| 1 | Schedule \"A\" Part-I (BUILDINGS AND STRUCTURES)This Schedule (contains under mentioned Sl item No. 1.01) is not prepriced by MES and the prepriced rate indicated in Col - 5 as ₹0.00 indicates this fact only. The tenderer is required to quote their rates in Col 6. |
| 2 | Lumpsum price worked out by the contractor for Construction of sport complex with Badminton courts and Basketball court in single storey with structural steel roof truss and galvalume sheet rooting and RCC roof at various heights with RCC framed structure including all fittings and fixtures complete all as specified and as shown on drawings. |
| 3 | Lumpsum price worked out by the contractor for Construction of septic tank of 100 users including all fittings and fixtures complete all as specified and as shown on drawings. |
| 4 | Lumpsum price worked out by the contractor for Construction of soakage well of 2.40 metre dia and 4.50 metre deep including all fittings and fixtures complete all as specified and shown on drawings. |
| 5 | Lump sum price worked out by the Contractor for “SITE CLEARANCE AND AREA DEVELOPMENT\" as listed in Schedule ‘A’ Part - IIrepresenting__________ % __________________ percent Above / Below the lump sum price of `13,93,498.09 inserted by the MES in Schedule ‘A’ Part - II |
| 6 | Lump sum price worked out by the Contractor for “AREA DRAINAGE” as listed in Schedule ‘A’ Part - III representing__________% ___________________ percent Above /Below the lump sum price of `21,96,012.22 inserted by the MES in Schedule ‘A’ Part - III |
| 7 | Lump sum price worked out by the Contractor for “SEWAGE DISPOSAL” as listed in Schedule ‘A’ Part - IV representing__________% ___________________ percent Above /Below the lump sum price of ₹1,82,251.79 inserted by the MES in Schedule ‘A’ Part - IV |
| 8 | Lump sum price worked out by the Contractor for “FENCING / COMPOUND WALL / GATE” as listed in Schedule ‘A’ Part - V representing__________% ___________________ percent Above / Below the lump sum price of ₹12,52,311.12 inserted by the MES in Schedule ‘A’ Part - V |
| 9 | Lump sum price worked out by the Contractor for “ROAD / PATH / CULVERT / HARDSTANDING” as listed in Schedule ‘A’ Part - VI representing__________ % ____________ percent Above /Below the lump sum price of ₹25,94,256.00 inserted by the MES in Schedule ‘A’ Part - VI |
| 10 | Lump sum price worked out by the Contractor for “INTERNAL ELECTRIFICATION” as listed in Schedule ‘A’ Part - VII representing_________% ___________________________ percent Above / Below the lump sum price of `2,34,518.16 inserted by the MES in Schedule ‘A’ Part - VII |
| 11 | Lump sum price worked out by the Contractor for “INTERNAL WATER SUPPLY” as listed in Schedule ‘A’ Part - VIII representing_________% ___________________________ percent Above / Below the lump sum price of `40,089.53 inserted by the MES in Schedule ‘A’ Part - VIII |
| 12 | Lump sum price worked out by the Contractor for “EXTERNAL ELECTRIFICATION” as listed in Schedule ‘A’ Part - IX representing_________% ____________________________ percent Above / Below the lump sum price of `3,15,432.39 inserted by the MES in Schedule ‘A’ Part - IX |
| 13 | Lump sum price worked out by the Contractor for “EXTERNAL WATER SUPPLY” as listed in Schedule ‘A’ Part - X representing_____________% ________________________ percent Above / Below the lump sum price of ₹58,234.45 inserted by the MES in Schedule ‘A’ Part - X |
| 14 | Schedule \"A\" Part - XIThis Schedule is not prepriced by MES and the prepriced rate indicated in Col - 5 as ₹0.00 indicates this fact only. The tenderer is required to quote their rates in Column 6. This Schedule constitutes Sl. Item Nos. 12.00 to 25.00. |
| 15 | ROAD / PATH / CULVERT / HARDSTANDINGM&L for road marking 2mm thick centre line, side line, stop line, dashes, arrows, barckets and similar work on road surfaces as per IRC pattern with thermo plastic paint of approved quality and make with 8% glass beads laid at temprature 1600 C with a special applicator machine complete all as per manufacturer\"s instructions and traffic diversion arrangement complete all as specified and directed. |
| 16 | INTERNAL ELECTRIFICATIONS&F, energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium IP-66 flood light, suitable for highlighting architectural facade and general purpose lighting suitable for indoor sports 200 watts power IP-66 protection 230 volts including all necessary fixing arrangements complete all as specified and directed. |
| 17 | S&F, energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium IP-66 flood light, suitable for highlighting architectural facade and general purpose lighting suitable for indoor sports 120 watts power IP-66 Protection 230 volts including all necessary fixing arrangements complete all as specified and directed. |
| 18 | S&F, electronic digital score board suitable for basket ball sports complete all as specified and directed. |
| 19 | S&F, electronic digital score board suitable for badminton sports complete all as specified and directed. |
| 20 | S&F, MCCB DB VTPN 6 ways with metal double door, powder coated IP-43 protection suitable for MCCB as incommer and MCB as outgoing, VTPN DB\"s 415 volt, 3 phase complete with appropriate size copper bus bar and neutral link as required at site and including cutting chases to wall for fixing of DB complete all as specified and directed. |
| 21 | S&F, MCCB 4 Pole, 415 V adjustable thermal magnetic release type, 63 A with breaking capacity 25 KA complete all as specified and directed. |
| 22 | EXTERNAL ELECTRIFICATIONS&F, weather proof street light SMC / FRP junction box of size 270 x 225 x 135mm including MCB SPN 6 Amps \"C\" curve and connecting terminals 4-way including fixing with street light steel tubular pole using necessary MS clamps, nuts, bolts washers of suitable size etc., complete all as specified and directed. |
| 23 | Supply, fabricate, install, connect, test & commission outdoor type dust & vermin proof LT electrical panel board, 1100 volts, 50 Hz AC supply, fully compartmentalised for cable chamber and busbar chambers with adequate space made out of 3.15 mm thick CRCA sheet for load bearing like all over body, front and back cover with hinges and aldrops with DC locks CRCA poweder coated and 2mm thick MS Sheet for non load bearing and portions, complete with one coat of powder coating including suitable angle iron / flat iron frame work / supports bottom 50 x 50 x 6 mm MS channel as base and chamber for metering equipment complete suitable for mounting following switch gear items internally connected with suitable capacity aluminium strip / rods insulated and connection wirings with FRLS copper conductor complete mounted on PCC pillars foundation, arrangements for bus bar trunking system, |
| 24 | cable connectionusing new lugs complete with danger notice all as specified and comprising of the followings:-Note: (i) Existing cables which removed from old panel board will be fixed with new lugs during fixing in new panel board (as if required).(ii) Getting of approval for panel board drawing from Engineer-in-Charge is necessary before fabrication.(iii) All switch gears should be fixed with 6 mm thick fibre sheet. |
| 25 | (a) LED / Neon indicator bulb in RYB colour - 01 Set.(b) 04 Nos copper bus bar 100 Amps with chamber.(c) Digital Multi function meter for showing Amps (upto 100 Amps) and Voltage (upto 500 voltage) with suitable CT & PT.(d) MCCB 4 Pole, 415 V, 100 Amps, 36 KA - 01 No.Outgoing:(e) MCCB 4 Pole, 415 V, 63 Amps, 25 KA - 03 Nos.(f) MCB 4 Pole, 415 V, adjustable type, 32 A with breaking capacity 16 KA - 01 No (Street light).(g) Suitable cable gland for cable. |
| 26 | Supplying & laying of DWC pipe 40 mm ISI marked alongwith all accessories confirming to IS 14930, Part-II complete with fitting and cutting, jointing etc., in trench / open for LT UG cable protection complete all as specified and directed. |
| 27 | Supplying & laying of DWC pipe 25 mm ISI marked alongwith all accessories confirming to IS 14930, Part-II complete with fitting and cutting, jointing etc., in trench / open for LT UG cable protection complete all as specified and directed. |
| 28 | M&L for cutting of bituminous road / floor for laying of pipe / cables not exceeding 40 cm wide and not exceeding 75 cm deep including refilling / with material and watering well ramming / compacting and making good with PCC 1:2:4 type B1, top 20cm thick complete all as specified and directed. |
| 29 | INTERNAL WATER SUPPLYS&F, two way bib cock with wall flange quarter turn (Low-flow) 16mm dia Make: Kerovit Cat Part No.- KB111005 or equivalent in Cera/Jaquar/Kohler brand complete all as specified and directed. |
| 30 | WATER COOLERS&F, 80 litre storage 60 LPH cooling capacity water cooler with inbuilt UV and RO inclusing all fixing necessary arrangments complete all as specified and directed. |