| 1 | Earthwork excavation for foundation in all soils and sub soils in hard stiff clay, stiff black cotton, hard red earth, shales, murram, gravel, stoney earth and earth mixed with small size boulders and to full depth as may be directed,except in hard rock,requiring blasting including shoring and shuttering and bailing out of water wherever necessary,refilling the sides of foundation with excavated earth or sand in layer of not more than 15cm thick.well rammed and consolidated and depositing on bank with initial lead and lift of 10m & initial lift of 2m and depositing the surplusr earth within the compound in places shown by the departmental officers with iniital lead and lifts,clearing and levelling the site etc., complete as per SS20B and as directed by departmental Engineers(TNBP No.17,23,24). |
| 2 | PlainCement Concrete 1:4:8 mix (One Part of Cement, Four part ofFine Aggregate and Eight part of Coarse Aggregate) Using 40mm ISS HBG metal for foundation and basement including dewatering if found necessary and laid in layer of not more than 15cm thick and consolidated including all cost conveyance of materials and labour charges etc. complete as per standard specifications and as directed by departmental Engineers(TNBP No.28). |
| 3 | Filling in basement with Well Gravel well rammed watered & consolidated complying with standard specification. |
| 4 | Supplying and erecting centering for sides and soffits including supports and strutting uptp 3.29m height for plane surfaces in all floors with all cross bracings using mild steel sheets of size 90cmx60cm and 10 gauge stiffened, welded with mild steel angles of size 25mmx25x3mm for boarding laid over silver oak (country wood) joist of size 10cmx6.5cm dia spaced about 90cm centre to centre and supported by casuarina props of 10cm to 13cm dia spaced at 75cm centre tocentre etc.complete complying with standard specification and as directed by the departmental engineers. TNBP No.30A)For Beam, Lintel Roof Slab |
| 5 | B)Square column |
| 6 | C) For Grade Beam |
| 7 | Reinforced Cement Concrete 1:1.5:3 mix (One cement and One and a half Fine Aggregate and Three Coarse Aggregate) Using 20mm ISS HBG metal including all cost conveyance of materials and labour charges for curing,finishing but excluding centering,shuttering and cost of reinforcement grills, including vibrating charges etc. complete as per standard specification and as directed by departmental Engineers(TNBP No.30). |
| 8 | Supplying, fabricating and placing in position mild steel or TMT rods for all reinforced cement concrete works as per design given including cost of steel and binding wire with all conveyance and lead charges in all floors etc.complete complyingwith standard specifications and as directed by the deparmental engineers.TNBP No:30 |
| 9 | Random Rubble Masonry using CM 1:5 (One part of cement & five parts of sand) mix using rough stones and bond stones for foundation and basement and including pointing above G.L including cost and conveyance of materialsto work site and including all labour charges for mixing, laying, curing the concrete etc., complete as per standard specifications and as directed by departmental Engineers.TNBP No:35H |
| 10 | Brick Work in CM 1:5 (One part of cement & five parts of sand) mix using Third Class Country Brick Kiln Burnt bricks 8 ¾ \" x 4 ¼ \" x 2 ¾\" including cost and conveyance of materialsto work site and including all labour charges for mixing, laying, curing the concrete etc., complete as per standard specifications and as directed by departmental Engineers – TNBP No:31 |
| 11 | Special Ceiling Plastering with CM 1:3 (One part of cement & three parts of sand)mix for 10mm thick including cost and conveyance of materials to work site and including all labour charges for mixing, laying, curing,finishing etc., complete as per standard specifications and as directed by departmental Engineers – TNBP No:30,56&57 |
| 12 | Plastering with CM 1:5(One part of cement & five parts of sand) mix for 12mm thick including cost and conveyance of all materialsto work site and including all labour charges for mixing, laying, curing,finishing etc., complete as per standard specifications and as directed by departmental Engineers – TNBP No:56&57 |
| 13 | Weathering course concrete using best quality broken brick jelly of size 20mm uniform gauge in pure slaked lime (no sand to be used) over the RCC roof slab in the propotion of brick jelly to lime being 32:121/2 by volume and laid over in a single layer and consolidated to the required design and finished thickness , beating the concrete with wooden beaters of approved pattern, keeping the surface constantly wetted by sprinkling lime jaggery water as per standard specification,etc.complete as directed by the departmental officers.TNBP No:44-I |
| 14 | Finishing with top of roof with one course of machine pressed tiles of size 20cmx20cmx20cm of approved quality laid in cement mortar 1:3 (One cement and three sand) 12mm thick mixed with water proofing compound conforming to ISS by 2% weight of cement used and the joint pointed neatly to full depth of tiles with same water proofing compound mixed with cement motar ,red oxide, etc.complete complying with standard specification as directed by the departmental officers.- 10 m2TNBP No:44-I |
| 15 | Daddoing with first quality colour glazed tiles of 150 mm x 150 mm x 6mm size of approved make and quality and colour set in Cement Mortar 1:2 (One Cement and Two Sand) and pointing with white cement neatly including cost and conveyance of all materials etc.and all lobour charges etc.complete as per Standard specification and as directed by the departmental officers.TNBP No:special |
| 16 | Laying with first quality design ceramic tiles of all colours new ceramic tiles 305 x 305x 6mm tk for flooring and set in Cement Mortar 1:3 (one part of cement & three parts of sand)20mm thick and pointed with white cement including adding with suitable colouring pigments of match with the colour of tiles used and curing etc., complete.including cost and conveyance of all materials etc.and all labour charges etc.complete as per Standard specification and as directed by the departmental officers. TNBP No.special |
| 17 | Supply and Fixing of U-PVC Shutter openable Door using GI Steel Reinforcement, Butt hinge,Aldrop lock and foam Sheet includingcost and conveyance of all labour and all meterial charges etc Complete as per standard specification. |
| 18 | Supplying and fixing M.S Grill to doors, special windows and ventilators etc using 20mmx6mm as directed by the departmental officers inclusive of cost of MS grill including one primer coat of red oxide and fixing in position etc. including cost and conveyance of all materials and all lobour charges etc.complete as per Standard specification and as directed by the departmental officers.(as per the schedule of rate)TNBP No:86 & 86-A |
| 19 | Painting the new walls two coats over one coat of priming with best weather proof Exterior Emulsion paint of approved colour and quality including preparation of surface and finishing neatly etc., complete complying with standard specification and as directed by departmental officersComplete as per standard specification. |
| 20 | Painting with two coats of Approvedcolour of best quality synthetic enamel paint, painting over new iron work including cost and conveyance of all materials and all labour charges etc. complete as per Standard specification and as directed by the departmental officers. (New Iron Surface).TNBP No:66&66-A |
| 21 | Wiring with 2x1.5sqmm (22 / 0.3) PVC insulated SC unsheathed Cu. Conductor of 1100v grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories in flush with wall with 3mm thick hylum sheet cover with TW switch box and 5A F.T switch and making good of the concealed portion with suitable colour for PVC concealed light point. SD 24 ISI make with standard specification. |
| 22 | Wiring with 2x1.5sqmm (22 / 0.3) PVC insulated SC unscheathed Cu.conductor of 1100 V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories, in flush with wall, with 150mm x 100mm x 113mm TW switch box with 3mm thick Hylem sheet cover for 5 A 3 pin non inter locking CS Plug with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion with suitable colour for concealed PVC plug point. SD 38ISI make with standard specification |
| 23 | Supply and run of 2 of 6sqmm (56 / 0.3) insulated SC unsheathed Cu.Cconductor of 1100Vgrade on 7/20 GI bearer wire for service connection mains. SD 66ISI make with standard specification. |
| 24 | Supply and run of 2 x 6sqmm (56/0.3) PVC insulated SC unsheathed Cu. Conductor of 1100V grade in 25mm dia GI Pipe ( Class ‘B’) suitably bent at both ends with necessary angle iron upright and end supports for mains. SD 71 ISI make with standard specification. |
| 25 | Supply and fixing of single box type 4’40 w fluorescent fitting LED complete with copper choke and condenser with TW Round on wall and withtube with PVC unsheathed leads from tennauble to the nitting SD 88 ISI make with standard specification. |
| 26 | Supply and fixing of 4’ x 40 watts single street light fitting LED etc., complete SD 93 ISI make with standard specification. |
| 27 | Supply and fixing of TNEB meter board suitable for 32A single phase service connection with 32A fuse unit (500V) 32A neutral link and earth link (1\" x 1/8\" copper flat) on TW plank of size 375mm x 300mm x 19mm with supporting TW reepers of 1\" thick an either side with painting with suitable bolt and nuts for fixing the TW plank on wall with earth connection and inter connection with 7/20 PVC insulated copper wire from EB meter to fuse unit (SD 125) |
| 28 | Supplying and fixing in position Indian water closet of size 580 X 440mm, white glazed earthen ware of approved quality with \"P\" trap or \"S\" trap confirming to IS:2556 -Part XII with sand cushion and forming flooring alround the closet using 40mm broken brick jelly in lime concrete1:2:5 ( one part of lime, two parts of sand and five parts of brick jelly) 100mm thick and finishing the top to required slope and including giving necessary connection to cast iron soil pipes/ PVC pipes by dismandling brick masonry, reinforced cement concrete roof/floor slab and making good the disturbed portion to original condition without leakage etc., complete complying with standard specifications and as directed by the departmental officers. |
| 29 | Supplying and fixing in position White / Colour Glazed Model Floor Mounted European Water Closet of best quality and approved make with 100mm “P” or “S” trap connecting with CI pipe of 100mm dia / PVC pipe of 110mm dia, double flapped rigid PVC black seat and seat cover with CP brass hinges including cost of white cement, cement for packing, spun yarn, teak wood plugs, brass screws, etc., including supplying and fixing 10 liters capacity PVC / 12.5 liters capacity porcelain low level flushing tank with a pair of CI brackets, etc., complete with all fittings, such as, 15mm brass ball valve with polythene float with brass handle, union coupling connected by means of 40mm white PVC flush hand using Indian adopter joint including all internal fittings, such as, 15mm bras connections, 15mm GM wheel valve, 15mm brass nipple (2 Nos.), 15mm nylon connection, TW plugs, screws and also giving necessary connection to the PVC pipe and painting the CI brackets with 2 coats of approved paint over one coat of red oxide primer, dismantling the masonry and re-doing the dismantled masonry to original condition, etc., complete complying with standard specifications. (The EWC and flushing tank with all accessories should be got approved by the Executive Engineer before use on works) Floor Fitting |
| 30 | Supply and fixing 2000 litre capacity PVC water tank including cost and conveyancecharges to site etc complete. ISI make with standard specification. |