| 1 | (A)Supply Material |
| 2 | Cartage of Following material from central store Meerut to 33/11 KV S/S. (distance up to 50 KM approx.) including loading & unloading at both ends (Length cable upto 50 meter each or part their off) :- (A) 11KV VCB, I/C, O/C CTR 600/300/5A, 350MVA, 24 Volt |
| 3 | (B) Battery Charger 24 Volt |
| 4 | (C) Battery Set 24 Volt |
| 5 | (D) Lightening Aresstor |
| 6 | (E) 33 KV CT |
| 7 | (F) 33 KV VCB 800A, 1250A |
| 8 | (G) 33 KV Control Panel double T/f |
| 9 | (H) 11 KV P.T |
| 10 | Erection of 11KV VCB, I/C CTR 600/300/5A, 350MVA, 24 with complete work indoor. (as per UPPCL Respo) |
| 11 | Erection of 11KV VCB, O/G CTR 600/300/5A, 350MVA, 24 with complete work outdoor. (as per UPPCL Respo) |
| 12 | Erection of Battery Charger 24 Volt (as per UPPCL Respo) |
| 13 | Erection of Battery Set 24 Volt (as per UPPCL Respo) |
| 14 | Erection of Lightening Aresstor (as per UPPCL Respo) |
| 15 | Erection of 33 KV CT (as per UPPCL Respo) |
| 16 | Erection of 11 KV PT (as per UPPCL Respo) |
| 17 | Erection of 33 KV VCB 800A, 1250A (as per UPPCL Respo) |
| 18 | Erection of 33 KV Control Panel double T/f (as per UPPCL Respo) |
| 19 | Dismantle of Following material :-(A) 11KV VCB, I/C CTR 600/300/5A, 350MVA, 24Volt (as per direction of supervising engineer) |
| 20 | (B) 11KV VCB for O/G, CTR 200/100/5A, 350MVA (as per direction of supervising engineer) |
| 21 | (C) Battery Charger 24 Volt (as per direction of supervising engineer) |
| 22 | (D) Battery Set 24 Volt (as per direction of supervising engineer) |
| 23 | Providing & Laying of different size of (2×2.5) mm2 control cables i.e. from Buchholz realy to Marshalling box Marshalling box to switch gear room, 33 KV CT\"s to CT\"s Junction Box, CT 33 KV, 33 KV P.T, V.C.B. Control Panel Junction Box to 33 KV VCB control panel and control panel to 33 KV VCB outdoor operating mechanism panel from T/F etc. in the cable trench including making proper connection at Buchholz Relay, Marshalling box as per required for installed equipment. (as per direction of supervising engineer) |
| 24 | Providing & Laying of different size of (4×2.5)mm2 control cables i.e. from Buchholz realy to Marshalling box Marshalling box to switch gear room, 33 KV CT\"s to CT\"s Junction Box, CT 33 KV, 33 KV P.T, V.C.B. Control Panel Junction Box to 33 KV VCB control panel and control panel to 33 KV VCB outdoor operating mechanism panel from T/F etc. in the cable trench including making proper connection at Buchholz Relay, Marshalling box as per required for installed equipment. (as per direction of supervising engineer) |
| 25 | Providing & Fixing of 33 KV CT Clamps (as per direction of supervising engineer) |
| 26 | Providing & Fixing of 33 KV CT JUNCTION BOX (as per direction of supervising engineer) |
| 27 | Providing & Fixing ofMOG (as per UPPCL Respo) |
| 28 | Providing & Fixing of WTI/OTI(as per UPPCL Respo) |
| 29 | Replacement of Digital volt meter and Emitter(as per UPPCL Respo) |
| 30 | Cartage of Dismantled and removal material from J.E store to Central Store Meerut including loading & unloading at both ends maximum distance about upto 35 Km. |