| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 24-09-2025 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 01-10-2025 |
| Sl. No. | Item Description |
| 1 | Provision of synthetic (acrylic top layer) Basket Ball court (28MX15M with seating Gallery) with standard measurement prescribed by (FIBA) international basketball federation as per following specifications :-SUB BASE(a)Excavation, levelling and compacting upto 300 mm of the existing surface slope maintain to avoid surface water stagnation.Through cleaning of surface & weed cleaning solution, filling 150 mm thick best quality moorum filling and consolidation with watering and rolling by 8 to 10 tonne roller.WMMProviding 100 mm thick (compacted) with 60 to 40 mm of stone metal watering curing, rolling compacting and cleaning , rolling by 8 to 10 tonne power roller.Cleaning of top surface of WMM and applying 60/70 grade bitumen @10 Kg/10 Sqm over WMM surface,BM Carpet 60 mm thick (compacted): Providing Stone Metal size 12 mm to 20 mm aggregate with bitumen 3.5 % to 4% mixing with metal including compaction and rolling with 8-10-ton roller.SEAL COATProviding 6 mm stone metal & mixing it with 4.5 to 5% bitumen with 60/70 grade, 15 mm thick and layer to be levelled, compacted, cold rolling to be done alongwith dust.9 Layer cushion Synthetic System (ITF certified/ Approved)1- One Coat Primer2- One Coat Resurfacer3 & 4 & 5- Three Coat cushion6 & 7- Two Coats Texture Base Coat.8- One Coats Non-Texture Top Coat9 - One Coats Non-Texture Top PU Coat including installationand line markingBasket ball poles (01 pair)- S&F basket ball poles with 8 inch round,international standard board size 180 CM X105 CM X 25 MM, Transparent Acrylic board with padding standard pole extension 2.20 mtr made of 8 inch round pipe also including rings net dunkings complete all as specified and as directed. |
| 2 | Provision of synthetic (acrylic top layer) Volley Ball court (18MX9M with Seating Gallery) with standard measurement prescribed by (FIVB) international Volleyball federation as per following specifications :-SUB BASE:(a)Excavation, levelling and compacting upto 300 mm of the existing surface slope maintain to avoid surface water stagnation.Through cleaning of surface & weed cleaning solution, filling 150 mm thick best quality moorum filling and consolidation with watering and rolling by 8 to 10 tonne roller.WMMProviding 100 mm thick (compacted) with 60 to 40 mm of stone metal watering curing, rolling compacting and cleaning , rolling by 8 to 10 tonne power roller.Cleaning of top surface of WMM and applying 60/70 grade bitumen @10 Kg/10 Sqm over WMM surface, ,BM Carpet 60 mm thick (compacted): Providing Stone Metal size 12 mm to 20 mm aggregate with bitumen 3.5 % to 4% mixing with metal including compaction and rolling with 8-10-ton roller.SEAL COATProviding 6 mm stone metal & mixing it with 4.5 to 5% bitumen with 60/70 grade, 15 mm thick and layer to be levelled, compacted, cold rolling to be done alongwith dust spreading.9 Layer cushion Synthetic System (ITF certified/ Approved)1- One Coat Primer2- One Coat Resurfacer3, 4 & 5 - Three Coat cushion6 & 7- Two Coats Texture Base Coat.8- One Coat Non-Texture Top Coat9 - One Coat Non-Texture Top PU Coat including installationand line markingVolleyball poles (01 pair) - S&F Volleyball poles adjustable height 2.43m to 2.24 m 3 inchesMS round pipe with standard quality ofnet complete all as specified and as directed. |
| 3 | M&L squared rubble wallingregular coursed well bonded, bedded and solidly hearted, built in cement mortar (1:6) complete all as specified and as directed. |
| 4 | M&L for rendering two coat of cement plaster on stone masonry surfaces or surfaces other than fair faces of brick work ,first coat 15 mm thick in cement mortar (1:6) and second coat cement plaster 10 mm thick in cement mortar (1:4) with WPC @ 3% by weight of cement, finished the surfaces fair and even (WPC will be paid seperately under respective item) complete all as specified and as directed. |
| 5 | M & L for prepration of newly plastered wall sufaces & applyingbirla / J. K. wall care whiteputty 2 mm thick for levelling the surfaces & applyingtwo coats exterior emulsion weather proofpaint over one coat of exterior wall primer incl. of walls complete all as specified and as directed. |
| 6 | Excavation over areas n.exc 1.5m deep and getting out in soft/loose soil complete all as specified and directed. |
| 7 | M&L moorum/red bajrifilling in trenches or paving laid in layers not exceeding 25 cm thick spread, levelled and rammed including watering etc complete all as specified and directed. |
| 8 | M & LPlain cement concrete1:4:8 type D-2 using 40mm graded stone aggregate as in sub- floors,sub-bases,floors foundation, etc complete all as specified. |
| 9 | Removing excavated materials (soil) to a distance exc. 250 m but n.exc 500 mand deposting where directed complete all as specified and as directed. |
| 10 | M&L 25 mm thick cement concrete 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in levelling course of sub base finished even and rough to receive the topping layer, complete all as specified and as directed. |
| 11 | M&L for mirror polished Machine cut kota stone slab flooring 20-25 mm thick size not less then 550X550 mm over 20 mm thick screed in CM(1:6) laid & jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing & polishing complete all as specified and as directed. |
| 12 | M&L Kota stone slab 20-25 mm thick in skirting, over 15mm thick plater in CM (1:4) & jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing & polishing complete all as specified and as directed. |
| 13 | M&L PCC 1:2:4 type B1 (using 20 mm graded stone aggregates) as in surface channes of drain complete all as specified and as directed. |
| 14 | FENCING WORK: |
| 15 | Excavating in post holes in any type of soil each n.exc 0.5 cum , getting out and removing surplus soil to a distance n.exc 50 m and making good surface complete all as specified and as directed. |
| 16 | M & L PCC 1:3:6 type C-2 using 40mm graded stone aggregate as in foundation, filling, mass concrete, sub-floors, floors etc complete all as specified and as directed. |
| 17 | S&F mild steel Angle ironas in posts and struts in fencing includingcutting tops to shape as directed, drilling holes, notching for wire , etc. flat iron fillets (for securing wire mesh etc.) including all necessary drilling bolting or riveting, etc, and similar work and similar conforming to Fe-290 Gde E-165 complete all as specified and directed. |
| 18 | S&F of structural steel work as in tubular pipes including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 complete all as specified and directed. |
| 19 | S&F Mild steel Round bars 10mm dia and over, cut to length, bent to shape required, includinig cranking, bending spirally for hooping of columns, hooking ends and binding with and including mild steel wire annealed not less than 0.9 mm dia or securing with clips quality confirming to Fe-410 W complete all as specified and directed. |
| 20 | S&F mild steel screw bolts (machine made) with hexagonal or sguare heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or screw nut n.exc 5 cm long dia of shank 12 mm complete all as specified and directed. |
| 21 | S&F chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wirecomplete all as specified and directed. |
| 22 | M&L painting steel surfaces exc 10 cm in width or girth with two coats of synthetic enamel paint over a coat primer including preparation of surfaces complete all as specified and as directed. |
| 23 | M & L Preparation of newly steel and iron surfaces of any description n.exc 10cm in width or girth when connected with other painting, applying two coats of synthetic enamel paint over a coat of red oxide paint complete all as specified and as directed. |
| 24 | Surface exacavation not exceeding 30cm deep and average 15cm deep and getting out in soft/loose soil etc complete all as specified and as directed. |
| 25 | M&L PCC 1:2:4 type B-1 using 20 mm aggregate as in coping, benching to hold to lower portion of chain link fencing etc including nesessary formwork complete all as specified and directed. |
| 26 | TOILET BLOCK (SIZE 2MX3M): |
| 27 | Surface excavation not exceeding 30 cm deep and averaging 15 cm deep soft /loose and getting out complete all as specified and directed. |
| 28 | Excavation over areas n.exc 1.5m deep and getting out in soft/loose soilsoil complete all as specified and directed. |
| 29 | Excavation in trenches n exc 1.5 m wide and n exc 1.5 m deep in Hard/dense soilfor foundation etc or for shafts, wells, cesspits, manholes, pier holes etc. n exc 10 sqm on plan and getting out complete all as specified and directed. |
| 30 | M&L moorum/red bajrifilling in trenches or paving laid in layers not exceeding 25 cm thick spread, levelled and rammed including watering etc complete all as specified and directed. |
| 31 | Removing excavated materials (soil) to a distance exc. 250 m but n.exc 500 mand deposting where directed complete all as specified and directed. |
| 32 | Returning filling in, incl spreading, levelling, watering and well ramming in layers not exc 25cm, complete all as specified and directed. |
| 33 | M&L PCC 1:4:8 type D-2 (using 40mm graded stone aggregates) as in mass concrete as in foundation filling and mass concrete complete all as specifed and directed. |
| 34 | RCC M-25 (Design Mix)using 20mm graded aggregates as in foundations, including rafts, footings, foundation beams, plinth beams; bases for columns, etc basement slabs, under reamed plies and mass concrete, complete all as specified and directed |
| 35 | RCC M-25 (Design Mix)using 20mm graded aggregates as in Columns, pillars, piers, posts and struts and the like, complete all as specified and directed. |
| 36 | RCC M-25 (Design Mix)using 20mm graded aggregates as in Beams, cantilevers, bressummers, lintels over 1.5m span and the like, complete all as specified and directed. |
| 37 | RCC M-25 (Design Mix)using 20mm graded aggregates as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like and the like, complete all as specified and directed. |
| 38 | M&L MS \"TMT\" bars 10mm dia and over in reinforcement, cut to length, bent to shape required including cranking, bending sprially for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with chips complete all as specified and directed. |
| 39 | All as per item 38 above but for 5mm dia and over upto 10 mm dia and including 10mm dia in stirrups, spacers and binders complete all as specified and directed. |
| 40 | M&L for form work to sides & soffits of plinth beam and sides of footings getting for fair finished surfaces of concrete complete all as specified and directed. |
| 41 | M&L for form work to sides of columnsas in fair finished surfaces of concrete complete all as specified and directed |
| 42 | M&L for formwork to sides & soffits of floor or roof beams, beam haunchings, girders, bressum-mers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors & beams, etc. for fair finished surfaces of concrete flat complete all as specified and directed |
| 43 | M&L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings & similar work; n exc. 200m thick (horizontal or sloping) Fair finished surfaces of concrete flat complete all as specified and directed |
| 44 | Formwork to edges of concrete flats, breaks in floor, openings in concrete walls, floors and roofs exc 10 cm but n.exc 20 cm width for fair finished surfaces complete all as specified and directed. |
| 45 | M & L Brickwork with subclass `B\" bricks, straight or curved on plan exc 6m mean radius, built in CM (1:6) complete all as specified and directed. |
| 46 | M&L Brick work with with sub class \"B\" bricks, straight orcurved on plan to any radius in half brick thick wallbuilt in cement mortar (1:4) complete all as specified and directed. |
| 47 | M&L for 18mm to 20 mm thick Granite slabof any shade( table rubbed and polished ) machine cut for floor /shelvesin steps, jambs, pillars, window cills& cooking plateforms over 15 mm thick cement mortor 1:4including pointing in whitecement 1:2 using marble dust with admixture of pigment to match shade of the slabslaid bedded and pointed in any mortor complete all as specified and directed |
| 48 | M&L for rounding to the edge of stone slabs oneedgesuch as in steps, cooking plateform and other similar situations complete all as specified and directed. |
| 49 | M & L for 10 mm thick plaster in CM (1:4) mixed with and including water proofing compound @ 3% by weight of cement applied over roof slab, complete all as specified and directed.(Note : WPC will be paid separately) |
| 50 | M&L for 25 mm thick PCC (1:2:4) type B-1 using 20 mm graged stone aggregate as in floors and finished the surfacecomplete all as specified and directed. |
| 51 | M&L nonskid coloured ceramic tiles 7 to 8 mm thick area of each tile exc 0.11 Sqm but not exc 0.18 sqm in floors set and jointed in neat cement slurry and pointed in white or coloured cement to match coiour/shade including 15mm thick screed bed layer in CM 1:6 complete all as specified and directed. |
| 52 | M&Lglazed ceramic coloured tiles on vetical surfaces size 600x300x7mm to 8 mm thick over & including 10mm thick renderingin CM 1:4 set and jointed in neat cement slurry and pointed in white/coloured cement to match the shade /colour of tiles complete all as specified and directed. |
| 53 | S & F Factory made Solid PVC prelamDoor Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet single side prelam PVC sheet wood grain printed used instead of Plain colour PVC sheet & edges will be painted to match with prelam sheetreinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing complete all as specified and directed. |
| 54 | S&F factory made solid PVC moulded door shutter, 28 to 30mm thick (stiles), with 2, 4, or 6mm raised panel design with 4mm thick moulded PVC sheet prelamon the front face & 4mm prelam PVC sheet on back face, supplying & fixing in frame centre core will be PVC battern complete all as specified and directed. |
| 55 | S&F aluminium anodised barrel tower bolts of extruded section, length of bolt in 150 mm complete all as specified and directed. |
| 56 | S&F Aluminium handles 150mm size, cast type, anodised complete all as specified and directed. |
| 57 | S&F Butt hinges of 100 mm size, Medium weight, stainless steel and fixed, complete all as specified and directed. |
| 58 | S&F powder coated anodised aluminium ventilator shutters, half portion will be fixedwith 4mm thick frosted glass and half portion will be fixed with louvers with 4mm thick frusted glass with rubber gasket and aluminium beading ,aluminium grill with fixing arrangement (wt. of grill not less then 2.50 kg/sqm),aluminium wire mess 0.45 mm dia to be fixed over louvers portion, aluminium sections weighing 0.55 kg/m complete all as specified and directed. |
| 59 | S&F GI tubing 15 mm bore medium grade with all fittings fixed to walls and ceilings or laid in floors complete all as specified and directed |
| 60 | S&FGI tubing 20 mm bore medium grade with all fittings fixed to walls and ceilings or laid in floors complete all as specified and directed |
| 61 | S&F CP Bib taps 15 mm bore, cast copper alloy Fancy typewith crtuch or butterfly handle,screwed down, screwed for iron pipe or for brass ferrule fancy type. (weight not less than 400gms), complete all as specified and directed. |
| 62 | S&F Stop valves/angle valve 15 mm bore fancy type, CP with long shank & cup (conncelaed type), cast copper alloy screwed down high presure, with crutch of butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and directed. |
| 63 | S&F Gun-metal, globe or gate valves 20mm bore, with iron wheel head, screwed both end for iron pipe complete all as specified and directed. |
| 64 | S&F Rotational moulded polyethylene water storage tanks capacity 500 litres(cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I andincl dismantling of old unserviceable Water tank and removing from site complete all as specified and directed. |
| 65 | S&F CP Pillar taps 15 mm bore, cast copper alloy, with capstan heads screwed down high pressure, with or without lettered `Hot\" or `Cold\" with long screwed shanks & fly-nuts, screwed for iron pipe complete all as specified and directed. |
| 66 | S& F looking mirror ofselected quality glass 5 mm thick mounted on 6 mm thick water proof plywood with designer beading frame,fixed to wooden/pvc plugs with chromium plated brass screws and cup washers etc complete all as specified and directed. |
| 67 | S&Fbrass chromium plated tubular towel rail, 20 mm dia, D type, 60 cm long between flanges fixed with and including chromium plated screws and wooden /plastic cleats (min wt 190 grams) complete all as specified & directed. |
| 68 | S&F vitreous china urinal half stall type flat back of size 375mmx395mmx590mm (minimum) whitewith grating and union for discharge pipe, waste pipe, urinal spreader PTMT incl PVC connection 15 mm bore and 450 mm long complete all as specified and directed. |
| 69 | S&Fvitreous China under counter basin (Wash basin) oval shapesize 190 x 550 x 430mm with brass coupling and suitable Outlet PVC waste pipe complete all as specified and directed |
| 70 | S&FVitreous China wash down water closet pan (pedestal pattern), white including white seat cover complete all as specified and directed. |
| 71 | S&FPVC valveless, syphonic action type, flushing cistern (dual 5/10ltr capacity), low level, white, with intel, ball valve, float , handle and flush pipe 32mm bore,and brackets complete all as specified and directed. |
| 72 | S&F PVC connections 15mm bore size 450 in length with both endbrass/pvc high quality nuts complete all as specified. |
| 73 | M&L for 75mm thick PCC type C-2, (1:3:6) using 20mm graded stone aggregate as in plinth protection surface finished even and smooth without using extra cement provided with construction joint 10 x 20mm filled with bitumen and sand mortar 1:3 complete all as specified and directed |
| 74 | M&L for 15 mm thick cement plaster in CM 1:4 on even surface of brick wall mixed with 3%WPC finished even and smooth withoutusing extra cement, complete all as specified and as directed. (Note:- Water proofing compound shall be measured and paid separately under respective items). |
| 75 | M&L 15mm thick rendering in cement mortar 1:6 in other than fair faces of brick workfinished even & smooth without using extra cement complete all as specified and directed. |
| 76 | Supply only integral water proofing compound complete all as specified and directed |
| 77 | M&L for rendering5 mm thick cement plaster in CM 1:3 on concrete surfaces as in ceiling finished even and smooth (without using extra cement) complete all as specified and directed |
| 78 | M & L for prepration of newly plastered wall sufaces & applyingbirla / J. K. wall care whiteputty 2 mm thick for levelling the surfaces & applyingtwo coats exterior emulsion weather proofpaint over one coat of exterior wall primer incl. of walls complete all as specified and directed. |
| 79 | M & L for prepration of newly plastered wall surfaces & applyingbirla / J. K. wall care whiteputty 2 mm thick for levelling the surfacesof walls and applying two coat of distemper oil emulsion over a coat of wallprimer incl. preparation of surfaces ofwalls etc complete all as specified & directed. |
| 80 | M &L for applying three coats of white wash on newly plastered ceilingsurfaces including preparation of these surfacescomplete all as specified & directed. |
| 81 | S&F PVC (SWR) pipes 110mm bore single socketed in any length with adhesive joints fixed to walls complete all as specified and directed. |
| 82 | S&F PVC (SWR) vent cowl 110mm dia complete all as specified and directed. |
| 83 | S&F PVC (SWR) pipes 110mm bore single socketed, in any length with adhesive joints laid in trenches or in floors complete all as specified and directed. |
| 84 | S&F PVC Bends any radius 110mm dia provided with access door complete all as specified and directed. |
| 85 | S&F PVC (SWR), junction single, (Single T) equal or unequal 110mm dia complete all as specified and directed. |
| 86 | M&L PVC (SWR) floor trap 75mm dia plain with grating including jointing with solvent cement complete all as specified and directed. |
| 87 | S&F in repairs 75 mm dia PVC (SWR) pipes single soketed in any length with rubber ring jointedlaid in trenches or in floors complete all as specified and directed. |
| 88 | S&F PVC (SWR) bends 75 mm dia complete all as specified and directed. |
| 89 | S&F PVC (SWR) bends 75 mm dia with accessable door complete all as specified and directed. |
| 90 | M&L reinforced concrete pipes 150mm dia ,class NP2 ,laid and jointed complete with socket and spigot joint and sealed complete all as specified and directed. |
| 91 | M&L for concrete bed ofPCC 1:3:6 type C2 using 40mm graded stone aggregate for NP2150mm bore, bedding and hanching completely after pipes are laid, jointed and tested complete all as specified and directed. |
| 92 | M&L Precast reinforced cement concrete type B1 (1:2:4) using 20 mm graded aggregate set in CM(1:4) in landings, cover slabs (for manholes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces complete all as specified and directed. |
| 93 | M&L PCC in surface channels and drains type B1 (1:2:4) using 20 mm graded stone aggregate complete all as specified and directed. |
| 94 | Material and labour for machine pressed precast concrete interlocking paver block glossy finished, chemically treated any shape and size confirming to IS-15658-2006 size of 60 mm thickness, M-35 Grade with grey cement and pigment overlaid on stone dust cusion of 25 mm thickcomplete all as specied and directed. |
| 95 | M&L for provn of water proofing roof treatment to non-accessible RCC roof with approved modified membrane weight not less than 3 kg/sqm comprising with following items complete all as specified and as directed. (i) The surface of roof, parapet and gutters drain mouths etc over which water proofing treatment is to be applied shall be cleaned of all foreign matter such as fungus, mass dust etc by wire brushing and dusting.(ii) Oil based Bitumen primer conforming to IS-3384-1986 @ 0.3 kg per sqm to be applied on prepared surface till the surface is properly impregnated.(iii) Applying one coat of hot blown bitumen of 85/25 grade @ 1.20 kg/Sqm.(iv) Laying of water proofing treatment of weight not less than 3 Kg / sqm APP modified polymeric water proofing membrane composed of 100 micron (+10%) high density polyethylene sheet (HMHDPE) as centre core, which is sandwiched between high quality polymeric bitumen mix having softening, high heat resistance and cold flexible protected on either side with a thin thermo fusible HMHDPE film with side and laps 75 mm and 100 mm as per manufacture instruction etc.(v) Applying one coat of hot blown bitumen of 85/25 grade @ 1.20 kg/Sqm over the membrane(vi) Applying aluminium paint in two coat @ 100 gm/sqm in each coat on finished membrane surfaces, complete all as specified and directed at site. |
| 96 | Supply and laying ,jointing and testing XLPE insulated armoured heavy duty electric cable with aluminium conductor ,1100 volts, grade ,cross section area 25 Sqmm 4 core complete laid in trenches, ducts or fix to pipe, on walls, poles complete all as specified and directed. Note :- Excavation and earth shall be measured separately |
| 97 | Excavation in trenches n. exc 1.5 mtr wide and n. exc 1.5 mtr depth for laying of cable as the case may be and getting out hard / dense soil complete all as specified and directed. |
| 98 | M&L for sandcushioning in trenches for the cable etc complete all as specified and directed. |
| 99 | Returning filling, spreading, leveling, watering and well ramming in layers n. exc 25 cm thick complete all as specified and directed. |
| 100 | Removing excavated surplus material n. exc 50 mtr and depositing where directed at a level n. exc 1.5 mtr from starting point complete all as specified and directed. |
| 101 | Supplying and laying un-reinforced precast concrete cable cover, Class LV, Type I, flat, size 250 mm x 150mm x 40mm complete all as specified and directed. |
| 102 | S&F in replacement of GI Pipe light grade 50 mm dia ISI marked on pole on wall or laid in trenches incl all fittings (nut, bolt, clamps & washers) complete all as specified and directed. |
| 103 | Supply and fixingtubes light grade GI tubing 40 mm dia withall fitting laid in trenches complete all as specified and directed. |
| 104 | Supply and fixstreet light Engineering plastic one piece moulding junction box with locking arrangmentmade out ofHDPE and FI clamp 25 x 3mm complete ofdimensions in CM+/-10%(34x28x13) including MCB SP 6 Amp 240 Volts complete with 03 Nos aluminium busbar of rating 63 amps for three phaseand neutral on porcelain based insulators and fixing clamps to pole for street lights, complete all as specified & directed at site. |
| 105 | Supply, erecting and fixing in true vertical position, steel tubular swaged pole (410 SP – 31) conforming to IS 2713 (part 1 to 3), 9 mtr long, complete with cast iron base plate, pole cap / finial taper plug, bolts, nuts and washers,including two coats of black bituminous paint externally upto planting depth and remaining exterior portion of pole shall be provided with one coat of red oxide primer and two coats of aluminium paint complete all as specified and directed. (Numbering of the poles shall be done with synthetic enameled painted letter of shape & size as directed).Note:(a) Cost of numbering of pole shall be deemed to included in unit rate.(b) Excavation,Earth work and PCC foundation will be measured and paid for separately.(c) The pole shall be marked with designation, manufacturer\"s identification and year of manufacture |
| 106 | Supply and fixing testing and commissioning energy savingpressure die cast aluminium housing IP 66 protection LED Flood light fitting luminaire of 210 watt LED complete with driver and other accessories complete all as specified and directed. |
| 107 | M&L for plain cement concrete 1:4:8 type D-2 (using 40mm graded stone aggregate) in foundation of PCC poles/struts as specified including necessary form work, complete all as specified & directed. |
| 108 | M&L for plain cement concrete 1:3:6 type C-2 (using 40mm graded stone aggregate) in foundation of stay assembly etc including necessary form work, complete all as specified & directed. |
| 109 | M&L for plain cement concrete 1:2:4 type B-1 (using 20mm graded stone aggregate) for coping around poles, including necessary form work finishing even and smooth without using extra cement, complete all as specified & directed. |
| 110 | S & F GIbracket made out of GI pipe light grade of size 32 mm 1.2 m long cut to length bend to the required shape and 02 Nos mounting flat iron clamps size 40mm x 6mm, 04 Nos hexagonal bolts 10mm dia 100mm long with nuts and washers complete all as specified and directed. |
| 111 | Supply and connecting 1100 volts grade heavy duty cable with PVC insulated solid aluminium conductor served with an inner sheathing of PVC tape and overall PVC sheathed of size 4 sqmm 2 core for pole box to street light fitting complete all as specified and directed. |
| 112 | M&L for provn of Earthing complete with galvanised steel earth plateelectrode, 600x600x6mm buried directly in ground (Earth pit not less than 2.25M deep below the GL) with top edge not less than 1.5 metres below ground level connected with galvanized earth lead wire 4 mm dia by means of bolts, nuts, check nuts & washers of GI or steelall as shown in electric plate no 3 connected to earthing test point all as specified or indicated including testing on completion complete all as specified and directed. Note :- (i) The rate quoted shall also deemed to include the cost of GI wire and protection pipe upto 7.5 Mtr beyond the earth plates electrode and also the costof the Test point. (ii) Joining of GI earth wire with pipe of the test point shall be done by using suitable cable lugs. |
| 113 | Supply,fabricate , fixing structural mild steel RS joist , channelangle iron, flat iron and brackets etc for fabrication of cross arms, bracing supports clamps including D clamps, eye hook and back plate etc fabricated from structural steel section includingnuts , bolts, washers, welding (cold and hot ) drilling holes for bolts, bend to any shape or size as indicated and directed , inclusive of one primer coat and two coats of aluminium paint after preparation of surfaces complete all as specified and directed. |