| 1 | Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends, or edges of landings, stepz cills, sunshades, shelves, lintel etc. and cutting chases for concealed water tubing, concealed conduit wiring, etc., and making good, cutting not exceeding 10 cm girth, in brick walls, complete all as specified. |
| 2 | Reinforced cement concrete, nominal mix, type B-1, (1:2:4), using 20 mm graded stone aggregates as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified. |
| 3 | Use & waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200 mm thick (Horizontal or sloping) with fair finished surfaces of concrete, complete all as specif |
| 4 | Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified. |
| 5 | Rendering 5 mm thick on fair faces of concrete surfaces, finished even and smooth on ceiling in cement mortar (1:3), complete all as specified. |
| 6 | Rendering 15 mm thickon fair faces of brick work or concrete surfaces, finished even and fair on walls in cement mortar (1:6),complete all as specified. |
| 7 | Three coats of white wash on new plastered ceiling surfaces, including preparation of surfaces, complete all as specified. |
| 8 | Two coats of white wash on old ceiling surfaces, including preparation of surfaces, complete all as specified. |
| 9 | Prepration of new plasterd wall surfaces of any description complete all as specified and applying the following: -(a) Applying wall care putty, in two coats& smoothening the surfaces as specified. (preparatory to paint as directed)(b) Two coats of oil bound distemper over and including a coat ofalkali resistantprimer. |
| 10 | Complete removal of existing treatment of any description, including prepration of wall surfaces of any description complete all as specified and applying the following: -(a) Applying wall care putty, in two coats& smoothening the surfaces as specified. (preparatory to paint as directed)(b) Two coats of oil bound distemper over and including a coat ofalkali resistantprimer. |
| 11 | First quality, Glazed ceramic coloured tiles 7-8 mm thick,area of each tile exc. 0.13 Sq.m but n. exc. 0.19 Sq.m on vertical surfaces as in skirting, dado etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile laid over and including 10mm thick rendering in cement mortar (1:4) including necessary cutting as per site requirement complete all as specified |
| 12 | First quality, Non skid ceramic coloured tiles 7 to 8mm thick (square/ rectangular) area of each tile exc. 0.06 Sq.m but n. exc. 0.11 Sq.m,laid in floors etc, set and jointed in neat cement slurry and pointed with grout of matching shade of tiles, laid over and including 15 mm thick bedding layer in cement mortar (1:6), complete all as specified. |
| 13 | Granite jet black shade, 18-20 mm thick,as in step, jambs, cooking platform and like, machine cut, machine polished,bedded and jointed with grey cement slurry & pointed with grout of matching shade including necessary cutting over & including 10 mm thick (average thickness) cement mortar (1:4), complete all as specified. |
| 14 | Rounding of / moulding to edges (half round) of stone of any description including rubbing and polishing (Granite finish), complete all as specified. |
| 15 | Plain sheet glass 6.3mm thick ordinary quality and glazing with oil putty or wooden beads in squaresexc. 0.5 Sq.min each pane complete all as specified |
| 16 | Steel tubes ‘medium grade’, galvanized with all fittings and fixed to walls and ceilings or laid in floors, including taking down existing tube complete all as specified of size: - |
| 17 | 15 mm bore |
| 18 | 20 mm bore |
| 19 | Sink mixer for mixing hot & cold water, cast copper alloy, chromium plated fancy type, long body with wall flange,quarter turn type, screwed end for iron pipe or for union and fixed, suitable for 15 mm bore pipe,IN REPLACEMENT, complete. |
| 20 | Stainless steel sink, single bowlmade out of 1.2mm thick sheet for kitchen or laboratory with plug waste pipe washers including cantilever cast iron brackets connecting union etc overall size 535mm x 460mm with bowl size 470 x 395 x 230 mm, IN REPLACEMENT, complete all as specified.MAKE: NIRALI Cat No. EVAN BG or equivalent make mentioned in Appendix \"B |
| 21 | M&L Acrylic laminated Kitchen Cabinets (Custom made) of depth 19\" to 24\" using Plywoods as under:-(i) Laminated BWP plywood for Box Section (18mm thick) Make - KITPLY/CENTURY/ARCHID PLY/GREEN PLY(ii) Acrylic Laminated BWP plywood for Cabinet Shutters (18mm thick)Make - KITPLY/CENTURY/ARCHID PLY/GREEN PLY(iii) Laminated BWP plywood for Bakc Board of cabinet (12mm thick)Make - KITPLY/CENTURY/ARCHID PLY/GREEN PLY(iv) Acrylic laminated Glossy Sheet finish for Shutters (0.9 to 1.2mm thick)Make - SUNMICA/SUN GLOSS/GREEN LAM/ KITLAM/NOVAPANCut and factory fabricated including edging and lipping & fixed with screws for cabinet boxes and shutters purpose all as specified and as directed by Engineer-in-Charge.Adhesives - PIDILITE/FEVICOL/VERMICOLNote: for above two items(i) Glass for cabinets will be measured and paid separately as supply only item.(ii) Area calculated for payment will be measured in Length and breadth from frontal side of cabinet.(iii) Laminating incl lipping shall be Factory fabricated and finished.iv) Rate includes M&L racks, soft closing side/ bottom telescope drawer channels tracks for drawers & soft closing modular hinges. Make - HETTICH/HARDWIN/DYNA/GODREJ(v) Rate include M&L fitting of 2nos modular SS plate racks, 2nos plaint racks, 1no. oil racks & 1no. cutlery rack per kitchen.(vi)Rate includes M&L Aluminium powder coated handle profile section for shutters as approved Note - The work against this item shall be executed in kitchens of OMQ area. The contractor shall record measurements for each kitchen seperately as per site and as directed by Engineer -in-Charge. |
| 22 | Acrylic laminated Kitchen Cabinets (Custom made) of depth 15\" to 18\" using Plywoods as under:-(i) Laminated BWP plywood for Box Section (18mm thick) Make - KITPLY/ CENTURY/ ARCHID PLY/GREEN PLY(ii) Acrylic laminated BWP plywood for Cabinet Shutters (18mm thick)(ii) Laminated BWP plywood for Back Board of cabinet (12mm thick)Make - KITPLY/CENTURY/ARCHID PLY/GREEN PLY(iv) Acrylic laminatd Glossy Sheet Finish for Shutters (0.9 to 1.2mm thick)Make:- SUNMICA/SUN GLOSS/GREEN LAM/KTILAM/ NOVAPANCut and factory fabricated including edging and lipping & fixing with screws for cabinet boxes and shutters purpose all as specified and as directed by Engineer-in-Charge. |
| 23 | Point wiring with multi-stranded copper conductor, single core, FRLSH PVC insulated and unsheathed cable, including FRLSH PVC insulated unsheathed stranded copper conductor single core cable as earth continuity conductor to common earth and connected to earth dolly, with and including modular metal flush boxes made out of 1.6mm thick MS sheet concealed in wall modular metal flush box & including modular cover plate with framehaving necessary cutting for fixing switches/ socketscomprising the following: - |
| 24 | One socket outlet three pin, 6 Amp, independent, with 1.5 Sq. mm (nominal area) cable &1.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium duty concealed conduit not less than 20mm dia all as specified. |
| 25 | One socket outlet three pin, 6/16 Amp, independent, with 2.5 Sq. mm (nominal area) cable & 2.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium duty concealed conduit not less than 20mm dia all as specified. |
| 26 | Switch modular type single pole one way, 6 Amp, complete all as specified. |
| 27 | Switch modular type single pole one way, 16 Amp, complete all as specified. |
| 28 | Socket outlet multipurpose having provision for 2&3 pin, 6 Amp, 2 Module complete all as specified. |
| 29 | Socket outletmultipurpose having provision for two-in-one 3 pin 6 Amp & 3 pin 16 Amp,2 Module complete all as specified. |
| 30 | Taking down shutters of any description exceeding 1.00 sqm but not exceeding 2.00 sqm each and refixing in the same opening after easing adjusting and minor repair complete all as specified. |
| 31 | Taking down cement plaster of any description on brick walls or concrete surfaces etcincluding raking out joints, hacking for key, scrubbing down with water etc complete all as specified. |
| 32 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and removing serviceable tiles to store and rubbish off the premises complete all as specified. |
| 33 | Demolition of reinforced concrete of any description and in any position not otherwise specifically provided for (reinforcement cut as required to facilitate demolition) complete all as specified. |
| 34 | Dismantling boarding any description fixed in any position with nails complete all as specified. |
| 35 | Notes:Amount ofcredit for retrieved materials is mentionedintender documents in pdf form which will be deducted while acceptance of tender offline. |