cover plate with frame,4 module 273 Supply and fix White cover plate with frame,8 module 274 Supply and fix White cover plate with frame,6 module 275 Supply and fix White cover plate with frame,12 module 276 S & F Modular fan regulator 120W, 2 Module for ceiling fan complete all as specified and directedMake : Legrand/ Crabtree/ Anchor 277 M&L for sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 6 Sqmm drawn through in and incl suitable size surface PVC casing caping/PVC Conduit and all accessories fixed to wall/floors along with 6 Sqmm surface PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size.Note: (a)2 runs of 6 Sqmm cable along with one run of 6 Sqmm cable for earth conductor shall be measured as one lengthMake:- Havells/ Polycab/ Plaza. 278 S&F in replacement factory madepowder coated distribution board SPN 8 way double door,includingbus bar, Neutral bar, standard DIN rail, earth bar complete including taking down unserviceable DBconforming to IS: 8623, all as specified and directed. Make : Legrand/ L&T/ Indo Asian 279 S & F MCB in replacement ofSPN 240 volts 40 to 63 Amps complete including taking down unserviceable fitting complete all as specified and as directed .Make : Legrand/ L&T/ Indo Asian. 280 S&F in replacementfactory madepowder coated distribution board TPN, 4 way double doorMCBDB includingbus bar, Neutral bar, standard DIN rail, earth bar complete including taking down unserviceable DBcomplete all as directedMake : Indoasian/ Havells/ Legrand. 281 S & F in replacement TPN, MCB 40 to 63 Amp, 240 v, 50 Hz ACsuitable for ‘C’ curve, 10 KA breaking capacitycomplete conforming to IS 8828 of 1996, all as specified Make : Legrand/ L&T/ Indo Asian 282 S&F in repairs 35/36 W( WH) LED recessed type 2x2 ft luminaire with classic design & glare free soft illumination. housing with white high reflection powder coated (RAL9016) CRCA sheet. Glare free, Opal diffuser for symmetrical light distribution fixed in separate CRCA sheet frame held in with housing by screws for easy maintenance. High efficiency long life LED package in integral module with lumen efficacy of >100 lm/w, viewing angle of 100° to ensure better uniformity. Powered by an independent Isolated, SELF Output electronic LED driver (SMPS based constant current supply) efficiency of 85% with built-in Surge protection 3Kv. System Lumen Output of 3000 lumens.Make : Philips/ Bajaj/CG/Havells. 283 Supply & Fixing in replacement of electronic LED driver 35/36 W suitable for round ceiling light indoor fitting of make Philips/ crompton/ Bajaj, complete all as specified and directed . 284 Supply & Fixing in replacement of electronic LED driver 9/10 W suitable for round ceiling light indoor fitting of make Philips/ crompton/ Bajaj, complete all as specified and directed . 285 S & Fin replacement 7/9 watt LED lamp, complete all as specified and directed. Make : Philips/ Bajaj/ Crompton 286 S&F in replacement factory madepowder coated distribution board SPN 6 way double door,includingbus bar, Neutral bar, standard DIN rail, earth bar complete including taking down unserviceable DBconforming to IS: 8623, all as specified and directed. Make : Legrand/ L&T/ Indo Asian 287 S & F in replacement of MCB single pole 240 volts 6 to 32 Amps complete including taking down unserviceable fitting complete all as specified and as directed.Make : Legrand/ L&T/ Indo Asian. 288 S & F in replacement TP, MCB 40 to 63 Amp, 240 v, 50 Hz ACsuitable for ‘C’ curve, 10 KA breaking capacitycomplete conforming to IS 8828 of 1996, all as specified Make : Legrand/ L&T/ Indo Asian 289 Supply and Fixing in repairs of 2 feet surface mounted batten type luminaire , lumen output of 1000 lumens, high efficiency long life LED package in integral module with lumen efficacy of >100 lm/w, viewing angle not less than 120° to ensure better uniformity with an operating voltage range from 140V-270V. The luminaire shall have a white extrusion housing with a poly carbonate diffuser to provide uniform light and sleek design with width not more than 22 mm. The luminaire shall have a CRI >80, Color temperature 6500K, THD <10% and PF >0.95,SDCM<5, IP20, IK02, Operating Temperature: -10 TO + 45 DEG.C; Input Supply Voltage Range:140-270 V, Frequency :50-55 HZ. The luminaire shall have flicker content<5% and shall have high and low cut off with auto restart feature.Driver Safety requirement stds: IS 15885-2-13. The luminaire shall be EMI/ EMC compliant and shall have a internal surge protection of 4 KV. The luminaire shall have Class-1 Electrical insulation, Class-B serviceability .The luminaire and driver shall be BIS approved, complete all as specified and directed.Make : Philips/ Bajaj / CG/Havells. 290 Refixingexisting serviceable LED light fitting fixture any capacity and of any type complete with all accessories internally pre-wired and including connecting up to ceiling rose with twin core twisted flexible copper conductor cable of suitable size after cleaning all dust etc. completeall as specified and as directed . 291 S&F in repairs 35/36 W (WH) LED recessed type1X4 ftluminaire with classic design & glare free soft illumination. housing with white high reflection powder coated (RAL9016) CRCA sheet. Glare free, Opal diffuser for symmetrical light distribution fixed in separate CRCA sheet frame held in with housing by screws for easy maintenance. High efficiency long life LED package in integral module with lumen efficacy of >100 lm/w, viewing angle of 100° to ensure better uniformity. Powered by an independent Isolated, SELF Output electronic LED driver (SMPS based constant current supply) efficiency of 85% with built-in Surge protection 3Kv. System Lumen Output of 3000 lumens.Make : Philips/ Bajaj/CG/Havells. 292 S&F in replacement factory madepowder coated distribution board SPN 4 way double door,includingbus bar, Neutral bar, standard DIN rail, earth bar complete including taking down unserviceable DB conforming to IS: 8623, all as specified and directed. Make : Legrand/ L&T/ Indo Asian 293 S & F MCB in replacement ofSPN 240 volts 32 Amps complete including taking down unserviceable fitting complete all as specified and as directed .Make : Legrand/ L&T/ Indo Asian. 294 S & F in replacement of MCB single pole 240 volts 40 to 63 Amps complete including taking down unserviceable fitting complete all as specified and as directed .Make : Legrand/ L&T/ Indo Asian 295 Excavation in trenches not exceeding 1.5 mtr in width and not exceeding 1.5 mtr in depth and getting out for laying of cables up to proper level and laying of pipelines etcinsoft/loose soil, complete all as specified and directed. 296 Returning, filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm thick, complete all as specified and directed. 297 Removing surplus excavated material (soil) not exc 50 meter and depositing where directed at a level not exc 1.5 meter above the starting point, complete all as specified and directed. 298 Material and labour for Spreading ribbed soil in trenches as in cable cushioning all as per IS 1255-1983, complete all as specified and directed.Note :- (i)Excavated approved soil shall be ribbed by using sieve to separate composite particles etc. as per IS and refilling in trenches before laying of cable 8 CM and 15 CM after laying of cable. This is then gently punned down to a depth of 10 cm above the top of upper most cable (ii) For the purpose of measurement only punned thickness shall be considered for payment. 299 Material and labour for well burnt bricks ‘B’ class as mechanicalprotection to under ground cables laying with length of the bricks equal to the width of the trench, complete all as specified and directed. 300 Material and labour for Cutting existing road/PCC/Drain for laying of GI or any type of pipe including necessary earthwork, excavation exc 600mm depth but not exc 1mtr depth, 800 mm wide including making good existing surface with 150 mm thick PCC 1:2:4 type B1 using 20mm graded stone aggregate, complete all as specified and directed. Note :-The tenderer shall take into consideration for following points while quoting rate for this item andthe unit rate is deemed to be inclusive for :-(i) Earth work and excavation in any type of soil(ii) Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick ,complete all as specified and as directed.(iii) Removing excavated material out side MD land.(iv)Laying of any type/any bore of pipe in trenches including taking down existing unserviceable pipe. Supply of pipe shall be measured and paid separately(v)150 mm thickPCC 1:2:4 type B1 using 20mm graded stone aggregate as inroad to make good existing disturbed surfaces. 301 Material and labour in repair for 4 core 10 Sqmm XLPE insulated heavy duty electric cable with aluminium single stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laying in trenches/cable ducts, fixed to wall/pole, complete all as specified and directed. Make : Havells, Polycab, RPG Asian 302 Material and labour in repair for 4 core 16 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laying in trenches/cable ducts, fixed to wall/pole, complete all as specified and directed. Make : Havells/Polycab/RPG Asian 303 Material and labour in repair formaking straight through joint with suitablejointing kit consisting of water proof adhesivesfor UG cable of size 4 core 10 Sqmm to 16 Sqmm, complete all as specified and directed. 304 Supply only of GI pipe light grade for cable protection of size 50mm bore with fittings, complete all as specified and directed. 305 Disconnecting of burnt/ damaged cables from panels/ junction boxes etc, cutting out the burnt out ends, making new end joints by supply and fixing new aluminium lugs/ insulation tape etc and reconnecting using new nuts/ bolts/ washer etc and restoring three phase and neutral in the junction box, complete all as specified and as directed for thecable sizefrom 10Sqmmto 16 Sqmm 3.5 core of underground LT armoured cables.Note :- Earth work required for extending the incoming/ outgoing cable in junction box/ panel board etc shall deemed to be included in the unit rate quoted. 306 Supply, installation, testing and commissioning LTFeeder pillar box double door CPRI Testedof Size 400X250X350mmsuitable for 3 phase 415 Volts of suitable size out door made out 3.15mm thick CRCA sheet of outdoor of panel with angle iron frame of size 32x32x5mm cubical type complete with aluminium bus bar 100 Amp and including PCC foundation as per site requairment to accomodated to the following.INCOMING(a)MCB TPN32 Amp 10 KA - 01 No. (b)LEDindicating lampR-Y-B - 03 Nos. OUTGOING(a) Weather Proof panelPlug and shocket angled type IP 67three Phase 3P+N +E, 20 Amp - 01 No(b) Weather Proof plug and shocket angled type IP 67 Single Phase 2P+E , 20 Amp- 01 No.(a)MCB TPN20 Amp 10 KA - 01 No. (a)MCB SPN20 Amp 10 KA - 01 No. 307 M &L for PCC (1:3:6) type C1 (using 20mm graded stone aggregate) as in copping to poleincluding necessary form work slightly rounding or squaring, complete all as specifiedand as directed. 308 M & L for PCC 1:4:8 type D2 (using 40mm graded stone aggregate) as in foundation and mass concrete for poles and filling around fencing posts etc, complete all as specified and as directed 309 Supply & Erecting Mild steel tubular swaged pole 9 meter long 410, SP-31 complete with cast iron base plate, bracket, finial taper plug, bolt, nuts & screws and painted on both side (internally & externally), external surface painted with two coat of aluminum paint over coat of primer and painting with blackup to 1.5 meter from top of PCC 1:3:6 using 20 mm graded stone aggregate coping white colour paint as in strips of equal width with marking pole numbers by using one coat of synthetic enamel paint including necessary PCC 1:4:8 with 40 mm graded stone aggregate as in foundation and coping as per TD drawing including dismantling of old damaged pole complete all as specified and as directed.Note (i)Excavation, earth work and PCC work for embedding pole shall be measured and paid seperately.(ii) Pole upto 1.5 m top of copping shall be painted with 2 coats of black and white strips alternate 30cm each over one coat of red oxide primer (iii) Steel tubular pole above 1.5 m shall be painted with 2 coats of aluminium paint over a coat of red oxide primer. The rate for above items shall be deemed to be inclusive in the quoted rate. 310 Supply and fix in repair weather proof PVC junction box approved by CPRI for street light control box made out of not less than 2mm thick and size 250mm x 200 mm x 105mm (approx) complete with hinged door locking arrangement and consisting of 2 Nos of suitable size cable glands consisting of 01 No. panel mounted connector 4 pole 32A-1 No, MCB SP 6A 10KA-01No, including connecting up with the electrical connections and fixing with clamps etc complete and all as specified anddirected. 311 Supply and fix 1100 Volts grade heavy duty flat weather proof twin core cable of size 4 Sqmm with multistrand aluminium conductor including taking down of old one complete all as specified and directed. Make: Plaza/Polycab/ Finolex/Havells 312 Supply and fixing in repair LED flood light 150 watt made up of die cast aluminium housing with toughened glass and high power LEDs and secondary lenses with IP 66 protection and system efficiency ≥ 125 LPW with option for 3000K 10 KV SPD corrosion resistant complete with driver and lampProtection including street light fitting bracket nuts, bolts, washers complete, all as specified and directed. Make:Halonix/Philips/CG/Bajaj 313 Supply and fix in repair bracket for street light fitting made out of40 mm dia light grade GI tubing bent to required shape 1.5m long including necessary GI clamps, nuts bolts and washers and fixing to the pole etc complete all as specified and directed. 314 Supply and fixing in repair Round spherical garden lighting, post top lantern having B22 holder suitable for LED bulb10 watt, 220 volt,50HZ,IP65 including suitable of GI tubing ,length as per site requirement on gate pillars/ garden lights for fixing the lamp, wiring with 1.5 Sqmm PVC insulated strandedcopper conductor includingPCC work for fixing, of light fitting complete all as specified and directed.Make: Philips/ Havells/Bajaj/CG. 315 Suply and fix in repairs LED decorative post top lantern fitting 40W, 230V AC with IP 65 protection and resistant to impact and corrosion with necessary electrical connection completeall as specified as directed. Make: Bajaj / Philips/Halonix/ CG 316 Supply and fix in repair weather proof PVC junction box approved by CPRI for street light control box made out of not less than 2mm thick and size 140x140x100mm (approx) complete with hinged door locking arrangement and consisting of 2 Nos of suitable size cable glands consisting of 01 No. panel mounted connector 4 pole 32 Noincluding connecting up with the electrical connections and fixing with clamps etc complete and all as specified anddirected. 317 Supply and fix 1100 Volts grade heavy duty flat weather proof twin core cable of size 6 Sqmm with multistrand aluminium conductor including taking down of old one complete all as directed and specified. Make: Plaza/Polycab/ Finolex/Havells 318 Supply and fixing LED flood light 100 watt 230 V AC outdoor type including necessary bracket with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp including taking down of old unserviceable fitting of any capacity.Make :Bajaj/Philips/CG/Halonix. 319 Supply and fixing in repair IP65 rated LED Bollard with robust design and efficient light distribution 10 watt on existing pipe of any size and height with all accessories prewired fixed with FI clamps nuts bolts etc., including taking down existing fittings all as specified and directed Make : Crompton/ Halonix/Bajaj/ Philips 320 Suply and fix in repairs LED decorative post top lantern fitting 25 W, 230V AC with IP 65 protection and resistant to impact and corrosion with necessary electrical connection completeall as specified as directed. Make: Bajaj / Philips/Halonix/ CG 321 Supply and fix 1100 Volts grade heavy duty flat weather proof twin core cable of size 10 Sqmm with multistrand aluminium conductor including taking down of old one complete all as directed and specified. Make: Plaza/Polycab/ Finolex/ Havells 322 Material and labour in repair for 3 ½ core 25 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laying in trenches/cable ducts, fixed to wall/pole, complete all as specified and directed. Make : Havells/ Polycab/ RPG Asian 323 Material and labour in repair formaking straight through joint with suitablejointing kit consisting of water proof adhesivesfor UG cable of size 3.50 core 16 Sqmm to 25 Sqmm, complete all as specified and directed. 324 Servicing/ Periodical maintenance of following capacity DG Set of any make consisting of complete servicing and checking entire system as per manufacturers catalogue including testing complete with replacing of minorconsumables itemslike grease, nut bolts etc during conducting periodic servicing as per the manufacturers recommendation at the time of routine monthly checks. Capacity 20KVA DG Set - Location:-street lights CQAE Area - 01 No Maintenance Schedule of DG Sets :- The contractor shall carried out following activity during ofthe period of contract :- 325 (a)Daily maintenance of DG Sets to be carried out :- 326 (i) Clean the external surface of the DG set. 327 (ii)Check engine oil level. 328 (iii) Check engine coolant level. 329 (iv) Check fuel in the tank. 330 (v)Check all nuts and bolts. 331 (vi) Check tension of fan belts. 332 (vii) Check batteries and battery connections. 333 (viii)Check fuel lines and fuel tank. 334 (b)Weekly maintenance of AMF Panels :- 335 (i) Checking all electrical connections. 336 (ii)Checking all contact points/ Bus bars. 337 (iii) Checking timers (AC/ DC). 338 (iv) Checking all selector switches (voltmeter and Ammeter). 339 (v)Check RPM, Voltage, Amps and Hz. 340 (vi) Checking indicator lamps. 341 (vii) Checking main auxiliary contacts and relays. 342 (viii)Checking contact coils. 343 (ix)Checking, volt/ amps/ energy/ PF/ KWH meters/ CTs. 344 (x) Checking auto/ manual functions. 345 (xi)Check and tight screws and bolts. 346 (xii)Check battery charger output voltage. 347 (xiii) Cleaning the panel. 348 (xiv) Checking all MCCBs and fuses. 349 (xv) Checking alarms and hooter. 350 (c) Monthly maintenance of DG Sets to be carried out :- 351 (i)Check oil bath cleaner oil level. 352 (ii) Check for proper tension in the belts. 353 (iii) Check starting battery electrolyte level and specific gravity. 354 (iv) Check the fuel lines from the tank for leakages. 355 (v) Check the end cover of the alternator and tighten the bolts. 356 (vi) Check physically the exhaust silencer for rigidness. 357 (vii) Check the water hoses for leakages if any. 358 (viii) Drain sediment from fuel filter & fuel tank. 359 (ix) Check dry type air filter element and clean. 360 (x) Check engine alternator coupling and mounting bolts. 361 (xi) Tight all bolts and nuts in alternator terminal box. 362 (xii)Check for any unusual sound during cranking of the engine. 363 (xiii)Check for any fuel/ water leakages. 364 (xiv)Check for any unusual vibrations. 365 (xv)Check proper charging of battery. 366 (xvi)Check exhaust system for any leakages. 367 (xvii) Check for proper circulation of coolant/ cooling of engine. 368 (xviii) Check physically the exhaust silencer for rigidness. 369 (xix) Check throttles linkage. 370 (xx) Checking to electric control panel throttle linkage. 371 (xxi) Supply and greasing to all bearing & movable parts. 372 (d)Quaterly Schedule to be carried out :- 373 (i)Checking of hydraulic governor oil level and toping up level. 374 (ii) Clean the crank case breather. 375 (iii)Check battery charging system & topping up electrolyte and maintenance of specific gravity. 376 (iv) Checking electric connection & generator control panel. 377 (v) Greasing to all bearing and movable parts. 378 Note :- The unitrate quoted is deemed to be inclusive of the followings :- 379 (a)DG Sets are placed at various locations of CQAE (WE). Therefore,the bidders areadvised to visit the location of DG Sets before quoting the tender. 380 (b)Servicing/ repair of DG Set shall be carried out by authorised dealer/ agency of manufacturer as approved by Engineer-in-Charge and where service/ repair is being carried out at site shall be under the expert supervision of authorised service agent. 381 (c) The make of DG sets are Kirloskar/ Greaves Cotton 382 (d)Filling of DHPP (N) in all mentioned DG Sets at various locations will be the responsibility of the contractor. However, DHPP (N) will be issued by MES. The amount for filling of DHPP (N) in DG sets is deemed to be inclusive in unit quoted rate. 383 (e) DHPP (N) required at the time of maintenance/ testing will be issued by MES. 384 (f)Representative of contractor shall maintain & update the maintenance/ breakdown register regularly and same will be checked by Engineer-in-Charge periodically. 385 (g)The monthly check shall be done once in a month but whenever breakdown occurs in DG set, the contractor has to attend all complaint unlimitedly through authorised service agent of the equipment/ machinery. 386 (h)The unit rate is deemed to be included for Cleaning of the surrounding area of DG set 5 mtr from plinth protection ofE/M installations includingremoving of accumulated earthof any width and depth upto 15cm cleaning / Cutting the grass with hand operated petrol/ kerosene driven grass cutting machine andremoving thegrass waste to outside MD land. 387 (j)In case of minor defect, entire Job shall be completed within 06 hrs from the time of registration of complaint, failing which penalty charges @ Rs. 500/- per hours shall be recovered. 388 (k)In case of major defect, the period for attending of complaint shall be decided by the GE/EIC by accessing extent of repair required through joint inspectionby Engineer-in-Charge and authorised service agent of the equipment at the site. If complaint is not rectified within the stipulated period and the GE is not satisfied with the reason for delay, then penalty at the rate of Rs. 600/- per hours shall be deducted from the dues of the contractor. 389 (l)Please note that above penalty is exclusively other than the condition 67 of IAFW - 2249 and shall be treated as interim condition of the contract and shall be enforce above as and when delay in individual job is noticed and no claim whatsoever on this account shall be entertained by the Deptt. 390 (m) The decision of the Accepting Officer in this regard shall be final and binding. 391 (n)The contractor shall be responsible to maintain the DG set in serviceable condition for entire contract period. 392 Description all as per Sl Item No 324 here in before but for Capacity 40KVA DG Set- Location:-Pump House-1 No 393 Description all as per Sl Item No 324 here in before but for capacity125 KVA DG set Location:-Tech building :- 1 No 394 Description all as per Sl Item No 324 here in before but for capacity 250 KVA DG set Location:-Tech building :- 1 No 395 Dismantling/ taking down complete radiator assembly of 20 KVA to 40 KVA DG Set and transportation to authorised workshop for following repairs :-(a) Opening the radiator assembly with brazing/ welding for repair/ service.(b)Cleaning of all water tube with diluted solution of HCL and cleaning with water pressure and removing the sludge and dust from inside the tank by flushing out.(c)Determining the leak/ puncher in radiator tubes.(d)Repair of fins by soldering/ brazing.(e)Repair of bottom brass water tank by soldering/ brazing.(f) Repair of radiator hose assembly.(g)Fixing the complete radiator assembly to its original position and testing complete all as specified and directed by Engineer-in-Charge. 396 Dismantling/ taking down complete radiator assembly of 125 KVADG Set and transportation to authorised workshop for following repairs :-(a) Opening the radiator assembly with brazing/ welding for repair/ service.(b)Cleaning of all water tube with diluted solution of HCL and cleaning with water pressure and removing the sludge and dust from inside the tank by flushing out.(c)Determining the leak/ puncher in radiator tubes.(d)Repair of fins by soldering/ brazing.(e)Repair of bottom brass water tank by soldering/ brazing.(f) Repair of radiator hose assembly.(g)Fixing the complete radiator assembly to its original position and testing complete all as specified and directed by Engineer-in-Charge. 397 Taking down old unserviceable self motorof capacity 20 KVA to 40 KVAand carrying to authorised work shop for servicing includingreplacment of unserviceable spare parts Brush, holder, solonoid switch, armature bush, filed coil complete and refixing, testing complete all as specified and directed. 398 Taking down old unserviceable self motorof capacity 125 KVAand carrying to authorised work shop for servicing includingreplacment of unserviceable spare parts Brush, holder, solonoid switch, armature bush, filed coil complete and refixing, Testingcomplete all as specified and directed. 399 Removing and replacing the old unserviceable one with new AVR (Automatic Voltage Regulator) suitable for Kirloskar curve of capacity 20 to 40KVA having input voltage 2 phase + neutral sensing voltage 415 output voltage 95V DC, output current 4A DC voltage regulation +/- 1 % average volts, over excitation current tripping, fuse protection 4A, fast acting and frequency 50 Hzcomplete all as specified and directed. 400 Removing and replacing the old unserviceable AVR (Automatic Voltage Regulator) suitable for capacity 125KVA having input voltage 2 phase + neutral sensing voltage 415 output voltage 95V DC, output current 4A DC voltage regulation +/- 1 % average volts, over excitation current tripping, fuse protection 4A, fast acting and frequency 50 Hzcomplete all as specified and directed. 401 Taking down 12/ 24 volts self starter assembly from DG set and transporting to its authorised workshop for repair/ servicing by replacement of defective spare parts such as carbon brush, carbon ring, bearing, bush, defectine wiring, winding and soldering after repair including testing after repair/ service and re-installation in original position for satisfactory functioncomplete all as specified and directed. 402 Supply and fixingin replacement self starter 12 Volts of DG Sets complete all as specified and directed. 403 Supply and fixingin replacement battery cable assembly (-ve & +ve) complete all as specified and directed.Note :- Items like clamp, lugs, nut, bolts and copper cable of size 25 sqmm upto 1 mtr required for connection is deemed to be inclusive in unit rate quoted. 404 Supply and fixingin replacement maintenance free lead acid sealed battery (SMF) 12 volts 90 AH complete all as specified and as directed.Make : EXIDE. / Amaron/ Amar RajaNote :-Old battery shall be deposited in MES store yard. 405 Supply and fixingin replacement maintenance free lead acid sealed battery (SMF) 12 volts 180 AH complete all as specified and as directed.Make : EXIDE. / Amaron/ Amar RajaNote :-Old battery shall be deposited in MES store yard. 406 Material and labourOpening disconnecting LT Cable connections with care from Auto-Main Failure Panel and checking throughly with Fault Detector Instrument at Site and replacement of Minor Defective Parts as required at Site suitable for 20 KVA to 40 KVA DG Setcomplete all as specified and as directed. 407 Material and labourOpening disconnecting LT Cable connections with care from Auto-Main Failure Panel and checking throughly with Fault Detector Instrument at Site and replacement of Minor Defective Parts as required at Site suitable for 125 KVA DG Setcomplete all as specified and as directed. 408 Supply and fix in replacement of selectorswitch 16 A 2 pole 2 way complete all as specified and as directed. 409 Supply and fix in replacement of selectorswitch 16 A 3 pole 3 way complete all as specified and as directed. 410 Supply and fix in replacement of RPM meter assembly complete set including rubber gasket, wire as per sample complete all as specified and as directed. 411 Supply and fix in replacement of add-on auxilury contactorblock 2No-2NC complete all as specified and as directed. 412 Supply and fix in replacement of electronictimer delay of range12 sec to 120 sec operational in 240V AC supply complete all as specified and directed. Make:- Selectron or equivalent 413 Supply and fixingin replacement of Relay for control contactor AC control std. Coil Voltage - 24, 110, 240, 415V 50HZ (2 NO + 2 NC) complete all as specified and directed. Make L& T / BCH/ ABB 414 Supply and fixing in replacement indicator lamp RYB complete all as specified and as directed. 415 Supply and fix in replacement of push button for Start/Stop switch allas per sample complete all as specified and as directed. 416 Supply and fix in replacement of Relay for single phase preventor 6 wire suitable for all mode operation all as directed. 417 Supply and fix in replacement ofelectronic Oil pressure sensor complete with wiring, connectors, bottle thimble all as directed 418 Supply and fix in replacement of 12V/24V 11 pin PLA relay with base all as specified and as directed. 419 Supply and fix in replacement of radiator hose of any capacity complete all as specified and directed. 420 Supply and fix in replacement of oil drain hose set complete all as specified and as directed. 421 Supply and fix in replacement of fuelhose set nylon type of any capacity complete all as specified and directed. 422 Material and labourfor replacement of door hinges of Acoustic enclosureheavy duty metal type for Left/Right side complete all as specified and directed. 423 Supply and fixingMCCB 200A, 36 KA, 4 Pole, 415V including taking down unserviceable one, complete all as specified and as directed. Make - L &T/Havells/Indoasian 424 Supply andfix in replacement of water pump assembly of water cooling system of DG set any capacity complete all as specified and directed. 425 Supply and fix in replacement of electronic water temp gauge sensor double pin in byepass complete with wiring, connectors, bottle thimble complete all as specified and directed. 426 Supply and fix in replacement of radiatorfan belt suitable for any capacity DG set complete all as specified and as directed. 427 Material and labourfor distilled water in 5 ltr/ 2 ltr capacity sealed cane to be filled in batteries complete all as specified and directed. 428 Material and labourof electrolyte for battarycomplete all as specified and directed. 429 Supply and fixingMCCB 63A, 16 KA, 4 Pole, 415V including taking down unserviceable one, complete all as specified and as directed. Make - L &T/Havells/Indoasian 430 Supply and fixingin replacement stop solenoid assembly 12V/ 24V DC for micro pump (two coil) heavy duty electrical control make energise to stop of DG Setscomplete all as specified and directed.Make :- Kirloskar or existingbrand of defective components or any reputed suitable make as approved by GE 431 Disconnecting the existing battery of capacity 12V 90 to 180 AH from the DG set, taking it to battery workshop, draining out the complete unserviceable electrolyte acid from the battery, filling up with new Electrolyte acid to the required level, charging the battery, testing the battery for correct specific gravity, bringing back to the location, connecting to DG set, start the engine for satisfactory function all as directed by Engineer-in-charge. 432 Supply and fixing in replacement of brass terminal suitable for 12 Volts, 90/180 AHbattery complete all as specified & directed. 433 Supply and fixingBattery charging alternator assembly 12 Volts of DG Sets complete including taking down existing one complete all as specified & directed. 434 Material and labourRepairs to 12V battery charging alternator assembly by removing, dismantling, replacing the unserviceable burnt rotor and stator assembly completly including insulation sleeves and refixing to the engine and testing to the satisfaction of DC volts & Ampsby charging of battery complete all as specified & directed. 435 Supply and fix in replacement of lubrication oil filter element with O ring of Make MICO / Kirloskar / Mahle/ Cummins as required at site for 20KVA capacities of DG Sets complete all as specified and as directed. 436 Supply and fix in replacement of lubrication oil filter element with O ring of Make MICO / Kirloskar / Mahle/ Cummins as required at site for 40KVA capacities of DG Sets complete all as specified and as directed. 437 Supply and fix in replacement of lubrication oil filter element with O ring of Make MICO / Kirloskar / Mahle/ Cummins as required at site for 125KVA capacities of DG Sets complete all as specified and as directed. 438 Supply and fix in replacement of lubrication oil filter element with O ring of Make MICO / Kirloskar / Mahle/ Cummins as required at site for 250 KVA capacities of DG Sets complete all as specified and as directed. 439 Supply and fixingin repairs earth Fault relay complete all as specified and directed. 440 Supply and fix in replacement of turbo cooler rubber hose of any capacity complete all as specified and as directed. 441 Material and labourfor lubrication oil SAE 15 W - 40grade API CI 4 plustype in sealed container for DG set Top up and change the oil in the sump after completely flushing the old oil from the tank/sump and cleaning of the same complete all as specified and as directed. (Make :Castrol/Valvoline/Servo) 442 Supply and fix in replacement of oil seal assembly of any capacity as per sample complete all as specified and directed. 443 Material and labour for 3 ½ core 70 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laying in trenches/cable ducts, fixed to wall/pole complete including taking down unserviceable one all as specified and directed. Make : Havells/Polycab/ RPG Asian 444 Material and labour for 3 ½ core 95 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laying in trenches/cable ducts, fixed to wall/pole complete including taking down unserviceable one all as specified and directed. Make : Havells, Polycab, RPG Asian 445 Material and labour in repair formaking straight through joint with suitablejointing kit consisting of water proof adhesivesfor UG cable of size 3.50 core 70 Sqmm to 95 Sqmm, complete all as specified and directed. 446 Material and labour forBoring of holes under road, pavement hard standings by trenchless technology using ultra sound technique and necessary machine including HDPE pipes upto 100 mm dia suitable for 0.4 Mpa working pressure, complete all as specified and directed. 447 Disconnecting of burnt/ damaged cables from panels/ junction boxes etc, cutting out the burnt out ends, making new end joints by supply and fixing new aluminium lugs/ insulation tape etc and reconnecting using new nuts/ bolts/ washer etc and restoring three phase and neutral in the junction box, complete all as specified and as directed for thecable sizefrom 70 Sqmmto 95 Sqmm 3.5 core of underground LT armoured cables.Note :- Earth work required for extending the incoming/ outgoing cable in junction box/ panel board etc shall deemed to be included in the unit rate quoted. 448 Supply, installation, commissioning and testing of factory assembled, floor mounted, free standing type tested LT Feeder pillar panels, with canopy, as per electrical specifications for outdoor installation to be made of IP65 Polycarbonate modular enclosures. The enclosures made of polycarbonate, should be weather/vermin proof, anti -acid, anti-corrossive, UV resistance in accordance with IEC 61439-1, fire retardant and self extingushing in accordance with IEC 60695-2-11, UL subject 94 for flammability V-0, should pass glow wire test for 960 degree in accordance with 60695-2-11.Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262,IP65 in accordance with IEC-60529 and IEC- 60439-1, should have dielectric properties, RoHS compliant & Halogen free. The manufacturer of boards/panels shall submit a copy oftype test reports as per above mentioned norms either from UL/ERDA/CPRI/NABL labs in india.The panel should be modular and compartmentalized in construction with opaque and transparent doors, properly tightened to base with thremoplastic screws having sealing gaskets of extruded silicon rubber to withstand adverse weather effects. The depth of modular enclosure should be minimum 200mm for air circulation & to minimize temp rise. Panel should be fitted with one No.polycarbonate IP 65, 9 W LED translucent bulk head luminaire color temp not less than 6500K, PF >0.95 under canopy for easy maintenance. Panel should be fitted outside with one No. of 16 A 3 Pole IP65 industrial socket and 01 No. of 32A 5P IP 65 industrial socket. 3 Phase and neutral 400 Amp current carrying capacity of Aluminium bus bar insulated with colour coded heat shrinkable sleeves with SMC/DMC insulators,complete with the following switch gears and mounting the panel board on ground with PCC (1:3:6) type C-1 using 20 mm graded crushed stone aggregate for bedding upto a height of 45 CM above ground level, including dismanting and taking out U/s LT panel board and reconnecting existing LT UG Cable with new panel board all as directed :- 449 (a) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 250 Amp, 36 KA- 01 No (Incomer). (b) MCCB with thermal magnetic release 4 Pole, 415 V of capacity100 Amp,16 KA- 02 Nos.(c) MCCB with thermal magnetic release 4 Pole, 415 V of capacity63 Amp,16 KA- 02 Nos.(d) Multifunction Meter (V,I,PF) with suitable capacity of CTs- 01 No(e) Indicating lamp (R-Y-B) set LED type with backup MCB for 3 Phase Supply - 01 set.(f) Space for spare feeder - 01 No. Note :-(i) The Contractor shall submit the drawing for approval of GE before executing the work.(ii) Insulators, bus bar sleeves, lugs, gland etc including complete wiring with suitable size of copper wire are all inclusive in unit quoted rate. (iii) Make of Switch gear : Schneider/L&T/C&S.(iv) MCCB should be ICu =100% ICs.(v) Make of LT Panel/FPB shall be as mentioned in list of makes (PS). 450 Supply, installation, commissioning and testing of factory assembled, floor mounted, free standing type tested LT Feeder pillar panels, with canopy, as per electrical specifications for outdoor installation to be made of IP65 Polycarbonate modular enclosures. The enclosures made of polycarbonate, should be weather/vermin proof, anti -acid, anti-corrossive, UV resistance in accordance with IEC 61439-1, fire retardant and self extingushing in accordance with IEC 60695-2-11, UL subject 94 for flammability V-0, should pass glow wire test for 960 degree in accordance with 60695-2-11.Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262,IP65 in accordance with IEC-60529 and IEC- 60439-1, should have dielectric properties, RoHS compliant & Halogen free. The manufacturer of boards/panels shall submit a copy oftype test reports as per above mentioned norms either from UL/ERDA/CPRI/NABL labs in india.The panel should be modular and compartmentalized in construction with opaque and transparent doors, properly tightened to base with thremoplastic screws having sealing gaskets of extruded silicon rubber to withstand adverse weather effects. The depth of modular enclosure should be minimum 200mm for air circulation & to minimize temp rise. Panel should be fitted with one No.polycarbonate IP 65, 9 W LED translucent bulk head luminaire color temp not less than 6500K, PF >0.95 under canopy for easy maintenance. Panel should be fitted outside with one No. of 16 A 3 Pole IP65 industrial socket and 01 No. of 32A 5P IP 65 industrial socket. 3 Phase and neutral 400 Amp current carrying capacity of Aluminium bus bar insulated with colour coded heat shrinkable sleeves with SMC/DMC insulators,complete with the following switch gears and mounting the panel board on ground with PCC (1:3:6) type C-1 using 20 mm graded crushed stone aggregate for bedding upto a height of 45 CM above ground level, including dismanting and taking out U/s LT panel board and reconnecting existing LT UG Cable with new panel board all as directed :- 451 (a) MCCB with thermal magnetic release 4 Pole ,415 V of capacity 250 Amps ,36 KA- 01 No (Incomer).(b) MCCB with thermal magnetic release 4 Pole ,415 V of capacity 63 Amps ,10 KA- 04 Nos.(c ) Multifunction Meter (V,I,PF) with suitable capacity of CTs- 01 No.(d) Indicating lamp (R-Y-B) set LED type with backup MCB for 3 Phase Supply - 01 set.(e) Space for spare feeder -01 No.Note :-(i) The Contractor shall submit the drawing for approval of GE before executing the work.(ii) Insulators, bus bar sleeves, lugs, gland etc including complete wiring with suitable size of copper wire are all inclusive in unit quoted rate. (iii) Make of Switch gear : Schneider/L&T/C&S.(iv) MCCB should be ICu =100% ICs.(v) Make of LT Panel/FPB shall be as mentioned in list of makes (PS). 452 Material and labourreplacement of existing unserviceable door lock arrangement to DG set canopywith new door lock & key etc as per existing size & type complete all as specified & directed. 453 Supply and fix in replacement of electronic water temp gauge sensor single pin for engine block complete with wiring, connectors, bottle thimble complete all as specified and directed. 454 Supply and fixing in repairs door glass and beading for DG Set of any capacity complete all as specified and directed. 455 Supply and fixing in repairs 24V DC solenoid switch complete all as specified and directed. 456 Material and labourfor Urea which contain 32.5% urea and 67.5 % deionized water complete all as directed . 457 Supply and providing coolant concentrate in sealed container for top up complete all as specified and directed.Make : Valvoline/ Fleet guard/ Mahle 458 Supply and fix in replacement of electronic Fuel Level sensor complete with wiring, connectors, bottle thimble complete all as specified and directed. 459 Supply and fix in replacement of radiator mounting pad set of any size complete all as specified and directed. 460 Supply and Fix in replacement of temeprature guage of any capacity complete all as specified and as directed. 461 Supplyand Replacement of fuel filter element with O ring of Make MICO / Kirloskar / Mahle/ Ashok Leyland/ Cummins as required at site for 20 KVA capacities of DG Setsall as directed by Engineer-in-Charge. 462 Supplyand Replacement of fuel filter element with O ring of Make MICO / Kirloskar / Mahle/ Ashok Leyland/ Cummins as required at site for 40 KVA capacities of DG Setsall as directed by Engineer-in-Charge. 463 Supplyand Replacement of fuel filter element with O ring of Make MICO / Kirloskar / Mahle/ Ashok Leyland/ Cummins as required at site for 125 KVA capacities of DG Setsall as directed by Engineer-in-Charge. 464 Supplyand Replacement of fuel filter element with O ring of Make MICO / Kirloskar / Mahle/ Ashok Leyland/ Cummins as required at site for 250 KVA capacities of DG Setsall as directed by Engineer-in-Charge. 465 Supply and fixing in repairs mechanical type diesel float switch assembly complete all as specified and directed. 466 Supply and fixingin replacement Cooling Fansuitable for DG Set 125 KVA capacity, complete all as specified and as directed. 467 Supply and fixingin replacement Cooling Fansuitable for DG Set 20 to 40 KVA capacity, complete all as specified and as directed. 468 Supply and fix in replacement of flush type LED Digital multi functional meter withparameter (V,I,PF) suitable for DG set AMF panelcompleteof Model A class 1 complete all as specified & directed. 469 Supply and fixingin replacementcontactor 4 pole,with 1 NO + 1 NC aux contacts and coil voltage 240 V/415 volt suitable for AMF Panels of 125 KVADG Set complete all as specified and as directed. MAKE : L&T/BCH/Schneider 470 Supply and fixingin replacementcontactor 4 pole,with 1 NO + 1 NC aux contacts and coil voltage 240 V/415 volt suitable for AMF Panels of 40 KVADG Set complete all as specified and as directed. MAKE : L&T/BCH/Schneider 471 Supply and fixingin replacementcontactor 4 pole,with 1 NO + 1 NC aux contacts and coil voltage 240 V/415 volt suitable for AMF Panels of 20 KVADG Set complete all as specified and as directed. MAKE : L&T/BCH/Schneider 472 Disconnecting the electrical connection from AMF Panel, taking down DG set of cap 20 to 40KVA for major overhauling of engine and transportationto authorised workshop forreplacement of piston assembly complete-4 sets, exhaust valve, cyilinder liner, inlet and out let valves, sealing cap, copper washers,thermostat elements, spin of filter for lubrication oil, oil seal, valve tappet, gasket for cylinder head, bush for injector, gasket for exhuast manifold,joint for bearing housing, joint for delivery volute, turbo repair kit complete all as specified & directed. 473 Supply and fixing in repairs electronic type diesel float switch assembly complete all as specified and directed. 474 Supply and fix in replacment of valve door packing of any capacity complete all as specified and directed. 475 Supply and fix in replacement of Auto source transfer controller unitsuitable for DG set AMF panel of any capacity and as per existing Make complete all as specified and directed. 476 Supply and fixingin repairs change over switch 125 Amps capacity 4 pole 3 phase with enclosure complete all as specified and directed. Make-Legrand/ L&T / Indoasian 477 Supply and fixingin replacement microprocessor based AMF controller unit for AMF Panel flush mounting type suitable for DG Set 20 to 40 KVA capacity as per existing make complete all as specified and directed. 478 Supply and fixingin replacement microprocessor based AMF controller unit for AMF Panel flush mounting type suitable for DG Set 125 KVA capacity as per existing make complete all as specified and directed. 479 Supply and fix in replacement of Air filter elementinner and outer as required at site with O ring of Make MICO / Kirloskar / Mahle/ Cummins as required at site for 20 KVA capacities of DG Sets complete all as specified & directed. 480 Supply and fix in replacement of Air filter elementinner and outer as required at site with O ring of Make MICO / Kirloskar / Mahle/ Cummins as required at site for 40 KVA capacities of DG Sets complete all as specified & directed. 481 Supply and fix in replacement of Air filter elementinner and outer as required at site with O ring of Make MICO / Kirloskar / Mahle/ Cummins as required at site for 125 KVA capacities of DG Sets complete all as specified & directed. 482 Supply and fix in replacement of Air filter elementinner and outer as required at site with O ring of Make MICO / Kirloskar / Mahle/ Cummins as required at site for 250 KVA capacities of DG Sets complete all as specified & directed. 483 Supply and fixingin repairs change over switch 63 Amps capacity 4 pole 3 phase with enclosure complete all as specified and directed. Make-Legrand/ L&T / Indoasian 484 Supply and fixingin replacement ofwiring of AMF panel of capacity DG set including copper wire ,PVCwire holder and other connected items suitable for DG Set 20 to 40 KVA capacity as per existing make complete all as specified and directed. 485 Supply and fixingin replacement of Fly wheel ringincluding nuts and bolt suitable for DG Set 20 to 40 KVA capacity as per existing make complete all as specified and directed. 486 Supply and fixingin replacement of Fly wheel ringincluding nuts and bolt suitable for DG Set125 KVA capacity as per existing make complete all as specified and directed. 487 Surface dressing in hard / dense soilnot exceeding 15 cm deepand clearing all the grass weeds etc in the sub station yards after removing stone aggregate asideall as directed at site including setting / spreading back the aggregate complete all as specified and directed at site.Note:- (i)Additional stone aggregate required shall be measured and paid separately under relevant items of this schedule.(ii)The rate also deemed to be included for labour (iii) The sub station yards shall be kept cleanthrough out the contract period by removing the grass/weeds as many as times required depending on the growth of the grass. (iv)The rates shall be deemed to includesthe cost of removing two time the grass,weeds,debris,excess soil etc to a distance not less than 50 M and keeping the excavated surface clean and levelled all as directed. 488 Supply and laying of GI pipe light grade for cable protection of size 80 mm bore complete with fitting completeincluding taking down unserviceable one all as inspecified and directed. 489 Material and labour for 3 ½ core 185 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheather laying in trenches/cable ducts, fixed to wall/pole complete including taking down unserviceable one all as specified and directed. Make : Havells/ Polycab/ RPG Asian 490 Disconnecting of burnt/ damaged cables from panels/ junction boxes etc, cutting out the burnt out ends, making new end joints by supply and fixing new aluminium lugs/ insulation tape etc and reconnecting using new nuts/ bolts/ washer etc and restoring three phase and neutral in the junction box, complete all as specified and as directed for thecable sizefrom 150 Sqmmto 185 Sqmm 3.5 core of underground LT armoured cables.Note :- Earth work required for extending the incoming/ outgoing cable in junction box/ panel board etc shall deemed to be included in the unit rate quoted. 491 Supply, installation,commissioning and testing of factory assembled ,floor mounted ,free standing type tested LT Feeder pillar panels,with canopy ,as per electrical specifications for outdoor installation to be made of IP65 Polycarbonate modular enclosures. The enclosures made of polycrabonate,should be weather vermin proof, anti -acid,anti-corrossive,UV resistance in accordance with IEC 61439-1,fire retardant and self extingushing in accordance with IEC 60695-2-11 ,UL subject 94 for flammability V-0, should pass glow wire test for 960 degree in accordance with 60695-2-11.Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262,IP65 in accordance with IEC-60529 and IEC- 60439-1, should have dielectric properties ,RoHS compliants & Halogen free. The manufacturer of boards/panels shall submit a copy oftype test reports as per above mentioned norms either from UL/ERDA/CPRI/NABL labs in india.The panel should be modular and compartmentalized in construction with opaque and transparent doors, properly tight to base with thermoplastic screw having sealing gaskets of extruded silicon rubber to withstand adverse weather effects. The depth of modular enclosuser should be above 200mm for air circulation & to minimize temp rise. Panel shallbe fitted with one No. ofpolycarbonate IP 65 9 W LED transperent bulk head luminaire 6500K,PF >0.95 under canopy for easy maintenance . Panel should be fitted outside with one No. of 16 Amp 3 Pole IP65 industrial socket and 01 No. of 32 Amp 5P IP 65 industrial socket. 3 Phase and neutral 300 Amp current carrying capacity of aluminium bus bar insulated with colour coded heat shrinkable sleeves with SMC/DMC insulators,complete with the following switch gears and mounting the panel board on ground with PCC (1:3:6) type C-1 using 20mm graded stone aggregate for bedding upto a height of 45 CM above ground level ,including dismanting and taking out old U/s LT panel board and reconnecting existing LT UG Cable with new panel board, complete all as specified and directed :- 492 (a) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 200 Amp, 36 KA- 01 No (Incomer).(b) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 100 Amp, 10 KA- 01 No.(c) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 63 Amp, 25 KA- 01 No.(d) Multifunction Meter (V,I,PF) with suitable capacity of CTs- 01 No.(e) Indicating lamp (R-Y-B) set LED type with backup MCB for 3 Phase Supply - 01 set.(f) Space for spare feeder - 01 No. Note :-(i) The Contractor shall submit the drawing for approval of GE before executing the work.(ii) Insulators, bus bar sleeves, lugs, gland etc including complete wiring with suitable size of copper wire are all inclusive in unit quoted rate. (iii) Make of Switch gear : Schneider/L&T/C&S.(iv) MCCB should be ICu =100% ICs.(v) Make of LT Panel/FPB shall be as mentioned in list of makes (PS). 493 Supply, installation,commissioning and testing of factory assembled ,floor mounted ,free standing type tested LT Feeder pillar panels,with canopy ,as per electrical specifications for outdoor installation to be made of IP65 Polycarbonate modular enclosures. The enclosures made of polycrabonate,should be weather vermin proof, anti -acid,anti-corrossive,UV resistance in accordance with IEC 61439-1,fire retardant and self extingushing in accordance with IEC 60695-2-11 ,UL subject 94 for flammability V-0, should pass glow wire test for 960 degree in accordance with 60695-2-11.Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262,IP65 in accordance with IEC-60529 and IEC- 60439-1, should have dielectric properties ,RoHS compliants & Halogen free. The manufacturer of boards/panels shall submit a copy oftype test reports as per above mentioned norms either from UL/ERDA/CPRI/NABL labs in india.The panel should be modular and compartmentalized in construction with opaque and transparent doors, properly tight to base with thermoplastic screw having sealing gaskets of extruded silicon rubber to withstand adverse weather effects. The depth of modular enclosuser should be above 200mm for air circulation & to minimize temp rise. Panel shallbe fitted with one No. ofpolycarbonate IP 65 9 W LED transperent bulk head luminaire 6500K,PF >0.95 under canopy for easy maintenance . Panel should be fitted outside with one No. of 16 Amp 3 Pole IP65 industrial socket and 01 No. of 32 Amp 5P IP 65 industrial socket. 3 Phase and neutral 600 Amp current carrying capacity of aluminium bus bar insulated with colour coded heat shrinkable sleeves with SMC/DMC insulators,complete with the following switch gears and mounting the panel board on ground with PCC (1:3:6) type C-1 using 20mm graded stone aggregate for bedding upto a height of 45 CM above ground level ,including dismanting and taking out old U/s LT panel board and reconnecting existing LT UG Cable with new panel board, complete all as specified and directed :- 494 (a) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 400 Amps, 36 KA- 01 No (Incomer).(b) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 200 Amps, 25 KA- 03 Nos.(c) MCCB with thermal magnetic release 4 Pole ,415 V of capacity 100 Amps, 10 KA- 02 Nos.(d) Multifunction Meter (V,I,PF) with suitable capacity of CTs- 01 No.(e) Indicating lamp (R-Y-B) set LED type with backup MCB for 3 Phase Supply - 01 set.(f) Space for spare feeder - 01 No. Note :-(i) The Contractor shall submit the drawing for approval of GE before executing the work.(ii) Insulators, bus bar sleeves, lugs, gland etc including complete wiring with suitable size of copper wire are all inclusive in unit quoted rate. (iii) Make of Switch gear : Schneider/L&T/C&S.(iv) MCCB should be ICu =100% ICs.(v) Make of LT Panel/FPB shall be as mentioned in list of makes (PS). 495 Material andlabour forTesting of earth resistancevalue from earthing pit test terminal pointand write in/ on existingidentification board complete all as specified and as directed.Around upto 1.50 Metre Area of existing Earth Pit with tightening of Strip comprising of the following process :- 496 The following items are deemed to be inclusive of quoted rate :-(i)The above job shall be carried out by a trained technician having ITI in electrical and well known regarding earthing test. Documantary proof of the education of tradesman shall be produced by the contractor to the Engr-in-charge, before commencement of work. 497 (ii)The aforsesaid test shall be carried out in presence of user and MES represnetative. 498 (iii) Two Party (consisting 2 x 1 No. Technician with 1 No. Helper) shallreport every Morningat 9 AM to JE E/M for Daily earth testing. 499 (iv) Earth Resistance Tester will be provided by the Contractor. (Tester should be caliberated from Authorised Company/ Lab). 500 (v) Contractor shall be responsible for pouring of water in the Earth Pits Weekly at their own arrangement with Water Tanker, etc. (water will be provided by the contractor at his own arrangement and nothing extra will be admissible). 501 (vi) Contractor shall be responsible for marking of Earth check date and due date on existing Plate with synthetic enamel paint as specified by Engineer-in-Charge. 502 (vii)Contractor shall be responsible for cleaning of bushes and grass all around upto 1.50 Metre Area of existing Earth Pit with tightening of Strip. 503 Supply only charcoal dust/Breeze in trenches to improve the ER value of existing earth pits, complete all as specified and as directed. 504 Supply only common salt commercial in trenches to improve the ER value of existing earth pits, complete all as specified and as directed. 505 Material and labour for magnesium sulphate (MgSO4) for improvement of earthing resistivity, complete all as specified and directed. 506 Material and labour for Powder Earthing Backfill Compound, Grade Standard for improvement of earthing resistivity and to increase the absorption of moisture around the earthing electrode, complete all as specified and directed. 507 Supply and fixing in repair 20 mm bore galvanised steel water tubing medium grade with all fitting fixed to wall and ceiling or laid in floors etc, complete all as specified and directed. 508 Supply and fixing in repair 40 mm bore galvanised steel water tubing medium grade with all fitting laid in trenches/or laid in floor etc, complete all as specified and directed . 509 Supply and Fix in repairs Bib Tap of 15 mm dia standard of PTMT any colour high pressure screwed for iron pipe(Minimum weight 90 gms ), complete all as specifed and directed. 510 Taking downn unsv funnel of any type and size Supply and fixing in repair GI funnels for earthing, complete all as specified and as directed. 511 Taking down existing GI earthstrip 25x3mm thick as earthing lead with its accessories and re fixing to wall/roofs etc. drawn in conduit/GI pipe etccomplete all as specified and as directed.Note:- Unit rate is deemed to be included for old broken insulators/ clamps to replace with new insulators of existing size as per site and making good disturbed surfaces of floors/walls/ceiling etc complete all as directed. 512 Supply and fixing in replacement of aluminium strip 25x3mm fixed with epoxy based insulator for down conductor air terminal network including drilling two Nos holes at each joint, one set of lead washers between strips, two sets GI nut andbolt, gutties, screws etc,.on wall /roof including necessary fixing arrangement up to height 20mtrcomplete all as specified and directed.Note:- Unit rate is deemed to be included for old broken insulators/ clamps to replace with new insulators of existing size as per site and making good disturbed surfaces of floors/walls/ceiling etc complete all as directed.(ii) All safety measures shall be the responsibility of the contractor 513 Taking down of serviceable aluminium strip 25x3mm and refixing the same with epoxy based insulator/post insulator/spacerfor down/ lightening conductor air terminal network including drilling two Nos holes at each joint, one set of lead washers between strips, two sets GI nut andbolt, gutties, screws etc.on wall /roof including necessary fixing arrangement up to height 20mtrcomplete all as specified and directed.Note:- Unit rate is deemed to be included for old broken insulators/ clamps to replace with new insulators of existing size as per site and making good disturbed surfaces of floors/walls/ceiling etc complete all as directed.(ii) All safety measures shall be the responsibility of the contractor 514 Supply and fixing in repair test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 Nos. 8mm dia 25mm long hexagonal. head screw, complete all as specified and directed. 515 Material and labourin repairs Galvanised iron Earth strip of size 32 x 6 mm fixed on proper post insulator at the instrument end complete all as per specified and as directed. 516 Repairing and maintenance of old existing earth pit by taking out carefully earth plate, watering pipe, earth lead protection pipe and re-buried the same after removing sludge from the plate & pipes including re-connection/brazing the plate and strip, wherever is required at site (Earth pit not less than 2.25 mtr deep below normal ground level ) with top edge of earth plate not less than 1.5 metres below normal ground level,complete all as specified and directed includingPCC 1:3:6 type C1 using 20mm graded stone aggregate for pit with cover of RCC 1:2:4 type B1 using 20mm graded aggregate, reinforced with welded steel wire fabric not less than 4 kg per Sqmtr with handle and angle iron frame,watering arrangment with 20 mm bore GI medium grade pipe ISI marked, GI funnel with GI mesh,filling with mixture of common salt and charcoal,necessary excavation, refilling, removing away soil and earth work in any type of soil including test point, testing and commissioning, complete all as specifed and as directed.Note : GI Funnel, brazing, mixture of salt/char coal/MgSO4 shall be measured and paid separately under releavant items. 517 S&F in repair copper strip 20 x 3mm thick as earthing lead fixed to wall/roofs etc including taking down existing old unserviceable copper strip etc, complete all as specified anddirected. Note : - All Joints should be joined by Exothermic Welding or Brazing. 518 Material and labour for Brazing of copper/Aluminium for continuity, complete all as specified and as directed. 519 Supply and fix in repair of wall mounted fans PVC body 230 Voltssingle phase oscillating 400mm sweep suitable for wall mounting all as specified and directed. Make : Havells/Bajaj/ Orient.Note:-(a)Old Unserviceable ceiling fan shall be deposited to MES store yard. 520 Material and labour for fixing earth indicators made out of 3 mm thick MS sheet of size 200mm x 300mm duly fixed in MS angle iron 25mmx25mmx3mm of 450 mm long to be fixed to ground by means withnecessarycement concrete andpainting with two coats of synthetic enamel paint over a coat of red oxide primer, writing earth reading and connected items like painting of panel etc, and necessary excavation and earth work including taking down old, complete all as specified and as directed. 521 Supply, installation, testing & commissioning of maintenance free chemicalearthing system comprising of 17mm dia copper bondedrod 3 mtr long horizontally pre welded T-terminal rod with provision for connection size of 50 x 150mm long, 6mm thickness with equal space either side, with 12mm dia hole of 02 numbers each on either side of the terminal clamp with 250 microns (average) coating thickness, tested and certified by CPRI India alongwith 50 Kg earth energizer compound and 10 litres earth resistance reducingliquid. The earthing energizer compound and resistance reducing earthing liquid shall be tested as per IEC-62561-7 read with ASTM G57-06, CI 3.4 A by any NABL accredited lab. The above mentioned rod shall be installed in 4-6 inch bore, 12 feet depth with a distance of minimum 3 meters between each installation including taking down existing one, complete all as specified and directed..Make : Model HTSP 317 of safeTrode or equivalent in Snaga/ Cubes 6 Global 522 The quoted rate shall also deemed to be included the following :- (i)Prior toinstallation of maintenance free chemicalearthing, soil resistivity test to be carried out at the location where earthingwork to be donein presence of Engr-in- Charge/JE (E/M),user and the report has tosubmitto Garrison Engineer with recommendation of manufacturer, if required additional interconnection ofearthing (not more than 08 number of earthing) to achive earth result less then 1 Ohms. The arrangement done for soil resistivity testingandsubmission of report with recommendationdeemed to be included in the quoted rate. 523 (ii) The description/ size/ qty of items mentioned in above are for indicating only however qty/ size may vary at site condition to maintain the earth resistance 1 ohm. The contractor shall quote rate by considering all factors. 524 (iii) Rateofearth energizer compound of 25 Kg of 02 bags and earthresistance reducingliquid 10 litre per cane for each pit deemed to be included in the quoted rate. 525 (iv)Resistivity of earth energizer compound and resistance reducing earthing liquid shall be certified by any NABL accredited lab carried out as per IEC-62561-7 read with ASTMG57-06, CI-3.4A and the certificate of same shall be submitted by the contractor along with the sample approval 526 (v) Earth enhancing material should not leach into the adjacent soil or underground water channels and its PH value should be in neutral range complete all as specified and as directed. It should solidify when mixed with water and set like concrete. 527 (vi) Copper strip of size 20 x 3 mm shallbe fixed on proper post insulator at the instrument end (copper strip upto 7.5 RM shall be considered in unit quoted rate and extra will be measured and paid separately). 528 (vii)Testing of earth shall be carriedout in presence ofdepartmental and user representativeand report shall be submitted to Garrison Engineer duly signed by all concerned. 529 (viii)Earth resistance tester will be provided by the contractor.Tester should be calibrated from authorised company/ lab. 530 (ix)Earthing shall be tested after completion of work by the contractor in presence of Engr-in-charge, user and proper record shall be maintained duly signed by all concerned.After testing if the desired earth resistance of less than 1 Ohm is not obtained, the earthing will be redone at no extra cost to Govt. till desired result is obtained. 531 (x) The contractor shall give a written guarantee of minimum three years for maintaining the earth resistance less than 1 Ohm after certified date of completion. 532 (xi) No further maintenance or periodic watering or recharge shall be required in earthing during its guarantee period of over 03 years in all type of soil including soft/ disintegrated or hard rock. 533 (xii) During the guarantee period, if earth resistance is not maintained less than 1 ohm the contractor has to redo or rectify at no extra cost to Govt till desired result is maintained. 534 (xiii) A security deposit of value equal to 2.5 % of the rate quoted for chemical earthing for each earthing shall be retained from payment due to the contractor from final bill for the guarantee period. 535 (xiv) The electrode shallcarry manufacturers name . 536 (xv) The connection clamp shall be permanentlly welded to the copper boundedrodto avoid any kind of connectivity loss,.The pre-welded copper bounded rod shall not need any additional clamp for termination. 537 (xvi) The acceptable earth resistance at earth busbar/ test point shall not be more than 0.1 ohm. 538 (xvii)Earth work such as auguring andmaking good the surrounding area shall carried out in any type of soil. 539 (xviii)The contractor shall submit CPRI India certified document for copper bounded rod to ensure genuineness of material. 540 (xix) Sign boardof mild steel sheet 2 mm thick duly painted with two coats of synthetic enamel paint over a coat of red oxideZinc chrome primer showing result of earthing shall be fixed near the earth pit after completion as directed by engr -in- charge. 541 Material and labour for Earth pit cover madeof heavy duty poly plastic of high grade polypropylene tested and certified by any NABL accredited lab for load bearing capacity not less than 7.2 tonnes with top dia not less than 250mm, bottom dia not less than 330 mm and height not less than 260 mm for each electrode pit complete including taking down old one complete all as specified and directed.Make : Model SEPC 250 of SAFE TRODE or equivalent in Snaga/ Cubes 6 Global 542 Supply, installation, commissioning and testing of factory assembled, floor mounted, free standing type tested LT Feeder pillar panel, with canopy, as per electrical specifications for outdoor installation to be made of IP65 Polycarbonate modular enclosures. The enclosures made of polycarbonate, should be weather/vermin proof, anti -acid, anti-corrossive, UV resistance in accordance with IEC 61439-1, fire retardant and self extingushing in accordance with IEC 60695-2-11, UL subject 94 for flammability V-0, should pass glow wire test for 960 degree in accordance with 60695-2-11.Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262,IP65 in accordance with IEC-60529 and IEC- 60439-1, should have dielectric properties, RoHS compliants & Halogen free. The manufacturer of boards/panels shall submit a copy oftype test reports as per above mentioned norms either from UL/ERDA/CPRI/NABL labs in india.The panel should be modular and compartmentalized in construction with opaque and transparent doors, properly tightened to base with thermoplastic screws having sealing gaskets of extruded silicon rubber to withstand adverse weather effects. The depth of modular enclosure should be minimum 200mm for air circulation & to minimize temp rise. Panel should be fitted with one No.polycarbonate IP 65, 9 W LED translucent bulk head luminaire color lamp not less than 6500K, PF >0.95 under canopy for easy maintenance. Panel shall be fitted outside with one No of 16 Amp 3 Pole IP65 industrial socket and 01 No. of 32Amp 5P IP 65 industrial socket. 3 Phase and neutral 630 Amp current carrying capacity of aluminium bus bar insulated with colour coded heat shrinkable sleeves with SMC/DMC insulators,complete with the following switch gears and mounting the panel board on ground with PCC (1:3:6) type C-1 using 20mm graded aggregate forbedding upto a height of 45 CM above ground level, including dismanting and taking out old U/s LT panel board and reconnecting existing LT UG Cable with new panel board amplete all as specified and all as directed and comprising of the following:- 543 (a) ON load change over switch 4 Pole, 415 V of capacity 400 Amp, 36 KA - 01 No . (b) MCCB with thermal magnetic release 4 Pole, 415 V of capacity400 Amp,36 KA- 02 Nos.(c) Multifunction Meter (V,I,PF) with suitable capacity of CTs- 01 No(d) Indicating lamp (R-Y-B) set LED type with backup MCB for 3 Phase Supply - 01 set. (e) Space for spare feeder - 01 No. Note :-(i) The Contractor shall submit the drawing for approval of GE before executing the work.(ii) Insulators, bus bar sleeves, lugs, gland etc including complete wiring with suitable size of copper wire are all inclusive in unit quoted rate. (iii) Make of Switch gear : Schneider/L&T/C&S.(vi) MCCB should be ICu =100% ICs.(v) Make of LT Panel/FPB shall be as mentioned in list of makes (PS). 544 Supply, installation, commissioning and testing of factory assembled, floor mounted, free standing type tested LT Feeder pillar panels, with canopy, as per electrical specifications for outdoor installation to be made of IP65 Polycarbonate modular enclosures. The enclosures made of polycarbonate, should be weather/vermin proof, anti -acid, anti-corrossive, UV resistance in accordance with IEC 61439-1, fire retardant and self extingushing in accordance with IEC 60695-2-11, UL subject 94 for flammability V-0, should pass glow wire test for 960 degree in accordance with 60695-2-11.Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262,IP65 in accordance with IEC-60529 and IEC- 60439-1, should have dielectric properties, RoHS compliant & Halogen free. The manufacturer of boards/panels shall submit a copy oftype test reports as per above mentioned norms either from UL/ERDA/CPRI/NABL labs in india.The panel should be modular and compartmentalized in construction with opaque and transparent doors, properly tightened to base with thremoplastic screws having sealing gaskets of extruded silicon rubber to withstand adverse weather effects. The depth of modular enclosure should be minimum 200mm for air circulation & to minimize temp rise. Panel should be fitted with one No.polycarbonate IP 65, 9 W LED translucent bulk head luminaire color temp not less than 6500K, PF >0.95 under canopy for easy maintenance. Panel should be fitted outside with one No. of 16 A 3 Pole IP65 industrial socket and 01 No. of 32A 5P IP 65 industrial socket. 3 Phase and neutral 600 Amp current carrying capacity of Aluminium bus bar insulated with colour coded heat shrinkable sleeves with SMC/DMC insulators,complete with the following switch gears and mounting the panel board on ground with PCC (1:3:6) type C-1 using 20 mm graded crushed stone aggregate for bedding upto a height of 45 CM above ground level, including dismanting and taking out U/s LT panel board and reconnecting existing LT UG Cable with new panel board all as directed :- 545 (a) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 400 Amps36 KA- 01 No.(Incomer).(b) Change over switch 400A, 4P front operated - 01 No.(c) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 160 Amps25 KA- 02 Nos (O/G).(d) MCCB with thermal magnetic release 4 Pole, 415 V of capacity125 Amps 25 KA- 02 Nos (O/G).(e) MCCB with thermal magnetic release 4 Pole, 415 V of capacity100 Amps 10 KA- 01 No (O/G)(f) MCCB with thermal magnetic release 4 Pole, 415 V of capacity63 Amps 10 KA- 01 No (O/G)(g) MCB SPNof 240 V of capacity 40 Amps 10 KA- 01 No.(h) Multifunction Meter (V,I,PF) with suitable capacity of CTs- 01 No.(j) Indicating lamp (R-Y-B) set LED type with backup MCB for 3 Phase Supply - 01 set.(k) Space for spare feeder - 01 No. Note :-(i) The Contractor shall submit the drawing for approval of GE before executing the work.(ii) Insulators, bus bar sleeves, lugs, gland etc including complete wiring with suitable size of copper wire are all inclusive in unit quoted rate. (iii) Make of Switch gear : Schneider/L&T/C&S.(iv) MCCB should be ICu =100% ICs.(v) Make of LT Panel/FPB shall be as mentioned in list of makes (PS). 546 Note :- An amount of Rs 2,49,138.00 on account of credit schedule for schedule A part II shall be deducted from the total amount of BOQ to arrive at the contract sum.