Tender For Repair/Replacement Of Unserviciable Flameproof Light, Industrial Lights And Connected Items Works At Otm Area At Af Stn Phalodi, phalodi-Rajasthan

Military Engineer Services has published Tender For Repair/Replacement Of Unserviciable Flameproof Light, Industrial Lights And Connected Items Works At Otm Area At Af Stn Phalodi. Submission Date for this Tender is 19-09-2025. LED Light Tenders in phalodi Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

50933873
Tender For Repair/Replacement Of Unserviciable Flameproof Light, Industrial Lights And Connected Items Works At Otm Area At Af Stn Phalodi
Tender
Indian
Rajasthan
Phalodi
19-09-2025

Tender Details

Tender For Repair/Replacement Of Unserviciable Flameproof Light, Industrial Lights And Connected Items Works At Otm Area At Af Stn Phalodi; 1 S&F in replacement ofLED flameproof light1x16/20 Watt, 4 long with die cast aluminium housing with heat resistance toughten glasswith LED tube lightfixture driver, holder, connector etc prewiredincluding connecting up with 3 corecopper cable in steel flexible pipe complete all as specified and directed. 2 M&L for point wiring with three layer PVC Insulated 1.5 Sqmm multi-strand copper conductor FRLSH cable 1100 Volts grade drawn into in stove enamelled steel conduit conduits including all fitting and fixing accessories( bend, tee, junction box etc)on surface/concealed conduit of size 20mm heavy duty ISI marked , fire proof steel terminal sunken boxes for One light/ fan Point controlled by one switch including 1.5 Sqmm copper conductor cable FRLSH 1100 Volts connected to common earth dolly complete all as specified and as directed . 3 M&L for point wiring with three layer PVC Insulated 2.5 Sqmm multi-strand copper conductor FRLSH cable 1100 Volts grade drawn into in stove enamelled steel conduit conduits including all fitting and fixing accessories( bend, tee, junction box etc)on surface/concealed conduit of size 20mm heavy duty ISI marked , fire proof steel terminal sunken boxes for One light/ fan Point controlled by one switch including 2.5 Sqmm copper conductor cable FRLSH 1100 Volts connected to common earth dolly complete all as specified and as directed . 4 S&F in replacement offlame proof switch rotary type with termination box in LM 6,16 Amp , Single pole ON-OFF, 240 Volt Complete all as specified and as directed 5 S&F in replacement of flame proof switch rotary type with termination box in LM 6,25 Amp , doublepole ON-OFF, 240 Volt Complete all as specified and as directed. 6 S&F in replacement of flame proof switch rotary type with termination box in LM 6,16 Amp , doublepole ON-OFF, 240 Volt Complete all as specified and as directed. 7 S&F in replacement of flame proof switch socket & plug combined in LM6 cable termination box in LM6, 25 A 250V, 2P+eartht Complete all as specified and as directed. 8 M&L forSub main wiring with 2 runs of 1.5 sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLSH 1100 volts grade cable drawn through recessed steel conduit medium duty with conduit accessories fixed on wall/roof and one run of 1.5 Sqmmsingle core PVC insulated but unsheathed multistranded copper conductor FRLSH 1100 volts grade cableas earth conductor and making good disturbed surfaces including taking down old submain wiring complete all as specified and directed. Note : (i) Two runs of 1.5 Sqmm cable, one run of 1.5 Sqmm earth conductor and one run of steel conduit of shall be measured and paid as one unit length. 9 M&L forSub main wiring with 2 runs of 2.5 sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLSH 1100 volts grade cable drawn through recessed steel conduit medium duty with conduit accessories fixed on wall/roof and one run of 2.5 Sqmmsingle core PVC insulated but unsheathed multistranded copper conductor FRLSH 1100 volts grade cableas earth conductor and making good disturbed surfaces including taking down old submain wiring complete all as specified and directed. Note : (i) Two runs of 2.5 Sqmm cable, one run of 2.5 Sqmm earth conductor and one run of steel conduit of shall be measured and paid as one unit length. 10 M&L forSub main wiring with 2 runs of 4.0 sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLSH 1100 volts grade cable drawn through recessed steel conduit medium duty with conduit accessories fixed on wall/roof and one run of 4.0 Sqmmsingle core PVC insulated but unsheathed multistranded copper conductor FRLSH 1100 volts grade cableas earth conductor and making good disturbed surfaces including taking down old submain wiring complete all as specified and directed. Note : (i) Two runs of 4.0 Sqmm cable, one run of 4.0 Sqmm earth conductor and one run of steel conduit of shall be measured and paid as one unit length. 11 M&L forSub main wiring with 2 runs of 6.0 sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLSH 1100 volts grade cable drawn through recessed steel conduit medium duty with conduit accessories fixed on wall/roof and one run of 6.0 Sqmmsingle core PVC insulated but unsheathed multistranded copper conductor FRLSH 1100 volts grade cableas earth conductor and making good disturbed surfaces including taking down old submain wiring complete all as specified and directed. Note : (i) Two runs of 6.0 Sqmm cable, one run of 6.0 Sqmm earth conductor and one run of steel conduit of shall be measured and paid as one unit length. 12 M&L forSub main wiring of any height in hager recess with 4 runs of 4.0 sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLSH 1100 volts grade cable drawn through steel conduit medium duty with conduit accessories fixed on wall/roof and one run of 4.0 Sqmmsingle core PVC insulated but unsheathed multistranded copper conductor FRLSH 1100 volts grade cableas earth conductor and making good disturbed surfaces including taking down old submain wiring complete all as specified and directed. Note : (i) Four runs of 4.0 Sqmm cable, one run of 4.0 Sqmm earth conductor and one run of steel conduit of shall be measured and paid as one unit length. 13 M&L forSub main wiring of any height in hager recess with 4 runs of 6.0 sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLSH 1100 volts grade cable drawn through steel conduit medium duty with conduit accessories fixed on wall/roof and one run of 6.0 Sqmmsingle core PVC insulated but unsheathed multistranded copper conductor FRLSH 1100 volts grade cableas earth conductor and making good disturbed surfaces including taking down old submain wiring complete all as specified and directed. Note : (i) Four runs of 6.0 Sqmm cable, one run of 6.0 Sqmm earth conductor and one run of steel conduit of shall be measured and paid as one unit length. 14 M&L forSub main wiring of any height in hager recess with 4 runs of 10.0 sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLSH 1100 volts grade cable drawn through steel conduit medium duty with conduit accessories fixed on wall/roof and one run of 10.0 Sqmmsingle core PVC insulated but unsheathed multistranded copper conductor FRLSH 1100 volts grade cableas earth conductor and making good disturbed surfaces including taking down old submain wiring complete all as specified and directed. Note : (i) Four runs of 10.0 Sqmm cable, one run of 10.0 Sqmm earth conductor and one run of steel conduit of shall be measured and paid as one unit length. 15 Supply and fixing in replacement PVC insulated and sheathed weather proof two core 2.5 sqmm single stranded aluminium conductor service cable for connection complete all as specified and directed. 16 Supply and fixing in replacement PVC insulated and sheathed weather proof two core 4.0 sqmm single stranded aluminium conductor service cable for connection complete all as specified and directed. 17 Supply and fixing in replacement PVC insulated and sheathed weather proof two core 6.0 sqmm single stranded aluminium conductor service cable for connection complete all as specified and directed. 18 Supply and fixing in replacement PVC insulated and sheathed weather proof two core 10.0 sqmm single stranded aluminium conductor service cable for connection complete all as specified and directed. 19 Supply and fixing in replacement of unserviceable garden lights with LED landscape luminaires 10 Watts pressure die cast powder coated housing with PC diffuser,Efficient high output COB for garden, Pathway lightning, IP 66 protection complete all as specified and directed. 20 Supply and fixing in replacement of unserviceable 35W LED Post top made in cast aluminium spigot housing with decorative opal acrylic diffuser and IP65 protection complete with all accessories suitable for connection of copper wires complete all as specified and directed. 21 Supply and fixing in replacement of unserviceable highmast flood light luminaire of HPSV/MH,with LED flood light fitting consist of PDC aluminium housing in powder coated die-casting power coated in gray finish,high power LED with IP 66protection, fins are provided on housing ,heat resistant tempered glass for protectionwith 5 KV surge protection of 150 W LED 5700K complete all as specified and directed. 22 Supply and fixing in replacement of unserviceable highmast flood light luminaire of HPSV/MH,with LED flood light fitting consist of PDC aluminium housing in powder coated die-casting power coated in gray finish,high power LED with IP 66protection, fins are provided on housing ,heat resistant tempered glass for protectionwith 5 KV surge protection of 120 W LED 5700K complete all as specified and directed. 23 Supply and fixing in replacement energy efficient LED street light fitting of 25 Watt ,epoxy powder coated pressure die cast aluminium housing to act as heat sink for efficient dissipation of heat and toughened glass with IP 66 degree of protection, system luminous efficency morethan 100 lumens / watt individual LEDs should have lenses for better throw across and along road, PF>0.9 with voltage range 140 to 270 Volt, fitting should be provided wih inbuilt 10 KV minimum surge protection, short circuit and over voltage protection facility for Driver and fiiting including bracket of suitable size upto 1.5 mtr long & MS Flat clamp of suitable size complete all as specified and directed. 24 Supply and fixing energy efficient LED street light fitting of 45 Watt ,epoxy powder coated pressure die cast aluminium housing to act as heat sink for efficient dissipation of heat and toughened glass with IP 66 degree of protection, system luminous efficency morethan 100 lumens / watt individual LEDs should have lenses for better throw across and along road, PF>0.9 with voltage range 140 to 270 Volt, fitting should be provided wih inbuilt 10 KV minimum surge protection, short circuit and over voltage protection facility for Driver and fiiting including bracket of suitable size upto 1.5 mtr long & MS Flat clamp of suitable size complete all as specified and directed. 25 Supply and fixing energy efficient LED street light fitting of 60 Watt ,epoxy powder coated pressure die cast aluminium housing to act as heat sink for efficient dissipation of heat and toughened glass with IP 66 degree of protection, system luminous efficency morethan 100 lumens / watt individual LEDs should have lenses for better throw across and along road, PF>0.9 with voltage range 140 to 270 Volt, fitting should be provided wih inbuilt 10 KV minimum surge protection, short circuit and over voltage protection facility for Driver and fiiting including bracket of suitable size upto 1.5 mtr long & MS Flat clamp of suitable size complete all as specified and directed. 26 Supply and fixing of 45 watt Inverter LED Street Light with IR Sensor for automatic On-Off of street light and shall have inbuilt Li-on battery for 90mins power backup in case ofpower failure. Housing of fixture shall be presurre die cast and system efficacy >100LPW, CRI >70, CCT 5700K, PF>0.9, THD<15% complete all as specified and directed. 27 Supply and fixing of 60 watt Inverter LED Street Light with IR Sensor for automatic On-Off of street light and shall have inbuilt Li-on battery for 90mins power backup in case ofpower failure. Housing of fixture shall be presurre die cast and system efficacy >100LPW, CRI >70, CCT 5700K, PF>0.9, THD<15% complete all as specified and directed. 28 Supply and fixing in renewalLED inverter batton fitting1 x18/20 Watt, 220 V decorative box type with driver 4 complete fitting connection with 3 core flexible copper cable 23/0.00076 from ceiling rose to tube fitting connection etc complete all as specified and directed. 29 Supply and fixing in renewal LED Ceiling light square recessed mounted LED flat panel complete 600mm x 600mm, 230 volts 35/36 Watt LED light fixing on Surface/ceiling and connecting with 3 corecopper conductor FR-LSH cable etc complete all as specified and directed. 30 Supply and laying/ fixing of GI tube, light grade, 50mm dia for encasing cables for mechanical protection, laid under plinth/ floors/ path/ culverts or fixed on wall or concealed in wall/ floor or along poles or as street light poles or as mounting bracket, bent to shape with complete accessories such as bends/ sockets/ reducers/ saddles including necessary threading/ drilling works complete all as specified and as directed. 31 S&F CMRI certified LED Flame proof 2 x 20 Watt LED tube light fixture, ISI marked, protection IP-65, including integral reflector made of aluminium alloy LM6 etc and all accessories pre- wired & including connecting up with twin core twisted flexible copper conductor in flame proof flexible conduit with suitable size complete all as specified and directed. 32 S&Fin replacement of LED step lights 7 Watts, IP 65 protection complete all as specified and as directed. 33 S&F in replacement of flexible steel conduit pipe flame proof of size 20mm for fixingfor LED flame prrof light / flame proof exhust fan complete all as specified and as directed. 34 S&F in replacement of SSflame proof conduit pipe of size 20mm complete all as specified and as directed. 35 S&F in replacement flame proof Rotary switch with cable termination box in LM6 four pole, 63 Amp (TPN) MCB, 415 volts, rupturing capacity 10 KA and conforming to latest IS/IEC, complete all as specified & directed. 36 S&Fin replacement offlame proof / weather proof LED Bulk head light fitting complete all as specified and as directed. 37 S&F in replacement of LT Cable junction box outdoor shall be made out of polycarbonate reinforced and size should be not less than 205mm x 255mm x 112 mm (upto Cable Size 35/25 sq.mm). The Polycarbonate Junction Box shall be environment friendly, recyclable, halogen & silicon free, anti acid & anti corrosive. The Junction Box shall be rated for Degree of ingress Protection IP 66/69 in accordance with IEC 60695.Weatherproof, UV-resistant, rainwater-proof, temperature-resistant. The gasket material of junction box shall be Polyurethane and the gasket shall be internally embedded. The Junction Box shall be complies with requirements of the standards IEC 60695. The Junction Box with Connectors or Terminal Trip or Bus Bar. The manufacturer of Junction Box / Enclosure shall submit a copy of IEC Certificate . For better safety the Polycarbonate enclosure and shall be fire retardant & self - extinguishing in accordance with IEC 60695.The impact strength of Polycarbonate enclosure / boards i.e. the Degree of protection against mechanical load shall be in accordance with EN 50298 - 98 for IK 08 including one No. 4 pole connector and one No.MCB SP B curved 6-32 Amp and chromium plated clamps and nut bolts, Glands complete all as per manufacturer’s instructions.complete all as specified and as directed. 38 S&F in replacement LT feeder pillar box factor made cubical type dust proof, out door type both side opening of size 1000 x 800 x 400 mm of MS sheet 3 mm thick power coated machine pressed front opening with rubber gasket / bedding , locking arrangement with sliding bolt including aluminium bus bar of400 amps 4 strips mounted on insulators each strip should be munted minimum two insulator and nut bolt panel shall be mounted on angle iron frame and legs made from angle iron of suitable size duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, grouted in PCC (1:2:4) type B1 using 20 mm graded stone aggregate complete incoming / outgoing cable provision omplete all as specified and directed. 39 M&L for Cement Concrete (1:2:4) type B0 using 20mm graded stone aggregate forfoundation and coping of pole complete all as specified and directed. 40 S&Fin replacement offlame proof / weather proof Exhaust fan 12 single phasewith louverscomplete all as specified and as directed. 41 S&Fin replacement offlame proof / weather proof LED Floodlight fitting 100Wattcomplete all as specified and as directed. 42 S&Fin replacement offlame proof / weather proof LED light fitting 60Watt, CMRI certified recommended for gas / Vapor group of IIA & IIIB, Zone 1 & 2and IP 65 protection with die cast aluminum housing with heat resistant toughened glass, with LED tube light fixtuedriver, holder, connector etccomplete with all accessories prewired and including connecting up with three core flexible copper conductor FRLSH wirewith suitable size complete all as specified and as directed. 43 M&L forearthing complete with copper earth plate 600 mmx600 mm x3.15 mm thick buried directly in ground earth plate not less than 2.25 m deep below normal ground level with top edge of the plate not less than 1.5 m below normal ground level connected to and including copper strip 20x3mmby means of bolts, nuts, check nuts and washers of copper/brass including providing of alternate layer from bottom edge to 30cm above top edge of earth plate by chemical fill compound, ground enhancing material, earth powderand after that 1 m back of layer of charcoal dust and common salt including PCC pit in PCC (1:2:4) type B-1using 20 mm graded crushed stone aggregate, RCC framewith 40mm thick RCC cover reinforced with 8mm dia deformed barshandle including excavation and earth work in any type of soil and medium grade GI watering pipe 20mm bore with funnel and wire mesh and light grade GI protection pipe 40mm bore main board complete all as shown in electrical plate No 3 connected to main control board all as specified and testingon completion including dismantling of old earth plate complete all as specified and directed. Note: (i) Excavation, earthwork, charcoal, PCC pit is covered under this item.(ii) Contractor shall be produced the result of earth below 1 Ohm othrewise earthing will not be acceptable. 44 M&L for Earthing complete with galvanized steel earth plate electrodes 600 mmx600 mm x6 mm thick buried directly in ground earth plate not less than 2.25 m deep below normal ground level with top edge of the plate not less than 1.5 m below normal ground level connected to and including galvanized GI strip 25X4mmby means of bolts, nuts, check nuts and washers of galvanized iron and steel including PCC pit in PCC (1:2:4) type B-1 using 20 mm graded crushed stone aggregate, RCC framewith 40mm thick RCC cover reinforced with 8mm dia deformed barshandle. including excavation and earth work in any type of soil medium grade GI watering pipe 20mm bore with funnel and wire mesh and light grade GI protection pipe 40mm bore main board complete all as shown in electrical plate No 3connected to main control board all as specified and testingon completion including dismantling of old earth plate complete all as specified and directed. Note: (i) Rate of excavation, earthwork, charcoal, PCC pit is covered under this item.(ii) The unit rate includes for protection pipe and GI strip 25 x 4mm from top of earth plate up to 7.5 meter above ground level.

Key Value

Document Fees
INR 500 /-
EMD
INR 44000.0 /-
Tender Value
INR 22 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail